0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPO-65S-27

MPO-65S-27

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPO-65S-27 - Single Output, 65W Compact, Open Frame AC/DC Power Supplies - MicroPower Direct, LLC

  • 数据手册
  • 价格&库存
MPO-65S-27 数据手册
MPO-65S Series Si l O Single Output, 65W 6 Compact, Open Frame AC/DC Power Supplies Electrical Specifications Key Features: • 65W Output Power • Universal 90-264 AC Input • EN 60950 Compliant • Low Leakage Current • Nine Single Output Models • Meets EN55022 • >300 kHour MTBF • Only 5” x 3” x 1.6” Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Input Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current Conditions Min. Typ. 90 127 47 See Model Selection Guide Cold Start, 115 VAC 20.0 Cold Start, 230 VAC 40.0 115 VAC 0.35 240 VAC 0.5 Universal Max. 264 370 63 Units VAC VDC Hz A Pk mA Max. Units Output Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz), See Note 2 Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 15 230 VAC 60 230 VAC 800 230 VAC 20 ±0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 112 Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Fixed Conditions Min. 3,000 1,500 500 Typ. mSec mSec mSec %/°C 135 160 Max. % % Units VAC RoHS Compliant General Parameter Isolation Voltage Isolation resistance EMI/RFI MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com EMC Compliance Switching Frequency 100 MΩ EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 65 kHz Units °C °C % Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 95 Ambient Physical Size Weight 5.00 x 3.00 x 1.65 Inches (127.0 x 76.2 x 42.0 mm) 7.4 Oz (0.21 kg) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25°C, Gnd Benign 300 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis Reliability Specifications Parameter MTBF Safety Standards Vibration Model Selection Guide Model Number MPO-65S-3.3 MPO-65S-05 MPO-65S-7.5 MPO-65S-12 MPO-65S-13.5 MPO-65S-15 MPO-65S-24 MPO-65S-27 MPO-65S-48 Input Current (A) 115 VAC 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 1.20 230 VAC 0.72 0.72 0.72 0.72 0.72 0.72 0.72 0.72 0.72 Output Voltage (VDC) Rated 3.3 5.0 7.5 12.0 13.5 15.0 24.0 27.0 48.0 Adjust 3.14 - 3.63 4.75 - 5.5 7.13 - 8.25 11.4 - 13.2 12.8 - 14.9 14.25 - 16.5 22.8 - 26.4 25.65 - 29.7 45.6 - 52.8 Current (A) Rated 12.0 12.0 8.0 5.2 4.7 4.2 2.7 2.4 1.3 Range 0 to 15.2 0 to 13.8 0 to 9.6 0 to 6.0 0 to 5.4 0 to 4.8 0 to 3.0 0 to 2.7 0 to 1.5 Output Tolerance (%) ±3.0 ±3.0 ±3.0 ±2.0 ±2.0 ±2.0 ±2.0 ±2.0 ±2.0 Ripple & Noise (mV p-p) Efficiency (%, Typ) 80 100 100 100 100 100 100 100 100 69 76 79 79 79 79 80 80 80 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 µF and a 47 µF capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. For the 3.3V output model, overload protection is set to operate between 36 to 55W. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the mechanical diagram for the correct rating. Mechanical Dimensions Pin Connections: CN1 (Molex 5277-02 or equiv.) Pin 1 2 Function Mating Housing Terminal AC-Neutral Molex 5195 Molex 5194 or Equiv. or Equiv. AC-Line Pin Connections: CN2 (Molex 5273-06 or equiv.) Pin 1, 2, 3 4, 5, 6 Function +Vout -Vout Mating Housing Terminal Molex 5195 Molex 5194 or Equiv. or Equiv. Output Derating vs Input Voltage Derating Curve Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPO-65S-27 价格&库存

很抱歉,暂时无法提供与“MPO-65S-27”相匹配的价格&库存,您可以联系我们找货

免费人工找货