0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MP6400DJ-12-LF-P

MP6400DJ-12-LF-P

  • 厂商:

    MPS(美国芯源)

  • 封装:

    SOT23-6

  • 描述:

    IC SUPERVISOR 1 CHANNEL TSOT23-6

  • 数据手册
  • 价格&库存
MP6400DJ-12-LF-P 数据手册
HR1200 High-Performance Digital PFC+LLC Combo Controller NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 DESCRIPTION FEATURES The HR1200 is a high-performance controller that integrates an advanced digital PFC controller and a half-bridge LLC resonant controller. It requires quite low input power at no load or ultra-light load, making it compliant with Energy using Product Directive (EuP) Lot 6 and Code of Conduct Version 5 Tier 2 specifications. General System Features The PFC of the HR1200 employs a patented average current control scheme, which can operate both in continuous conduction mode (CCM) and discontinuous conduction mode (DCM) according to the instantaneous condition of the input voltage and output load. The IC exhibits excellent efficiency and high power factor (PF) at light load. In CCM, the HR1200 can be used in applications up to 500W with minimal board size limitations. The performance of the PFC can be optimized by programming multiple parameters through an I2C GUI. Programming can be completed either by the factory or by the customer referring to a detailed user guide. The half-bridge LLC resonant converter achieves high efficiency with zero-voltage switching (ZVS). The HR1200 implements an adaptive dead-time adjustment (ADTA) function to guarantee ZVS in different load conditions. Additionally, the HR1200 can prevent the LLC converter from operating in capacitive mode, making it more robust and easier to design. The HR1200 integrates a high-voltage (HV) current source internally for start-up. When the AC input is removed, the HV current source also functions as an X-cap discharger. Such features are helpful to reduce related devices, thus reduce power consumption at no load. The HR1200 has multiple protection features including thermal shutdown (TSD), open-loop protection (OLP), over-current protection (OCP), over-voltage protection (OVP), and brownin/brown-out protection.       Meets EuP Lot 6 and COC Version 5 Tier 2 Specifications HV Current Source for Start-Up Smart X-Cap Discharger Standard I2C Interface 1k EEPROM to Store Parameters User-Friendly GUI for Digital PFC PFC Controller        High Efficiency from Light Load to Full Load by CCM/DCM Multi-Mode Control High PF Due to Patented Input Capacitor Current Compensation Programmable Frequency Jittering Programmable Brown-In and Brown-Out Programmable Soft Start Cycle-by-Cycle Current Limit Open-Loop Protection LLC Controller         600V High-Side Gate Driver with Integrated Bootstrap Diode and High dv/dt Immunity Adaptive Dead-Time Adjustment of HB LLC with Minimum and Maximum Limit Burst Mode Switching Safe Start-Up in Case of System Fault Two-Level Over-Current Protection (OCP) Latch Shutdown Protection Over-Temperature Protection (OTP) Capacitive Mode Protection APPLICATIONS      Notebook Adapters All-in-One or Gaming Power Supply Desktop PC and ATX Power General AC/DC Power Supply up to 600W LCD TV and Plasma TV Power Supply MPS parts are lead-free, halogen-free, and adhere to the RoHS directive. For MPS green status, please visit the MPS website under quality assurance. “MPS” and “The Future of Analog IC Technology” are registered trademarks of Monolithic Power Systems, Inc. Analog digital adaptive modulation (ADAM) and advanced asynchronous mode (AAM) are trademarks of Monolithic Power Systems, Inc. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 1 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 Q5 Rfmax GNDP C8 C4 SO TIMER SDA SCL R6 HV SS CSS RSS BURST FSET CT GNDS VCC HR1200 RES GNDD R5 V3.3 C3 ACIN CSP R4 V3.3 RHV Rin1 90-264VAC 47-63Hz CX1 LCM1 D1 D2 CX2 Rin2 B1 C1 Rsp LPFC Q1 R9 R8 D3 R1 R2 R3 U* CSHB CHBVS GATEP LSG SW HBVS HSG C2 Vreg BST FBP Cbst C5 Cbus + Vbus=400V D4 Rfmin CT C9 R10 Q3 Q2 Rf Cf D5 + Lr C7 D6 R7 C6 Cr T2 Q4 MP6922 Feedback Network C10 Vout- Vout+ TYPICAL APPLICATION Figure 1: Typical Application HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 2 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ORDERING INFORMATION Part Number* Package Top Marking HR1200GM−XXXX* HR1200GY−XXXX* TSSOP-28 SOIC-28 See Below *−XXXX: internal code version control. For customer-specific projects, MPS will assign a special 4-digit number. For Tape & Reel, add suffix −Z (e.g. HR1200GM−XXXX−Z) For Tape & Reel, add suffix −Z (e.g. HR1200GY−XXXX−Z) TOP MARKING MPS: MPS prefix YY: year code WW: week code HR1200: first six digits of the part number LLLLLLLLL: lot number PACKAGE REFERENCE SDA 1 28 SCL SDA 1 28 SCL ACIN 2 27 FBP ACIN 2 27 FBP RES 3 26 V3.3 RES 3 26 V3.3 CSP 4 25 SS CSP 4 25 SS GNDD 5 24 CT GNDD 5 24 CT GNDP 6 23 FSET GNDP 6 23 FSET GATEP 7 22 BURST GATEP 7 22 BURST VREG 8 21 CSHB VREG 8 21 CSHB LSG 9 20 GNDS LSG 9 20 GNDS TIMER 10 19 HBVS TIMER 10 19 HBVS SO 11 SO 11 18 NC VCC 12 17 SW HV HR1200 14 TSSOP-28 HR1200 Rev 1.1 3/25/2020 HR1200 17 SW VCC 12 16 HSG NC 13 16 HSG 15 BST HV 14 15 BST SOIC-28 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 3 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 θJA θJC Recommended Operating Conditions(1) Thermal Resistance(4) HVpk ......................................................... ≤500V Supply voltage (VCC) ......................... 14V to 30V Operating junction temp. .......... -40°C to +125°C TSSOP-28 .............................. 82 ....... 20 ... °C/W SOIC-28 ................................. 60 ....... 30 ... °C/W ABSOLUTE MAXIMUM RATINGS(2) Parameter General Total power dissipation(3) Storage temperature Junction temperature Lead temperature Voltage Voltage on HV Floating supply voltage Floating ground voltage Voltage on high-side gate driver Floating ground max. slew rate Voltage on VCC Voltage on VREG VREG Supply Current V3.3 Supply Current Voltage on low-side gate driver Voltage on PFC gate driver Voltage on CS Voltage on HBVS Other analog pins Other digital pins Analog ground to digital ground Current Current on HBVS Source current of FSET ESD(4) Symbol Ptotal Tstg TJ TLEAD VHV VBST VSW VHSG dVSW/dt VCC Vreg Ireg I3V3 VLSG VPFCG VCS VHBVS Condition Min Max Units W -55 -40 1.56 +150 +150 260 C C C -0.5 -0.5 -6.5 -0.3 -0.5 -0.5 +700 +618 +618 +618 50 +38 +14 50 20 +14 +14 +6.5 Self-limited 6.5 2 V V V V V/ns V V mA mA V V V V V V -0.3 +0.3 V -65 +65 2 mA mA Tamb = 125°C Continuous -0.5 -1 -3 -0.5 -0.5 GNDP/GNDS to GNDD IHBVS IFSET All pins Human body model 2000 V All pins Machine model 200 V All pins Charged device model 500 V NOTES: 1) The device is not guaranteed to function outside of its operating conditions. 2) Exceeding these ratings may damage the device. 3) The maximum allowable power dissipation is a function of the maximum junction temperature TJ (MAX), the junction-to-ambient thermal resistance θJA, and the ambient temperature TA. The maximum allowable continuous power dissipation at any ambient temperature is calculated by PD (MAX) = (TJ (MAX)-TA)/θJA. Exceeding the maximum allowable power dissipation produces an excessive die temperature, causing the regulator to go into thermal shutdown. Internal thermal shutdown circuitry protects the device from permanent damage. 4) Measured on JESD51-7, 4-layer PCB. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 4 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ELECTRICAL CHARACTERISTICS VCC = 25V, TJ = -40°C to 125°C, currents entering the IC are positive, min and max are guaranteed by characterization, typical is tested under 25°C, unless otherwise specified. Parameter Symbol Condition Min Typ Max Units High-Voltage Start-Up Current Source (HV) Breakdown voltage VHVBR 700 V Normal charge current IHVNOR VHV = 100V, VCC = 15V, TJ = 25°C Normal charge current IHVNOR VHV = 100V, VCC = 15V 4.5 7 8.9 mA Supply current when fault occurs IHVLimit VHV = 100V, VCC = 0V 0.8 1.4 2.1 mA Leakage current when turned off IHVoff VHV = 400V, VCC = 24V 7 10 µA 20 21.5 23.1 V 10.5 13.9 11.3 15 12.1 16.2 V V 8.4 9 9.9 V 5.5 7 8.5 mA IC Power Supply (VCC) IC turn-on threshold voltage when HV is detected UV protection threshold 1 UV protection threshold 2(5) VCCON(HV) VCCUVP1 VCCUVP2 VHV > VHVON LLC operation LLC disabled IC release threshold VCCRST Operation current at normal ICC(nor) RRES =20kΩ fPFC = 120kHz fLLC = 200kHz Start-up current ICC-start1 VCC = 20V 14 0.55 mA 0.7 mA Current at fault (LLC fault, PFC operation)(5) ICC-Disable1 TIMER = 4V PFC burst 2 mA Current at fault (LLC fault, PFC fault)(5) ICC-Disable2 TIMER = 4V 0.5 mA Vreg Ireg = 0mA Ireg = 30mA Regulated Power Supply (VREG) Regulated output voltage 11.3 10.8 12 11.8 12.8 12.6 V V IC enable threshold VregON 10.2 10.8 11.5 V UVP VregUVP 7.7 8.2 8.8 V 2.95 2.85 3.15 3.1 3.45 3.35 V V Power Supply for Digital Core (V3.3) Voltage regulation range V3V3 I3V3 = 0mA I3V3 = 15mA X-Cap Discharger (HV) X-cap discharger current(5) IX-d X-cap discharger clock time TX-d 5.5 0.9 1.5 mA 2.4 ms PFC Gate Driver Sourcing capacity(5) Igate_sr CGate = 1nF 750 mA Sinking capacity Igate_sk CGate = 1nF Gate-on resistor Ron(H) Ron(L) Voltage fall time Voltage rise time (5) HR1200 Rev 1.1 3/25/2020 -800 mA Sourcing 20mA Sinking 20mA 4.5 2.5 Ω Ω Tf CGate = 1nF 10 ns Tr CGate = 1nF 15 ns www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 5 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ELECTRICAL CHARACTERISTICS (continued) VCC = 25V, TJ = -40°C to 125°C, currents entering the IC are positive, min and max are guaranteed by characterization, typical is tested under 25°C, unless otherwise specified. Parameter Symbol Condition Min Typ Max Units 1.245 1.25 1.255 V Reference Current (RES) Voltage regulation range VRT TJ = 25°C fosc_nor At normal 19 MHz At fault or burst off 1 MHz System Clock Clock frequency fosc_nopwm AC Input Sensing (ACIN) Voltage range KACIN = 0.0032 0 1.6 V KACIN = 0.0032 0 1.6 V KACIN = 0.0032 0 1.6 V RRES = 20kΩ 61 64 µA PFC Feedback (FBP) Voltage range Current Sense (CSP) Voltage range Bias current in CSP Icsp-bias 62.5 ADC for ACIN, FB, and CSP ADC voltage reference ADC TJ = 25°C resolution(6) 1.593 1.600 1.607 V 10 bits Acquisition time(6) 350 ns Integral non-linearity (INL)(6) ±7.0 LSB Differential non-linearity (DNL)(6) ±4.5 LSB Offset error(6) ±0.5 LSB ±1.5 LSB 1.593 1.600 1.607 V 7 bits Integral non-linearity (INL)(6) ±1.5 LSB Differential non-linearity (DNL)(6) ±0.3 LSB ±0.2 LSB ±1.5 LSB 5 µs 1.593 1.600 1.607 V 10 bits ±4.5 LSB Differential non-linearity (DNL)(6) ±2.0 LSB Offset error(6) ±0.5 LSB ±1.5 LSB Gain error(6) DAC for OVP and OCL Reference voltage TJ = 25°C Resolution(6) Offset Gain error(6) error(6) Output setting time (5) DAC for Set Comparator Reference voltage TJ = 25°C Resolution(6) Integral non-linearity Gain error(6) HR1200 Rev 1.1 3/25/2020 (INL)(6) www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 6 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ELECTRICAL CHARACTERISTICS (continued) VCC = 25V, TJ = -40°C to 125°C, currents entering the IC are positive, min and max are guaranteed by characterization, typical is tested under 25°C, unless otherwise specified. Parameter Symbol Condition Min Typ Max Units 60 360 mV Comparator for Set Signal, OVP, and OCL Offset voltage I2C Characteristics (SCL/SDA)(5) Input high voltage (VIH) 2.1 V Input low voltage (VIL) Output low voltage (VOL) 2 I C Timing Characteristics 0.8 V 0.4 V 400 kHz (5) Operating frequency range 100 4.7 μs Holding time 4.0 μs Repeated start condition setup time 4.7 μs Stop condition setup time 4.0 μs Data hold time 0 ns Data setup time 250 ns Clock low time out 25 Clock low period 4.7 Clock high period 4.0 Bus free time Between stop and start 35 ms μs 50 μs Clock/Data fall time 300 ns Clock/Data rise time 1000 ns High-Side Floating Gate Driver Supply (BST, SW) BST leakage current ILKBST VBST = 600V 10 µA SW leakage current ILKSW VSW = 582V 10 µA Current Sensing of the Half-Bridge (CSHB) Frequency shift threshold VCS-OCR OCR 0.7 0.77 0.83 V OCP threshold VCS-OCP OCP 1.41 1.48 1.55 V Current polarity comparator reference when HSG is on VCSPR 80 mV Current polarity comparator reference when LSG is on VCSNR -80 mV Output Voltage Sense (SO) Latch protection on SO VSO-Latch 3.22 3.42 3.6 V Start-up failure protection on SO VSO-SFP 1.85 1.96 2.08 V Pull-up current on SO ISO-PU 100 nA Oscillator (FSET, CT) Output duty cycle HR1200 Rev 1.1 3/25/2020 D TJ = 25°C 48 50 52 % TJ = -40°C to 125°C 47 50 53 % www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 7 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ELECTRICAL CHARACTERISTICS (continued) VCC = 25V, TJ = -40°C to 125°C, currents entering the IC are positive, min and max are guaranteed by characterization, typical is tested under 25°C, unless otherwise specified. Parameter Oscillation frequency Symbol Condition Min Typ fosc Max Units 600 kHz CT peak value VCTP 3.54 3.74 3.94 V CT valley value VCTV 0.79 0.87 0.95 V Voltage reference at FSET VREF 1.88 1.97 2.06 V tDMIN Dead time CHBVS = 5pF tDMAX tD_float Timer for CMP HBVS floating 240 ns 0.82 1.1 1.38 µs 230 300 390 ns tD_CMP 50 µs Voltage clamp VHBVS-C 7.5 V Minimum voltage for the change rate to be detected dvmin/dt Half-Bridge Voltage Sensing (HBVS) Turn-on delay CHBVS = 5pF, typically 190 V/µs Td Slope finish to turn-on delay 130 ns Rd VCS > VCS-OCR 120 Ω VSS-OCP VCS > VCS-OCP Soft-Start Function (SS) Discharge resistance Threshold for OCP 1.61 1.72 1.82 V 1.18 1.23 1.28 V Standby Function (BURST) Disable threshold Vth Hysteresis Vhys 40 mV Delayed Shutdown (TIMER) Charge current ICHARGE Charge current for SFP VTIMER = 1V, VCS = 0.85V, SO = 3V 90 ICHARGE_SFP SO < 2.5V 140 180 25 µA µA Threshold for forced operation at maximum frequency Vth1 1.87 1.97 2.07 V Shutdown threshold Vth2 3.25 3.45 3.65 V Restart threshold Vth3 0.23 0.29 0.35 V Low-Side Gate Driver (LSG) Peak source current(5) Isourcepk 0.75 A Peak sink current(5) Isinkpk 0.87 A Sourcing resistor Rsource 4 Ω Rsink 2 Ω Fall time tf 20 ns Rise time tr 20 ns Sinking resistor HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 8 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 ELECTRICAL CHARACTERISTICS (continued) VCC = 25V, TJ = -40°C to 125°C, currents entering the IC are positive, min and max are guaranteed by characterization, typical is tested under 25°C, unless otherwise specified. Parameter Symbol Condition Min Typ Max Units High-Side Gate Driver (HSG, Referenced to SW) Peak source current(5) Isourcepk 0.74 A Isinkpk 0.87 A Rsource 4 Ω Rsink 2 Ω Fall time tf 20 ns Rise time tr 20 ns Thermal shutdown threshold 145 °C Thermal shutdown recovery threshold 100 °C Peak sink current (5) Sourcing resistor Sinking resistor Thermal Shutdown NOTE: 5) Guaranteed by design. 6) Guaranteed by characterization. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 9 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL CHARACTERISTICS HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 10 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL CHARACTERISTICS (continued) HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 11 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL PERFORMANCE CHARACTERISTICS VIN = 85V to 265V, VOUT = 12V, IOUT = 20A, TA = 25°C, unless otherwise noted. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 12 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL PERFORMANCE CHARACTERISTICS (continued) VIN = 85V to 265V, VOUT = 12V, IOUT = 20A, TA = 25°C, unless otherwise noted. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 13 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL PERFORMANCE CHARACTERISTICS (continued) VIN = 85V to 265V, VOUT = 12V, IOUT = 20A, TA = 25°C, unless otherwise noted. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 14 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 PIN FUNCTIONS Package Pin # Name 1 SDA I2C data bus. Connect a suitable pull-up resistor from SDA to V3.3. 2 ACIN Input voltage sensing. ACIN is connected to ADC internally. The voltage is used for on-time calculation and brown-in/brown-out protection. The ratio of the external resistor divider should be 0.0032. It is recommended to connect a 680pF capacitor from ACIN to GNDD. 3 RES Reference current for producing system clock and bias voltage on CSP. RES connects to a precise reference voltage of 1.25V internally. The reference current is produced by connecting a 20kΩ, 0.5% resistor externally from RES to GNDD. 4 CSP Sensing of the PFC inductor current. Connect a 20kΩ, 0.5% resistor to CS to produce a bias voltage of 1.25V. 5 GNDD Ground reference for the digital core of the PFC. 6 GNDP Ground reference of the PFC gate driver and the LLC low-side gate driver. 7 GATEP Gate driver output of the PFC MOSFET. 8 VREG Regulated power supply. VREG provides a regulated power supply for the PFC and LLC gate drivers or external circuits. 9 LSG Low-side gate driver of HB. The driver is capable of a minimum 0.7A sourcing current and a minimum 0.8A peak sinking current to drive the lower MOSFET of the half-bridge leg. LSG is actively tied to GND during UVLO. 10 TIMER Setting of protection and recovery time. Connect a capacitor and a resistor from TIMER to GNDS to set both over-current protection delay and recovery delay. 11 SO Latch function for OVP and OTP. If the SO voltage exceeds VSO-Latch, the IC stops switching immediately and remains latched off until VCC drops below VCCRST. When the LLC is enabled during start-up, if the SO voltage is still below VSO-SFP after the TIMER voltage reaches Vth2, the IC stops operating. Connect SO and GNDS with a noise-decoupling capacitor more than 100nF placed as close to the IC as possible. 12 VCC IC supply power. When the power is on, VCC is charged up by HVCS internally at first and then by the auxiliary power supply. 13, 18 NC Not connected. NC is not connected in SOIC28 package and removed in TSSOP28 package to increase creepage distance. 14 HV High-voltage current source for the IC start-up. HV also acts as an X-cap discharger when the input voltage drops out. 15 BST Voltage bootstrap. BST is connected externally to a capacitor to build a power supply to drive the high-side MOSFET of the HB LLC. 16 HSG High-side gate driver of HB. HSG is the gate driver output for the high-side MOSFET of the HB LLC. 17 SW Reference of the high-side gate driver and bootstrap capacitor. Description 19 HBVS Slope sensing to achieve adaptive dead-time adjustment. Detect the dv/dt of the half-bridge mid-point. A 5pF high-voltage capacitor is recommended between SW and HBVS. LLC works with fixed dead-time (about 300ns) when HBVS is floating. Connecting HBVS to GNDS disables the LLC switching. 20 GNDS Ground reference of LLC and power management circuits. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 15 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 PIN FUNCTIONS (continued) Package Pin # Name Description Current sense of half-bridge. The LLC current can be sensed by a sense resistor or a capacitive divider. CSHB has the following functions: 1. Over-current regulation: As the voltage exceeds the VCS-OCR threshold, the soft-start capacitor on SS discharges internally. The frequency increases, limiting the output power. An output short circuit results in a nearly constant peak primary current. A timer set on ACIN limits the duration of this condition. 21 CSHB 2. Over-current protection: If the current continues to build up (despite the frequency increase) when the CSHB voltage reaches VCS-OCP, CSS is discharged continuously, and OCP is not triggered immediately until VSS < VSS-OCP. If the condition for VCS > VCS-OCP remains once VSS drops below VSS-OCP, the IC shuts down. CTIMER continues to be charged by an internal 140µA current source until the TIMER voltage reaches Vth2. The IC resumes operation when the TIMER voltage falls below Vth3. 3. Capacitive mode protection: The moment LSG is turned off, the CSHB voltage level is compared with a -80mV CMP threshold. If CSHB > -80mV, it blocks the HSG gate output until the slope comes down or the CMP timer runs out. Once HSG is turned off, CSHB is compared with a +80mV CMP threshold. If CSHB < +80mV, it blocks the LSG gate output until the slope comes up or the CMP timer runs out. As soon as capacitive mode is detected, the soft-start capacitor on SS discharges internally and the frequency increases. All functions are disabled when CSHB is connected to GND. BURST Burst mode control. If the voltage on BURST is lower than Vth (1.23V), the IC is disabled and resumes when the voltage exceeds 1.23V with a hysteresis of about 40mV. During burst mode, soft-start is not activated. This function helps reduce power loss at a lighter load. 23 FSET Switching frequency set. Provide a precise and stable VREF (1.97V) reference voltage. Current flowing out of FSET regulates the LLC switching frequency and output voltage. The minimum frequency is set via a resistor connected to GND. The resistor connecting the optocoupler and FSET sets the maximum frequency. An RC series connected from FSET to GND determines the specific operating frequency. 24 CT Time set. Current flowing out of FSET is mirrored to charge and discharge the capacitor connected from CT to GNDS, which determines LLC switching frequency. 25 SS Soft-start for LLC. Connect an external capacitor from SS to GND and a resistor to FSET to set both the maximum oscillator frequency and the time constant for the frequency shift during start-up. An internal switch discharges the capacitor when the chip is turned off to guarantee soft-start (all protections are listed except CMP). 26 V3.3 A stable 3.3V voltage for digital PFC core or external circuit. A 10µF decoupling ceramic capacitor is recommended to connect V3.3 and GNDS. 27 FBP Voltage sensing of PFC output. The voltage of FBP is sampled by ADC. FBP is also used in on-time calculation, OVP, OLP, and digital PI. A 3.3MΩ pull-down resistor is connected internally. It is recommended to connect a 680pF capacitor from FBP to GNDD. 28 SCL I2C serial clock input. Connect a suitable pull-up resistor from SCL to V3.3. 22 HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 16 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 BLOCK DIAGRAM HV VCC VREG BST IHVNOR=7mA Vreg Vcc Vreg LDO Level Shifter SW Vcc Power Supply Management Slope Detection X-Cap Discharger GATEP VULO_3.3V GNDP HG HBVS Vreg LDO GNDS GNDP V3.3 LG V3.3 PWM(3.3V) LDO OCP GNDP Set/OCL CCM Off-Time/OCL V1.8V 100pF OCR VCS-OCR Ibias DAC CSP ACIN MUX PFC Control Logic LLC Control Logic ADC CSHB OCP VCS-OCP 100µA Current Direction +/-80mV FBP LLC_BO/BI (3.3V) DAC LLC_Sych (3.3V) Latch VSO-Latch SO SFP VSO-SFP OVP_PFC SS OLP_PFC EEPROM OSC RES Ifmin SS_Ctrl VREF I2C Ibias K*Ibias 1.25V FSET Pgood BURST CCO Vth SCL SDA GNDD GNDS TIMER Figure 2: Functional Block Diagram HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 17 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 FUNCTION DESCRIPTION Power Supply Management The HR1200 is a high-performance combo controller that integrates digital PFC and HB LLC controllers. This section describes how the HR1200 produces and optimizes the power supply for circuits inside the IC. Optimized power source can reduce no-load consumption and provide robust operation with sufficient fault protection. A high-voltage current source is also integrated in the IC for start-up and X-cap discharge when the AC input drops out. EEPROM The HR1200 applies EEPROM as the NVM. It has 1k bytes of data memory and 16 bytes of security memory. There are only two commands used to operate the EEPROM: 1. Read all the data from EEPROM to the memory map. This process operates automatically before the controller runs or receives a RESTORE_USER_ALL command (51h) from the I2C. 2. Write all the data from the memory map to EEPROM. This process operates when it receives a STORE_USER_ALL command (50h) from the I2C. I2C Communication and GUI The HR1200 has a standard I2C interface. It is recommended to select an I2C tool with 100kHz clock frequency. The I2C can read and write the memory map. It can also send a command to load the data from EEPROM to memory map or reload the data from memory map to EEPROM with the graphic user interface (GUI) (see Figure 3). For details, please refer to the “User Guideline_HR1200 I2C Kit and GUI” and “User Guideline_HR1200 Layout” files available on the MPS website. System Functions This section describes functions that HR1200 integrates to improve system performance, including X-cap discharge, IC on/off control, a power good signal, and an interface between the PFC stage and LLC stage for synchronous operation. Digital PFC Controller The HR1200 uses a digital PFC controller integrating digital logic, ADC, DAC, and comparators to achieve PFC functionality. To acquire programmable design parameters, I2C communication functions and EEPROM are also included. HB LLC Controller The HB LLC converter can generate an isolated and regulated output voltage from the high voltage DC bus. With an adaptive dead-time control method, the HB LLC controller helps the converter operate in ZVS in a wider load range, improving the efficiency of the converter at light load. The IC implements anti-capacitive mode operation protection, allowing for robust product design. Figure 3: HR1200 I2C GUI HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 18 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 Part 1: Power Supply Management The power supply management function is implemented via four output pins: HV, VCC, VREG, and V3.3. Figure 4 and Figure 5 show the block diagram and operation waveforms of the power management circuit. LDO VCC HV IHVLimit=1.4mA IHVNOR=7mA IHVoff=7uA X-cap discharger Bias REGULATOR Ich_max=30mA Ich_UV=5.0mA HV Start up Control Short Protection UVLO(in) If the start-up current comes from HV when VCC reaches VCCON(HV), the internal LDO is powered on. VREG begins building up, and the IC starts operating if no fault condition occurs. Then VCC is powered by the auxiliary winding of the HBC transformer. Once VCC drops below VCCUVP1, following actions occur:  The IC stops operating, and the PFC controller stops switching immediately. But the HB LLC controller continues to operate until the low-side MOSFET becomes active.  The VREG LDO is disabled. VREG CONTROL 1.2V UVLO Logic OFF/ON VCCON/VCCUVP Reset VCCRST VregON/VregUVP UVLO(in) Level shift UVLO(3.3V) Figure 4: Block Diagram of Power Supply VHV IHV 40V Vcc 1.4mA 7mA 7μA 7mA 7μA 7mA IC Supply Input (VCC) VCC provides operational power for most of the internal circuits. Then the IC can start up with the HV start-up current source. V3.3 Reset level VCCON(HV) (21.5V typically). The HV current source turns on again when VCC drops below VCCUVP1 (11.3V typically). Once the HV current source is turned off, the leakage current into HV should be below IHVoff (7µA typically). t 7μA VCCON(HV) 21.5V VCCUVP1 11.3V VCCRST 9.5V 9V The HV current source charges VCC until VCC reaches VCCON(HV), then VREG LDO is turned on again. If the IC enters latch mode, the latch status will remain until VCC falls below VCCRST. 1.2V t Vreg Vreg 11.8V 10.8V 8.2V VregON VregUVP If VCC supplied by an external DC power source instead of HV current source, please refer to the HR1201 as an alternative. t VUVLO t V3.3 t0 t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t11t12t13 t14 t15 t Figure 5: Operation Waveforms of Power Supply High-Voltage Start-Up Input (HV) A 7mA current source charges VCC internally when a voltage larger than 40V is applied to HV. If VCC is lower than 1.2V, the charge current from HV is limited to IHVLimit (1.4mA typically), to prevent excessive power loss caused by VCC short circuit during start-up. During normal operation, the voltage on VCC rises quickly after start-up, and the HV current source switches to the nominal current IHVNOR (7mA typically). IHVNOR charges the capacitor connected to VCC externally, and VCC voltage ramps up. The HV current source is switched off when VCC voltage exceeds the start-up HR1200 Rev 1.1 3/25/2020 Regulated Output (VREG) An internal LDO is added to stabilize voltage in order to:  Supply the internal PFC driver.  Supply the internal low-side driver of HB LLC.  Supply the internal high-side driver of HB LLC via a bootstrap diode.  Supply a reference voltage. The LDO is enabled only when VCC is higher than VCCON(HV). This ensures that any optional external circuitry connected to VREG does not dissipate any of the start-up current. The IC starts switching only when VREG is higher than VregON (10.8V typically). If VREG falls below VregUVP (8.2V typically), the IC and the PFC controller stop switching immediately. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 19 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 The HB LLC controller continues operating until the low-side MOSFET becomes active. V3.3 for Digital Logic V3.3 is a stabilized power supply for the internal digital logic. It is the output of an LDO with its input connected to VCC internally. The output of V3.3 is connected to a digital section with an internal bonding wire. When VCC is larger than VCCRST plus a hysteresis of about 0.5V, the V3.3 LDO is enabled. It can be disabled only when VCC is lower than VCCRST. The capacitor on V3.3 should be in the range of 4.7µF to 10µF to guarantee that V3.3 is stable. Out from the 3.3V LDO, there is another LDO with 1.8V output downstream for powering the internal digital circuits. consumption is reduced significantly. Once the AC voltage is disconnected, after a detection time window (Timer 1, 96ms typically), the IC controls the internal 7mA current source automatically to discharge energy from the Xcap to VCC within the Timer 3 period (48ms typically). The IC stops for an additional Timer 3 period to detect the AC. If no AC is re-applied during this last time period, the IC continues discharging during the Timer 2 period (144ms typically) until VHV is below 35V. Once VHV drops below 35V, VCC is discharged quickly by the internal current source, which speeds up recovery when the IC is in latch mode. AC remove VHV Detect whether input re-plug to AC line Unplug Detection The UVLO (3.3V signal) is an enable signal for both the digital PFC and LLC controller. When VCC is larger than VCCUVP1, and VREG is larger than VregON, UVLO (3.3V signal) goes high. Discharge Discharge UVLO (3.3V signal) Discharge 35V IHV Timer 1 Timer3Timer3 Timer2 t Timer3 Timer2 t Disch_en Part 2: System Functions X-Cap Discharger X-caps are critical components placed at the input terminals of the power supply to filter out differential mode EMI noise. If the AC line voltage is removed, the redundant voltage on X-caps may cause harm to the user. Safety standards require the voltage to be discharged to a safe level within a certain time frame. Commonly, resistors are placed in parallel with X-caps across the AC line to provide a discharge path. However, extra resistors bring continuous power consumption as long as the AC input is connected, which is the significant contributor to power consumption at no-load or standby conditions. The HV current source in the HR1200 acts as a smart X-cap discharger when the AC input is removed. So, traditional discharge resistors can be eliminated. Operating waveforms are shown in Figure 6. In a normal stage, the HV current source is off. The leakage current in HV is small, so power HR1200 Rev 1.1 3/25/2020 VCC VCCON VCCXCD 21.5V VCCRST t 9V Vreg t Driving Signal t t0 t'0 t1 t2 t3 t4 t5 t6 t7 t8 t9 t10 t Figure 6: Operating Waveforms of X-Cap Discharger when AC Removed If the AC recovers in HV again during the Timer 3 period, a new start-up procedure begins (see Figure 7). If the X-cap discharge function is enabled, VCC should be regulated between VCCON and VCCXCD to avoid over-stressing VCC. The X-cap discharge function is very flexible, and allows users to choose an X-cap value to optimize differential mode EMI filtering without worrying about the effect of the required bleed resistors on the standby power budget and system no-load. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 20 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 The IC can be disabled by programming the EEPROM through the I2C GUI (see Table 1). AC remove VHV Unplug Detection Table 1: IC Disabled through I2C and MPS’ GUI Discharge IHV Timer1 Timer3 t Timer3 t Disch_en VCC t VCCON VCCXCD 21.5V t Vreg t t0 t'0 t1 t t4 t5 t2 t3 Figure 7: Operating Waveform of X-Cap Discharger when AC Recovered Over-Temperature Protection (OTP) Once the internal thermal sensor senses the IC temperature is over 145°C, the IC stops switching immediately. Both the LDO for VREG and V3.3 are disabled. If the IC temperature rises above 100°C, the high-voltage current source is disabled. The IC is enabled again when VCC drops below VCCRST. If the IC temperature drops below 100°C, the IC starts up again. IC On/Off Control The IC is turned off by pulling FBP down to GND with an external MOSFET (see Figure 8). If the FB voltage is less than 0.2V, both the PFC and LLC disable the PWM switching during startup or operation. When the FBP voltage is higher than 0.3V, the IC is turned on again. Besides, the IC can be turned off from the secondary side through an optocoupler. ad_channel ACIN 2 adc_rdy 12 There are two signals between the PFC and the LLC part: 1. D2D brown-in/out signal (see Figure 9) Driving Signal ad_result PFC and LLC Interface MUX ADC A0 Filter A1 Filter A2 Filter FBP ad_clk adc_soc Vout CSP If the output voltage is higher than VD2D_BI, the D2D_BI/BO signal is set high, enabling the LLC stage. The LLC stage is disabled when the output voltage drops below VD2D_BO. This function guarantees the LLC operates within a proper input voltage range, preventing the LLC from running in capacitive mode. VD2D_BI and VD2D_BO are programmable through I2C. The register address for VD2D_BI is one word (16h, 17h). The register address for VD2D_BO is one word (18h, 19h). The value in the register can be calculated with Equation (1): 1023   DEC2HEX  VD2D_BI/BO  0.0032  1.6   (1) 2. LLC burst synchronize signal When the LLC operates in burst mode, the PFC burst mode can be synchronized with the LLC burst mode. This is achieved by setting bit 7 of register 56h high. When bit 7 is low, the LLC and PFC burst independently. Part 3: PFC Controller The state-of-the-art CCM/DCM control scheme can reduce the RMS current drawn from the AC mains by ensuring good shape of the input current both in CCM and DCM. The control scheme reduces the switching frequency when the load is reduced, therefore achieving higher efficiency and higher power factor at light load. On/Off Digital PFC Timing Figure 8: IC On/Off Control HR1200 Rev 1.1 3/25/2020 Figure 9 shows the timing of the digital PFC block. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 21 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 Vrec Vout_target VD2D_BI VD2D_BO Vout t VACIN mirrored and flows out of CSP. If CSP is also connected externally to a 20kΩ resistor, a bias voltage of 1.25V on CSP is produced, which keeps the CSP voltage positive (see Figure 11). VIN_BI VIN_BO Clock t V3.3 Iosc=K*Iref OSC t V1.8 Iref=62.5μA t 1.25V Vosc Ibias=Iref t rst CSP Enable RCSP t IL AC_BI/BO t Figure 10: Reference Current GATEP t D2D_BI/BO t0 t1 t2 t3 t4 RRES=20kΩ Rbias=20kΩ OCP t 20μs UVLO(3.3V) RES t5 t6 t Figure 9: Power Supply Sequence of Digital Controller Moreover, the reference current is mirrored to produce a system clock (see Figure 11). Iref=62.5μA 1.25V Ich=K*Iref Timing of the Power Supply Once VCC rises above VCCRST plus a hysteresis of about 0.5V, the V3.3 LDO is enabled and an internal LDO downstream produces a stable 1.8V power supply for the internal digital logic and system clocks. The rst signal is set high when both 3.3V and 1.8V are stable. When UVLO (3.3V signal) is validated, the IC enables OSC, ADC, DAC, and relative comparators. The enable signal is set high after a delay of 20µs, which indicates the digital core is ready to begin operation. Timing of the Digital Core If the enable signal is high, ADC begins sampling VACIN and VFBP. If the AC input meets the brown-in condition and no open-loop fault is found on FBP, the AC_BI/BO signal is set high. The PFC soft starts until the output reaches the target value. While the PFC output voltage ramps up above VD2D-BI, D2D_BI/BO is set high. the downstream LLC starts operating. Reference Current (RES) RES is connected internally to a precise reference voltage of 1.25V (see Figure 10). RES should be connected to a 20kΩ, 0.5% resistor externally. Reference current about 62.5µA is then generated. The current is HR1200 Rev 1.1 3/25/2020 RES Vref S Q Clock Cch2 R Cch1 RRES=20kΩ Delay Clock_Select: ‘1’: Clock=20MHz ‘0’: Clock=1MHz Figure 11: System Clock Generator The system clock switches from 20MHz to 1MHz when PWM is disabled (i.e. burst off, OVP, OCP, etc.) in order to reduce IC power consumption. Input Voltage Sensing The input voltage is rectified and attenuated by a resistor divider with a fixed ratio (0.0032) before provided to the ACIN input. Then, the ADC samples the voltage on ACIN including the instantaneous value, the peak value, and the frequency of the input voltage. The data are used for on-time calculation, AC brown-in/out protection, capacitor current compensation and X-cap discharge. Figure 12 shows the input voltage level defined for different functions. All parameters can be programmed through the I2C Kit and MPS’ GUI. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 22 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VACIN 1.6V 256   DEC2HEX  VIN_High/Low  0.0032   1 .6   VINMAX=500V Output Voltage Sensing VIN_Level1 [Reg: 4Fh] Normal operation range Similar to input voltage sensing, the output voltage is attenuated by a resistor divider before connected to FBP. Then the voltage on FBP is sampled by ADC. The results are used for on-time calculation and a series of protections. VIN_High/Low [Reg: 05h] VIN_Level2 [Reg: 50h] VIN_BI [Reg: 39h 38h] VIN_BO [Reg: 3Bh 3Ah] Figure 12: Input Voltage Level for Different Functions Input Brown-In/Brown-Out If VACIN is larger than the brown-in threshold (VIN_BI), it means the IC is ready to switch. If VACIN is less than the brown-out threshold (VIN_BO) for the length of one timer period, the IC stops switching. VIN_BI and VIN_BO are 10-bit values that are stored in the registers from 38h to 3Bh. The values can be calculated with Equation (2): 1023   DEC2HEX  VIN_BI/BO  0.0032   1 .6   (2) The brown-in and brown-out timer is set in register 3Ch (see Table 2). The internal pull down resistor of 3.3MΩ should be considered when designing the external resistors. Make the total divided ratio to 0.0032 according to Equation (4): RFBL L // 3.3M   0.0032 RFBL H  ( RFBL L // 3.3M ) Item VIN_BI_TIME VIN_BO_TIME Description Brown-in time Brown-out time Figure 13 shows the output voltage level that is defined for different functions. All parameters can be programmed through the I2C GUI. VFB 1.6V VIN_Level1, VIN_High/Low and VIN_Level2 separate the input voltage into four ranges to achieve different compensation values to improve PF at different input voltage ranges. The thresholds are 8-bit data. The value can be set according to Equation (3): HR1200 Rev 1.1 3/25/2020 VOUTMAX=500V VOUT_Highline_OVP [Reg: 48h] VOUT_Lowline_OVP [Reg: 49h] Normal operation range High/Low Line The low line is determined when the input voltage is lower than VIN_High/Low. The high line is determined when the input voltage is larger than VIN_High/Low plus a hysteresis of about 10V. The high/low-line signal sets the soft-start time and the resonant time for valley turn-on. It also regulates the output voltage at different levels to optimize the efficiency of the PFC stage. (4) Where RFBL-H is the divider resistor connected on high-side and RFBL-L is the divider resistor connect on low-side. Table 2: Brown-In/Out Timer in Register 3Ch Bit 7:4 3:0 (3) VOUT_Highline_nor VOUT_Lowline_nor VOUT_Highline_set1 VOUT_Lowline_set1 VOUT_Highline_set2 VOUT_Lowline_set2 VOUT_Highline_set3 VOUT_Lowline_set3 [Reg: 02h 01h] [Reg: 04h 03h] [Reg: 11h 0Eh] [Reg: 15h 12h] [Reg: 11h 0Fh] [Reg: 15h 13h] [Reg: 11h 10h] [Reg: 15h 14h] VOUT_FastLoop VOUT_OLP_Recovery=90V VOUT_OLP=60V Figure 13: Output Voltage Level for Different Functions Output Regulation To optimize efficiency, the output voltage can be auto-regulated according to the input voltage and output power. The output voltage is divided into two ranges by VIN_High/Low and is divided into four ranges according to the output power level, which can be programmed by registers from 06h to 0Bh. Therefore, the IC can auto-regulate eight output voltages accordingly. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 23 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 open loop is achieved by software and the value is fixed. Output Fast OVP VOUT_Highline_OVP and VOUT_Lowline_OVP are 7-bit values stored in register 48h and 49h. They are programmable through the I2C GUI (430V typically). A 7-bit DAC converts VOUT_OVP to an analog signal and compares the result with FBP voltage. If output voltage is larger than VOUT_OVP, the PFC stops switching. Once output voltage decreases to regulation voltage, the PFC resumes switching. Figure 14 shows the OVP circuit. VOUT_OVP(n) DAC Peak Current Sensing The PFC inductor current is sensed by RCSP and produces a negative voltage. A precise current source (Ibias) exits CSP and produces a positive bias voltage on Rbias (see Figure 16). The CSP voltage is calculated with Equation (5): VCSP ( t)  VCSP_Bias ( t)  VCS ( t) COMP VFBP(t) Blanking Time PWM(3.3V) VCS IL VOUT_OVP(t) Rcsp OVP_enable VCSP_Bias Rbias CSP PWM OCP OC2 OCP_disable S OC1 Ibias R OCP_disable Q Latch Figure 14: OVP Circuit A blanking time is inserted in OVP, keeping the IC immune to switching noise interference (see Figure 15). Both of TOVP_T and TOVP_R are programmable in register 60h. (5) Q OCP_trig OCP_release OCL_trig A path DAC IOCL(n) IOCL(t) OCL Digital Core SET DAC Iref_off(n) VFBP Iref_off(t) 430V 400V OVP trigger 2pF OVP recovery TOVP_T OVP_enable TOVP_R 10pF 10MΩ ACIN OVP Effective time 32kΩ 4kΩ 50pF MUX Figure 15: Output Fast OVP 10MΩ Fast Loop FBP 32kΩ In a dynamic load event, the PFC output voltage decreases due to the low bandwidth of the voltage control loop, which may cause the output voltage to fall out of the regulated range. Fast loop is activated when the output voltage is lower than VOUT_FastLoop. Then Ki and Kp of the digital PI are changed with X times the normal value, depending on the GUI setting. In this way, the output voltage of the PFC is regulated faster in the dynamic load event. B path ADC 4kΩ 50pF Figure 16: Current Sense Circuit in CSP Overall, the CSP voltage is positive (see Figure 17). The ADC samples VCSP_Bias (1.25V typically) regularly. Open Loop or IC Disable Condition If the FBP voltage is less then VOUT_OLP (60V typically), it is considered to be an open-loop or IC disable condition. The IC does not work and PWM switching is disabled during operation. The IC restarts only when the FBP voltage is larger than VOUT_OLP_Recovery (90V typically). The HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 24 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VCSP Sampling PWM VCSP_Bias 1.25V VCSP 0V VI-OCP =0V VI-OCL t IL OC1 OCP_blanking TOCP_blanking OCP_disable OC2 Q IL_max IL_limit Q OCP_release t Figure 17: Voltage Waveform in CSP Over-Current Protection (OCP) If the CSP voltage is less than zero, overcurrent protection is enabled. The PFC stops switching immediately, and OCP_trig is set high simultaneously. The digital core detects this status and disables the PWM. OCP can be released by the OCP_release signal. The OCP function is disabled by setting bit 3 of register 45h to logic low. The OCP behavior mode can be programmed by setting bit 2 to bit 0 of register 45h. It can be hiccup, latch or autorestart with a delay time. The default setting is hiccup. The delay time is set in register 46h. A programmable LEB1 (TOCP_blanking) of about 200ns is implemented to avoid error sensing due to switching noise. Figure 18: OCP Operation Waveform Over-Current Limit (OCL) The inductor current exists a cycle-by-cycle limit by setting the appropriate RCSP and VI-OCL. VI-OCL can be programmed in register 44h, and it can be converted to an analog signal by a 7-bit DAC. A programmable LEB1 (TOCL_blanking) of about 200ns is inserted to avoid switching noise if the digital core is turned on (similar to TOCP_blanking). Digital PFC Control Scheme Figure 19 shows the flowchart of the digital PFC control scheme. Digital Current Reference The digital PI compensates for the voltage loop. Its output Vcomp(n) is sent to the multiplier for current reference calculation (see Figure 20). The OCP function can avoid over-stressing when the inductor is shorted, or when the current is too large. Figure 18 shows the operating waveforms of the OCP function. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 25 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 where TS is the switching period, programmable in registers from 1Eh to 22h. Start ADC On-Time Calculation Mode Decision The HR1200 has three operation modes: continuous conduction mode (CCM), variable frequency discontinuous conduction mode (VFDCM), and constant frequency discontinuous conduction mode (CF-DCM). Sensing Ipk The peak value of the inductor current in CCM should satisfy Inequality (8): Sensing Vin, Vo Digital Voltage Loop Current Reference Iref Calculation Ipk (n)  2 Iref (n) Mode Determination The peak value of the inductor current in VFDCM should satisfy Inequality (9): CF_DCM VF_DCM CCM 2 Iref (n)  Ipk (n)  2 Iref (n)  DAC Input: Off_cur_ref(n)=0 DAC Input: Off_cur_ref(n)=0 DAC Input: Off_cur_ref(n) (8) Reduce On-Time Calculation VF_DCM Off-Time Ipk (n)  2 Iref (n)  Ts_max (10) Ts where Ts_max is the maximum switching period, programmable in registers from 23h to 27h. Valley Turn On 1. CCM Operation End IL Ipk Iref Figure 19: Flowchart of PFC Control Scheme Vin(n) Vo(n) Vo_ref(n) off_cur_ref Vin_avg(n) SET - Kp s  Ki + Vcomp(n) Vin  s Digital PI Vcomp Vin_avg 2 Iref(n) Vcomp (n) (0.5  Vin_pk (n))2 (6) On-Time Calculation The on-time can be calculated with Equation (7): HR1200 Rev 1.1 3/25/2020 n n+1 Vo_ref  Vin (n) Vo_ref  Ts (7) t t PWM ton Ts The digital current reference can be calculated with Equation (6): Ton (n)  n-1 Digital Multiplier Figure 20: Current Reference Iref (n)  Vin (n)  (9) Ts The peak value of the inductor current in CFDCM should satisfy Inequality (10): CF_DCM Off Time CCM Off Time Ts_max t Figure 21: CCM Control Signals When the converter operates in CCM, the off_cur_ref(n) is calculated and sent to DAC. The output of the DAC is an analog signal off_cur_ref(t) and is compared with VCS(t). If VCS(t) is lower than off_cur_ref(t), the signal will be set high. The PWM signal is set high accordingly (see Figure 21). The off current reference at CCM can be calculated with Equation (11): off_cur_re f(n)  2 Iref (n)  Ipk (n) www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. (11) 26 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 2. VF-DCM Operation When the converter operates in VF-DCM, the off current reference is set to zero. In this case, the set signal represents the boundary of DCM (see Figure 22). IL Iref PWM n-1 n  Ipk (n)  Ipk (n) (15) The new turn-on time can be calculated with Equation (16): Ipk SET As ton changes minimally, the peak value of inductor current can be seen as unchanged. See Equation (15): off_cur_ref t n+1 t V  Vin (n)   t on (n)  o_ref  Ts (n) Vo_ref (16) The delay time is calculated with Equation (17): ton Ts t td  2 I (n)      Ts_max t d (n)  Ts_max  Ts (n)  1  ref  Ipk (n)   Ts_new (17) Figure 22: VF-DCM Control Signals The new switching period is calculated with Equation (12): Ts_new (n)  Ipk (n) 2 Iref (n) Ts (12) Soft Start (SS) Once the AC input voltage is larger than VIN_BI, the Vin_ok signal pulls high, and the HR1200 initiates a soft-start sequence (see Figure 24). Vo_target The delay time is calculated with Equation (13):  I (n)  t d (n)  Ts_new (n)  Ts   pk  1  Ts  2 Iref (n)  Vo_start Vout (13) Vin 3. CF-DCM Operation When the converter operates in CF-DCM, the off current reference is set to zero. In this mode, the switching frequency is limited to the minimum switching frequency (see Figure 23). IL Iref PWM td' ton' T s' n-1 n ton Ts off_cur_ref t n+1 t td t Ts_max The PWM duty is modulated to achieve average current control. The new switching period is calculated with Equation (14): HR1200 Rev 1.1 3/25/2020 Tss The output voltage rises from the rectified output voltage to the target value. When softstart_flag is set high, the soft-start sequence is completed. The soft-start time can be calculated with Equation (18): Tss  ( Vo_target  Vo_start )  Figure 23: CF-DCM Control Signals 2 I (n)  Ts (n)  ref  Ts_max  Ipk (n) PWM softstart_flag Figure 24: Soft-Start Sequence Ipk SET Vin_ok (14) 2bit_num  1  slewrate Vadc_ref (18) where Vo_target is the target value of the output voltage, Vo_start is the soft-start value of the output voltage, bit_num is the ADC data bit (12 typically), Vadc_ref is the reference voltage of ADC (1.6V typically). The slew rate is different at high line and low line. The slew rate at high line is programmable www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 27 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 in register 1Ch; the slew rate at the low line is programmable in register 1Dh. Burst-Mode Operation At light load, the IC is always designed to run in burst mode for better efficiency or less no-load power consumption. Once the output load is lower than the threshold (e.g. 3% rated load), the PFC enters burst mode. The threshold can be programmed in register 2Dh for high line and register 2Fh for low line. In burst mode, the switching duty is calculated based on the 3% rated load. The output is regulated to Vo_target with a 5V hysteresis. The PFC keeps switching when the output voltage is below Vo_target-5V. The PFC stops switching when the output voltage ramps up to Vo_target. Burst-mode operation is synchronized with the LLC_sync signal. If the LLC_sync signal is high, the PFC PWM switching is turned off. Once the output voltage is lower than Vo_target-5V, the PFC is turned on again even if the LLC_sync signal is high. This status continues until the output voltage ramps up to Vo_target. When the PFC recovers from burst mode, it operates in critical conduction mode (CRM) for the first five switching cycles. Capacitor Current Compensation Traditional PFC control schemes only regulate the inductor current to match the shape of the input voltage. However, the input capacitor current is not controlled which may cause PF deterioration and undesired delay. With a larger capacitor or a higher input voltage, the PF even worsens. To improve the PF, the HR1200 implements a patented method to compensate for PF deterioration. Relevant data are stored in registers from 4Bh to 4Eh, corresponding to different input voltage levels. With this function, the PF is improved at all input voltage levels. frequency. Vin Vinpk 20V t fsw fsw_max fsw_nor fsw_min Tm(fm) t Figure 25: Frequency Jittering The parameters of fsw_max, fsw_min, and fm can be programmed by the I2C GUI for the best EMI performance. Part 4: LLC Controller Oscillator (FSET) Figure 26 shows the block diagram of the oscillator. A modulated current charges and discharges the capacitor on CT. The voltage on the capacitor swings between the peak threshold and the valley threshold to determine the oscillator frequency. The source current of FSET controls the current source IS-1 to charge the CT capacitor. Here, the current mirror ratio inside the HR1200 is 1A/A. When an oscillating cycle starts, IS-1 charges the CT capacitor until the voltage triggers the peak threshold voltage. The discharge current source IS-2 which is twice the source current of FSET is then turned on. Therefore, the CT capacitor is discharged with the source current of FSET. When the voltage on the CT capacitor drops to the valley threshold voltage, the IS-2 is turned off, and a new oscillating cycle repeats. SS VREF Frequency Jittering In order to reduce the EMI noise, the switching frequency is designed to be modulated by a triangular waveform with the frequency of fm. The switching frequency is modulated to the maximum value at the peak of the triangle and to the minimum value at its valley. Figure 25 shows the algorithm modulating the switching HR1200 Rev 1.1 3/25/2020 FSET Rfmin Rss Rfmax Is-1 Iset VCTV Css Iset S Q GNDS VCTP CT 2Iset Is-2 R www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 28 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 Figure 26: Oscillator Block Diagram When VCC reaches the turn-on threshold, VREG starts to ramp up. As soon as VREG exceeds VregON, CT begins to be charged and LSG switches on first. When CT ramps up to VCTP, LSG switches off and CT holds for a period of dead time. Once the dead time expires, CT drops down and HSG switches on. HSG keeps working until CT drops down below VCTV, HSG is turned off. A full switching cycle repeats unless VCC is lower than VCCUVP. Figure 27 shows the detailed CT waveform from start-up to steady state. fs  1 3  CT  RFSET (19) where RFSET represents the total equivalent resistor on FSET. The minimum and maximum frequency can be calculated with Equation (20) and Equation (21): 1 3  CT  Rfmin (20) 1 3  CT  (Rfmin || Rfmax ) (21) fmin  fmax  The values of Rfmin and Rfmax can be extracted: Vcc VCCON VCCUVP t Vreg VregON VregUVP CT VCTP t 1 3  CT  fmin (22) Rfmax  Rfmin fmax 1 fmin (23) ADTA VCTV t HSG t LSG Ts t Figure 27: CT Waveform from Start-Up to Steady State The RC network connected externally to FSET determines the switching frequency and the soft-start switching frequency. Rfmin connected from FSET to GND contributes to the maximum resistance of the external RC network when the phototransistor is blocked. Therefore, it sets the minimum source current from FSET, which determines the minimum switching frequency. Under normal operation, the phototransistor controls the current through Rfmax to modulate the frequency for output voltage regulation. When the phototransistor is saturated, the current through Rfmax is at its maximum, thus setting the maximum switching frequency. An RC tank connected in series between FSET and GND is used to shift the frequency during start-up (see the “Soft Start” section for details). The operation period can be expressed with Equation (19): HR1200 Rev 1.1 3/25/2020 Rfmin  Soft Start (SS) For the resonant half-bridge converter, the power delivered is inversely proportional to the switching frequency. To ensure the converter starts or restarts safely, the soft-start function sets the switching frequency at a high value until the value is controlled by the closed loop. The soft-start can be easily achieved using an external RC series circuit. At the beginning of the start-up sequence, the SS voltage is 0V. The soft-start resistor RSS is in parallel with Rfmin. So Rfmin and RSS determine the initial frequency: fstart  1 3  CT  (Rfmin || Rss ) (24) During start-up, CSS is charged until its voltage reaches the reference VREF, and the current flowing through RSS drops to zero. This period takes about 5RSSCSS. During this period, the switching frequency changes following an exponential curve. Initially, the CSS charging process decays relatively quickly, but the rate slows progressively. After this period, the output voltage is still not close to the setting value, so the feedback loop takes over after start-up. With a soft-start function, the input current increases gradually until the output voltage reaches the setting point with little overshoot. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 29 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 The parameters of the soft-start RC network can be chosen according to Equation (25) and Equation (26): the differential current elapses accordingly. HBVS starts to ramp up. LSG switches on after a minimum dead-time. Rfmin The duration from the time HSG switches off to the time LSG switches on is defined as the dead time. It relies on the completion of SW’s transition. R ss  Css  fstart 1 fmin 3  10-3 Rss (25) (26) Select the initial frequency fstart at least four times the minimum value fmin. When selecting CSS, there is a trade-off between the desired soft-start operation and the OCP speed. Adaptive Dead-Time Adjustment (HBVS) The dead-time period between HSG and LSG drivers is always needed in half-bridge topologies in order to prevent any crossconduction through the power stage MOSFETs, which may result in excessive current, high EMI noise and destructions in practical applications. Traditional fixed dead-time control scheme is often used in resonant converters as it is simple to implement. However, this method can cause hard switching in light load or large Lm design condition which eventually leads to thermal and reliability issues. The HR1200 incorporates an intelligent ADTA logic circuit, which is capable of detecting the dv/dt of SW and automatically inserting a proper dead-time with respect to the actual operating conditions of the converter. To achieve this, a 5pF high-voltage capacitor is recommended between SW and HBVS. With ADTA, the MOSFET body diode conduction time can be minimized which enables the LLC converter to achieve high efficiency from light load to full load due to ZVS. Moreover, the design of thermal management and Lm of the transformer can be easier. Figure 28 shows the simplified block diagram of ADTA. When LSG switches off, SW swings from zero to high, creating a positive differential current via CHBVS. The dead time adjusts automatically to current information. To avoid damaging HBVS, the differential current should not be higher than 65mA. Otherwise, a smaller value for CHBVS must be selected to meet Inequality (27): id  CHBVS  dV  65mA dt (27) However, if the value for CHBVS is too small to detect dv/dt, the minimum voltage change rate dvmin/dt is taken into account to choose an appropriate CHBVS. First, calculate the peak magnetizing current Im according to Equation (28): Im  Vin 8  Lm  fmax (28) Then CHBVS can be designed: CHBVS  950 μA Coss  Im 2 (29) where Coss is the output capacitance of the power stage MOSFET when Vds equals zero. For a typical design, Lm=870µH, Vin=450Vdc, and fmax=140kHz. Based on calculation results, CHBVS should be larger than 4.5pF. So 5pF is selected, typically fit for most MOSFETs. Once HSG switches off, SW begins swinging from a high voltage to a low voltage due to the resonant tank current Ir. A negative dv/dt draws a current from HBVS via CHBVS. HBVS is pulled down depending on dv/dt and CHBVS. If the differential current is higher than the internal comparator current, HBVS will be pulled down to zero and clamped. When SW stops slewing, HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 30 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 Vbus HSG Driver HG HSG CBOOT SW Lr LG ADTA Logic LG CLK tDMAX t t Vgate LSG CHBVS LSG HSG LSG HSG t VSW Cr GNDP HG tDMIN VCLK Vreg LSG Driver tDMIN Vosc BST id HBVS t VDT CLKN t0 t1 t2 t3 t4 t5 t6 t t7 Figure 28: Block Diagram of ADTA Figure 30: Dead Time in ADTA Figure 29 shows the operation waveform of ADTA. Figure 30 illustrates the possible dead time with ADTA logic. There are three kinds of possible dead time: minimum dead time tDMIN (240ns typically), maximum dead time tDMAX (1.1µs typically), and adjusted dead time (between tDMIN and tDMAX). When the transition time of SW is smaller than tDMIN, the logic prevents the gate from providing output until tDMIN is reached. This can avoid any shootthrough of the high-side and low-side MOSFET. If the dead time is too long, it may lead to duty cycle loss and loss of soft switching. So a maximum dead time tDMAX is set forcing the gate to switch on. If HBVS is shorted to GND, LLC stops switching. If HBVS is floating, the internal circuit cannot detect the differential current in HBVS, and the fixed dead time (300ns) takes effect. Capacitive Mode Protection (CMP, CSHB) In fault conditions such as over-load or shortcircuit condition, the converter may run into the capacitive region. In capacitive mode, the voltage applied to the resonant tank is lagging off the current. The body diode of one of the MOSFETs switches on. So, to avoid device damage, the switching of the other MOSFET should be blocked. The functional block diagram of CMP is shown in Figure 31. Vbus BST Dead time adaptively adjusted HSG Driver VREF LSG HSG HSG HG FSET Iset t LSG Driver LG Discharge: SW Lr LSG OCR/OCP, CMP, Restart GNDP t Q VSW Capacitive Detected Maximum Frequency 140μA TIMER t Shut Down Vth2 Q CMP Control Logic SET D Cr -80mV CLK CLR CSHB Q Vth1 Protection Timer VHBVS CBOOT VREG SS im HSG Q SET CLR D 80mV CLK OCR VCS-OCR Restart Vth3 OCP VCS-OCP tDMIN Figure 31: CMP and OCP Block Diagram t IHBVS id t CLK Figure 32 shows the operating principle of capacitive mode protection. CSPOS and CSNEG stand for the current polarity, which is generated by comparing the voltage of CS with internal +80mV and -80mV voltage reference. t Figure 29: Operation Waveform of ADTA HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 31 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 tDMIN Vosc Timer out tDMIN tDMAX t VCLK t Vgate LSG HSG LSG VSW HSG HSG t Slope Missing t VCSHB 80mV -80mV t CSNEG t CSPOS 50μs t0 t1 t2 t3 t4 t5 The HR1200 provides two levels of over-current protection (see Figure 33). 1. Over-Current Regulation t The first level of protection occurs when the voltage on CSHB exceeds VCS-OCR (0.77V). Following actions will take place: t Figure 32: Operating Principle of CMP At t0, the low-side gate driver switches off for the first time. CSNEG is high, which means the current is at the right polarity, so the converter is operating in inductive mode. The capacitive mode protection circuit is not active. At t1, the high-side gate driver switches off for the first time. CSPOS is high, so the current is at the right polarity, and the converter operates in inductive mode. The capacitive mode protection circuit is still not active. At t2, the low-side gate driver turns off for a second time. CSNEG is zero and CSPOS is high, which means the converter is operating in capacitive mode. The body diode of the lowside MOSFET takes over the current after the low-side MOSFET is turned off. SW does not turn high, so HBVS cannot catch the dv/dt until the current returns to the correct polarity. The dead time remains high, and VCO is held. Another MOSFET does not switch on. So, capacitive switching is effectively avoided. At t3, the current returns to the correct polarity, then another MOSFET is turned on due to dv/dt being captured. If the correct current polarity cannot be detected from t2 to t4, or the current is very small and is not capable of pulling SW up or down, eventually another MOSFET will be forced to switch on when the timer for CMP (50µs) expires (as shown in Figure 32 in dashed lines). The VSS control signal controls the soft start. When capacitive mode operation is detected, HR1200 Rev 1.1 3/25/2020 Over-Current Regulation and Over-Current Protection (CSHB, TIMER) t Vss VDT VSS is high. An internal MOSFET is turned on to pull the voltage of CSS low. Therefore, the switching frequency increases quickly to limit the power delivered to the output. VSS is reset when the first gate driver is turned off (after CMP). The switching frequency decreases smoothly until the control loop takes over. a. The transistor connected internally between SS and GND is turned on for at least 10µs, which causes the CSS voltage dropping down, resulting in a sharp increase in the oscillator frequency. Hence, the energy transferred to the output is reduced. b. An internal 140µA current source is turned on to charge CTIMER and raises the voltage of TIMER pin. If the CSHB voltage drops below VCS-OCR (10mV hysteresis) before the TIMER voltage reaches Vth1 (1.97V), the discharging of CSS and the charging of CTIMER stop. Then the converter resumes normal operation. tOC represents the time for the CTIMER voltage to rise from 0V to Vth1. It is actually a delay time for over-current regulation. There is no simple relationship between tOC and CTIMER. CTIMER is selected based on experimental results. If the CSHB voltage remains larger than VCS-OCR after the TIMER voltage reaches Vth1, CSS is discharged completely. Simultaneously, internal 140µA current source continues charging CTIMER until the TIMER voltage reaches Vth2 (3.45V). At this time, the IC turns off all gate driver outputs. The period for the TIMER voltage to rise from Vth1 to Vth2 can be calculated approximately by using Equation (30): t OP  10 4  CTIMER (30) The above status remains until VTIMER drops to Vth3 (0.29V) as CTIMER is slowly discharged by www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 32 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 RTIMER. The IC then restarts. The time period can be calculated using Equation (31): t OFF  ln Vth2  RTIMERCTIMER  2.5  RTIMERCTIMER Vth3 (31) The OCR limits the energy transferred from the primary to the secondary winding during overload or short-circuit period. However, excessive power consumption due to high continuous currents can damage the secondary-side windings and rectifiers. By incorporating the TIMER function, the IC provides additional protection to reduce the average power consumption. When OCR is triggered, the converter enters a hiccup-like protection mode that operates intermittently. Figure 33 shows the timing procedure. VCC tOC tOFF tOP The HR1200 uses two methods for sensing current: lossless current sensing and sense resistor current sensing. Generally, lossless current sensing is used in high-power applications (see Figure 34). Lr R1 CSHB C1 RS CS Cr Figure 34: Current Sensing with Lossless Network tSS t VSS VREF VSS-OCP To design a lossless current sensing network, Inequality (32) should be satisfied: t ICr CS  t Cr 100 (32) VCS-OCP VCS-OCR VCS t TIMER Vth2 Vth1 Vth3 t Vout Normal Operation t Over Load Pmin Shutdown Soft Start OCP( restart mode) Figure 33: OCR Timing Sequence RS should meet Inequality (33):  C   1  r  (33)  CS  where ICrpk is the peak current of the resonant tank at low input voltage and full load. ICrpk can be expressed in Equation (34): RS  2. Over-Current Protection The second level of protection triggers when VCS > VCS-OCP (1.48V). Normally, this condition occurs when the CSHB voltage continues rising during short–circuit period. Once VCS rises to VCS-OCP, the IC does not stop switching immediately until VSS < VSS-OCP, and CSS is discharged by an internal transistor continuously. If VCS remains above VCS-OCP until VSS drops below VSS-OCP, the IC shuts down. CTIMER is charged by an internal 140µA current source until the TIMER voltage reaches Vth2. The IC resumes operation if the TIMER voltage falls below Vth3. The OCP provides a high-speed over-current limitation. The IC works in auto-recovery mode when OCP triggers. Current Sensing HR1200 Rev 1.1 3/25/2020 VCS-OCR ICrpk 2 ICrpk  NVo   Ioπ         4L m fs   2N  2 (34) where N is the turn ratio of the transformer, lo and Vo are the output current and voltage respectively, fs is the switching frequency, and Lm is the magnetizing inductance. For capacitive mode detection in no load or tiny load condition, RS should meet Inequality (35) as well: RS  80 mV  C   1  r  Im  CS  (35) In some conditions especially when large Lm is used, it’s difficult to meet Inequality (33) and Inequality (35) simultaneously. The system will operate without CMP function at light load if Inequality (35) is not satisfied. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 33 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 The R1 and C1 network is used to attenuate the switching noise on CSHB. The time constant should be no larger than 100ns. An alternative solution is to use a sense resistor in series with the resonant tank (see Figure 35). This method is quite simple, but may cause undesired power consumption on the sense resistor. SS CT CT VCO Css Iset Rss VREF FSET BURST Burst control Vth Rfmax Rfmin RBURST CBURST Lr Figure 36: Burst-Mode Operation Set-Up CSHB R1 C1 Cr RS Figure 35: Current Sensing with A Sense Resistor The sense resistor can be designed using Inequality (36): RS  VCS-OCR ICrpk (36) LLC Brown-In/Brown-Out (D2D_BI/BO) The LLC controller stops when the D2D_BI/BO signal is low and recovers once the D2D_BI/BO signal goes high. Burst-Mode Operation (BURST) Under light-load or no-load condition, the resonant half-bridge switching frequency is limited by the system maximum frequency. To control the output voltage and limit the power consumption, the HR1200 enables the converter to operate in burst mode to reduce the average switching frequency, thus reducing the average residual magnetizing current and related power losses. HR1200 Rev 1.1 3/25/2020 Figure 36 shows a typical circuit connecting BURST to the feedback signal. RBURST and CBURST must be optimized to adjust the number of switching cycles during burst-on period, which can reduce no-load power consumption. Rfmax can determine the maximum switching frequency which is needed for the IC to operate in burst mode. It also determines the level of output load needed to run into burst mode. Figure 37 illustrates the burst-mode operation waveforms. When the output load decreases, the BURST voltage also decreases. If the BURST voltage drops below Vth (1.23V), the HR1200 stops switching both the HSG and LSG and connects CT to GNDS internally. Meanwhile, the SYN signal is set high. It is used to synchronize the burst of PFC and LLC. Once the voltage on BURST exceeds Vth by a hysteresis of 40mV, the HR1200 resumes normal operation and the SYN signal is set low. During burst-mode operation, VREG normally holds above VregUVP, and the soft-start function is not activated. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 34 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VO t LG/HG t BURST Connect SO to the resistor divider from V3.3 if the SO functions are not needed. 1.27V 40mV 1.23V Vth+Vhys Vth with the TIMER capacitor, the TIMER voltage is pulled down gradually. Until the TIMER voltage falls below Vth3, the IC attempts another restart sequence. t High-Side Gate Driver (HSG) FBP t GATEP t SYN For PFC Burst off Burst off Burst off t Figure 37: Burst-Mode Operation Latch Protection (SO) If the SO voltage exceeds the threshold VSO-Latch (3.42V), the IC latches off. This status can only be released when VCC drops below VCCRST. This function can be used for OVP or OTP. The external BST capacitor provides energy to the high-side gate driver. An integrated bootstrap diode charges this capacitor through VCC. This diode simplifies the external driving circuit for the high-side switch, allowing the BST capacitor to be charged when the low-side MOSFET is on. Considering the BST capacitor charging time, in order to provide enough gate driver energy, a BST capacitor of 100nF to 1μF is recommender (see Figure 39). VCC Start-Up Failure Protection (SFP, SO) BST The HR1200 provides a one-shot start-up failure protection by sampling the SO voltage. Figure 38 shows the detailed SFP timing. VSO Transient Unplug from main input High Side Driver Over Load or Short 1.96V VSO-SFP t LG/HG Level Shifter HSG CBST SW t VSS Soft Start t TIMER Vth2 Vth1 3.45V 1.97V Vth3 0.29V Low-Side Gate Driver (LSG) t SFP t Figure 38: SFP Timing During start-up, the TIMER capacitor begins to be charged up by an internal 25µA current source. If the SO voltage is less than VSO-SFP (1.96V) when the TIMER voltage rises up to Vth1, then the IC treats it as a fault condition. The HR1200 begins discharging the SS capacitor, and TIMER continues ramping up irreversibly. As soon as the TIMER voltage reaches Vth2, the HR1200 stops charging TIMER, both PFC and LLC stop switching. As a resistor is in parallel HR1200 Rev 1.1 3/25/2020 Figure 39: High-Side Gate Driver LSG provides the gate driver signal for the lowside MOSFET. The maximum absolute rating table shows the maximum LSG voltage is 14V. Under certain conditions (e.g. surge rating is too high), a large voltage spike may occur on LSG due to oscillations from the long gatedriver wire, the MOSFET parasitic capacitance, and the small gate-driver resistor. The voltage spike may cause damage to LSG. Although there is suppression internally in the chip, it is better to add a 13V Zener diode close to LSG and GND to prevent damage to the chip pins (see Figure 40). www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 35 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 SW Vreg Cgd Low Side Driver LSG Cds Rg 13V Cgs GNDP Figure 40: Low-Side Gate Driver HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 36 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 PROTECTION SUMMARY Pin Description Affected Action VCC Symbol VCC_UVP Under-voltage protection for VCC System Disable VCC VCC_SCP Short-circuit protection for VCC System Disable and limit IHV VREG Vreg_UVP Under-voltage protection for VREG System Disable and limit Ich (Vreg) SO VSO_Latch Latch protection System Shutdown and latch SO VSO_SFP Start-up failure protection System Restart with timer out OTP Over-temperature protection System Disable ACIN Brown-out Line input under-voltage protection System CSP OCP_PFC Current limit of PFC PFC FBP FBP FBP OVP_PFC OLP_PFC UVP_PFC Over voltage of PFC Open-loop protection Under-voltage protection for PFC out PFC System HBC Suspend switching Program with restart or latch off Suspend switching Restart with recovery Suspend switching LLC brown-in/-out LLC stage under-voltage protection HBC Suspend switching CSHB OCR_HBC Over-current regulation of HBC HBC CSHB OCP_HBC Over-current protection HBC HBC CSHB CMR Capacitive mode regulation HBC CSHB ADT Adaptive dead time HBC Restart with timer out Shutdown, restart with timer out Increasing switching frequency Prevent hard switching HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 37 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TYPICAL APPLICATION CIRCUIT Figure 41: Application Circuit HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 38 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 PACKAGE OUTLINE DRAWING FOR 28-TSSOP PACKAGE INFORMATION MF-PO-D-0024 revision 1.0 TSSOP-28 9.60 9.80 0.40 TYP 28 15 1.60 TYP 4.30 4.50 PIN 1 ID 0.65 BSC 5.80 TYP 6.20 6.60 14 1 TOP VIEW RECOMMENDED LAND PATTERN 0.80 1.05 1.20 MAX SEATING PLANE 0.19 0.30 0.65 BSC 0.05 0.15 0.09 0.20 SEE DETAIL "A" FRONT VIEW SIDE VIEW NOTE: GAUGE PLANE 0.25 BSC 0o-8o 0.45 0.75 DETAIL “A” HR1200 Rev 1.1 3/25/2020 1) ALL DIMENSIONS ARE IN MILLIMETERS. 2) PACKAGE LENGTH DOES NOT INCLUDE MOLD FLASH, PROTRUSION OR GATE BURR. 3) PACKAGE WIDTH DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSION. 4) LEAD COPLANARITY (BOTTOM OF LEADS AFTER FORMING) SHALL BE 0.10 MILLIMETERS MAX. 5) DRAWING CONFORMS TO JEDEC MO-153, VARIATION AE. 6) DRAWING IS NOT TO SCALE. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 39 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER PACKAGE OUTLINE DRAWING FOR 28-SOIC NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 MF-PO-D-0022 revision 2.0 PACKAGE INFORMATION (continued) SOIC-28 0.024 (0.61) 0.697(17.70) 0.713(18.10) 28 15 0.050 (1.27) 0.079 (2.00) 0.291 (7.40) 0.299 (7.60) 0.394 (10.00) 0.418 (10.60) 0.370 (9.40) PIN 1 ID 14 1 TOP VIEW 0.013(0.33) 0.020(0.51) RECOMMENDED LAND PATTERN 0.050(1.27) BSC 0.093(2.35) 0.104(2.65) SEATING PLANE 0.004(0.10) 0.012(0.30) FRONT VIEW 0.010(0.25) x 45o 0.030(0.75) GAUGE PLANE 0.010(0.25) BSC 0o-8o 0.016(0.41) 0.050(1.27) DETAIL "A" HR1200 Rev 1.1 3/25/2020 0.009(0.23) 0.013(0.33) SEE DETAIL "A" SIDE VIEW NOTE: 1) CONTROL DIMENSION IS IN INCHES. DIMENSION IN BRACKET IS IN MILLIMETERS. 2) PACKAGE LENGTH DOES NOT INCLUDE MOLD FLASH, PROTRUSIONS OR GATE BURRS. 3) PACKAGE WIDTH DOES NOT INCLUDE INTERLEAD FLASH OR PROTRUSIONS. 4) LEAD COPLANARITY (BOTTOM OF LEADS AFTER FORMING) SHALL BE 0.10 MILLIMETERS MAX. 5) DRAWING CONFORMS TO JEDEC MS-013, VARIATION AE. 6) DRAWING IS NOT TO SCALE. www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 40 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 APPENDIX A: I2C COMMANDS AND REGISTERS VOUT_CMD_H (02/01h, 10bits) Set the normal value of the output voltage target at high line. The default setting for the -0001 version is 1100011110. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r VOUT_CMD_H 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VOUT_CMD_L (04/03h, 10bits) Set the normal value of the output voltage target at low line. The default setting for the -0001 version is 1100011110. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r/w VOUT_CMD_L 8 7 6 r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VIN_HL_LINE (05h, 8bits) Set the threshold of high line and low line. The default setting for the -0001 version is 01110001. Command Bit Access 7 r/w 6 r/w VIN_HL_LINE 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w AUTO_VOUT_VCOMP1 (07/06h, 14bits) Set the Load Level1 of the auto-output voltage. The default setting for the -0001 version is 011111111100. Command Bit Access 15 r 14 r 13 r/w 12 r/w 11 r/w 10 r/w AUTO_VOUT_VCOMP1 9 8 7 6 5 r/w r/w r/w r/w r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w AUTO_VOUT_VCOMP2 (09/08h, 14bits) Set the Load Level2 of the auto-output voltage. The default setting for the -0001 version is 001100110010. Command Bit Access 15 r 14 r 13 r/w 12 r/w 11 r/w 10 r/w AUTO_VOUT_VCOMP2 9 8 7 6 5 r/w r/w r/w r/w r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w AUTO_VOUT_VCOMP3 (0B/0Ah, 14bits) Set the Load Level3 of the auto-output voltage. The default setting for the -0001 version is 000110011001. Command Bit Access 15 r 14 r 13 r/w 12 r/w 11 r/w 10 r/w AUTO_VOUT_VCOMP3 9 8 7 6 5 r/w r/w r/w r/w r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w AUTO_VOUT_CMPHYS (0D/0Ch, 14bits) Set the load hysteresis of the auto-output voltage. The default setting for the -0001 version is 000011110101. Command Bit Access HR1200 Rev 1.1 3/25/2020 15 r 14 r 13 r/w 12 r/w 11 r/w 10 r/w AUTO_VOUT_CMPHYS 9 8 7 6 5 r/w r/w r/w r/w r/w 4 r/w 3 r/w 2 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 1 r/w 0 r/w 41 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 AUTO_VOUTH_CMD1_L (0Eh, 8bits) Set the low byte of the output voltage level one at high line. The default setting for the -0001 version is 00011110. Command Bit Access 7 r/w 6 r/w AUTO_VOUTH_CMD1_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTH_CMD2_L (0Fh, 8bits) Set the low byte of the output voltage level two at high line. The default setting for the -0001 version is 00011110. Command Bit Access 7 r/w 6 r/w AUTO_VOUTH_CMD2_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTH_CMD3_L (10h, 8bits) Set the low byte of the output voltage level three at high line. The default setting for the -0001 version is 00011110. Command Bit Access 7 r/w 6 r/w AUTO_VOUTH_CMD3_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTH_CMD_H (11h, 6bits) Set the high byte of the output voltage at high line. The default setting for the -0001 version is 111111. Bit 5:4 3:2 1:0 Item AUTO_VOUTH_CMD3_H AUTO_VOUTH_CMD2_H AUTO_VOUTH_CMD1_H Command Bit Access Description High bits of output voltage level three at high line. High bits of output voltage level two at high line. High bits of output voltage level one at high line. 7 r 6 r AUTO_VOUTH_CMD_H 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTL_CMD1_L (12h, 8bits) Set the low byte of the output voltage level one at low line. The default setting for the -0001 version is 00011110. Command Bit Access 7 r/w 6 r/w AUTO_VOUTL_CMD1_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTL_CMD2_L (13h, 8bits) Set the low byte of the output voltage level two at low line. The default setting for the -0001 version is 00011110. Command Bit Access 7 r/w 6 r/w AUTO_VOUTL_CMD2_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w AUTO_VOUTL_CMD3_L (14h, 8bits) Set the low byte of the output voltage level three at low line. The default setting for the -0001 version is 00011110. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w AUTO_VOUTL_CMD3_L 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 42 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 AUTO_VOUTL_CMD_H (15h, 6bits) Set the high byte of the output voltage at low line. The default setting for the -0001 version is 111111. Bit 5:4 3:2 1:0 Item AUTO_VOUTL_CMD3_H AUTO_VOUTL_CMD2_H AUTO_VOUTL_CMD1_H Command Bit Access Description High bits of output voltage level three at low line. High bits of output voltage level two at low line. High bits of output voltage level one at low line. 7 r AUTO_VOUTL_CMD_H 6 5 4 3 2 1 r r/w r/w r/w r/w r/w 0 r/w LLC_ENABLE_HIGH (17/16h, 10bits) Set the enable threshold voltage of the LLC. The default setting for the -0001 version is 1100101010. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r LLC_ENABLE_HIGH 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w LLC_ENABLE_LOW (19/18h, 10bits) Set the disable threshold voltage of the LLC. The default setting for the -0001 version is 1001010001. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r LLC_ENABLE_LOW 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w ZCD_PERIOD_H (1Ah, 7bits) Set the oscillation period of the turn-off current at high line. The default setting for the -0001 version is 0010100. Command Bit Access 7 r 6 r/w ZCD_PERIOD_H 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w ZCD_PERIOD_L (1Bh, 7bits) Set the oscillation period of the turn-off current at low line. The default setting for the -0001 version is 0101000. Command Bit Access 7 r 6 r/w ZCD_PERIOD_L 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w SLEWRATE_HIGH (1Ch, 8bits) Set the soft-start slew rate at high line. The default setting for -0001 version is 00000110. Command Bit Access 7 r/w 6 r/w SLEWRATE_HIGH 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w SLEWRATE_LOW (1Dh, 8bits) Set the soft-start slew rate at low line. The default setting for the -0001 version is 00001101. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w SLEWRATE_LOW 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 43 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TS1_L (1Eh, 8bits) Set the low byte of the switching period at level one of the input voltage. The default setting for the -0001 version is 11001000. Command Bit Access 7 r/w 6 r/w 5 r/w TS1_L 4 3 r/w r/w 2 r/w 1 r/w 0 r/w TS2_L (1Fh, 8bits) Set the low byte of the switching period at level two of the input voltage. The default setting for the -0001 version is 11001000. Command Bit Access 7 r/w 6 r/w 5 r/w TS2_L 4 3 r/w r/w 2 r/w 1 r/w 0 r/w TS3_L (20h, 8bits) Set the low byte of the switching period at level three of the input voltage. The default setting for the -0001 version is 11001000. Command Bit Access 7 r/w 6 r/w 5 r/w TS3_L 4 3 r/w r/w 2 r/w 1 r/w 0 r/w TS4_L (21h, 8bits) Set the low byte of the switching period at level four of the input voltage. The default setting for the -0001 version is 10100111. Command Bit Access 7 r/w 6 r/w 5 r/w TS4_L 4 3 r/w r/w 2 r/w 1 r/w 0 r/w TS_H (22h, 4bits) Set the high byte of the switching period. The default setting for the -0001 version is 0000. Bit 3 2 1 0 Item TS4_H TS3_H TS2_H TS1_H Description High bit of switching period at level four of the input voltage. High bit of switching period at level three of the input voltage. High bit of switching period at level two of the input voltage. High bit of switching period at level one of the input voltage. Command Bit Access 7 r 6 r 5 r TS_H 4 3 r r/w 2 r/w 1 r/w 0 r/w TS_MIN1_L (23h, 8bits) Set the low byte of the maximum switching period at level one of the input voltage. The default setting for the -0001 version is 00100000. Command Bit Access 7 r/w 6 r/w 5 r/w TS_MIN1_L 4 3 2 r/w r/w r/w 1 r/w 0 r/w TS_MIN2_L (24h, 8bits) Set the low byte of the maximum switching period at level two of the input voltage. The default setting for the -0001 version is 00100000. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w 5 r/w TS_MIN2_L 4 3 2 r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 44 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 TS_MIN3_L (25h, 8bits) Set the low byte of the maximum switching period at level three of the input voltage. The default setting for the -0001 version is 00100000. Command Bit Access 7 r/w 6 r/w 5 r/w TS_MIN3_L 4 3 2 r/w r/w r/w 1 r/w 0 r/w TS_MIN4_L (26h, 8bits) Set the low byte of the maximum switching period at level four of the input voltage. The default setting for the -0001 version is 11110100. Command Bit Access 7 r/w 6 r/w 5 r/w TS_MIN4_L 4 3 2 r/w r/w r/w 1 r/w 0 r/w TS_MIN_H (27h, 8bits) Set the high byte of the maximum switching period. The default setting for the -0001 version is 01111111. Bit 7:6 5:4 3:2 1:0 Item TS_MIM4_H TS_MIN3_H TS_MIN2_H TS_MIN1_H Description High bit of the maximum switching period at level four. High bit of the maximum switching period at level three. High bit of the maximum switching period at level two. High bit of the maximum switching period at level one. Command Bit Access 7 r/w 6 r/w 5 r/w TS_MIN_H 4 3 2 r/w r/w r/w 1 r/w 0 r/w JITTER_AMPLITUDE (28h, 8bits) Set the peak-to-peak amplitude of the switching frequency jitter. The default setting for the -0001 version is 00000010. Command Bit Access 7 r/w 6 r/w JITTER_AMPLITUDE 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w JITTER_FS (30/29h, 13bits) Set the step value and the period of step of the switching frequency jitter. The default setting for -0001 version is 0100000011110. Bit 12:11 10:0 Command Bit Access Item JITTER_STEP STEP_PERIOD 15 r 14 r 13 r Description Step value. Step period. 12 r/w 11 r/w 10 r/w 9 r/w JITTER_FS 8 7 6 r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w TON_MIN (2Bh, 5bits) Set the minimum turn-on time. The default setting for the -0001 version is 01100. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r 6 r 5 r TON_MIN 4 3 2 r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 45 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 MIN_OFF_TIME (2Ch, 5bits) Set the minimum turn-off time. The default setting for the -0001 version is 01100. Command Bit Access 7 r 6 r MIN_OFF_TIME 5 4 3 2 r r/w r/w r/w 1 r/w 0 r/w BURST_POINT_H (2E/2Dh, 13bits) Set the PFC burst load at high line. The default setting for the -0001 version is 0000111101011. Command Bit Access 15 r 14 r 13 r 12 r/w 11 r/w 10 r/w BURST_POINT_H 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w BURST_POINT_L (30/2Fh, 13bits) Set the PFC burst load at low line. The default setting for the -0001 version is 0000111101011. Command Bit Access 15 r 14 r 13 r 12 r/w 11 r/w 10 r/w BURST_POINT_L 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w NORMAL_KI (31h, 8bits) Set the Ki value at normal operation mode. The default setting for the -0001 version is 00010010. Command Bit Access 7 r/w 6 r/w NORMAL_KI 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w NORMAL_KP (32h, 8bits) Set the Kp value at normal operation mode. The default setting for the -0001 version is 01111000. Command Bit Access 7 r/w 6 r/w NORMAL_KP 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w FAST_KI (34/33h, 10bits) Set the Ki value at fast-loop operation mode. The default setting for the -0001 version is 0001001000. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r/w FAST_KI 8 7 r/w r/w 6 r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w FAST_KP (36/35h, 10bits) Set the Kp value at fast-loop operation mode. The default setting for the -0001 version is 0100100000. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r/w FAST_KP 8 7 r/w r/w 6 r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w FASTLOOP_VOLTAGE (37h, 7bits) Set the fast-loop level below the output voltage target. The default setting for the -0001 version is 0011111. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r 6 r/w FASTLOOP_VOLTAGE 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 46 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VIN_BI_LEVEL (39/38h, 10bits) Set the brown-in voltage of the input voltage. The default setting for the -0001 version is 0011101101. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r VIN_BI_LEVEL 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VIN_BO_LEVEL (3B/3Ah, 10bits) Set the brown-out voltage of the input voltage. The default setting for the -0001 version is 0011011001. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r VIN_BO_LEVEL 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VIN_BIBO_TIME (3Ch, 8bits) Set the brown-in and brown-out time of the input voltage. The default setting for the -0001 version is 00000101. Bit 7:4 3:0 Item VIN_BI_TIME VIN_BO_TIME Description Brown-in time. Brown-out time. Command Bit Access 7 r/w 6 r/w VIN_BIBO_TIME 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w IREF_LEVEL1 (3E/3Dh, 9bits) Level one of the input current reference. The default setting for the -0001 version is 010001001. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r IREF_LEVEL1 8 7 6 r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w IREF_LEVEL2 (40/3Fh, 9bits) Level two of the input current reference. The default setting for the -0001 version is 001000101. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r IREF_LEVEL2 9 8 7 6 r r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w IREF_HYS (41h, 8bits) Set the hysteresis of the level of the input current reference. The default setting for the -0001 version is 00010111. Command Bit Access 7 r/w 6 r/w 5 r/w IREF_HYS 4 3 2 r/w r/w r/w 1 r/w 0 r/w VIN_BO_TRIM1 (42h, 6bits) Set the trim value of the brown-out level of the input voltage at level one. The default setting for the -0001 version is 000000. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r 6 r VIN_BO_TRIM1 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 47 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VIN_BO_TRIM2 (43h, 6bits) Set the trim value of the brown-out level of the input voltage at level two. The default setting for the -0001 version is 000000. Command Bit Access 7 r 6 r VIN_BO_TRIM2 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w OCP_LIMIT (44h, 7bits) Set the over-current limit of the inductor current. The default setting for the -0001 version is 0000100. Command Bit Access 7 r 6 r/w OCP_LIMIT 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w OCP_MODE (45h, 4bits) Set the over-current protection mode. The default setting for the -0001 version is 0000. Bit 3 2:0 Item Description OCP_MODE_EN 1: enable 0: disable OCP_MODE 000: latch 111: hiccup other: retry number Command Bit Access 7 r 6 r 5 r OCP_MODE 4 3 2 r r/w r/w 1 r/w 0 r/w OCP_RETRY_DELAY (47/46h, 10bits) Set the delay time of the system recovery after the OCP event is cleared. The default setting for the -0001 version is 0111110100. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r OCP_RETRY_DELAY 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w OVP_LIMIT_H (48h, 7bits) Set the over-voltage limit of the output voltage at high line. The default setting for the -0001 version is 1101101. Command Bit Access 7 r 6 r/w OVP_LIMIT_H 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w OVP_LIMIT_L (49h, 7bits) Set the over-voltage limit of the output voltage at low line. The default setting for the -0001 version is 1101101. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r 6 r/w 5 r/w OVP_LIMIT_L 4 3 2 r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 48 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 CODE ID (4Ah, 8bits) Store customer code ID. The default setting for the -0001 version is 00000001. Bit 7:2 1:0 Item CUSTOMER_ID PROGRAMMED CODE_ID Command Bit Access Description Customer number Programmed code number 7 r/w 6 r/w 5 r/w CODE ID 4 3 r/w r/w 2 r/w 1 r/w 0 r/w IREF_COMP_VALUE1 (4Bh, 7bits) Set the first compensation amplitude of the input current reference. The default setting for the -0001 version is 0000001. Command Bit Access 7 r 6 r/w IREF_COMP_VALUE1 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w IREF_COMP_VALUE2 (4Ch, 7bits) Set the second compensation amplitude of the input current reference. The default setting for the -0001 version is 0000011. Command Bit Access 7 r 6 r/w IREF_COMP_VALUE2 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w IREF_COMP_VALUE3 (4Dh, 7bits) Set the third compensation amplitude of the input current reference. The default setting for the -0001 version is 0001101. Command Bit Access 7 r 6 r/w IREF_COMP_VALUE3 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w IREF_COMP_VALUE4 (4Eh, 7bits) Set the fourth compensation amplitude of the input current reference. The default setting for the -0001 version is 0001100. Command Bit Access 7 r 6 r/w IREF_COMP_VALUE4 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w VIN_LEVEL_SEL1 (4Fh, 8bits) Set the first voltage level of the input voltage. The default setting for the -0001 version is 10011001. Command Bit Access 7 r/w 6 r/w VIN_LEVEL_SEL1 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w VIN_LEVEL_SEL2 (50h, 8bits) Set the second voltage level of the input voltage. The default setting for the -0001 version is 01001000. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w VIN_LEVEL_SEL2 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 49 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VCOMP_MAX_L (52/51h, 16bits) Set the maximum load. The default setting for the -0001 version is 0110110011010010. Command Bit Access 15 r/w 14 r/w 13 r/w 12 r/w 11 r/w 10 r/w VCOMP_MAX_L 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VCOMP_MAX_H (53h, 8bits) Set the maximum load. The default setting for the -0001 version is 01011001. Command Bit Access 7 r/w 6 r/w VCOMP_MAX_H 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w IREF_MAX (55/54h, 9bits) Set the maximum value of the input current reference. The default setting for the -0001 version is 111100100. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r IREF_MAX 8 7 6 r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w SYS_CONFIG (56h, 8bits) Configure the system. The default setting for the -0001 version is 00110100. Bit Item Description 7 BURST_LLC_SYNC_EN Synchronize PFC with LLC in burst mode. 1: enable 0: disable 6 ------ 5 POWER_ON 4 LLC_EN Enable LLC part. 1: enable 0: disable 3 AUTO_VOUT_EN Output voltage target is determined by the load. 1: enable 0: disable 2 IREF_COMP_EN Compensate the current of the input capacitance. 1: enable 0: disable 1 JITTER_EN Switching frequency jitter. 1: enable 0: disable 0 ZCD_EN Valley turn on. 1: enable 0: disable Reserved Power on the system. 1: enable 0: disable Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w SYS_CONFIG 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 50 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 AD_SLEEP_FS (58/57h, 10bits) Set the ADC sample rate when PWM is off. The default setting for the -0001 version is 1100100000. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r AD_SLEEP_FS 9 8 7 6 r/w r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w TON_AHEAD (59h, 4bits) Set the peak-current sample point. The default setting for the -0001 version is 0010. Command Bit Access 7 r 6 r 5 r TON_AHEAD 4 3 2 r r/w r/w 1 r/w 0 r/w OLP_HIGH (5Ah, 7bits) Set the open-loop protection at high level. The default setting for the -0001 version is 1011100. Command Bit Access 7 r 6 r/w 5 r/w OLP_HIGH 4 3 2 r/w r/w r/w 1 r/w 0 r/w OLP_LOW (5Bh, 7bits) Set the open-loop protection at low level. The default setting for the -0001 version is 0111101. Command Bit Access 7 r 6 r/w 5 r/w OLP_LOW 4 3 2 r/w r/w r/w 1 r/w 0 r/w SOFT_TON (5Ch, 7bits) Set the soft turn-on time when the system recovers from OVP. The default setting for the -0001 version is 0101000. Command Bit Access 7 r 6 r/w 5 r/w SOFT_TON 4 3 2 r/w r/w r/w 1 r/w 0 r/w SOFT_SWITCH_CNT (5Dh, 4bits) Set the number of switching events during soft turn on. The default setting for the -0001 version is 0111. Command Bit Access 7 r 6 r SOFT_SWITCH_CNT 5 4 3 2 1 r r r/w r/w r/w 0 r/w MFR_MERGE_REG (5Eh, 8bits) The default setting for the -0001 version is 00100001. Bit 7:3 2:1 0 Item SWITCH_BLANK_TIME1 Description PWM off blanking time CURRENT_MIRROR_GAIN Set the current mirror gain. The reference current is 62.5µA. 00: GAIN =1 01: GAIN = 1.4 10: GAIN = 1.6 11: GAIN = 2 I2C_FILTER_EN I2C filter. 1: enable 0: disable Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r/w 6 r/w MFR_MERGE_REG 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 51 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 SWITCH_BLANK_TIME (5Fh, 8bits) Set the PWM on blanking time. The default setting for the -0001 version is 00110101. Bit 7:4 3:0 Item SWITCH_BLANK_TIME2 SWITCH_BLANK_TIME3 Command Bit Access Description PWM off blanking time for OCP. PWM off blanking time for OCL. 7 r/w 6 r/w SWITCH_BLANK_TIME 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w OVP_DELAYTIME (60h, 6bits) Set the blanking time of OVP. The default setting for the -0001 version is 110010. Command Bit Access 7 r 6 r OVP_DELAYTIME 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w BURST_MODE_HYS (61h, 6bits) Set the hysteresis of the output voltage in burst mode. The default setting for the -0001 version is 001010. Command Bit Access 7 r 6 r BURST_MODE_HYS 5 4 3 2 1 r/w r/w r/w r/w r/w 0 r/w ERROR_ZERO_REGION (62h, 5bits) Set the non-regulation region of the output voltage. The default setting for the -0001 version is 00000. Command Bit Access 7 r ERROR_ZERO_REGION 6 5 4 3 2 1 r r r/w r/w r/w r/w 0 r/w VIN_ZERO_POINT (63h, 7bits) Set the period detection point of the input voltage. The default setting for the -0001 version is 1010010. Command Bit Access 7 r 6 r/w VIN_ZERO_POINT 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w VIN_PEAK_VALUE (64h, 7bits) Set the value to detect the top of the input voltage. The default setting for the -0001 version is 0010100. Command Bit Access 7 r 6 r/w VIN_PEAK_VALUE 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w VIN_VALLEY_VALUE (65h, 7bits) Set the value to detect the valley of the input voltage. The default setting for the -0001 version is 0111101. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r VIN_VALLEY_VALUE 6 5 4 3 2 1 r/w r/w r/w r/w r/w r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 52 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 IPK_BIAS_TRIM (66h, 8bits) Trim the bias voltage at CSP. The default setting for the -0001 version is 00000000. Bit Item Description 7 CSP_FAULT_MODE Determine the control mode when CSP is open or shorted. 1: hiccup 0: latch 6 IPK_BIAS_SAMPLE_EN Enable sampling of the CSP bias voltage when power is on. 1: enable 0: disable IPK_BISA_TRIM Trim the bias voltage at CSP. 5:0 Command Bit Access 7 r/w 6 r/w IPK_BIAS_TRIM 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w ADC_OFFSET_TRIM (67h, 5bits) Trim the ADC offset. The default setting for the -0001 version is 00000. Command Bit Access 7 r 6 r ADC_OFFSET_TRIM 5 4 3 2 1 r r/w r/w r/w r/w 0 r/w DELTA_VOLTAGE (68h, 7bits) Set the minimum delta voltage between the input voltage and output voltage for CSP bias voltage sampling. The default setting for the -0001 version is 0101001. Command Bit Access 7 r 6 r/w DELTA_VOLTAGE 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w VIN_LEVEL1 (69h, 7bits) Input voltage level one for the CSP bias voltage sample. The default setting for the -0001 version is 0010100. Command Bit Access 7 r 6 r/w 5 r/w VIN_LEVEL1 4 3 2 r/w r/w r/w 1 r/w 0 r/w VIN_LEVEL2 (6Ah, 7bits) Input voltage level two for the CSP bias voltage sample. The default setting for the -0001 version is 0101001. Command Bit Access 7 r 6 r/w 5 r/w VIN_LEVEL2 4 3 2 r/w r/w r/w 1 r/w 0 r/w VIN_LEVEL3 (6Bh, 7bits) Input voltage level three for the CSP bias voltage sample. The default setting for the -0001 version is 0111101. Command Bit Access HR1200 Rev 1.1 3/25/2020 7 r 6 r/w 5 r/w VIN_LEVEL3 4 3 2 r/w r/w r/w 1 r/w 0 r/w www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 53 HR1200 – HIGH-PERFORMANCE DIGITAL PFC+LLC COMBO CONTROLLER NOT RECOMMENDED FOR NEW DESIGNS. REFER TO HR1203 VIN_LEVEL4 (6D/6Ch, 10bits) Input voltage level four for the CSP bias voltage sample. The default setting for the -0001 version is 0100110011. Command Bit Access 15 r 14 r 13 r 12 r 11 r 10 r 9 r/w VIN_LEVEL4 8 7 6 r/w r/w r/w 5 r/w 4 r/w 3 r/w 2 r/w 1 r/w 0 r/w VIN_HL_HYS (6Eh, 8bits) Set the hysteresis of the input voltage for adaptive control. The default setting for the -0001 version is 00000101. Command Bit Access 7 r/w 6 r/w 5 r/w VIN_HL_HYS 4 3 2 r/w r/w r/w 1 r/w 0 r/w ZCD_VIN_HYS (6Fh, 6bits) Set the hysteresis of the input voltage for valley turn on. The default setting for the -0001 version is 010100. Command Bit Access 7 r 6 r ZCD_VIN_HYS 5 4 3 2 r/w r/w r/w r/w 1 r/w 0 r/w NOTICE: The information in this document is subject to change without notice. Users should warrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS products into any application. MPS will not assume any legal responsibility for any said applications. HR1200 Rev 1.1 3/25/2020 www.MonolithicPower.com MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. 54
MP6400DJ-12-LF-P 价格&库存

很抱歉,暂时无法提供与“MP6400DJ-12-LF-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货