A200RI/A300RI Series
High Isolation, 2W & 3W Single & Dual Output DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
Conditions
● 2W & 3W Output Power Input Voltage Range ● Compact DIP Case ● 3,000 VDC Isolation ● Tight Line/Load Regulation Input Filter Reverse Polarity Input Current ● Single & Dual Outputs Short Circuit Input Power ● 17 Standard Models Output ● 800 kH MTBF Parameter ● Industry Standard Pin-Out Output Voltage Accuracy
Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit
Min. 5 VDC Input 4.75 12 VDC Input 10.8 24 VDC Input 21.6 48 VDC Input 43.2 π (Pi) Filter
Typ. 5.0 12.0 24.0 48.0
Max. 5.25 13.2 26.4 52.8 0.5 2,500
Units VDC
A mW Units % % % % mV P - P mV P - P mV rms % μSec % %/ºC
Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Over Line, Load & Temp.
Min.
Typ. ±2.0 ±1.0 ±0.2 ±0.2 40
Max. ±4.0 ±3.0 ±0.3 ±0.5 50 75 5 50 ±6.0 ±0.02
120 50% Load Step Change ±0.01 Continuous Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 3,000 1,000 40 Conditions Typ. Max.
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Units VDC MΩ pF kHz Units ºC ºC ºC %
50 80
100
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Min. Typ. -25 -25 -40 Free Air Convection RH, Non-condensing Max. +71 +90 +125 95
MicroPower Direct
232 Tosca Drive Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Physical
Case Size Case Material Weight 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.42 Oz (12g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. 800 Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units kHours Units VDC ºC mW
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Typ. Max. 7.5 15.0 30.0 55.0 260 3,000
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number A201RI A202RI A203RI A204RI A205RI A211RI A212RI A313RI A214RI A315RI A221RI A222RI A323RI A224RI A325RI A231RI A232RI Notes: Voltage (VDC) Nominal 5 5 5 5 5 12 12 12 12 12 24 24 24 24 24 48 48 Range 4.75 - 5.25 4.75 - 5.25 4.75 - 5.25 4.75 - 5.25 4.75 - 5.25 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 43.2 - 52.8 43.2 - 52.8 Output Fuse Rating Reflected Efficiency Slow-Blow Current Ripple Voltage Current (%, Typ) (mA) (VDC) (mA, Max) (mA, Min) Full-Load No-Load Current
(mA, Typ)
Input Current (mA)
666 628 633 642 639 277 262 397 268 403 138 131 198 134 202 69 66
100 100 100 100 100 50 50 50 50 50 25 25 25 25 25 15 15
70 70 70 70 70 30 30 30 30 30 15 15 15 15 15 10 10
5.0 12.0 15.0 ±12.0 ±15.0 5.0 12.0 15.0 ±12.0 ±15.0 5.0 12.0 15.0 ±12.0 ±15.0 5.0 12.0
400 165 133 ±83 ±66 400 165 200 ±83 ±100 400 165 200 ±83 ±100 400 165
0.0 0.0 0.0 ±0.0 ±0.0 0.0 0.0 0.0 ±0.0 ±0.0 0.0 0.0 0.0 ±0.0 ±0.0 0.0 0.0
60 63 63 62 62 60 63 63 62 62 60 63 63 62 62 60 63
1,000 1,000 1,000 1,000 1,000 750 750 750 750 750 350 350 350 350 350 135 135
1. When measuring output ripple, it is recommended that an external 0.33 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 1.5 μF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR