Dual Output BWR Models
www.murata-ps.com
Mixed Voltage, 5V AND 3.3V, 2” x 2”
33 Watt DC/DC Converters
Typical units
FEATURES
PRODUCT OVERVIEW
Regulated 3.3V and 5V outputs
5V @ 6Amps/3.3V @ 7 Amps capability
For applications requiring 33 watts of power from
5V and 3.3V, DATEL offers a new power sharing
DC/DC converter capable of meeting your output
current requirements. The BWR-5/6-3.3/7-D48
(36-75V input), BWR-5/6-3.3/7-D24 (18-36V
input) and BWR-5/6-3.3/7-D12 (10-18V input)
are fully isolated DC/DC converters capable of
delivering any combination of 5V and 3.3V loading up to a combined total of 33 Watts of output
power.
Housed in a standard 2" x 2" x 0.45" metal
package coated with electrically non-conductive
finish, these converters utilize a shared controlloop system to assure load regulation of ±1% for
3.3V output and ±1.5% for 5V output. All models
include input Pi filtering, input overvoltage and
33 Watts total output power
No-load operation
Available input voltage ranges:
10-18V, 18-36V or 36-75V
Small 2" x 2" x 0.45" package
UL1950 and EN60950-1 safety approvals
mark available (75V-input models)
Continuous short-circuit protection
Fully isolated, 1500Vdc guaranteed
–40 to +100°C operating temperature
Input under and overvoltage shutdown
undervoltage shutdown circuitry, output overvoltage protection, output short-circuit and current
limiting protection, and thermal shutdown.
Each design also provides trim capability and
on/off control function. Fully synchronous output
rectification renders high efficiency and no-load
operation.
BWR power sharing modules offer low ripple
and noise performance, high efficiency (88%),
1500Vdc of isolation voltage, and are fully
specified for –40 to +100°C operation. These
devices meet IEC950, UL1950 and EN6950 safety
standards, including BASIC insulation requirements for “D48” models. CB reports are available
on request. “D48” models are CE marked (meet
LVD requirements).
Output overvoltage protection
Thermal shutdowns
+5V OUTPUT
(5)
+INPUT
(1)
SWITCH
CONTROL
+3.3V OUTPUT
(7)
–INPUT
(2)
ON/OFF
CONTROL
(4)
OUTPUT
RETURN
(6)
PWM
CONTROLLER
ACTIVE
BLEEDER
OPTO
ISOLATION
UV & OV
COMPARATORS
REFERENCE &
ERROR AMP
THERMAL
SHUTDOWN
TRIM
(8)
Typical topology is shown.
Figure 1. Simplified Schematic
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_BWR 33W Models.A06 Page 1 of 12
Dual Output BWR Models
Mixed Voltage, 5V AND 3.3V, 2” x 2”
33 Watt DC/DC Converters
Performance Specifications and Ordering Guide ➀
ORDERING GUIDE SUMMARY
Output
Models
VOUT
(Volts)
IOUT ➁
(Amps)
5
3.3
5
3.3
5
3.3
6
7
6
7
6
7
BWR-5/6-3.3/7-D12
BWR-5/6-3.3/7-D24
BWR-5/6-3.3/7-D48
➀
➁
➂
➃
Input
R/N (mVp-p) ➂
Typ.
Max.
40
95
40
95
40
95
Regulation (Max.) ➆
VIN Nom.
Line
Load ➃ No Load ➅ (Volts)
100
140
100
140
100
140
±1%
±0.5%
±1%
±0.5%
±1%
±0.5%
±1.5%
±1%
±1.5%
±1%
±1.5%
±1%
Typical at TA = +25°C under nominal line voltage and balanced “full-load” conditions (5V @ 3.3A/3.3V @ 5A).
Any combination of 5V/3.3V rated IOUT current, not to exceed 33 Watts of output power. (See derating graphs.)
Ripple/Noise (R/N) measured over a 20MHz bandwidth. All models are specified with 1µF ceramic output capacitors.
Tested from 10% load to 100% load (other output at 10% load).
±2.5%
±1.5%
±2.5%
±1.5%
±2.5%
±1.5%
Efficiency
Min.
Typ.
Package
(Case,
Pinout)
Range
(Volts)
IIN ➄
(mA)
12
10-18
70/3308
83%
86%
C4,P33
24
18-36
50/1615
85%
88%
C4,P33
48
36-75
25/780
85%
88%
C4,P33
➄ Nominal line voltage, no load/balanced full-power condition.
➅ Tested from no-load to 100% load (other output at no-load).
➆ Output trim may impact 5V load regulation.
*LAST TIME BUY: 4/1/2018. CLICK HERE FOR DISCONTINUANCE NOTICES.
PART NUMBER STRUCTURE
Optional Functions
BWR 33 Watt DC/DC’s are designed with an On/Off Control
function with positive polarity in the pin 4 position.
BWR - 5 / 6 - 3.3 / 7 - D48 LX - C
Dual Output/
Mixed-Voltage Series
RoHS-6 Compliance*
V1 Nominal Output Voltage:
5 Volts
L1
L2
Pin length: 0.110 in. (2.79mm) ±0.010
Pin length: 0.145 in. (3.68mm) ±0.010
Optional Functions
Pin length options require a minimum order quantity.
Input Voltage Range:
D12 = 10-18 Volts (12V nominal)
D24 = 18-36 Volts (24V nominal)
D48 = 36-75 Volts (48V nominal)
I1 Maximum Output Current:
6 Amps
Refer to the last page for additional options.
* Contact MPS for availability.
V2 Nominal Output Voltage:
3.3 Volts
I2 Maximum Output Current:
7 Amps
MECHANICAL SPECIFICATIONS
2.00
(50.80)
0.45
(11.43)
METAL CASE
C04
MetalC4
Case
Case
INSULATED BASE
0.040 ±0.002 DIA
(1.016 ±0.051)
0.20 MIN
(5.08)
1.800
(45.72)
0.10
(2.54)
5
0.200
(5.08)
6
1
2
7
0.400
(10.16)
4
1.200
(30.48)
3 EQ. SP. @
0.400 (10.16)
I/O Connections
Pin Function P33
1
+Input
2
–Input
3
No Pin
4
On/Off Control
5
+5V Output
6
Output Return
7
+3.3V Output
8
Trim
Notes:
For “D12” and “D24” models the
case is connected to pin 2 (–Input).
For “D48” models, the case is
connected to pin 1 (+Input).
2.00
(50.80)
8
0.40
(10.16)
0.100
(2.54)
BOTTOM VIEW
Dimensions in inches (mm)
www.murata-ps.com/support
MDC_BWR 33W Models.A06 Page 2 of 12
Dual Output BWR Models
Mixed Voltage, 5V AND 3.3V, 2” x 2”
33 Watt DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage, balanced "full-load" conditions, unless noted. ➀
Output (continued)
Input
Input Voltage Range:
D12 Models
D24 Models
D48 Models
10-18 Volts (12V nominal)
18-36 Volts (24V nominal)
36-75 Volts (48V nominal)
Overvoltage Shutdown: ➁
D12 Models
D24 Models
D48 Models
19-23 Volts (21V nominal)
37-42 Volts (40V nominal)
77-81 Volts (79V nominal)
Start-Up Threshold: ➁
D12 Models
D24 Models
D48 Models
9-10 Volts (9.3V nominal)
16.5-18 Volts (17V nominal)
34-36 Volts (35V nominal)
Undervoltage Shutdown: ➁
D12 Models
D24 Models
D48 Models
Input Current:
Normal Operating Conditions
Standby Mode:
Off, OV, UV, Thermal Shutdown
Short Circuit Current: ➁
5V Output
3.3V Output
5 Amps average, continuous
6 Amps average, continuous
Overvoltage Protection: ➁
5V Output
3.3V Output
Magnetic feedback
6.8 volts
4.5Volts
Maximum Capacitive Loading
D12 Models
3.3V
5V
D24, D48 Models 3.3V
5V
1000µF
470µF
2000µF
1000µF
Dynamic Characteristics
8.5-9.6 Volts (9.3V nominal)
16-17 Volts (16.5V nominal)
32.5-35 Volts (34V nominal)
Dynamic Load Response ➁
5V (50-100% load step to 4% VOUT)
300µsec maximum
3.3V (50-100% load step to 2.5% VOUT) 300µsec maximum
See Ordering Guide
Start-Up Time ➁
VIN to VOUT
On/Off to VOUT
20msec maximum
15msec maximum
285kHz (±15kHz)
10mA typical
Switching Frequency
Input Reflected Ripple Current:
Source Impedance
D12 Models
D24/D48 Models