450-XC6DT3

450-XC6DT3

  • 厂商:

    MTU

  • 封装:

  • 描述:

    450-XC6DT3 - DIESEL ENGINE-GENERATOR SET - MTU Onsite Energy Corporation

  • 数据手册
  • 价格&库存
450-XC6DT3 数据手册
A tognum grouP BrAnd DIESEL ENGINE-GENERATOR SET 450-XC6DT3 450 ekW /60 Hz /Standby 415 ekW /60 Hz /Prime 208 - 4160V SySTEm RATINGS Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V** 1 1.0 60 450 450 1875 770 574RSL4037 130°C/27°C 12 LEAD ZIG-ZAG 208V** 3 0.8 60 450 562.5 1561 1300 572RSL4027 130°C/27°C 12 LEAD LOW WYE 240V** 3 0.8 60 450 562.5 1353 1320 572RSL4027 130°C/27°C 12 LEAD HI DELTA 480V** 3 0.8 60 450 562.5 677 1100 572RSL4025 130°C/27°C 12 LEAD HI WYE 600V** 3 0.8 60 450 562.5 541 1040 572RSS4270 125°C/40°C 4 LEAD WYE 4160V 3 0.8 60 450 562.5 78 1240 573FSM4354 130°C/27°C 6 LEAD WYE Prime Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model* Temp Rise Connection 240V 1 1.0 60 415 415 1729 770 574RSL4037 105°C/40°C 12 LEAD ZIG-ZAG 208V 3 0.8 60 415 518.75 1440 1300 572RSL4027 105°C/40°C 12 LEAD LOW WYE 240V 3 0.8 60 415 518.75 1248 1320 572RSL4027 105°C/40°C 12 LEAD HI DELTA 480V 3 0.8 60 415 518.75 624 1100 572RSL4025 105°C/40°C 12 LEAD HI WYE 600V 3 0.8 60 415 518.75 499 1040 572RSS4270 105°C/40°C 4 LEAD WYE 4160V 3 0.8 60 415 518.75 72 1240 573FSM4354 105°C/40°C 6 LEAD WYE * The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration. ** UL2200 Offered 2 // / / 450-XC6dt3 FACTS // // // // // // // // // // EPA Tier 3 Certified Engine-Generator Set Tested to ISO 8528-5 for Transient Response UL2200, CSA Listing Offered Accepts Rated Load in One Step Per NFPA 110, Level 1 All engine-generator sets are prototype and factory tested MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty Custom Design for Any Application Series 60 (6063HV35) Diesel Engine - 14.0 Liter Displacement - Electronic Unit Pump Injection - 4-Cycle Complete Range of Accessories Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings // Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display // Cooling System - Integral Set-Mounted - Engine Driven Fan // // STANDARD EQUIPmENT // Engine Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±.25% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content Air Cleaners Oil Pump Full Flow Oil Filter Jacket Water Pump Thermostat Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 24V Governor – Electric Isochronous Base - Structural Steel SAE Flywheel & Bell Housing Charging Alternator - 24V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // digital Control Panel(s) // generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible 3 // / / 450-XC6dt3 APPLICATION DATA // Engine MTU Detroit Diesel Series 60 (6063HV35) 4-Cycle 6-Inline 855 (14) 5.24 (13.3) 6.61 (16.8) 16:1 1,800 DDEC 685 (511) 623 (465) ±.25% 60 Hz Dry // Fuel Consumption STANDBY 34.6 (131) 26.4 (100) 18.2 (69) PRIME 32.3 (122) 24.3 (92) 16.4 (62) Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Max Power: Prime: bhp (kWm) Regulation Frequency Air Cleaner At 100% of Power Rating: gal/hr (lit/hr) At 75% of Power Rating: gal/hr( lit/hr) At 50% of Power Rating: gal/hr (lit/hr) // Cooling - radiator System STANDBY 122 (50) 0.5 (0.12) 96 (363) 9,400 (165) 7,250 (127) 6,145 (108) PRIME 122 (50) 0.5 (0.12) 96 (363) 9,300 (163) 5,950 (105) 5,835 (102.6) Ambient Capacity of Radiator: °F (°C) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) Water Pump Capacity: gpm (lit/min) Heat Rejection to Coolant: BTUM (kW) Heat Rejection to Air to Air: BTUM (kW) Heat Radiated to Ambient: BTUM (kW) // Liquid Capacity (Lubrication) 9.5 (36) 6 (23) 42 (159) // Air requirements STANDBY 1,395 (39.5) PRIME 1,345 (38.1) Total Oil System: gal (lit) Engine Jacket Water Capacity: gal (lit) System Coolant Capacity: gal (lit) // Electrical 24 1,250 Aspirating: *SCFM (m3/min) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 25,304 (717) 25,304 (717) 13,859 (395) 13,160 (375) Electric Volts DC Cold Cranking Amps Under 0°F (-17.8°C) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) // // Fuel System 1/2” NPT 1/2” NPT 6.8 (2.1) Diesel #2 90.8 (344) Exhaust System STANDBY 1,058 (570) PRIME 980 (527) Fuel Supply Connection Size Fuel Return Connection Size Maximum Fuel Lift: ft (m) Recommended Fuel Total Fuel Flow: gal/hr (lit/hr) Gas Temp. (Stack): °F (°C) Gas Volume at Stack Temp: CFM (m3/min) Maximum Allowable Back Pressure: in. H20 (kPa) 3,973 (112.5) 3,630 (102.8) 40.8 (10.2) 40.8 (10.2) 4 // / / 450-XC6dt3 WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. System OPU dimensions (L x W x H) 140 x 57 x 79.6 in (3,556 x 1,448 x 2,022 mm) Weight (less tank) 6,726 lb (3,051 kg) Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. SOUND DATA unit type OPU w/Critical Grade Muffler (dBA) Sound Attenuated Enclosure (dBA) Measurements for sound data are taken at 23 ft (7 m). Standby Full Load 97.5 89.5 Standby no Load 89 81 Prime Full Load 96 88 Prime no Load 89 81 © MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 EmISSIONS DATA nox + nmHC 2.8 Co 0.8 Pm 0.13 RATING DEFINITIONS AND CONDITIONS Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. // Deration Factor: Altitude: 1% per 1,000 ft (305 m) above 600 ft (183 m). temperature: 1% per 10°F (5.5°C) above 77°F (25°C). // All units are in g/hp-hr and are EPA d2 cycle values. Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaranteed to be below the US EPA Standards at the US EPA defined conditions. Materials and specifications subject to change without notice. // tognum group Companies: Europe / middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // uSA / Canada / mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for Hotmodule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@cfc-solutions.com //www.mtu-online.com
450-XC6DT3 价格&库存

很抱歉,暂时无法提供与“450-XC6DT3”相匹配的价格&库存,您可以联系我们找货

免费人工找货