AD1024-12F 数据手册
AD1024F Series Very Low Cost, 20W DIN Rail Mount Single Output AC/DC Power Supplies Key Features: Models available to 360W! Call today for details Electrical Specifications • 20W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. • DIN Rail Mountable Input • Universal AC Input Parameter Conditions Min. Typ. Max. Units • UL 508 Compliant Universal 100 240 VAC • EN60950 Compliant Input Voltage Range 127 370 VDC • 5, 12, 24 & 48 VDC Outputs Input Frequency 47 63 Hz • Cond./Rad. EMI Class B 110 VAC 22 A • >170 kH MTBF Inrush Current, Cold Start 220 VAC 44 A • LOW COST! Leakage Current 264 VAC 1.8 mA Output Parameter Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Output Power Protection Transient Recovery Time (Note 3) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Typ. ±0.5 Vin = Min to Max ±1.0 Iout = 20% to 100% ±1.0 110 VAC, Full Load 10 220 VAC, Full Load 20 See Model Selection Guide Power Limit 130 2 50% Load Change 5 ±0.02 Continuous With Autorecovery Min. 3,000 2,000 500 100 Typ. Min. Max. Units % % % mSec 160 ±0.03 % mS % %/ºC General Parameter Isolation Voltage Isolation Resistance (Note 4) Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Fixed Conditions Max. Units VAC M kHz Max. +50 +85 95 Units ºC ºC % 66 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Min. Typ. -20 +25 -20 Free Air Convection RH, Non-condensing Ambient Physical Case Size Case Material Connection 3.54 x 2.54 x 1.77 Inches (90.0 x 64.5 x 44.0 mm) Plastic Screw Terminal Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. Typ. Max. Units 170 kHours UL 1950, EN 60950, IEC 60950 Compliance to EN55011, EN55022 (CISPR22) Class B EN61000-4-2,3,4,5,6,8,11 Level 3 Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Model Selection Guide Model Number AD1020-05F AD1024-12F AD1024-24F AD1024-48F Rated Power (W) 20 24 24 24 Output Overvoltage Fuse Rating Ripple & Efficiency Voltage (VAC) Current (A) Protection Slow-Blow Voltage Current (A) Current (A) Noise (%, Typ) (VDC) (A) (VDC) Max) Range (mV P-P) Universal Range 115 VAC 230 VAC 100 - 240 1.0 0.5 5 4.0 0 ~ 4.0 50 7.0 78 2.0 100 - 240 1.0 0.5 12 2.0 0 ~ 2.0 100 20.0 80 2.0 100 - 240 1.0 0.5 24 1.0 0 ~ 1.0 150 40.0 83 2.0 100 - 240 1.0 0.5 48 0.5 0 ~ 0.5 250 60.0 83 2.0 Input Output Notes: 1. Load regulation is specified for a load change of 20% to 100%. 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth with the unit under test operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 µF / 630V metalized capacitor & a 47 µF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 M 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the AD1024F series. 9. The units should be mounted so they are vertically orientated. Air flow (if it is provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. For the AD1024F series, a 250 VAC 2.0A is recommended. Derating Curve Mechanical Dimensions Connections TB 1 Pin 1 2 3 4 5 Function DC Output (+V) DC Output (-V) Frame Ground (FG) AC/Neutral AC/Live Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
AD1024-12F
物料型号: - AD1020-05F - AD1024-12F - AD1024-24F - AD1024-48F

器件简介: AD1024F系列是低成本、20W DIN导轨安装式单输出AC/DC电源模块,具有多种输出电压选项。

引脚分配: - 1号引脚:DC输出(+V) - 2号引脚:DC输出(-V) - 3号引脚:机架地(FG) - 4号引脚:交流/中性线(AC/Neutral) - 5号引脚:交流/火线(AC/Live)

参数特性: - 输入电压范围:100-240VAC - 输入频率:47-63Hz - 启动电流:110VAC时22A,220VAC时44A - 漏电流:264VAC时1.8mA - 输出电压精度:±0.5% - 线路调整率:Vin = Min至Max时±1.0% - 负载调整率:Iout = 20%至100%时±1.0% - 保持时间:110VAC、满载时20ms,220VAC、满载时10ms - 纹波和噪声(20MHz):输出功率保护见型号选择指南 - 瞬态恢复时间:负载变化50%至100%时±0.02%至5mS - 温度系数:50%负载变化时±0.03%/°C - 输出短路保护:连续自动恢复

功能详解: AD1024F系列电源模块具有20W输出功率,DIN导轨安装,全球通用AC输入,符合UL508和EN60950标准,提供5V、12V、24V和48V直流输出,EMI等级为Class B,MTBF大于170,000小时,并且成本低廉。

应用信息: 适用于需要低成本、高效率和高可靠性的AC/DC电源转换的应用场合。

封装信息: 尺寸为3.54 x 2.54 x 1.77英寸(90.0 x 64.5 x 44.0毫米),材料为塑料,连接方式为螺丝端子。