0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HFC0300HS-LF

HFC0300HS-LF

  • 厂商:

    MPS(美国芯源)

  • 封装:

    SOIC8_150MIL_7引线

  • 描述:

    ICREGCTRLRPWM7SOIC

  • 数据手册
  • 价格&库存
HFC0300HS-LF 数据手册
HFC0300 Variable Off Time Controller The Future of Analog IC Technology DESCRIPTION HFC0300 is a variable off-time controller that uses a fixed-peak–current technique to decrease its frequency as the load lightens. As a result, it offers excellent efficiency at light-load while optimizing the efficiency under other load conditions. When the frequency decreases to threshold, the peak current decreases with the decreasing load to prevent mechanical resonance in the transformer. The controller enters burst mode when the output power falls below a given level. The HFC0300 features various protections such as thermal shutdown, VCC under-voltage lockout, overload protection, short-circuit protection, and over-voltage protection. The HFC0300 is available in SOIC-7 package. FEATURES • • • • • • • • • • • • • Variable Off-Time, Current Mode Control Universal Main Supply Operation (85VAC to 265VAC) Frequency Foldback as Load Lightens Peak-Current Compression to Reduce Transformer Noise Active-Burst Mode for Low Standby Power Consumption Internal High-Voltage Current Source Internal 200ns Leading Edge Blanking Thermal Shutdown (Auto Restart with Hysteresis) VCC Under-Voltage Lockout with Hysteresis Over-Voltage Protection on VCC Pin Timer-Based Overload Protection Short-Circuit Protection Natural Spectrum Shaping for Improved EMI Performance APPLICATIONS • • • Battery Charger for Portable Electronics Standby Power Supply Switched-Mode Power Supplies All MPS parts are lead-free and adhere to the RoHS directive. For MPS green status, please visit MPS website under Products, Quality Assurance page. “MPS” and “The Future of Analog IC Technology” are registered trademarks of Monolithic Power Systems, Inc. HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 1 HFC0300– VARIABLE OFF TIME CONTROLLER TYPICAL APPLICAION HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 2 HFC0300– VARIABLE OFF TIME CONTROLLER ORDERING INFORMATION Part Number* Package SOIC-7 HFC0300HS Top Marking HFC0300 * For Tape & Reel, add suffix –Z (e.g. HFC0300HS–Z); For RoHS compliant packaging, add suffix –LF (e.g. HFC0300HS–LF–Z) PACKAGE REFERENCE TOP VIEW DRV 1 8 HV CS 2 GND 3 6 VCC COPM 4 5 FSET SOIC-7 (4) ABSOLUTE MAXIMUM RATINGS (1) Thermal Resistance HV Breakdown Voltage............. -0.7V to +700V VCC, DRV to GND....................... -0.3V to +30V DRV to GND ................................ -0.3V to +18V FSET, COMP, CS to GND ............. -0.3V to +7V (2) Continuous Power Dissipation (TA = +25°C) SOIC-7……………………………………....1.3W Junction Temperature.............................. 150°C Thermal Shut Down ................................. 150°C Thermal Shut Down Hysteresis.................. 25°C Lead Temperature ................................... 260°C Storage Temperature .............. -60°C to +150°C ESD Capability Human Body Model (All Pins except Drain) ...........................................2.0kV ESD Capability Machine Model..................200V Notes: 1) Exceeding these ratings may damage the device. 2) The maximum allowable power dissipation is a function of the maximum junction temperature TJ (MAX), the junction-toambient thermal resistance θJA, and the ambient temperature TA. The maximum allowable continuous power dissipation at any ambient temperature is calculated by PD (MAX) = (TJ (MAX)-TA)/θJA. Exceeding the maximum allowable power dissipation will cause excessive die temperature, and the regulator will go into thermal shutdown. Internal thermal shutdown circuitry protects the device from permanent damage. 3) The device is not guaranteed to function outside of its operating conditions. 4) Measured on JESD51-7, 4-layer PCB. θJA θJC SOIC-7 ...................................96 ...... 45 ...°C/W Recommended Operation Conditions (3) Operating Junction Temp. (TJ)..... -40°C to +125°C Operating Vcc range....................... 8.2V to 20V HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 3 HFC0300– VARIABLE OFF TIME CONTROLLER ELECTRICAL CHARACTERISTICS VCC=12V, TA=25°C, unless otherwise noted. Parameter Symbol Conditions Supply Current from Pin HV IHV VHV=400V, Vcc=6V Break-Down Voltage VBR Min Typ Max Unit Start-up Current Source (Pin HV) Off-State HV Leakage Current Supply Voltage Management (Pin VCC) VCC Increasing Level where the Current Source Turns Off VCC Decreasing Level where the Current Source Turns On Vcc Re-Charge Level where Protections Occurs ILeak mA 700 VHV=400V, Vcc=10V V 10 17 μA VCCOFF 10.7 11.7 12.7 V VCCON 7.6 8.2 8.8 V VCCR 5.0 5.5 6.0 V VCC Decreasing Level where Latch-Off Phase Ends VCClatch Internal IC Consumption ,1nF Load on DRV Pin Icc Internal IC Consumption, Latch off Phase Rising Voltage Threshold on VCC where Controller Latches Off (OVP) Integration Time Constraint on the OVP Comparator Timing Capacitor(Pin FSET) Minimum Voltage on FSET Capacitor Maximum Voltage on FSET Capacitor Source Current FSET Capacitor Discharge Time (Active at Drive Turn-On) Feedback Management (Pin COMP) Icclatch fs=65kHz, Vcc=12V Vcc=6V VOVP 22.5 tINT 0.82 23 tDISCH VOLP Over Load Protection Delay Time tOLP 3.0 V 1.3 mA 500 μA 24 25.5 20 VFSETmin VFSETmax IFSET Over Load Protection Set Point COMP Decreasing Level where the Controller Enters the Burst Mode COMP Increasing Level where the Controller Leaves the Burst Mode 2 0.88 3.2 28 μs 0.94 33 0.6 0.80 CFSET=330pF 0.85 V V V μA μs 0.90 74 V ms VBURH 3.0 3.2 3.4 V VBURL 2.9 3.1 3.3 V Current Sampling Management (Pin CS) Short-Circuit Comparator Leading-Edge Blanking Current-Sense Comparator Leading-Edge Blanking Maximum Current-Sense Comparator Limit Short-Circuit Protection Point tLEB1 150 ns tLEB2 200 ns VLimit VSCP VCOMP=1V VSCP 0.45 0.5 1.0 HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved -0.55 V V 4 HFC0300– VARIABLE OFF TIME CONTROLLER ELECTRICAL CHARACTERISTICS (continued) VCC=12V, TA=25°C, unless otherwise noted. Parameter Symbol Driving Signal (Pin DRV) Sourcing Resistor Sinking Resistor VDRIVE Clamp Conditions RH RL VDRIVE Vcc=18V Min Typ 10 3 13.7 Max Unit Ω Ω V PIN FUNCTIONS SOIC-7 Pin # Name Description 1 2 3 DRV CS GND 4 COMP 5 FSET 6 VCC 8 HV Drive. Output of the drive signal. Current Sense Input. Ground. Switching Frequency Set. A feedback voltage of 0.85V will trigger overload protection, and a feedback voltage of 3.1V will trigger a burst mode operation. Frequency Set. Maximum switching frequency set by a capacitor. IC Supply. Connected to an external bulk capacitor. If an auxiliary winding brings this pin above 24V, the controller latches off. High-Voltage Source. Input for the start-up high voltage current source. HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved 5 HFC0300– VARIABLE OFF TIME CONTROLLER TYPICAL PERFORMANCE CHARACTERISTICS 2.7 12 8.5 11.75 8.25 V CCH (V) 2.3 2.1 1.9 0 8 7.75 11 -40 -20 0 20 40 60 80 100 120 7.5 -40 -20 0 20 40 60 80 100 120 20 40 60 80 100 120 78 24.5 0.86 76 24.3 0.84 74 24.1 0.82 0.8 VOVP(V) 0.88 TOCP(ms) VOLP(V) 11.5 11.25 1.7 1.5 -40 -20 V CCL(V) 2.5 72 23.7 70 0.78 -40 -20 0 20 40 60 80 100 120 68 -40 -20 0.88 30 0.875 29 0.87 28 0.865 27 23.9 23.5 -40 -20 0 0 20 40 60 80 100 120 20 40 60 80 100 120 0.51 0.5 IPEAK(V) FSETMIN(V) 0.505 0.495 0.49 0.485 0.86 -40 -20 0 20 40 60 80 100 120 26 -40 -20 0 20 40 60 80 100 120 0.48 -40 -20 0 20 40 60 80 100 120 HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved 6 HFC0300– VARIABLE OFF TIME CONTROLLER TYPICAL PERFORMANCE CHARACTERISTICS (continued) SCP Point vs. Temperature Comp Increasing Level Comp Decreasing Level at which the Controller Enters at which the Controller Leaves the Burst Mode vs. Temperature the Burst Mode vs. Temperature 0.95 0.93 3.25 3.16 3.23 3.14 0.89 3.21 0 20 40 60 80 100 120 3.17 -40 -20 0 20 3.12 3.1 3.19 0.87 0.85 -40 -20 VBURL(V) VBURH(V) IPEAK(V) 0.91 40 60 80 100 120 3.08 -40 -20 0 20 40 60 80 100 120 HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved 7 HFC0300– VARIABLE OFF TIME CONTROLLER BLOCK DIAGRAM Power Management VCC(6) OTP OVP GND(3) OLP COMP(4) Fault Management Burst Mode Control Peak Current Compression FSET(5) Frequency Control Start Up Unit HV(8) Internal Power Supply Driving Signal Management DRV(1) Current Comparator CS(2) Figure 1: Functional Block Diagram HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved 8 HFC0300– VARIABLE OFF TIME CONTROLLER OPERATION The HFC0300 incorporates all the necessary features to build a reliable Switched-Mode Power Supply (SMPS). Its high level of integration requires few external components. Based on a fixed peak current technique, the controller decreases its frequency with the decreasing load to minimize switching loss. When the output power falls below a given level, the controller enters burst mode. It also has better EMI performance because the switching frequency varies with the natural bulk ripple voltage. Frequency Foldback A capacitor connected to the FSET pin sets the frequency at the end of charging. This capacitor charges from a constant current source and its voltage is compared with an internal threshold fixed by COMP voltage (see Figure 2). When this capacitor voltage reaches threshold, the capacitor discharges rapidly down to 0V, and a new period starts after a 0.6μs delay (see Figure 3). Start-up and Under Voltage Lock-out Initially, the internal high voltage current source drawn from the high-voltage (HV) pin powers the IC. The IC starts switching and the internal highvoltage current source turns off as soon as the voltage on VCC reaches 11.7V. Then the auxiliary winding of the transformer supplies the IC before the VCC voltage falls back below 8.2V. Otherwise, the switching pulse stops and the high-voltage current source turns on again. Figure 4 shows the typical waveform with VCC under-voltage lockout (UVLO). The auxiliary winding takes over VCC VCCH=11.7V VCCL=8.2V ON Internal Current Source OFF FSET Driving Signal 0.6µs pulse 28µA VCC S VOFFSET 0.88V R Q _ Q Drive COMP 3.3V Figure 2: Voltage-Controlled Oscillation Vfset Controlled by the COMP Voltage Minimum Frequency Pout Decrease IFSET=28µA Pout Increase Maximum Frequency Figure 3: COMP-Voltage–Adjusted Switching Frequency Figure 4: VCC Under-Voltage Lockout The lower threshold of VCC UVLO goes from 8.2V to 5.5V when fault conditions happen, such as over-load protection (OLP), over-voltage protection (OVP), and over-temperature protection (OTP). Over-Voltage Protection By monitoring the VCC pin with a 20µs timeconstant filter, the HFC0300 goes into latched fault condition whenever an over-voltage condition occurs—if VCC goes above 24V, typically. The controller stays fully latched in this position until the VCC is cycled down to 3.0V, e.g. when the user unplugs the power supply from the main input and re-plugs it. Over-Load Protection In a flyback converter, the maximum output power is limited by the maximum switching frequency and primary peak current. As the primary peak current is constant, the maximum power is limited by maximum frequency. When the switching frequency reaches the maximum, HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 9 HFC0300– VARIABLE OFF TIME CONTROLLER the output voltage decreases if the load continues to increase. COMP then drops below the over-load protection (OLP) point because feedback is equivalent to an open circuit. By continuously monitoring the COMP, when the COMP voltage drops below 0.85V—which is considered an error—the timer starts counting. If the error flag is removed, the timer resets. If the timer reaches completion at the delay time determined by the FSET capacitor (for example, 74ms at CFSET=330pF), OLP takes place. This timer avoids triggering OLP when the power supply is at start-up or load transition phase. Therefore the power supply should start-up in less than over load protection delay time, as determined by the following equation: t delay ≈ 74ms × CFSET 330pF Short Circuit Protection The HFC0300 shuts down when the CS voltage rises higher than 1V using short-circuit protection (SCP). As soon as the fault disappears, the power supply resumes operation. During SCP, the VCC UVLO lower threshold goes from 8.2V to 5.5V. Thermal Shutdown The HFC0300 shuts down switching when the inner temperature exceeds 150°C to prevent damaging high temperatures. As soon as the inner temperature drops below 125°C, the power supply resumes operation. During the thermal shutdown (TSD), the VCC UVLO lower threshold goes from 8.2V to 5.5V. Peak current compression As the load becomes lighter, the frequency decreases and may enter the audible range. To avoid exciting mechanical resonances in the transformer and generating acoustic noise, the HFC0300 reduces the peak current as power goes down and thus reduces noise issues. Peak Current(V) Peak Current Compression Constant Peak Current Burst Mode 0.5 0.167 2.1 0.9 3.1 3.2 COMP(V) Figure 5: Peak Current vs. COMP Burst Operation The HFC0300 enters burst-mode operation to minimize power dissipation in no load or light load conditions. As the load decreases, the COMP voltage increases; The IC stops switching when the COMP voltage increases over the threshold, VBRUH = 3.2V. The output voltage then drops, which causes the COMP voltage to decrease further. Once the COMP voltage falls below the threshold VBRUL = 3.1V, switching resumes and the COMP voltage then oscilates. The burst mode operation alternately enables and disables switching cycle of the MOSFET. Leading-Edge Blanking In order to avoid the premature termination of the switching pulse due to the parasitic capacitance, an internal leading-edge blanking (LEB) unit is employed between the CS pin and the current comparator input. During the blanking time, the current comparator is disabled and can not turn off the external MOSFET. Figure 6 shows the leading-edge blanking. VLimit TLEB=200nS Figure 5 shows the curve of peak current versus COMP. t Figure 6: Leading-Edge Blanking HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 10 HFC0300– VARIABLE OFF TIME CONTROLLER Start Y Internal High Voltage Current Source ON Shut Down Internal High Voltage Current Source Y Vcc>11.7V N Vcc Decrease to 5.5V Shut off the Switching Pulse Y Vcc24V Soft Start N Vcc3.2V 0.85V6,7 2mm 0.3mm*5 14 N4 2mm 2->1 2mm 0.3mm*1 42 1 1 3 3 3 Experimental Verification A physical prototype based on Figure 13 was used to verify both the design procedure presented in this application note, and the performance. The input ranged between 90VAC and 265VAC, and the output was at 24V/1.5A. The converter operates in BCM at 90VAC input and full load. Figure 17 and Figure 18 the current and drain voltage waveforms of the primary MOSFET. Figure 19 shows the burst mode function of the controller at light load. To minimize power dissipation at no load or light load, the HFC0300 enters burst-mode operation. As the load decreases, the COMP voltage increases. The HF0300 skips switching cycles when the COMP voltage increases over the threshold VBURH = 3.2V. The output voltage drops, causing the COMP voltage to decrease again. Once the COMP voltage falls below the threshold VBURL = 3.1V, switching resumes. The COMP voltage then rings. The burst mode operation alternately enables and disables switching cycles of the MOSFET thereby reducing switching loss in the no load or light load conditions. Figure 20 shows over-load protection. When COMP is low, the controller stops switching after 6000 switching cycles (about 100ms for this application) Figure 21 shows the measured efficiency. From the efficiency curve, the efficiency is still high at light load condition due to decreased switching frequency. Also the power consumption at no load is given in Table 2. In burst mode, the power loss with no load is very small, even with high line input. HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 17 HFC0300– VARIABLE OFF TIME CONTROLLER VDS CS Figure 17: Drain Current and Voltage of MOSFET at Low-Line Input (90VAC); CH2 - CS, CH3, VDS VDS CS Figure 18: Drain Current and Voltage of MOSFET at High-Line Input (230VAC); CS2 - CS, CH3 - VDS HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 18 HFC0300– VARIABLE OFF TIME CONTROLLER Figure 19: Burst Mode; CH2 - COMP, CH3 - DRV Vout DRV Iout COMP Figure 20: Overload Protection; CH1 - VOUT, CH2 - DRV, CH4 IOUT HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved 19 HFC0300– VARIABLE OFF TIME CONTROLLER 90.00% 88.00% Efficiency(%) 86.00% 84.00% 82.00% 80.00% 78.00% 76.00% 74.00% 72.00% 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 Output Current Io(A) Vin=115VAC Vin=230VAC Figure 21: Measured Efficiency Table 2: No-Load Loss at Different Line Voltages Input voltage (VAC, RMS) Power loss (mW) 90 115 230 265 74.4 77.2 110.1 121.9 HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 20 HFC0300– VARIABLE OFF TIME CONTROLLER PACKAGE INFORMATION SOIC-7 0.189(4.80) 0.197(5.00) 8 0.050(1.27) 0.024(0.61) 5 0.063(1.60) 0.150(3.80) 0.157(4.00) PIN 1 ID 1 0.228(5.80) 0.244(6.20) 0.213(5.40) 4 TOP VIEW RECOMMENDED LAND PATTERN 0.053(1.35) 0.069(1.75) SEATING PLANE 0.004(0.10) 0.010(0.25) 0.013(0.33) 0.020(0.51) 0.050(1.27) BSC 0.0075(0.19) 0.0098(0.25) SEE DETAIL "A" SIDE VIEW FRONT VIEW 0.010(0.25) x 45o 0.020(0.50) GAUGE PLANE 0.010(0.25) BSC 0o-8o 0.016(0.41) 0.050(1.27) DETAIL "A" NOTE: 1) CONTROL DIMENSION IS IN INCHES. DIMENSION IN BRACKET IS IN MILLIMETERS. 2) PACKAGE LENGTH DOES NOT INCLUDE MOLD FLASH , PROTRUSIONS OR GATE BURRS. 3) PACKAGE WIDTH DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSIONS. 4) LEAD COPLANARITY(BOTTOM OF LEADS AFTER FORMING) SHALL BE 0.004" INCHES MAX. 5) JEDEC REFERENCE IS MS-012. 6) DRAWING IS NOT TO SCALE. NOTICE: The information in this document is subject to change without notice. Users should warrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS products into any application. MPS will not assume any legal responsibility for any said applications. HFC0300 Rev. 1.01 www.MonolithicPower.com 1/28/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. 21
HFC0300HS-LF 价格&库存

很抱歉,暂时无法提供与“HFC0300HS-LF”相匹配的价格&库存,您可以联系我们找货

免费人工找货