597PF000189DGR

597PF000189DGR

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    SMD7050_8P

  • 描述:

    频率稳定度:±50ppm;工作电压:3.3V;供电电流:100mA;输出模式:CMOS;工作温度:-40℃~+85℃;

  • 数据手册
  • 价格&库存
597PF000189DGR 数据手册
Si 5 97 Q UAD F R E Q U E N C Y V O LTAG E - C O N T R O L L E D C RYS TAL O S C I L L ATO R ( V C X O ) 1 0 TO 8 1 0 M H Z Features   Available with any-frequency output from 10 to 810 MHz  4 selectable output frequencies  3rd generation DSPLL® with superior jitter performance  Internal fixed fundamental mode crystal frequency ensures high reliability and low aging     Available CMOS, LVPECL, LVDS, and CML outputs 3.3, 2.5, and 1.8 V supply options Industry-standard 5 x 7 mm package and pinout Pb-free/RoHS-compliant –40 to +85 ºC operating range Si5602 Ordering Information: Applications See page 8.    SONET/SDH (OC-3/12/48) Networking SD/HD SDI/3G SDI video    OTN Clock recovery and jitter cleanup PLLs FPGA/ASIC clock generation Description The Si597 quad frequency VCXO utilizes Skyworks Solutions’ advanced DSPLL® circuitry to provide a low-jitter clock for all output frequencies. The Si597 is available with one of four pin-selectable ouput frequencies from 10 to 810 MHz. Unlike traditional VCXOs, where a different crystal is required for each output frequency, the Si597 uses one fixed crystal to provide a wide range of output frequencies. This IC-based approach allows the crystal resonator to provide exceptional frequency stability and reliability. In addition, DSPLL clock synthesis provides supply noise rejection, simplifying the task of generating low-jitter clocks in noisy environments. The Si597 ICbased quad frequency VCXO is factory-configurable for a wide variety of user specifications including frequencies, supply voltage, output format, tuning slope, and absolute pull range (APR). Specific configurations are factory programmed at time of shipment, thereby eliminating the long lead times associated with custom oscillators. Pin Assignments: See page 7. (Top View) FS[1] 7 VC 1 6 VDD OE 2 5 CLK– GND 3 4 CLK+ 8 FS[0] Functional Block Diagram V DD PPoowweerr SSuupppplyly FFilte ilterin ringg OE CLK+ F ixe d F re q u e n cy O s cilla to r Vc A n y F re q u e n c y 10–810 M H z DSPLL C lo c k S y n th e s is CLK- ADC C o n tro l GND FS0 FS1 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si5 97 TA B L E O F C O N T E N T S Section Page 1. Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2. Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 3. Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 4. Outline Diagram and Suggested Pad Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 5. 8-Pin PCB Land Pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 6. Si597 Mark Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si597 1. Electrical Specifications Table 1. Recommended Operating Conditions Parameter Supply Voltage1 Supply Current Symbol Test Condition Min Typ Max Unit VDD 3.3 V option 2.97 3.3 3.63 V 2.5 V option 2.25 2.5 2.75 V 1.8 V option 1.71 1.8 1.89 V Output enabled LVPECL CML LVDS CMOS — — — — 120 110 100 90 135 120 110 100 mA mA mA mA Tristate mode — 60 75 mA VIH 0.75 x VDD — — V VIL — — 0.5 V –40 — 85 °C IDD Output Enable (OE)2 and Frequency Select (FS[1:0]) Operating Temperature Range TA Notes: 1. Selectable parameter specified by part number. See 3. "Ordering Information" on page 8 for further details. 2. OE pin includes an internal 17 k pullup resistor to VDD for output enable active high or a 17 k pull-down resistor to GND for output enable active low. See 3. "Ordering Information" on page 8. FS[1:0] includes internal 17 kpull-up to VDD. Table 2. VC Control Voltage Input Parameter Symbol Test Condition Min Typ Max Unit Control Voltage Tuning Slope KV 10 to 90% of VDD — — — — — 45 95 125 185 380 — — — — — ppm/V Control Voltage Linearity4 LVC BSL –5 ±1 +5 % Incremental –10 ±5 +10 % 1,2,3 Modulation Bandwidth BW 9.3 10.0 10.7 kHz VC Input Impedance ZVC 500 — — k VC Input Capacitance CVC — 50 — pF — VDD/2 — V 0 — VDD V Nominal Control Voltage Control Voltage Tuning Range VCNOM VC @ fO Notes: 1. Positive slope; selectable option by part number. See 3. "Ordering Information" on page 8. 2. For best jitter and phase noise performance, always choose the smallest KV that meets the application’s minimum APR requirements. See “AN266: VCXO Tuning Slope (KV), Stability, and Absolute Pull Range (APR)” for more information. 3. KV variation is ±10% of typical values. 4. BSL determined from deviation from best straight line fit with VC ranging from 10 to 90% of VDD. Incremental slope determined with VC ranging from 10 to 90% of VDD. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 3 Si5 97 Table 3. CLK± Output Frequency Characteristics Parameter Nominal Frequency1,2,3 Temperature Symbol Test Condition Min Typ Max Unit fO LVDS/CML/LVPECL 10 — 810 MHz CMOS 10 — 160 MHz TA = –40 to +85 ºC –20 –50 — — +20 +50 ppm ppm VDD = 3.3 V ±15 — ±370 ppm — — 10 ms Stability1,4 Absolute Pull Range1,4 APR Power up Time5 tOSC Notes: 1. See Section 3. "Ordering Information" on page 8 for further details. 2. Specified at time of order by part number. 3. Nominal output frequency set by VCNOM = VDD/2. 4. Selectable parameter specified by part number. See “Ordering Information”. 5. Time from power up or tristate mode to fO. Table 4. CLK± Output Levels and Symmetry Parameter LVPECL Output Option 1 LVDS Output Option2 CML Output Option2 Symbol Test Condition Min Typ Max Unit VO mid-level VDD – 1.42 — VDD – 1.25 V VOD swing (diff) 1.1 — 1.9 VPP VSE swing (single-ended) 0.55 — 0.95 VPP VO mid-level 1.125 1.20 1.275 V VOD swing (diff) 0.5 0.7 0.9 VPP VO 2.5/3.3 V option mid-level — VDD – 1.30 — V 1.8 V option mid-level — VDD – 0.36 — VPP 2.5/3.3 V option swing (diff) 1.10 1.50 1.90 V 1.8 V option swing (diff) 0.35 0.425 0.50 VPP VOH 0.8 x VDD — VDD V VOL — — 0.4 V LVPECL/LVDS/CML — — 350 ps CMOS with CL = 15 pF — 2 — ns 45 — 55 % VOD CMOS Output Option 3 Rise/Fall time (20/80%) Symmetry (duty cycle) tR, tF SYM LVPECL: LVDS: CMOS: VDD – 1.3 V (diff) 1.25 V (diff) VDD/2 Notes: 1. 50  to VDD – 2.0 V. 2. Rterm = 100  (differential). 3. CL = 15 pF. Sinking or sourcing 12 mA for VDD = 3.3 V, 6 mA for VDD = 2.5 V, 3 mA for VDD = 1.8 V. 4 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si597 Table 5. CLK± Output Phase Jitter Parameter Phase Jitter (RMS)1,2 for FOUT of 50 MHz < FOUT < 810 MHz Symbol J Test Condition Min Typ Max Unit Kv = 45 ppm/V 12 kHz to 20 MHz — 0.5 — ps Kv = 95 ppm/V 12 kHz to 20 MHz — 0.5 — ps Kv = 125 ppm/V 12 kHz to 20 MHz — 0.5 — ps Kv = 185 ppm/V 12 kHz to 20 MHz — 0.5 — ps Kv = 380 ppm/V 12 kHz to 20 MHz — 0.7 — ps Notes: 1. Differential Modes: LVPECL/LVDS/CML. Refer to AN256 and AN266 for further information. 2. For best jitter and phase noise performance, always choose the smallest KV that meets the application’s minimum APR requirements. See “AN266: VCXO Tuning Slope (KV), Stability, and Absolute Pull Range (APR)” for more information. Table 6. CLK± Output Period Jitter Parameter Period Jitter* Symbol Test Condition Min Typ Max Unit JPER RMS — 3 — ps Peak-to-Peak — 35 — ps *Note: Any output mode, including CMOS, LVPECL, LVDS, CML. N = 1000 cycles. Refer to AN279 for further information. Table 7. CLK± Output Phase Noise (Typical) Offset Frequency 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 20 MHz 74.25 MHz 148.5 MHz 155.52 MHz 185 ppm/V 185 ppm/V 95 ppm/V LVPECL LVPECL LVPECL –77 –101 –121 –134 –149 –151 –150 –68 –95 –116 –128 –144 –147 –148 –77 –101 –119 –127 –144 –147 –148 Unit dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 5 Si5 97 Table 8. Environmental Compliance and Package Information Parameter Conditions/Test Method Mechanical Shock MIL-STD-883, Method 2002 Mechanical Vibration MIL-STD-883, Method 2007 Solderability MIL-STD-883, Method 2003 Gross and Fine Leak MIL-STD-883, Method 1014 Resistance to Solder Heat MIL-STD-883, Method 2036 Moisture Sensitivity Level J-STD-020, MSL1 Contact Pads Gold over Nickel Table 9. Thermal Characteristics (Typical values TA = 25 ºC, VDD = 3.3 V) Parameter Symbol Test Condition Min Typ Max Unit Thermal Resistance Junction to Ambient JA Still Air — 84.6 — °C/W Thermal Resistance Junction to Case JC Still Air — 38.8 — °C/W Ambient Temperature TA –40 — 85 °C Junction Temperature TJ — — 125 °C Table 10. Absolute Maximum Ratings1 Parameter Symbol Rating Unit TAMAX 85 ºC Supply Voltage, 1.8 V Option VDD –0.5 to +1.9 V Supply Voltage, 2.5/3.3 V Option VDD –0.5 to +3.8 V Input Voltage (any input pin) VI –0.5 to VDD + 0.3 V Storage Temperature TS –55 to +125 ºC ESD 2000 V TPEAK 260 ºC tP 20–40 seconds Maximum Operating Temperature ESD Sensitivity (HBM, per JESD22-A114) Soldering Temperature (Pb-free profile)2 Soldering Temperature Time @ TPEAK (Pb-free profile)2 Notes: 1. Stresses beyond those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation or specification compliance is not implied at these conditions. Exposure to maximum rating conditions for extended periods may affect device reliability. 2. The device is compliant with JEDEC J-STD-020C. Refer to Si5xx Packaging FAQ available at https://www.skyworksinc.com/Product_Certificate.aspx for further information, including soldering profiles. 6 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si597 2. Pin Descriptions (Top View) FS[1] 7 VC 1 6 V DD OE 2 5 CLK– GND 3 4 CLK+ 8 FS[0] Table 11. Si597 Pin Descriptions Pin Name Type Function 1 VC Analog Input Control Voltage 2 OE* Input Output Enable 3 GND Ground Electrical and Case Ground 4 CLK+ Output Oscillator Output 5 CLK– (N/C for CMOS) Output Complementary Output (N/C for CMOS, do not make external connection) 6 VDD Power Power Supply Voltage 7 FS[1] Input Frequency select. Internal 17 kpull-up to VDD. 8 FS[0] Input Frequency select. Internal 17 kpull-up to VDD. *Note: OE pin includes a 17 k resistor to VDD for OE active high option or 17 k to GND for OE active low option. See 3. "Ordering Information" on page 8. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 7 Si5 97 3. Ordering Information The Si597 supports a variety of options including frequency, temperature stability, tuning slope, output format, and VDD. Specific device configurations are programmed into the Si597 at time of shipment. Configurations are specified using the Part Number Configuration chart shown below. Skyworks Solutions provides a web browser-based part number configuration utility to simplify this process. Refer to https://www.skyworksinc.com/en/Products/Timing to access this tool and for further ordering instructions. The Si597 VCXO series is supplied in an industry-standard, RoHS compliant, lead-free, 8-pad, 5 x 7 mm package. Tape and reel packaging is an ordering option. 597 X X XXXXXX D G R R = Tape and Reel Blank = Coil Tape 597 Quad VCXO Product Family Operating Temp Range(°C) G –40 to +85 °C Device Revision Letter 6-digit Frequency Designator Code Four unique frequencies can be specified within the following frequency range: 10 to 810 MHz. A six digit code will be assigned for the specified combination of frequencies. Codes > 000100 refer to VCXOs programmed with the lowest frequency value selected when FS[1:0] = 00, and the highest value when FS[1:0] = 11. Six digit codes < 000100 refer to VCXOs programmed with the highest frequency value selected when FS[1:0] = 00, and the lowest value when FS[1:0] = 11. 1st Option Code A B C D E F G H J K M N P Q R S T U V W VDD 3.3 3.3 3.3 3.3 2.5 2.5 2.5 2.5 1.8 1.8 3.3 3.3 3.3 3.3 2.5 2.5 2.5 2.5 1.8 1.8 Output Format Output Enable Polarity LVPECL High LVDS High CMOS High CML High LVPECL High LVDS High CMOS High CML High CMOS High CML High LVPECL Low LVDS Low CMOS Low CML Low LVPECL Low LVDS Low CMOS Low CML Low CMOS Low CML Low Note: CMOS available to 160 MHz. 2nd Option Code Code A B C D E F G H Temperature Stability ± ppm (max) 20 20 50 20 20 50 50 20 Tuning Slope Kv ppm/V (typ) 380 185 185 125 95 125 95 45 3.3 V 370 160 130 100 65 70 35 15 Minimum APR (±ppm) for VDD @ 2.5 V 1.8 V 275 200 110 80 80 50 75 40 50 25 45 10 20 N/A N/A N/A Notes: 1. For best jitter and phase noise performance , always choose the smallest Kv that meets the application’s minimum APR requirements. Lower Kv options minimize noise coupling and jitter in real-world PLL designs. See AN266 for more information. 2. APR is the ability of a VCXO to track a signal over the product lifetime . A VCXO with an APR of ±100 ppm is able to lock to a clock with a ±100 ppm stability over 15 years over all operating conditions. 3. Nominal Pull range (±) = 0.5 x VDD x tuning slope. 4. Minimum APR values noted above include worst case values for all parameters . Figure 1. Part Number Convention 8 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si597 4. Outline Diagram and Suggested Pad Layout Figure 2 illustrates the package details for the Si598/Si599. Table 12 lists the values for the dimensions shown in the illustration.   Figure 2. Si597 Outline Diagram Table 12. Package Diagram Dimensions (mm) Dimension A b b1 c c1 D D1 e E E1 H L L1 p R aaa bbb ccc ddd eee Min 1.50 1.30 0.90 0.50 0.30 4.30 6.10 0.55 1.17 1.07 1.80 — — — — — Nom 1.65 1.40 1.00 0.60 — 5.00 BSC 4.40 2.54 BSC 7.00 BSC 6.20 0.65 1.27 1.17 — 0.70 REF — — — — — Max 1.80 1.50 1.10 0.70 0.60 4.50 6.30 0.75 1.37 1.27 2.60 0.15 0.15 0.10 0.10 0.05 Note: 1. All dimensions shown are in millimeters (mm) unless otherwise noted. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1994. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 9 Si5 97 5. 8-Pin PCB Land Pattern Figure 3 illustrates the 8-pin PCB land pattern for the Si597. Table 13 lists the values for the dimensions shown in the illustration. Figure 3. Si597 PCB Land Pattern Table 13. PCB Land Pattern Dimensions (mm) Dimension D2 D3 e E2 GD GE VD VE X1 X2 Y1 Y2 ZD ZE Min Max 5.08 REF 5.705 REF 2.54 BSC 4.20 REF 0.84 2.00 — — 8.20 REF 7.30 REF 1.70 TYP 1.545 TYP 2.15 REF 1.3 REF — — 6.78 6.30 Note: 1. Dimensioning and tolerancing per the ANSI Y14.5M-1994 specification. 2. Land pattern design follows IPC-7351 guidelines. 3. All dimensions shown are at maximum material condition (MMC). 4. Controlling dimension is in millimeters (mm). 10 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si597 6. Si597 Mark Specification Figure 4 illustrates the mark specification for the Si597. Table 14 lists the line information. Figure 4. Mark Specification Table 14. Si5xx Top Mark Description Line Position 1 1–10 Part Family Number, 597 (first three characters in part number) 2 1–10 Si597: Option1+Option2+Freq(6)+Temp 3 Description Trace Code Position 1 Pin 1 orientation mark (dot) Position 2 Product Revision (D) Position 3–6 Position 7 Tiny Trace Code (four alphanumeric characters per assembly release instructions) Year (least significant year digit), to be assigned by assembly site (ex: 2009 = 9) Position 8–9 Calendar Work Week number (1–53), to be assigned by assembly site Position 10 “+” to indicate Pb-Free and RoHS-compliant Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 11 Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 Si5 97 REVISION HISTORY Revision 1.1 June, 2018  Changed “Trays” to “Coil Tape” in 3. "Ordering Information" on page 8. Revision 1.0          12 Changed frequency range to 10 to 810 MHz. Changed output frequencies in Description section on page 1. Updated functional block diagram on page 1. Corrected the mechanical drawing’s pinout to match the device on page 1. Deleted frequency information from Note 2 in Table 3 on page 3. Changed CML output option table specs in Table 4 on page 3. Added Table 9 on page 6. Updated Figure 2 on page 9. Corrected marking information in Figure 4 on page 11. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • March 5, 2022 ClockBuilder Pro One-click access to Timing tools, documentation, software, source code libraries & more. Available for Windows and iOS (CBGo only). skyworksinc.com/CBPro Portfolio SW/HW Quality Support & Resources skyworksinc.com skyworksinc.com/CBPro skyworksinc.com/quality skyworksinc.com/support Copyright © 2022 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks’ Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NONINFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of Skyworks’ published specifications or parameters. Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540
597PF000189DGR 价格&库存

很抱歉,暂时无法提供与“597PF000189DGR”相匹配的价格&库存,您可以联系我们找货

免费人工找货