Parameter
Series
High Isolation, 2W Ultra-Miniature, SIP DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Conditions 5 VDC Input 12 VDC Input 24 VDC Input 48 VDC Input
Min. 4.5 10.8 21.6 44.0
Typ. 5.0 12.0 24.0 48.0
Max. 5.5 13.2 26.4 52.0 0.3
Units
Input Voltage Range
VDC
Reverse Polarity Input Current Input Filter Internal Capacitor Conditions For Vin Change of 1% Min. Typ. ±1.2
A
Output
Parameter Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Output Power Protection Temperature Coefficient Output Short Circuit 120 ±0.01 Momentary (0.5 Sec.) Conditions 60 Seconds 1,000 VDC 100 kHz, 1V Min. 3,000 1,000 60 125 Conditions Ambient Case -55 Free Air Convection RH, Non-condensing 95 % Min. -40 Typ. +25 Max. +85 +90 +125 Typ. Max. Units VDC MΩ pF kHz Units ºC ºC ºC ±0.02 Max. ±3.0 Units % % 100 mV P - P % %/ºC
See Model Selection Guide
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Physical
Case Size Case Material Weight 0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.06 Oz (1.8g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Conditions 5 VDC Input Input Voltage Surge (1 Sec) 12 VDC Input 24 VDC Input 48 VDC Input Lead Temperature Internal Power Dissipation 1.5 mm From Case For 10 Sec All Models Min. 2.0 Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units MHours Units
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter Typ. Max. 9.0 18.0 30.0 55.0 260 650 ºC mW
VDC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number E201I E202I E203I E204I E205I E211I E212I E213I E214I E215I E222I E223I E224I E225I E232I E233I E234I E235I Input Output Load Voltage (VDC) Current (mA) Voltage Current Current Regulation Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max) 5 4.5 - 5.5 372 38 3.3 400.0 40.0 12 5 5 5 5 12 12 12 12 12 24 24 24 24 48 48 48 48 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 44.0 - 52.0 44.0 - 52.0 44.0 - 52.0 44.0 - 52.0 533 500 500 500 150 200 211 199 208 107 102 104 102 53 52 53 52 38 38 38 38 30 30 30 25 25 12 12 12 12 6 6 6 6 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 400.0 222.0 167.0 133.0 400.0 400.0 222.0 167.0 133.0 400.0 222.0 167.0 133.0 400.0 222.0 167.0 133.0 40.0 22.0 16.0 13.0 40.0 40.0 22.0 16.0 13.0 40.0 22.0 16.0 13.0 40.0 22.0 16.0 13.0 12 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Efficiency (%, Typ) 71 75 79 80 80 73 77 79 84 80 78 82 80 82 78 80 78 80 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 200 200 200 200 100 100 100 100
Notes: 1. Output load regulation is specified for a load change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The 5V, 12V and 24V input units do not require external components to operate, but the use of a low ESR capacitor (approximately 10 µF, ESR