0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AD23603C

AD23603C

  • 厂商:

    MPD

  • 封装:

  • 描述:

    AD23603C - Very Low Cost, 360W DIN Rail Mount Dual Output AC/DC Power Supplies - MicroPower Direct, ...

  • 数据手册
  • 价格&库存
AD23603C 数据手册
AD2360C Series Very Low Cost, 360W DIN Rail Mount Dual Output AC/DC Power Supplies Key Features: • 360W Output Power • DIN Rail Mountable • Universal AC Input • Dual Outputs • UL 508 Compliant • EN60950 Compliant • Cond./Rad. EMI Class B • >100 kH MTBF • LOW COST! Electrical Specifications Input Parameter Input Voltage Range Input Frequency Inrush Current, Cold Start Leakage Current New Industrial Supplies!! Conditions Universal Min. 100 127 47 Typ. Max. 240 370 63 Units VAC VDC Hz A A mA Units % % % % mSec % mS % %/ºC Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. 110 VAC 220 VAC 264 VAC Conditions Min. 22 44 1.8 Output Parameter Output Voltage Accuracy Output Voltage Adjustment Range Line Regulation Load Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Output Power Protection Transient Recovery Time (Note 3) Transient Response Deviation Temperature Coefficient Output Short Circuit Typ. Max. ±0.5 Primary Output Only ±10.0 Vin = Min to Max ±1.0 Iout = 20% to 100% ±1.0 110 VAC, Full Load 10 220 VAC, Full Load 20 See Model Selection Guide Power Limit 130 160 2 50% Load Change 5 ±0.04 ±0.05 Continuous With Autorecovery Min. 3,000 2,000 500 100 Typ. Max. RoHS Compliant Models available from 20W! Call today for details MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com General Parameter Isolation Voltage Isolation Resistance (Note 4) Switching Frequency Conditions Input - Output Input - FG (Frame Ground) Output - FG (Frame Ground) 500 VDC Fixed Conditions Units VAC MΩ kHz 130 Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Vibration Min. Typ. Max. Units -20 +25 +50 ºC -20 +85 ºC Free Air Convection RH, Non-condensing 95 % 10 Hz ~ 2 kHz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Ambient 4.76 x 4.33 x 3.94 Inches (121.0 x 110.0 x 100.0 mm) Aluminum (Base) and Steel (Cover) Screw Terminal Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. Typ. Max. Units 100 kHours UL 1950, EN 60950, IEC 60950 Compliance to EN55011, EN55022 (CISPR22) Class B EN6100-4-2,3,4,5,6,8,11 Level 3 Physical Case Size Case Material Connection Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Model Selection Guide Model Number AD23601C AD23602C AD23603C Rated Power (W) 360 360 360 Input Voltage (VAC) 100 - 240 100 - 240 100 - 240 Current (A) 1.0 1.0 1.0 0.5 0.5 0.5 Universal Range 115 VAC 230 VAC Voltage (VDC) +12 (V1) +5 (V2) +24 (V1) +5 (V2) 48 (V1) +5 (V2) Output Current (A) Current (A) Max) Range 28.0 3.0 14.0 3.0 7.0 3.0 0 ~ 28.0 0 ~ 3.0 0 ~ 14.0 0 ~ 3.0 0 ~ 7.0 0 ~ 3.0 Overvoltage Protection (VDC) 14 ~ 16 N/A 27 ~ 30 N/A 52 ~ 56 N/A Ripple & Noise (mV p-p) Efficiency (%, Typ) 78 80 80 100 50 150 50 250 50 Notes: 1. Load regulation is specified for a load change of 20% to 100%. For models AD23601C, load regulation for V1 (12V) is ±2% 2. Ripple & noise is measured using equipment with 20 Mhz of bandwidth with the unit under test operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 μF / 630V metalized capacitor & a 47 μF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 MΩ 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fitting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recommended for the AD2360C series. 9. The units should be mounted so they are vertically orientated. Air flow (if provided) would optimally flow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. For the AD2360C series a 250VAC 5.0A is recommended. Units with the optional “FT” outputs may be easily connected for “Fault Tolerant operation. Contact the factory for details Derating Curve Mechanical Dimensions Connections TB 1 Pin 1 2 3 4 5 6 7 Function FT (Optional) FT (Optional) +V2 (5V) Output Output Common Output Common +V1 Output +V1 Output Connections TB 2 Pin 1 2 3 Function AC Input - Live AC Input - Neutral Frame Ground (FG Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
AD23603C 价格&库存

很抱歉,暂时无法提供与“AD23603C”相匹配的价格&库存,您可以联系我们找货

免费人工找货