A400RU Series
Single & Dual Output, 4W Ultra-Wide Input Range DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 4W Output Power • UL Approved (File E245422) • 4:1 Input Voltage Range • 1,500 VDC Isolation • Meets EN55022 Class “A” • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out
Input
Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 24 VDC Input 4.5 6.0 8.5 48 VDC Input 8.5 12.0 17.0 π (Pi) Filter (Complies with EN55022 Class “A”) 1.0 2,000 Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Over Line, Load & Temp. 120 25% Load Step Change 150 ±2.0 ±0.01 Continuous (Autorecovery) Min. 1,500 1,000 Typ. 500 ±0.02 Min. Typ. ±0.5 ±0.5 ±0.1 ±0.3 50 Max. ±1.0 ±2.0 ±0.3 ±1.0 75 100 15 Units VDC A mW Units % % % % mV P - P mV P - P mV rms % μSec % %/ºC
Output
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Conditions 60 Seconds 500 VDC 100 kHz, 1V Max. Units VDC MΩ pF kHz Units ºC ºC ºC %
380 350
500
RoHS Compliant
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity RFI Conducted EMI Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Six-Side Shielded Metal Case Complies with EN55022 Class “A” Ambient Case Max. +71 +90 +125 95
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Physical
Case Size Case Material Weight 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Metal with Non-Conductive Base 0.49 Oz (14g) Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 1.0 UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. -0.7 -0.7 Typ. Max. Units MHours
Reliability Specifications
Parameter MTBF Safety Standards Safety Approvals
Absolute Maximum Ratings
Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Max. 50.0 100.0 260 2,500 Units VDC ºC mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number A401RU A402RU A403RU A404RU A405RU A406RU A407RU A411RU A412RU A413RU A414RU A415RU A416RU A417RU Voltage (VDC) Nominal 24 24 24 24 24 24 24 48 48 48 48 48 48 48 Range 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 Input Current (mA) Full-Load 161 170 201 201 156 201 201 79 84 98 98 76 98 98 Output Reflected Efficiency Current Ripple Voltage Current (%, Typ) (VDC) (mA, Max) (mA, Min) No-Load Current
(mA, Typ)
Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500
20 20 20 20 20 20 20 10 10 10 10 10 10 10
5 5 5 5 5 5 5 5 5 5 5 5 5 5
3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0
900.0 660.0 333.0 267.0 ±300.0 ±167.0 ±133.0 900.0 660.0 333.0 267.0 ±300.0 ±167.0 ±133.0
90.0 66.0 33.0 27.0 ±30.0 ±17.0 ±13.0 90.0 66.0 33.0 27.0 ±30.0 ±17.0 ±13.0
77 81 83 83 80 83 83 78 82 85 85 82 85 85
Notes: 1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 μF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure startup. In this case, it is recommended that a low ESR (ESR
很抱歉,暂时无法提供与“A404RU”相匹配的价格&库存,您可以联系我们找货