MPE-100FS-12

MPE-100FS-12

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPE-100FS-12 - Single Output, 100W Compact, Enclosed AC/DC Power Supplies - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
MPE-100FS-12 数据手册
MPE-100FS Series Si l Output, 100W Single O t t 100W Compact, Enclosed AC/DC Power Supplies Electrical Specifications Key Features: • 100W Output Power • Selectable 88-264 AC Input • EN60950 Approved • Wide Temp Operation • Seven Single Output Models • Meets EN55022 • >300 kHour MTBF • Compact Metal Enclosure Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current Conditions Min. Typ. 88 115 Switch Selectable 176 220 248 47 See Model Selection Guide Cold Start, 115 VAC 30.0 Cold Start, 230 VAC 60.0 115 VAC 240 VAC Max. 132 264 370 63 Units VAC VDC Hz A Pk 0.7 1.0 Max. mA Units Output Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 15 230 VAC 20 230 VAC 1,000 230 VAC 30 ±0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 135 Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ. mSec mSec mSec %/°C 135 165 Max. % % Units VAC RoHS Compliant General Parameter Isolation Voltage Isolation resistance EMI/RFI MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com EMC Compliance Switching Frequency 100 MΩ EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 75 kHz Max. +60 +85 95 Units °C °C % Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. -10 +25 -20 Free Air Convection RH, Non-condensing Ambient Physical Case Size Case Material Weight 7.83 x 3.86 x 1.50 Inches (199.0 x 98.0 x 38.0 mm) Vented Metal Enclosure 22.9 Oz (0.65 kg) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 300 kHours CAN/CSA-C22.2 No 60950-1-03, ANSI/UL Std No 60950-1, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Reliability Specifications Parameter MTBF Safety Standards Vibration Model Selection Guide Model Number MPE-100FS-05 MPE-100FS-7.5 MPE-100FS-12 MPE-100FSS-15 MPE-100FS-24 MPE-100FS-27 MPE-100FS-48 Input Current (A) 115 VAC 3.15 3.15 3.15 3.15 3.15 3.15 3.15 230 VAC 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Output Voltage (VDC) Rated 5.0 7.5 12.0 15.0 24.0 27.0 48.0 Adjust 4.5 - 5.5 6.75 - 8.25 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 24.3 - 29.7 43.2 - 52.8 Current (A) Rated 20.0 13.5 8.5 6.7 4.5 3.5 2.2 Range 0 to 20.0 0 to 13.5 0 to 8.5 0 to 6.7 0 to 4.5 0 to 3.5 0 to 2.2 Output Tolerance (%) ±2.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 ±1.0 Ripple & Noise (mV p-p) Efficiency (%, Typ) 100 125 125 125 150 150 150 76 78 80 81 83 83 84 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. The overload protection circuit shuts down the output. The unit recovers automatically when the fault condition is removed. 5. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-100FS series, a 7.5A/250 VAC slow blow should be used. Mechanical Dimensions Pin Connections Pin 1 2 3 4 5 6 7 Function AC-Line AC-Neutral AC-Ground -Vout -Vout +Vout +Vout Derating Curve Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) Static Characteristics MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPE-100FS-12 价格&库存

很抱歉,暂时无法提供与“MPE-100FS-12”相匹配的价格&库存,您可以联系我们找货

免费人工找货