0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ADC214

ADC214

  • 厂商:

    MPSIND

  • 封装:

  • 描述:

    ADC214 - 1W, High Isolation SIP, Single & Dual Output DC/DC Converters - MPS Industries, Inc.

  • 数据手册
  • 价格&库存
ADC214 数据手册
ADC200 SERIES 1W, High Isolation SIP, Single & Dual Output DC/DC Converters Selection Guide Model Number ADC201 ADC202 ADC203 ADC204 ADC205 ADC206 ADC207 ADC208 ADC209 ADC211 ADC212 ADC213 ADC214 ADC215 ADC216 ADC217 ADC218 ADC219 ADC221 ADC222 ADC223 ADC224 ADC225 ADC226 ADC227 ADC228 ADC229 Input Voltage VDC Output Voltage VDC 3.3 5 9 12 15 ±5 ±9 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 3.3 5 9 12 15 ±5 ±9 ±12 ±15 Output Current mA 260 200 110 84 67 ±100 ±56 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 260 200 110 84 67 ±100 ±56 ±42 ±34 Efficiency % Typ. 73 71 76 78 78 72 77 78 79 74 73 78 80 80 74 79 81 81 73 71 76 78 79 72 76 79 80 Load Regulation % Max. 10 10 8 7 7 10 8 7 7 8 8 5 5 5 8 5 5 5 8 8 5 5 5 8 5 5 5 5 (4.5 – 5.5) Key Features • • • • • • • • • • Efficiency up to 81% 3000VDC Isolation MTBF > 2,000,000 Hours Low Cost Input 5, 12 and 24VDC Output 3.3, 5, 9, 12, 15, ±5, ±9, ±12 and ±15VDC Temperature Performance -40°C to +85°C UL 94V-0 Package Material Internal SMD Construction Industry Standard Pinout 12 (10.8 – 13.2) 24 (21.6 – 26.4) The series consists of 27 models with input voltages of 5V, 12V and 24VDC which offers standard output voltages of 3.3V, 5V, 9V, 12V, 15V, ±5V, ±9V, ±12V and ±15VDC for a wide choice. The ADC200 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems. 2463 208th Street, Ste. 205 Torrance, CA 90501 10.2 [0.40] MPS Industries ADC200 1W DC/DC's are specially designed to provide high levels of isolation 3000VDC in a miniature SIP package. Mechanical Dimensions 19.5 [0.77] Pin Connections Pin Singles Duals 0.5 [0.02] 1 2 5 6 7 +Vin -Vin -Vout No Pin +Vout +Vin -Vin -Vout Common +Vout 2.1 [0.08] 18.5 [0.73] 2.54 [0.100] 1 2 5 6 7 0.25 [0.010] 0.50 [0.020] 1.3 [0.05] Case Size – 5V & 12V Input – 19.5x6.1x10.2mm (0.77x0.24x0.40inch) 24V Input –19.5x7.1x10.2mm (0.77x0.28x0.40inch) Case Material – Non-Conductive Black Plastic Weight – 5V & 12V Input – 2.2g (0.08Oz) 24V Input– 2.6g (0.09Oz) Tolerance Millimeters X.X±0.25 X.XX±0.13 ±0.05 Inches X.XX±0.01 X.XXX±0.005 ±0.002 T= 6.1 (0.24) for 5V & 12V Input Models T= 7.1 (0.28) for 24V Input Models Pin T 3.2 [0.13] Tel: (310) 533-1455 Fax: (310) 533-1853 http://www.mpsind.com E-mail: sales@mpsind.com ADC200 SERIES 1W, High Isolation SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings Parameter 5VDC Input Models Input Surge Voltage 12VDC Input Models (1000mS) 24VDC Input Models Lead Temperature (1.5mm from case for 10sec.) Internal Power Dissipation General Characteristics Min. -0.7 -0.7 -0.7 ----- Max. Units 9 18 30 260 450 VDC VDC VDC °C mW Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency MTBF Conditions 60 Seconds 500VDC 100kHz, 1V Min. 3000 10 --70 Typ. ----60 100 Max. ----100 120 Units VDC GΩ pF kHz Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. MIL-HDBK-217F @25°C Ground Benign 2 --- --- MHrs Environmental Characteristics Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling Output Characteristics Max. Units 85 90 125 °C °C °C % Parameter Line Regulation Load Regulation Ripple & Noise Short Circuit Conditions For Vin Change of 1% Io = 20% to 100% 20MHz BW Min. --Typ. ±1.2 Max. ±1.5 Units % % mV P-P Conditions Ambient Case Min. -40 -40 -40 See Selection Guide --65 100 --95 Free-Air Convection 0.5 Second Max. Maximum Capacitive Load Derating Curve (3.3, 5 & ±5V Outputs) 100 80 Output Power (%) 100LFM Natural convection 200LFM Models by Output Voltage (Each Output on Duals) Singles 220 Duals 100 Units uF 400LFM 60 Notes: 1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please visit our website. 40 20 0 -40 ¡ã 50 60 70 80 ] 90 100 110 Ambient Temperature Derating Curve (Other Outputs) 100 80 Output Power (%) 100LFM 400LFM 200LFM 60 Natural convection 40 20 0 -40 ¡ã 50 60 70 80 ] 90 100 110 Ambient Temperature 2463 208th Street, Ste. 205 Torrance, CA 90501 Tel: (310) 533-1455 Fax: (310) 533-1853 http://www.mpsind.com E-mail: sales@mpsind.com
ADC214 价格&库存

很抱歉,暂时无法提供与“ADC214”相匹配的价格&库存,您可以联系我们找货

免费人工找货