MPA600RX-24ZZ

MPA600RX-24ZZ

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPA600RX-24ZZ - Industrial 600W Single Output Power Factor Corrected AC/DC Power Supplies - MicroPow...

  • 详情介绍
  • 数据手册
  • 价格&库存
MPA600RX-24ZZ 数据手册
MPA600R Series Industrial 600W Single Output Power Factor Corrected AC/DC Power Supplies Key Features: • 600W Output Power • Universal 90-264V AC Input • PFC to EN61000-3-2 “D” • UL, cUL, TUV Approvals • CE Certified • FCC Class B Emissions • 2 - 56 V Output Voltages • N+1 Current Share Option • Three Mechanical Options Electrical Specifications Input Parameter Input Voltage Range Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current (Note 1) Power Factor Correction Input Protection Conditions Universal Min. 90 47 Typ. NEW Industrial Power!! Max. 264 63 Units VAC Hz A A mA Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change wi h notice. change without notice ithout notice. i 90 - 264 VAC 10 110 VAC 17.5 220 VAC 35 240 VAC 1.5 Active, Meets EN61000-3-2 Class D T10A/250V Fuse Typ. Max. ±5.0 ±1.0 80% Load 20 See Model Selection Guide Power Limit 110 140 >130% of Rated Output Voltage. Recycle AC Input. >+85ºC Ambient with Autorecovery ±0.04 2.5 50% Load Change 5 At Turn On/Off 5.0 120 VAC 1 Continuous With Autorecovery By Trim Pot Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Conditions Min. Output Parameter Output Voltage Adjustment Output Regulation (Note 2) Hold Time Ripple & Noise (20 MHz) (Note 3) Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time (Note 4) Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Units % % mSec % %/ºC mS % % S General Parameter Isolation Voltage Switching Frequency Units VAC 23 kHz Interface Signals Power Supply On MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Power Good Signal Current Sharing Current Monitor Remote Sense Remote On/Off Green LED (LED1) on the PCB PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. CSH on CN3. Single wired, forced current sharing option. Up to four units may be connected in parallel within 10% accuracy at full load. CMN on CN3. A 0.5V to 3.0V output that represents 0% to 100% of the unit output current RS + and RS- on CN3. Compensates for up to a 0.5V line drop. (not on models with current share option) RSW on CN3. A TTL low signal inhibits the output Conditions Min. Typ. Max. Ambient 0 +25 +50 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 See Model Selection Guide RH, Non-condensing 90 Units ºC ºC % Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Reliability Specifications Parameter MTBF Safety Standards EMI Compliance EMS Immunity Compliance Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 150 kHours UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950) Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD) Model Selection Guide Model Number MPA600Rx-03zz MPA600Rx-05zz MPA600Rx-12zz MPA600Rx-18zz MPA600Rx-24zz MPA600Rx-36zz MPA600Rx-48zz Output Voltage Factory Range (Note 5) PreSet 3.3 VDC 2.0 - 3.3 VDC 5 VDC 5.0 - 6.0 VDC 12 VDC 12.0 - 15.0 VDC 18 VDC 16.0 - 21.0 VDC 24 VDC 22.0 - 30.0 VDC 36 VDC 31.0 - 47.0 VDC 48 VDC 48.0 - 56.0 VDC Output Current (Notes 6, 7, 8) ( U” units) Max. “ “E” Units Min with 30 CFM Int. Fan 90.00A 0.0A 90.00A 90.00A 0.0A 90.00A 50.00A 0.0A 50.00A 37.50A 0.0A 37.50A 27.27A 0.0A 27.27A 19.35A 0.0A 19.35A 12.50A 0.0A 12.50A Ripple & Noise 75 mV p-p 75 mV p-p 1% p-p 1% p-p 1% p-p 1% p-p 1% p-p Efficiency (Note 7) Input Connector CN1: U-Chassis (U,C) Howder Terminal Block No. HD-121-3P (3-pin) or Mating Molex Part No. 09-91-0700 (7 pin, 5 used) or equivalent. Enclosed with Fan (E) Dinkle Terminal Block No. DT-35-A02W-3 (3-pin) or IEC 320 or equivalent snap-in mounting type. Output Connector CN2: Howder Terminal Block No. HD-121-8P (8-pin) or Mating Molex Part No. 09-91-2000 (20 pin) or equivalent. Output Pin Assignment: Howder Pins 1 ~ 4: V+ Pins 5 ~ 8: VMolex Pins 1 ~ 10: V+ Pins 11 ~ 20: V- 70% 75% 80% 83% 83% 83% 83% Notes: 1. Models are available with leakage current specified as low as 750 µA. Contact the factory for details. 2. Output regulation includes line & load. 3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 4. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting the agency certification. Contact the factory for details. 6. A minimum load of 1% is required to maintain load regulation and ripple specifications. 7. Output current is given for the factory preset voltage. With the exception of the “03” (297W) and “05” (450W) output models, the maximum continuous output power level is 600W with 30 CFM. For more information, contact the factory. 8. Units will provide peak power of 900W for 500 µS. For units capable of longer durations, contact the factory. Logic Signal Connector CN3: Mating JST XHP-7 or equivalent (CHYAO SHIUNN JS-2001-07). Fan driver connector (FAN): 12 VDC / 500 mA is available to drive an external fan. Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mechanical Dimensions: U-Chassis (U Suffix) Enclosure With Fan (E Suffix) U-Chassis Cover (C Suffix) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPA600RX-24ZZ
### 物料型号 - 型号:MPA600R

### 器件简介 - MPA600R是一款工业级600W单输出电源模块,具有以下特点: - 600W输出功率 - 通用90-264V交流输入 - 功率因数校正(PFC)符合EN61000-3-2 “D”标准 - 获得UL、cUL、TÜV认证 - CE认证 - FCC Class B辐射 - 输出电压2-56V - N+1电流共享选项 - 三种机械选项

### 引脚分配 - 输入连接器CN1:U-Chassis (U,C) Howder Terminal Block No. HD-121-3P (3-pin) 或Molex Part No. 09-91-0700 (7 pin, 5 used) 或等效品。 - 输出连接器CN2:Howder Terminal Block No. HD-121-8P (8-pin) 或Molex Part No. 09-91-2000 (20 pin) 或等效品。 - 逻辑信号连接器CN3:Mating JST XHP-7或等效品(CHYAO SHIUNN JS-2001-07)。

### 参数特性 - 输入电压范围:90-264VAC - 输入频率:47-63Hz - 输入电流(满载):10A - 功率因数校正:主动式,符合EN61000-3-2 Class D - 输出电压调整:通过电位器调整,±5.0% - 输出调节:±1.0% - 保持时间:20ms - 纹波和噪声(20MHz):详见型号选择指南 - 过载保护:110%至140%额定输出功率 - 过电压保护:>130%额定输出电压,重新启动交流输入 - 过温保护:>+85°C环境温度,自动恢复

### 功能详解 - MPA600R支持电流共享和远程感测功能,可通过CN3接口实现。 - 具有多种保护功能,包括过载、过电压、过温和短路保护。 - 支持瞬态恢复和响应,以及启动延迟和输出短路保护。

### 应用信息 - 适用于需要高功率输出和高效率的工业应用场合。

### 封装信息 - 提供U-Chassis (U后缀)、带风扇的外壳(E后缀)和U-Chassis Cover (C后缀)三种机械选项。
MPA600RX-24ZZ 价格&库存

很抱歉,暂时无法提供与“MPA600RX-24ZZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货