G200E Series
Low Cost, 2W Compact MiniDIP DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power • Miniature SIP Case • UL Approved (File E245422) • Single & Dual Outputs • 1,000 VDC Isolation • >3.5 MHour MTBF • 24 Standard Models • LOWEST COST!!
Input
Parameter Input Voltage Range Input Filter Reverse Polarity Input Current Conditions 5 VDC Input 12 VDC Input 24 VDC Input Min. 4.5 10.8 21.6 Typ. 5.0 12.0 24.0 Max. 5.5 13.2 26.4 0.3 Conditions Dual Output , Balanced Loads For Vin Change of 1% Min. Typ. ±2.5 ±1.0 ±1.2 100 120 ±0.02 Momentary (1.0 Sec.) Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,000 1,000 60 75 Conditions Ambient Min. -40 -55 Free Air Convection RH, Non-condensing 95 % Typ. +25 Max. +85 +125 Typ. Max. Units VDC MΩ pF kHz Units ºC ºC ±0.03 150 Max. A Units % % % mV P - P % %/ºC VDC Units
Internal Capacitor
Output
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit
See Model Selection Guide
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity
Physical
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Case Size (5V 12V & 24V Input Models) Case Material Weight
0.8 x 0.40 x 0.32 Inches (20.4 x 10.2 x 8.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.07 Oz (2.1g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. 3.5 Typ. Max. Units MHours
Reliability Specifications
Parameter MTBF Safety Standards Safety Approvals
UL 1950, EN 60950, IEC 60950 UL, cUL; File No. E245422 Conditions 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 -0.7 Typ. Max. 9.0 18.0 30.0 300 450 ºC mW VDC Units
Absolute Maximum Ratings
Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number G201E G202E G203E G204E G205E G206E G207E G208E G211E G212E G213E G214E G215E G216E G217E G218E G221E G222E G223E G224E G225E G226E G227E G228E Input Output Load Voltage (VDC) Current (mA) Regulation Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) 5 4.5 - 5.5 494 30 5.0 400.0 40.0 15 5 4.5 - 5.5 488 30 9.0 222.0 23.0 15 5 4.5 - 5.5 476 30 12.0 167.0 17.0 15 5 4.5 - 5.5 476 30 15.0 133.0 14.0 15 5 4.5 - 5.5 488 30 ±5.0 ±200.0 ±20.0 15 5 4.5 - 5.5 482 30 ±9.0 ±111.0 ±12.0 15 5 4.5 - 5.5 470 30 ±12.0 ±83.0 ±9.0 15 5 4.5 - 5.5 470 30 ±15.0 ±67.0 ±7.0 15 12 10.8 - 13.2 203 15 5.0 400.0 40.0 15 12 10.8 - 13.2 201 15 9.0 222.0 23.0 15 12 10.8 - 13.2 196 15 12.0 167.0 17.0 15 12 10.8 - 13.2 196 15 15.0 133.0 14.0 15 12 10.8 - 13.2 201 15 ±5.0 ±200.0 ±20.0 15 12 10.8 - 13.2 198 15 ±9.0 ±111.0 ±12.0 15 12 10.8 - 13.2 194 15 ±12.0 ±83.0 ±9.0 15 12 10.8 - 13.2 194 15 ±15.0 ±67.0 ±7.0 15 24 21.6 - 26.4 100 8 5.0 400.0 40.0 15 24 21.6 - 26.4 99 8 9.0 222.0 23.0 15 24 21.6 - 26.4 97 8 12.0 167.0 17.0 15 24 21.6 - 26.4 97 8 15.0 133.0 14.0 15 24 21.6 - 26.4 99 8 ±5.0 ±200.0 ±20.0 15 24 21.6 - 26.4 98 8 ±9.0 ±111.0 ±12.0 15 24 21.6 - 26.4 96 8 ±12.0 ±83.0 ±9.0 15 24 21.6 - 26.4 96 8 ±15.0 ±67.0 ±7.0 15 Efficiency (%, Typ) 81 82 84 84 82 83 85 85 82 83 85 85 83 84 86 86 83 84 86 86 84 85 87 87 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 500 250 250 250 250 250 250 250 250
Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. An input capacitor will enhance stability over temperature and input line variations. Recommended capacitor values are given in the table below. For applications requiring very low output noise levels, a simple LC filter should be effective. Output Capacitor Input Vin Vout Capacitor Single Dual 5 VDC 4.7 µF 5 VDC 10.0 µF 4.7 µF 12 VDC 2.2 µF 9 VDC 4.7 µF 2.2 µF 24 VDC 1.0 µF 12 VDC 2.2 µF 1.0 µF 15 VDC 1.0 µF 0.47 µF 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin 1 7 8 Single -Vin NC -Vout Dual -Vin NC Common Pin 9 11 14 Single +Vout No Pin +Vin Dual +Vout -Vout +Vin
Notes:
• All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the top of the unit