SR7810
Electrical Specifications
Series
Low Cost, 1A Output Non-isolated POL Switching Regulators
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• Efficiency to 96% • 1A Output Current • Compact SIP Case • LM78xx Replacement • Wide Input Range • Short Circuit Protected • Thermal Shutdown • Low Noise
Output
Parameter Output Voltage Accuracy Line Regulation Load Regulation Ripple & Noise (20 MHz) Dynamic Load Stability Output Power Protection Thermal Shutdown Quiescent Current Output Current Limit Output Short Circuit Continuous (Autorecovery) See Note 2 See Note 3 See Note 1 120 150 5 7 2,000 Vin = Min to Max Iout = 10% to 100% Conditions Min. Typ. ±2.0 ±0.2 ±0.4 20 Max. ±3.0 ±0.4 ±0.6 35 ±100 Units % % % mV P - P mV % °C mA mA
General
RoHS Compliant
Parameter Isolation Voltage Switching Frequency
Conditions
Min. Not Isolated 280
Typ.
Max.
Units
330
450
kHz
Environmental
Parameter Operating Temperature Range Operating Temperature Range Conditions Ambient Case -55 1.5 mm From Case For 10 Sec Free Air Convection RH, Non-condensing 95 % Min. -40 Typ. +25 Max. +85 +100 +125 300 Units °C °C °C °C
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Storage Temperature Range Lead Temperature Cooling Humidity
Physical
Case Size Case Material Weight 0.45 x 0.35 x 0.69 Inches (11.5 x 8.90 x 17.50 mm) Non-Conductive Black Plastic (UL-94V0) 0.13 Oz (3.7g)
Reliability Specifications
Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 2.0 Typ. Max. Units MHours
Model Selection Guide
Model Number SR7810-03W SR7810-05W SR7810-06W SR7810-09W SR7810-12W Input Voltage Range (VDC) 4.75 - 28.0 6.5 - 32.0 9.0 - 32.0 12.0 - 32.0 16.0 - 32.0 Output Efficiency (%, Typ) Voltage Current (VDC) (mA, Max) Min Vin Max Vin 3.3 1,000.0 90 83 5.0 1,000.0 93 88 6.5 1,000.0 94 90 9.0 1,000.0 95 92 12.0 1,000.0 96 94
Typical Application Circuit
Notes: 1. Dynamic load stability is specified for output loads from 10% to 100%. 2. Measured at an internal IC junction. 3. Quiescent current is specified at 0% load for Vin = min to max. 4. This regulator is not designed to be used in parallel with another unit to increase output power. 5. The input should not exceed the range given in the model selection chart above. Exceeding this limit could damage the unit.
Derating Curve
Notes: 1. C1 is a low ESR ceramic capacitor used to minimize noise at the regulator. A tantalum or low ESR electrolytic capacitor may also be used. A typical value is 22 µF/50V. C1 should be placed as close to pins 1 and 2 as possible. 2. C2 is optional. A typical value is a 100 µF/25V electrolytic capacitor.
Mechanical Dimensions
Pin Connect.
Pin 1 2 3 Description +Vin Gnd +Vout
Characteristic Curves (Efficiency & Ripple)
Efficiency vs Input Voltage (Full Load)
Efficiency vs Load (Vin = Min)
Efficiency vs Load (Vin = Max)
Ripple vs Input Voltage (Full Load)
Ripple vs Load (Vin = Min)
Ripple vs Load (Vin = 24V)
Notes:
• All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is m marked by a “dot” or indentation on the sid of the unit on the side
MicroPower Direct
www.micropowerdirect.com
•
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com
很抱歉,暂时无法提供与“SR7810-09W”相匹配的价格&库存,您可以联系我们找货
免费人工找货