BAC05S05DC

BAC05S05DC

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    DIP5 模块

  • 描述:

    封闭式 AC DC 转换器 1 输出 5V 1A 85 ~ 264 VAC,120 ~ 370 VDC 输入

  • 数据手册
  • 价格&库存
BAC05S05DC 数据手册
BAC05 Series www.murata.com Isolated 5W Regulated Single Output AC/DC Converters FEATURES n UL62368-1 recognised n EN62368-1 certified n IEC61558-1 & IEC61558-2-16 certified n ANSI/AAMI ES60601-1, 1 MOPP/2 MOOP recognition pending n Wide input voltage range 85-264VAC/ 120-370VDC A 5 5 5 5 12 24 1 0.42 0.21 With high efficiency at low loads and low no load power consumption, the BAC05 supports standby mode operation for applications in industrial, medical, automation, IOT as well as household and home automation. 50 120 200 35 65 120 Isolation Capacitance % 50 120 200 72 76 78 75.5 79 81 kHrs 72 76 78 76 79 80.5 45 45 45 882 8793 866 12571 1144 16698 Min. Typ. Max. Units Voltage range 85 120 47 115/230 264 370 63 VAC VDC Hz kHz Input frequency Switching frequency Input current No load power consumption n Primary side regulation The BAC05 series delivers an output power of 5 watts from -40°C to 55°C, operating up to 85°C with derating, from AC or DC input voltages. The BAC05 series small footprint is EMC class B compliant without the need of any external components. The BAC05 series is suited to medical applications with 1 MOPP and 2 MOOP. 35 65 110 pF Conditions Input leakage current PRODUCT OVERVIEW Typ. Max. Typ. Max. Min. Typ. Min. Typ. All input types All input types n 5V, 12V & 24V single regulated outputs n No external components required 230V Telcordia V 115V MIL 217 W 230V MTTF1 Parameter Inrush current n Meets EMC class B with no external components Output Current  115V Efficiency INPUT CHARACTERISTICS n 4.7kVDC isolation ‘Hi Pot Test’ n Short circuit protection Ripple & Noise mVp-p BAC05S05DC BAC05S12DC BAC05S24DC n Operating temperature range –40°C to 85°C n Over current protection Output Voltage Order Code Output Power SELECTION GUIDE Nominal Vin = 115VAC Nominal Vin = 230VAC Nominal Vin = 115VAC Nominal Vin = 230VAC 250VAC 115V BAC05S05DC 230V 115V BAC05S12DC 230V 115V BAC05S24DC 230V 50/60 64 100 60 11 23 25 45 88 45 129 65 129 mA A µA mW ISOLATION CHARACTERISTICS Parameter Isolation test voltage Resistance Safety standard UL62368-1 EN62368-1 ANSI/AAMI ES60601-12 Conditions Min. Production tested for 1 second Qualification tested for 1 minute Viso = 1000VDC 4700 4700 100 Reinforced 1 MOPP & 2 MOOP Typ. Max. Units VDC MΩ 240 240 Creepage and clearance 8.4mm Vrms 240 TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Operation Storage Convection cooling 0.2m/s -40 -40 Product temperature rise above ambient BAC05S05DC BAC05S12DC BAC05S24DC Typ. Max. Units 85 85 33 27 26 °C 1. Calculated using MIL-HDBK-217F and Telcordia SR-332 calculation model at TA=25°C with nominal input voltage 115VAC at full load. 2. ANSI/AAMI ES60601-1 recognition is currently pending. For full details go to https://www.murata.com/englobal/products/power/rohs All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata.com KAC_BAC05C.C01  Page 1 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters OUTPUT CHARACTERISTICS Parameter Conditions Minimum load Initial voltage accuracy All output types Line regulation Low line to high line Min. 115VAC Load regulation Typ. Max. ±0.06 ±0.01 ±0.08 ±0.4 ±0.1 ±0.4 ±0.15 ±0.1 ±4 ±0.5 ±0.5 ±0.5 ±1 ±1 ±1 ±1 ±1 0.05 10 10% total load to 100% total load 230VAC BAC05S05DC BAC05S12DC BAC05S24DC BAC05S05DC All others BAC05S05DC BAC05S12DC BAC05S24DC Temperature coefficient Peak deviation - 50-75% & 75-50% swing Transient response Current limit inception Hold up time Settling time (within 5% Vout Nom.) BAC05S24DC All others BAC05S12DC All others 115VAC 230VAC ±2 3.5 2 110 120 15 75 Units % % % % %/°C %Vout ms % ms ABSOLUTE MAXIMUM RATINGS Short-circuit protection Input voltage Continuous, automatic recovery 277VAC Lead temperature 1.0mm from case for 7 +2/-0 seconds (to JEDEC JESD22-B106) 270±5°C Shelf life (1 year) Wave Solder Please refer to reconditioning application notes. Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. www.murata.com KAC_BAC05C.C01  Page 2 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions BAC05 series of AC/DC converters are all 100% production tested at their stated isolation voltage. This is 4.7kVDC for 1 second. The BAC05 has been recognised by Underwriters Laboratory to 240Vrms for Reinforced Insulation. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The BAC05 series is pending recognition by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 240Vrms max., between Primary and Secondary. EN62368-1 The BAC05 series has been certified by Demko (D) to EN62368 for reinforced insulation to a working voltage of 240Vrms. File number D-07177 applies. UL62368 The BAC05 series has been recognised by Underwriters Laboratory (UL) to UL62368 for reinforced insulation to a working voltage of 240Vrms. File number E151252 applies. Creepage and clearance 8.4mm Working altitude OVC II 5000m IEC61558-1 & IEC61558-2-16 The BAC05 series has been certified by TUV SUD to IEC61558-1 & IEC61558-2-16. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds based on IEC 61760-1. Please refer to application notes for further information. The pin termination finish on this product series is Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata.com/en-global/ products/rohs www.murata.com KAC_BAC05C.C01  Page 3 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters ENVIRONMENTAL VALIDATION TESTING The following tests have been conducted on this product series, as part of our design verification process. The datasheet characteristics specify user operating conditions for this series, please contact Murata if further information about the tests is required. Test Standard Condition Temperature cycling Humidity bias Storage life JEDEC JESD22-A104 JEDEC JESD22-A101 JEDEC JESD22-A103 200 cycles. -40°C to 105°C, 15 minutes hold at each extreme including transitions. 85°C ±2°C, 85±5% R.H. for 1000 (+168/-24) hours 105°C +10/-0°C for ≥1000 hours Vibration BS EN 61373 with respect to BS EN 5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest 60068-2-64, Test Fh Category 1 Class B factor: 3 Sigma. Device is secured via the pins. Shock BS EN 61373: Category 1 Class B Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axes (18 shocks total). Level at each axis as follows: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via pins. Solderability EIA/IPC/JEDEC J-STD-002, Test A1 Parts are baked for 4 hours at a temperature of 155°C, within 72 hours they are dipped in flux for 10 seconds. Followed by dipping the parts in a solder pot at 255°C ±5°C for 5 seconds (96SC tin/silver/copper) Solder Heat JEDEC JESD22-B106 The test sample is subjected to a molten solder bath at 270°C ±5°C for 7 +2/-0 seconds (96SC tin/silver/ copper). The leads are dipped in the solder bath to within 1mm of the device body. Solder Heat (Hand) Solvent cleaning MIL-STD-202 Method 210, Condition A Resistance to cleaning agents The soldering iron is heated to 350°C ± 10°C and applied to the terminations for a duration of 4 to 5 seconds. Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C- 65°C Solvent Resistance MIL-STD-883 Method 2015 The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The parts are brushed 3 times, after the third time the parts are blown dry and inspected. Lead Integrity (Adhesion) MIL-STD-883 Method 2025 Leads are bent through 90º until a fracture occurs. Lead Integrity (Fatigue) MIL-STD-883 Method 2004, Condition B1 The leads are bent to an angle of 15º. Each lead is subjected to 3 cycles. Lead Integrity (Tension/ Pull) MIL-STD-883 Method 2004, Condition A1 Pull of 0.227kg applied for 30 seconds. The force is then increased until the pins snap. EMC/ESD STANDARDS Conducted emissions Radiated emissions ESD immunity EN55032/FCC class B EN55032/FCC class B IEC/EN 61000-4-2, Level 1, criteria A Radiated, radio-frequency, electromagnetic field immunity IEC/EN61000-4-3, 10V/m perf criteria A 10V/m 80-1000MHz 3V/m 1.4-2.0GHz 1V/m 2.0-2.7GHz All 80% 1kHz am mod all perf criteria A EFT/burst Surge immunity Conducted field immunity Power frequency magnetic field immunity Harmonic current emissions Voltage changes, voltage fluctuations and flicker Voltage dips, short interruptions and variations IEC/EN61000-4-4, 2kV, perf criteria A IEC/EN61000-4-5, 1kV perf criteria A IEC/EN61000-4-6, 10 Vrms 0.15-80MHz 80% 1kHz am mod perf criteria A IEC/EN61000-4-8, 50Hz/60Hz 30 A/m perf criteria A IEC/EN61000-3-2 IEC/EN61000-3-3 IEC/EN61000-4-11, 100% for 20ms, 60% for 200ms, 30% for 500ms and 100% for 5s perf criteria A-A-A-C. www.murata.com KAC_BAC05C.C01  Page 4 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters PART NUMBER STRUCTURE BAC 05 S XX D C Series name RoHS compliant Power rating Package type S - SIP D - DIP M - Surface mount Z - ZIP Output type S - Single D - Dual Output voltage CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 10µF electrolytic capacitor Differential Mode Noise Test Schematic Oscilloscope 3 Load -Vout 4 2 5 1 + 10μF +Vout Twisted wire: #20AWG-30cm APPLICATION NOTES Output Capacitance and start-up times The BAC05 series does not require output capacitors to meet datasheet specification. To meet datasheet specification, output capacitance should not exceed: Part No. BAC05S05DC BAC05S12DC BAC05S24DC Maximum Load Capacitance Load capacitance to meet start-up Start-up times with maximum load capacitance Start up times with 10μF μF 1000 330 220 μF 10 10 10 ms 340 630 1900 ms 140 210 430 When operational in an application will operate down to -40°C . For start-up below nominal input voltage ≤115VAC, at very low temperatures, please refer the temperature derating graphs. www.murata.com KAC_BAC05C.C01  Page 5 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters APPLICATION NOTES (Continued) Minimum Load The minimum load to meet full datasheet specification is 10% of the full rated load across the specified input voltage range. Reconditioning This series contains electrolytic capacitors, which require reconditioning if the product is stored non-powered for more than 2 years from the date of manufacture. To recondition the capacitors, an AC input voltage should be applied with output loading for 10 minutes. For further information please contact Murata. EFFICIENCY VS LOAD BAC05S05DC BAC05S12DC 90.00 90.00 80.00 80.00 70.00 70.00 60.00 50.00 85V 115V 40.00 230V 264V 30.00 Efficiency (%) Efficiency (%) 60.00 50.00 20.00 10.00 10.00 0 20 40 60 80 100 0.00 120 Load (%) 115V 230V 264V 30.00 20.00 0.00 85V 40.00 0 20 40 60 80 100 120 Load (%) BAC05S24DC 90.00 80.00 70.00 Efficiency (%) 60.00 50.00 85V 115V 40.00 230V 264V 30.00 20.00 10.00 0.00 0 20 40 60 80 100 120 Load (%) www.murata.com KAC_BAC05C.C01  Page 6 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters TEMPERATURE DERATING - PART OPERATIONAL BAC05S05DC BAC05S12DC 100% 100% 90% 90% 80% 80% 70% 70% 60% 85VAC 50% 115VAC 230VAC 40% Load (%) Load (%) 60% 115VAC 230VAC 40% 264VAC 264VAC 30% 30% 20% 20% 10% 10% 0% 85VAC 50% 0% -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Temperature (°C) Temperature (°C) BAC05S24DC 100% 90% 80% 70% Load (%) 60% 85VAC 50% 115VAC 230VAC 40% 264VAC 30% 20% 10% 0% -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Temperature (°C) www.murata.com KAC_BAC05C.C01  Page 7 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters TEMPERATURE DERATING - COLD STARTUP BAC05S05DC BAC05S12DC 100% 100% 90% 90% 80% 80% 70% 70% 60% 85VAC 50% 115VAC 230VAC 40% 264VAC Load (%) Load (%) 60% 30% 20% 20% 10% 10% -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 0% 100 Temperature (°C) 115VAC 230VAC 40% 30% 0% 85VAC 50% 264VAC -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Temperature (°C) BAC05S24DC 100% 90% 80% 70% Load (%) 60% 85VAC 50% 115VAC 230VAC 40% 264VAC 30% 20% 10% 0% -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Temperature (°C) www.murata.com KAC_BAC05C.C01  Page 8 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS All dimensions in mm Unless otherwise specified all pins within ±0.30 of true position. Function 1 AC(N) 2 AC(L) 3 NC 4 -Vout 5 +Vout Weight: 18g TUBE OUTLINE DIMENSIONS Unless otherwise specified all dimensions in mm. Tube Length : 550mm±2.0. Pin RECOMMENDED FOOTPRINT DETAILS Tube Quantity : 20 The isolation barrier shown must not have any copper traces even on internal layers. This is to avoid compromising the creepage and clearance distance. PCB layouts must take into consideration the required clearance and creepage requirements to maintain the clearance and creepage of the isolation barrier. All dimensions in mm. www.murata.com KAC_BAC05C.C01  Page 9 of 10 BAC05 Series Isolated 5W Regulated Single Output AC/DC Converters DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to: • Aircraft equipment • Aerospace equipment • Undersea equipment • Power plant control equipment • Medical equipment • Transportation equipment ( automobiles, trains, ships, etc.) • Traffic signal equipment • Disaster prevention / crime prevention equipment • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2023 Murata Power Solutions (Milton Keynes) Ltd. www.murata.com KAC_BAC05C.C01  Page 10 of 10
BAC05S05DC 价格&库存

很抱歉,暂时无法提供与“BAC05S05DC”相匹配的价格&库存,您可以联系我们找货

免费人工找货