0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NC316MB-2

NC316MB-2

  • 厂商:

    MRV

  • 封装:

  • 描述:

    NC316MB-2 - Fiber Driver® Chassis - MRV Communications, Inc.

  • 数据手册
  • 价格&库存
NC316MB-2 数据手册
Media Converters Repeaters and Optimizers Datasheet Fiber Driver® Chassis Features FD Models with 1, 2, 3, 4, or 16 slots Rack mounting options ¹ Wall mounting options ² Module flexibility; no slot dependency within a chassis Hot-swap support Management module compatibility ³ - fan status - power supply status - temperature status - high and low temperature limits - SNMP traps to report faults AC or DC redundant power supply pairs Optional front cable management tray for NC316BU-16 chassis Overview The Fiber Driver® chassis is the foundation for deploying and managing the Fiber Driver media module product family. Chassis are available with one, two, three, four, and sixteen slots. The three-slot (NC316BU-3), four-slot (NC316BU-4 and NC316BU-4S), sixteen-slot (NC316BU-16) and sixteen-slot Telco (NC316BU-16T) chassis can be equipped with redundant, hot-swappable AC or DC internal power supplies. The two-slot NC316BU-2 and one-slot NC316BU-1 come with a single AC or DC internal power supply. The NC316BU-1/NP and NC316BU4PMC/NP chassis are designed to host fully passive modules such as the Fiber Driver Splitter/Combiner. Because fully passive solutions require no external power source, these chassis include no power supply. ¹ three-slot, four-slot, and sixteen-slot models ² one-slot and two-slot models ³ two-slot, three-slot, four-slot, and sixteen-slot chassis models ONE-SLOT CHASSIS THREE-SLOT CHASSIS SIXTEEN-SLOT CHASSIS FOUR-SLOT CHASSIS TWO-SLOT CHASSIS SIXTEEN-SLOT TELCO 23” CHASSIS sales@mrv.com Media Converters Repeaters and Optimizers Chassis with two, three, four and sixteen slots can accommodate a network management module. EM316NM and EM316LNXNM-OT provide monitoring of system temperature, fan status, and power supply. The NC316BU-4, NC316BU-4S, and NC316BU-16 mount in 19” racks. The NC316BU-3 and NC316BU-16T, have reduced depth form-factors and front-loaded power supplies for Telco installations. These models mount in 23” racks, and the NC316BU-3 can also mount in 19” racks. The one-slot chassis is suitable for unmanaged use in standalone applications. The NC316BU-2 is designed for single-module managed and two-module unmanaged standalone applications. Contact your nearest MRV representative for information on Fiber Driver or other products. REDUNDANT POWER SUPPLIES Model Description Redundant Power Supply for NC316BU-3/AC Redundant Power Supply for NC316BU-3/DC Redundant Power Supply for NC316BU-4/AC Redundant Power Supply for NC316BU-4/DC Redundant Power Supply for NC316BU-4S/AC Redundant Power Supply for NC316BU-4S/DC Redundant Power Supply for NC316BU-16/AC Redundant Power Supply for NC316BU-16/DC Redundant Power Supply for NC316BU-16T/DC Ordering Information NC316-3RPSAC NC316-3RPSDC NC316-4RPSAC NC316-4RPSDC NC316BU-4SRPSAC NC316BU-4SRPSDC NC316-16RPSAC NC316-16RPSDC NC316-16T/DC ACCESSORIES Model NC316RB23-3 NC316RB23-4 NC316-16BRACKET NC316RB23-16 NC316MB-1 NC316MB-2 NC316BP-1 NC316BP-4 NC316DCC NC316BU-16CMT NC316-16DOOR Description Rack Mount Bracket for NC316BU-3/AC or -3/DC Telco Chassis; 23” Rack Mount Bracket for NC316BU-4/AC or -4/DC Telco Chassis; 23” Rack Mount Bracket for 16-slot Chassis Rack Mount Bracket for NC316BU-16/AC Chassis, 23” Wall Mount Bracket for NC316BU-1 Wall Mount Bracket for NC316BU-2 Blank Panel, Single-Slot Wide, for NC316BU Blank Panel, Four-Slot Wide, for NC316BU-16 DC Power Female Connector (WAGO) Cable Management Tray for the NC316BU-16 Chassis Cable Management Tray and transparent door for the NC316BU-16 Chassis Ordering Information sales@mrv.com Media Converters Repeaters and Optimizers CHASSIS Model NC316BU-1/AC NC316BU-1/DC NC316BU-1/AC/EU NC316BU-1HP/AC Description One-slot, AC power One-slot, DC power One-slot, VAC power (European version) One-slot, AC power One-slot, DC power One-slot, no power supply (passive application only) Two-slot, AC power Two-slot, DC power Three-slot Telco, for19” rack, AC power Three-slot Telco, for19” rack, DC power Four-slot, for 19” rack, AC power Four-slot, for 19” rack, DC power Four-slot, for 19” rack, AC power Four-slot, for 19” rack, DC power Non-managed, non-powered four-slot chassis for passive Mux/Demux modules Sixteen-slot, for 19” rack, AC power Sixteen-slot, for 19” rack, DC power Sixteen-slot Telco, for 23” rack, DC power Physical Dimensions (hight x width x depth) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”) 44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”) 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 44 mm x 441 mm x 286 mm (1.73” x 17.36” x 11.26”) 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 132 mm x 541 mm x 254 mm (5.20” x 21.30” x 10.00”) Weight 1.0 kg (2.2 lbs) 1.0 kg (2.2 lbs) 1.0 kg (2.2 lbs) 1.0 kg (2.2 lbs) 1.0 kg (2.2 lbs) 1.0 kg (2.2 lbs) 1.4 kg (3.1 lbs) 1.4 kg (3.1 lbs) 3.1 kg (6.8 lbs) 3.0 kg (6.6 lbs) 7.7 kg (17.0 lbs) 7.7 kg (17.0 lbs) 4.5 kg (9.9 lbs) 4.5 kg (9.9 lbs) 4.3 kg (9.6 lbs) 8.8 kg (19.4 lbs) 8.7 kg (19.2 lbs) 8.2 kg (18.1 lbs) Ordering Information NC316BU-1HP/DC NC316BU-1/NP NC316BU-2/AC NC316BU-2/DC NC316BU-3/AC NC316BU-3/DC NC316BU-4/AC NC316BU-4/DC NC316BU-4S/AC NC316BU-4S/DC NC316BU4PMC/NP NC316BU-16/AC NC316BU-16/DC NC316BU-16T/DC sales@mrv.com Media Converters Repeaters and Optimizers POWER SUPPLY SPECIFICATIONS Model Nominal Input Range (VAC) 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz 100 - 240 @ 50/60 Hz - Input Range (VDC)* 40.5 - 57 40.5 - 57 40.5 - 57 40.5 - 57 40.5 - 57 40.5 - 57 40.5 - 57 40.5 - 57 Maximum Rating (Amps) 0.3 0.5 0.3 0.3 0.5 0.6 1.0 1.6 2.0 4.0 2.0 1.8 2.0 3.5 5.0 or 6.5 5.0 Operating Temperature 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) 0 to +50°C (+32 to +122°F) 0 to +50°C (+32 to +122°F) -40 to +65°C (-40 to +149°F) 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) 0 to +50°C (+32 to +122°F) -35 to +60°C (-31 to +140°F) -35 to +60°C (-31 to +140°F) Storage Temperature -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -20 to +70°C (0 to +154°F) -20 to +70°C (0 to +154°F) -45 to +75°C (-49 to +167°F) -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -20 to +70°C (0 to +154°F) -35 to +70°C (-31 to +158°F) -35 to +70°C (-31 to +158°F) Relative Humidity < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing < 85% non condensing NC316BU-1/AC NC316BU-1/DC NC316BU-1/AC/EU NC316BU-1HP/AC NC316BU-1HP/DC Ordering Information NC316BU-2/AC NC316BU-2/DC NC316BU-3RPSAC NC316BU-3RPSDC NC316BU-4RPSAC NC316BU-4RPSDC NC316BU-4SRPSAC NC316BU-4SRPSDC NC316BU-16RPSAC NC316BU-16RPSDC NC316BU-16T/DC * Compliant with ANSI TI.315-1994 standard Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV CUE Mark (Canada, USA, EU); GOST (selected products); RoHS Directive, WEEE Directive: Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick (selected products). Contact your sales representative for details. MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com. Please e-mail us at sales@mrv.com or call us for assistance. MRV (West Coast USA) 20415 Nordhoff St. Chatsworth, CA 91311 800-338-5316 818-773-0900 MRV (East Coast USA) 295 Foster St. Littleton, MA 01460 800-338-5316 978-952-4700 MRV (International) Business Park Moerfelden Waldeckerstrasse 13 64546 Moerfelden-Walldorf Germany Tel. (49) 6105/2070 Fax. (49) 6105/207-100 All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-FD-CHASS-120506 1398005-001 Rev. B Copyright ©2006 MRV Communications, Inc. All Rights Reserved.
NC316MB-2 价格&库存

很抱歉,暂时无法提供与“NC316MB-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货