H100I Series
Ultra-Miniature MiniDIP 1W, High Isolation DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
New Models!!
Min. 5 VDC Input 4.5 10.8 21.6 12 VDC Input 24 VDC Input Typ. 5.0 12.0 24.0 Max. 5.5 13.2 26.4 0.3 A Units % % % 100 120 ±0.01 Momentary (0.5 Sec.) ±0.02 mV P - P % %/ºC VDC Units
Key Features:
• 1W Output Power • Miniature MiniDIP Case • 3,000 VDC Isolation • Complies to RFI Standards • >2 MHour MTBF • 18 Standard Models • Industry Standard Pin-Out
Input
Parameter Input Voltage Range Input Filter Reverse Polarity Input Current Conditions
Internal Capacitor
Output
Parameter Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit For Vin Change of 1% Iout = 20% to 100% Conditions Min. Typ. ±1.0 ±1.2 ±8.0 Max. ±3.0 ±1.5
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI/RFI Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 3,000 1,000 60 80 100 Typ. Max. Units VDC MΩ pF kHz
EN55022 A, EN55024 A, IEC 61000-4-2, IEC 61000-4-3, FCC 47 CFR Part 15 B Conditions Case -40 Free Air Convection RH, Non-condensing 95 % Min. -40 Typ. +25 Max. +85 +100 +125 Units
ºC
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling
ºC
ºC
MicroPower Direct
292 Page Street Ste D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Humidity
Physical
Case Size Case Material Weight 0.50 x 0.40 x 0.27 Inches (12.70 x 10.16 x 6.85 mm) Non-Conductive Black Plastic (UL94-V0) 0.06 Oz (1.8g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Conditions 5 VDC Input Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec All Models Min. 2.0 Min. -0.7 -0.7 -0.7 Typ. Max. 7.0 15.0 28.0 260 450 ºC mW VDC Typ. Max. Units MHours Units
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number H101I H102I H103I H104I H105I H106I H111I H112I H113I H114I H115I H116I H121I H122I H123I H124I H125I H126I Input Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 5 4.5 - 5.5 278 25 5 4.5 - 5.5 267 25 5 4.5 - 5.5 260 25 5 4.5 - 5.5 256 25 5 4.5 - 5.5 257 25 5 4.5 - 5.5 257 25 12 10.8 - 13.2 116 16 12 10.8 - 13.2 112 16 12 10.8 - 13.2 109 16 12 10.8 - 13.2 107 16 12 10.8 - 13.2 107 16 12 10.8 - 13.2 107 16 24 21.6 - 26.4 58 8 24 21.6 - 26.4 56 8 24 21.6 - 26.4 55 8 24 21.6 - 26.4 54 8 24 21.6 - 26.4 54 8 24 21.6 - 26.4 54 8 Voltage (VDC) 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 3.3 5.0 9.0 12.0 15.0 24.0 Output Current (mA, Max) 300.0 200.0 111.0 83.3 66.6 41.6 300.0 200.0 111.0 83.3 66.6 41.6 300.0 200.0 111.0 83.3 66.6 41.6 Current (mA, Min) 5.0 4.0 2.0 2.0 2.0 2.0 5.0 4.0 2.0 2.0 2.0 2.0 5.0 4.0 2.0 2.0 2.0 2.0 Efficiency (%, Typ) 72 75 77 78 78 78 72 75 77 78 78 78 72 75 77 78 78 78 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 500 200 200 200 200 200 200 100 100 100 100 100 100
Other outputs are available. Contact the factory for details at: sales@micropowerdirect.com
Notes: 1. Output load regulation is specified for a load change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The 5V, 12V and 24V input units do not require external components to operate, but the use of a low ESR capacitor (approximately 10 uF, ESR
很抱歉,暂时无法提供与“H100I”相匹配的价格&库存,您可以联系我们找货