0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
A514RW

A514RW

  • 厂商:

    MPD

  • 封装:

  • 描述:

    A514RW - Wide Input Range, 5W Single & Dual Output DC/DC Converters - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
A514RW 数据手册
A500RW Series Wide Input Range, 5W Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 5W Output Power • UL Approved (File E245422) • 2:1 Input Voltage Range • 1,500 VDC Isolation • Meets EN55022 Class “A” • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out Input Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 5 VDC Input 3.0 3.5 4.4 12 VDC Input 4.5 6.0 8.0 24 VDC Input 8.0 12.0 16.0 48 VDC Input 16.0 24.0 32.0 π (Pi) Filter (Complies with EN55022 Class “A”) 1.0 1,000 3,000 Min. Typ. ±0.5 ±0.5 ±0.1 ±0.3 50 Max. ±1.0 ±2.0 ±0.3 ±1.0 75 100 15 300 ±6.0 ±0.02 Units VDC A mW Units % % % % mV P - P mV P - P mV rms % μSec % %/ºC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 20% to 100% Over Line, Load & Temp. 120 25% Load Step Change Continuous Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 1,000 Typ. Max. Units VDC MΩ pF kHz Units ºC ºC ºC % 150 ±2.0 ±0.01 RoHS Compliant General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency 380 300 500 Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity RFI Conducted EMI Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Six-Side Shielded Metal Case EN55022 Class “A” Ambient Case Max. +71 +90 +125 95 MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Physical Case Size Case Material Weight 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Metal with Non-Conductive Base (UL94-V0) 0.42 Oz (12g) Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 1.0 UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units MHours Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Max. 10.0 25.0 50.0 100.0 260 2,500 Units VDC ºC mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number A501RW A502RW A503RW A504RW A505RW A506RW A507RW A511RW A512RW A513RW A514RW A515RW A516RW A517RW A521RW A522RW A523RW A524RW A525RW A526RW A527RW A551RW A552RW A553RW A554RW A555RW A556RW A557RW Voltage (VDC) Nominal 12 12 12 12 12 12 12 24 24 24 24 24 24 24 48 48 48 48 48 48 48 5 5 5 5 5 5 5 Range 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 4.5 - 7.0 4.5 - 7.0 4.5 - 7.0 4.5 - 7.0 4.5 - 7.0 4.5 - 7.0 4.5 - 7.0 Input Current (mA) Full-Load 429 514 595 595 514 595 595 209 251 291 291 251 291 291 104 126 145 145 126 145 145 1,056 1,265 1,463 1,463 1,265 1,463 1,463 Output Reflected Efficiency Current Ripple Voltage Current (%, Typ) (VDC) (mA, Max) (mA, Min) No-Load Current (mA, Typ) Fuse Rating Slow-Blow (mA) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 700 700 350 350 350 350 350 350 350 3,000 3,000 3,000 3,000 3,000 3,000 3,000 20 20 20 20 20 20 20 5 5 5 5 5 5 5 3 3 3 3 3 3 3 70 70 70 70 70 70 70 25 25 25 25 25 25 25 15 15 15 15 15 15 15 10 10 10 10 10 10 10 100 100 100 100 100 100 100 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 1,200.0 1,000.0 500.0 400.0 ±500.0 ±250.0 ±200.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 60.0 50.0 25.0 20.0 ±25.0 ±12.5 ±10.0 77 81 84 84 81 84 84 79 83 86 86 83 86 86 79 83 86 86 83 86 86 75 79 82 82 79 82 82 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 μF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR
A514RW 价格&库存

很抱歉,暂时无法提供与“A514RW”相匹配的价格&库存,您可以联系我们找货

免费人工找货