ADC100 SERIES
1W, Miniature SIP, Single & Dual Output DC/DC Converters Selection Guide
Model Number ADC101 ADC102 ADC103 ADC104 ADC105 ADC106 ADC107 ADC108 ADC109 ADC111 ADC112 ADC113 ADC114 ADC115 ADC116 ADC117 ADC118 ADC119 ADC121 ADC122 ADC123 ADC124 ADC125 ADC126 ADC127 ADC128 ADC129 ADC151 ADC152 ADC153 ADC154 ADC155 ADC156 Input Voltage VDC Output Voltage VDC 3.3 5 9 12 15 ±5 ±9 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 5 12 15 ±5 ±12 ±15 Output Current mA 260 200 110 84 67 ±100 ±56 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 200 84 67 ±100 ±42 ±34 Efficiency % Typ. 73 71 76 78 78 72 77 78 79 74 73 78 80 80 74 79 81 81 73 71 76 78 79 72 76 79 80 72 79 79 72 80 80 Load Regulation % Max. 10 10 8 7 7 10 8 7 7 8 8 5 5 5 8 5 5 5 8 8 5 5 5 8 5 5 5 8 5 5 8 5 5
5 (4.5 – 5.5)
Key Features
• • • • • • • • • • Efficiency up to 81% 1000VDC Isolation MTBF > 2,000,000 Hours Low Cost Input 5, 12, 15 and 24VDC Output 3.3, 5, 9, 12, 15, ±5, ±9, ±12 and ±15VDC Temperature Performance -40°C to +85°C UL 94V-0 Package Material Internal SMD Construction Industry Standard Pinout
12 (10.8 – 13.2)
24 (21.6 – 26.4)
15 (13.5 – 16.5)
MPS Industries ADC100 1W DC/DC's are specially designed to provide the optimum cost/ benefit power solution in a miniature SIP package. The series consists of 33 models with input voltages of 5V, 12V, 15V and 24VDC which offers standard output voltages of 3.3V, 5V, 9V, 12V, 15V, ±5V, ±9V, ±12V and ±15VDC for a wide choice. The ADC100 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems.
2463 208th Street, Ste. 205 Torrance, CA 90501
Mechanical Dimensions
19.5 [0.77]
Pin Connections
Pin 1 2 4 5 6 Singles +Vin -Vin -Vout No Pin +Vout Duals +Vin -Vin -Vout Common +Vout
10.2 [0.40]
0.5 [0.02]
2.1 [0.08] 18.5 [0.73]
2.54 [0.100]
1
2
4
5
6
0.25 [0.010]
0.5 [0.020]
1.3 [0.05]
Case Size – 5V & 12V Input – 19.5x6.1x10.2mm (0.77x0.24x0.40inch) 15V & 24V Input –19.5x7.1x10.2mm (0.77x0.28x0.40inch) Case Material – Non-Conductive Black Plastic Weight – 5V & 12V Input – 2.2g (0.08Oz) 15V & 24V Input– 2.6g (0.09Oz) Tolerance Millimeters X.X±0.25 X.XX±0.13 ±0.05 Inches X.XX±0.01 X.XXX±0.005 ±0.002
3.2 [0.13] T
T= 6.1 (0.24) for 5V & 12V Input Models T= 7.1 (0.28) for 15V & 24V Input Models Pin
Tel: (310) 533-1455 Fax: (310) 533-1853
http://www.mpsind.com E-mail: sales@mpsind.com
ADC100 SERIES
1W, Miniature SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings
Parameter
5VDC Input Models Input Surge Voltage (1000mS) 12VDC Input Models 15VDC Input Models 24VDC Input Models Lead Temperature (1.5mm from case for 10sec.) Internal Power Dissipation
General Characteristics
Min.
-0.7 -0.7 -0.7 -0.7 -----
Max. Units
9 18 18 30 260 450 VDC VDC VDC VDC °C mW
Parameter
Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency MTBF
Conditions
60 Seconds 500VDC 100kHz, 1V
Min.
1000 1000 --70
Typ.
----60 100 ---
Max.
----100 120 ---
Units
VDC MΩ pF kHz MHrs
MIL-HDBK-217F @25°C Ground Benign
2
Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings.
Environmental Characteristics
Parameter
Operating Temperature Operating Temperature Storage Temperature Humidity Cooling
Output Characteristics
Max. Units
85 90 125 °C °C °C % Parameter Line Regulation Load Regulation Ripple & Noise Short Circuit Conditions For Vin Change of 1% Io = 20% to 100% 20MHz BW Min. --Typ. ±1.2 Max. ±1.5 Units % %
mV P-P
Conditions
Ambient Case
Min.
-40 -40 -40
See Selection Guide --50 75
--95 Free-Air Convection
0.5 Second Max.
Maximum Capacitive Load
Models by Output Voltage (Each Output on Duals) Singles 220 Duals 100 Units uF
Derating Curve
100 80 Output Power (%) 100LFM 400LFM 200LFM
Notes:
1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please visit our website.
60 Natural convection
40
20 0 -40
¡ã 50 60 70 80 ] 90 100 110
Ambient Temperature
2463 208th Street, Ste. 205 Torrance, CA 90501
Tel: (310) 533-1455 Fax: (310) 533-1853
http://www.mpsind.com E-mail: sales@mpsind.com
很抱歉,暂时无法提供与“ADC122”相匹配的价格&库存,您可以联系我们找货