0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
35-JC6DT3

35-JC6DT3

  • 厂商:

    MTU

  • 封装:

  • 描述:

    35-JC6DT3 - DIESEL ENGINE-GENERATOR SET - MTU Onsite Energy Corporation

  • 数据手册
  • 价格&库存
35-JC6DT3 数据手册
A tognum grouP BrAnd DIESEL ENGINE-GENERATOR SET 35-JC6DT3 35 ekW /60 Hz /Standby 30 ekW /60 Hz /Prime 208 - 600V SySTEm RATINGS Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1.0 60 35 35 146 52 361CSL1600 130°C/27°C 12 LEAD ZIG-ZAG 240V** 1 1.0 60 35 35 146 99 284CSL1550 130°C/27°C 4 LEAD 208V** 3 0.8 60 35 43.75 121 92 284CSL1508 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 35 43.75 105 122 284CSL1508 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 35 43.75 53 122 284CSL1508 130°C/27°C 12 LEAD HI WYE 600V** 3 0.8 60 35 43.75 42 123 284PSL1752 125°C/40°C 4 LEAD WYE Prime Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V 1 1.0 60 30 30 125 66 361CSL1600 105°C/40°C 12 LEAD ZIG-ZAG 240V 1 1.0 60 30 30 125 102 284CSL1550 105°C/40°C 4 LEAD 208V 3 0.8 60 30 37.5 104 93 284CSL1508 105°C/40°C 12 LEAD LOW WYE 240V 3 0.8 60 30 37.5 90 93 284CSL1508 105°C/40°C 12 LEAD HI DELTA 480V 3 0.8 60 30 37.5 45 123 284CSL1508 105°C/40°C 12 LEAD HI WYE 600V 3 0.8 60 30 37.5 36 123 284PSL1752 105°C/40°C 4 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered 2 // / / 35-JC6dt3 FACTS // // // // // // // // // // EPA Tier 3 Certified Engine-Generator Set Tested to ISO 8528-5 for Transient Response UL2200, CSA Listing Offered Accepts Rated Load in One Step Per NFPA 110, Level 1 All engine-generator sets are prototype and factory tested MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty Custom Design for Any Application 4024HF285 Diesel Engine - 2.4 Liter Displacement - Electronic Unit Pump Injection - 4-Cycle Complete Range of Accessories Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings // Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan // // STANDARD EQUIPmENT // Engine Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±1% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content Air Cleaner Oil Pump Full Flow Oil Filter Jacket Water Pump Thermostat Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Electric Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // digital Control Panel(s) // generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible 3 // / / 35-JC6dt3 APPLICATION DATA // Engine John Deere 4024HF285 4-Cycle 4 In-Line 146 (2.4) 3.4 (8.6) 4.1 (10.5) 18.2:1 1,800 JDEC 80 (60) 74 (55) ±.25% 60 Hz Dry // Fuel Consumption STANDBY 3.2 (12.1) 2.2 (8.3) 1.2 (4.5) PRIME 2.9 (11) 2 (7.6) 1.1 (4.2) Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Max Power: Prime: bhp (kWm) Regulation Frequency Air Cleaner At 100% of Power Rating: gal/hr (lit/hr) At 75% of Power Rating: gal/hr( lit/hr) At 50% of Power Rating: gal/hr (lit/hr) // Cooling - radiator System STANDBY 122 (50) 0.5 (0.12) 26 (100) 1,326 (23.3) 412 (7.2) 377 (6.6) PRIME 122 (50) 0.5 (0.12) 26 (100) 1,127 (19.8) 350 (6.2) 318 (5.6) Ambient Capacity of Radiator: °F (°C) Maximum Allowable Static Pressure on Rad. Exhaust: in. H20 (kPa) Water Pump Capacity: gpm (lit/min) Heat Rejection to Coolant: BTUM (kW) Heat Rejection to Air to Air: BTUM (kW) Heat Radiated to Ambient: BTUM (kW) // Liquid Capacity (Lubrication) // Air requirements STANDBY 133 (3.8) 4,511 (128) PRIME 126 (3.6) 4,511 (128) Total Oil System: gal (lit) Engine Jacket Water Capacity: gal (lit) System Coolant Capacity: gal (lit) 2.1 (7.9) 0.68 (2.6) 3 (11.4) // Electrical 12 750 Electric Volts DC Cold Cranking Amps Under 0°F (-17.8°C) Aspirating: *SCFM (m3/min) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 851 (24) 716 (20) // // Fuel System 3/8” NPT 3/8” NPT 10 (3) Diesel #2 21.7 (82) Exhaust System STANDBY 1,008 (542) 354 (10) 30 (7.5) 16 (4) PRIME 988 (531) 326 (9.2) 30 (7.5) 16 (4) Fuel Supply Connection Size Fuel Return Connection Size Maximum Fuel Lift: ft (m) Recommended Fuel Total Fuel Flow: gal/hr (lit/hr) Gas Temp. (Stack): °F (°C) Gas Volume at Stack Temp: CFM (m3/min) Maximum Allowable Back Pressure: in. H20 (kPa) Minimum Allowable Back Pressure: in. H20 (kPa) 4 // / / 35-JC6dt3 WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. System OPU dimensions (L x W x H) 82 x 34 x 48.38 in (2,080 x 860 x 1,230 mm) Weight (less tank) 1,379 lb (626 kg) Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. SOUND DATA unit type OPU w/Critical Grade Muffler (dBA) Sound Attenuated Enclosure (dBA) Measurements for sound data are taken at 23 ft (7 m). Standby Full Load 84.3 76.3 Standby no Load 80 72 Prime Full Load 83.1 75.1 Prime no Load 80 72 © MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 EmISSIONS DATA nox + nmHC 3.50 Co 0.86 Pm 0.12 RATING DEFINITIONS AND CONDITIONS Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. // Deration Factor: Altitude: 0.5% per 1,000 ft (305 m) above sea level and 4% per 1,000 ft (305 m) above 10,000 ft (3,050 m). temperature: 0.5% per 10°F (5.5°C) above 77°F (25°C). // All units are in g/hp-hr and are EPA d2 cycle values. Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaranteed to be below the US EPA Standards at the US EPA defined conditions. Materials and specifications subject to change without notice. // tognum group Companies: Europe / middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // uSA / Canada / mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for Hotmodule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com
35-JC6DT3 价格&库存

很抱歉,暂时无法提供与“35-JC6DT3”相匹配的价格&库存,您可以联系我们找货

免费人工找货