0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LF717RW

LF717RW

  • 厂商:

    MPD

  • 封装:

  • 描述:

    LF717RW - Wide Input, 7.5W SMT Single & Dual Output DC/DC Converters - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
LF717RW 数据手册
LF700RW Series Wide Input, 7.5W SMT Single & Dual Output DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: • 7.5W Output Power • Wide 2:1 Inputs • Miniature SMT Case • Tight Line/Load Regulation • 1,500 VDC Isolation • -40ºC to +60ºC Operation • 21 Standard Models • 1.0 MH MTBF Minimum • Industry Standard Pin-Out Parameter Input Start Voltage Reverse Polarity Input Current Short Circuit Input Power Input Filter Conditions 12 VDC Input 24 VDC Input 48 VDC Input Max. 9.0 18.0 36.0 1.0 1,000 3,000 π (Pi) Filter (Meets EN55022 Class A) Min. Typ. ±0.5 ±0.5 ±0.1 ±0.3 50 Max. ±1.0 ±2.0 ±0.3 ±1.0 85 100 15 165 500 ±6 ±0.02 Min. 7.5 14.0 30.0 Typ. 8.0 16.0 33.0 Units VDC A mW Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Response Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Dual Output, Balanced Load For Vin = Min to Max Iout = 20% to 100% Units % % % % mV P - P mV P - P mV rms % μS % %/ºC 115 25% Load Step Change 140 250 ±2 ±0.01 Continuous Conditions 60 Seconds 1,000 VDC 100 kHz, 1V Min. 1,500 1,000 200 Conditions Typ. Max. Units VDC MΩ pF kHz Units ºC ºC ºC % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency 650 260 750 350 Max. +60 +90 +125 95 Environmental RoHS Compliant MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Ambient Case Physical Case Size Case Material Weight 1.31 x 0.81 x 0.40 Inches (33.4 x 20.6 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.49 Oz (14g) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. 1.0 Min. -0.7 -0.7 -0.7 Typ. Max. Units MHours Units VDC ºC mW Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Typ. Max. 25.0 50.0 100.0 260 2,500 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number LF701RW LF702RW LF703RW LF704RW LF705RW LF706RW LF707RW LF711RW LF712RW LF713RW LF714RW LF715RW LF716RW LF717RW LF721RW LF722RW LF723RW LF724RW LF725RW LF726RW LF727RW Input Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 12 9.0 - 18.0 417 25 12 9.0 - 18.0 595 25 12 9.0 - 18.0 718 25 12 9.0 - 18.0 710 25 12 9.0 - 18.0 496 25 12 9.0 - 18.0 717 25 12 9.0 - 18.0 710 25 24 18.0 - 36.0 206 10 24 18.0 - 36.0 294 10 24 18.0 - 36.0 355 10 24 18.0 - 36.0 355 10 24 18.0 - 36.0 245 10 24 18.0 - 36.0 355 10 24 18.0 - 36.0 351 10 48 36.0 - 75.0 103 8 48 36.0 - 75.0 147 8 48 36.0 - 75.0 178 8 48 36.0 - 75.0 178 8 48 36.0 - 75.0 123 8 48 36.0 - 75.0 178 8 48 36.0 - 75.0 178 8 Voltage (VDC) 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 Output Current (mA, Max) 1,200 1,200 625 500 ±500 ±312 ±250 1,200 1,200 625 500 ±500 ±312 ±250 1,200 1,200 625 500 ±500 ±312 ±250 Current (mA, Min) 90.0 60.0 32.0 25.0 ±25.0 ±15.5 ±12.5 90.0 60.0 32.0 25.0 ±25.0 ±15.5 ±12.5 90.0 60.0 32.0 25.0 ±25.0 ±15.5 ±12.5 Efficiency (%, Typ) 79 84 87 88 84 87 88 80 85 88 88 85 88 89 80 85 88 88 85 88 88 Fuse Rating Slow-Blow (mA) 1,500 1,500 1,500 1,500 1,500 1,500 1,500 700 700 700 700 700 700 700 350 350 350 350 350 350 350 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 μF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR
LF717RW 价格&库存

很抱歉,暂时无法提供与“LF717RW”相匹配的价格&库存,您可以联系我们找货

免费人工找货