WIDE BAND ISOLATION TRANSFORMER
R3600 SERIES
• For RF, DS3/E3, Boradband, BPL and Ethernet Magnetics which require Supplementary or Reinforced Isolation • Construction complies with IEC60950 Isolation requirement
• RoHS Compliant Product • Operating Temp : 0°C to 70°C (extended temperature subject to request)
ELECTRICAL SPECIFICATION @ 25°C
PART NO Turns Ratio Pri : Sec ±5% 1:1 1CT:1CT 1:2 1:1:1 3:3:1 1:1.224 Pri OCL (µH) Min 1-4 500 800 120 120 200 500 Pri DCR (W ) Max 1-4 0.30 0.50 0.20 0.20 0.30 0.50 Insertion Loss Insertion Loss Insertion Loss dB Max dB Max dB Typ 1MHz -0.5 -0.5 -0.8 -0.8 -0.5 -0.8 100MHz -1.0 -1.2 -1.0 -1.0 -1.0 -1.0 300MHz -2.6 -3.5 -1.5 -1.5 -3.0 -3.0 Hipot VRMS Pri to Sec 4500 3000 4500 4500 3000 3000 B A B C C B Schematic
R36001 2 3 4 5 6
Note: • OCL measured @ 100KHz, 0.1VRMS at Pin 1-4 (with 2-3 shorted) • Insertion Loss measured with 100W as Input (Primary) Impedance between 1-4 and Output (Secondary) load with respective impedance • 50W and 75W impedance data available upon request
Mechanical
Schematic
Schematic A
Schematic B
Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ± 0.015 .XXX : ±0.004 mm: X,X : ± 0,38 X,XX : ±0,10
Schematic C
R3600-XX 1004JW
Product performance is limited to specified parameter. Data is subject to change without prior notice.
2570 W. 237th Street, Suite B Torrance, CA 90505
Tel: (310) 325-1043 Fax: (310) 325-1044
www.mpsind.com sales@mpsind.com