DMR20-1-FM-R-C

DMR20-1-FM-R-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    -

  • 描述:

    FREQUENCYMETER85-264VLED

  • 数据手册
  • 价格&库存
DMR20-1-FM-R-C 数据手册
www.murata-ps.com DMR20-1-FM NANO Self-Powered, LED Display, AC Line Frequency Monitor FEATURES  Self-powered from 85 to 264Vac / 45-65Hz supplies  0.01Hz resolution & quartz crystal accuracy and stability  Installs in “oiltight” 1.20 inch (30.5mm) round cutouts  Four-digit LED display with out-of-range indication  Digital replacement for analog panel meters  Self-resetting internal fuse for long-term reliability  Supplied with EPDM rubber gasket and plastic hex nut E156931  Provides moisture ingress protection to IP67/NEMA 6  Screw-style input terminal block simplifies installation  Knockout punches and tooling available  Approvals to UL/cUL/IEC/ 61010-1 Performance/Functional Specifications Typical at Ta = +25°C, Vin = 250Vac / 60Hz sine wave, unless otherwise noted AC Input (TB1) Voltage Range ➀ Current Consumption UL/IEC61010-1 85 to 264Vac (45-65 Hz) 250Vac/60Hz: 12mA (max.) Measurement Category II Performance Sampling Rate Resolution Accuracy @ +25°C Temperature Drift 2-3 readings/second 0.01Hz ±0.01Hz (typ.), ±0.02Hz (max.) ±0.0005Hz/°C (–25 to +60°C) Mechanical Dimensions 1.5" diameter x 1.1” depth (38 x 28mm) Display Type Four digit, LED, 0.30” high (7.6mm) Weight 0.9 ounces (25.5 grams) Case Material Polycarbonate Terminal Block Torque 2.2 lb·in (0.25 N·m) ±20% Wire Size And Type 18-22AWG (0.83-0.33mm2) copper, solid or stranded Wire Insulation Strip Length 0.25" (6.4mm) Environmental Operating Temperature –25 to +60°C Storage Temperature –40 to +75°C Humidity (non-condensing) 0 to 85% Murata Power Solutions’ new DMR20-1-FM is the world’s smallest, self-powered, ac line frequency monitor. Simply connect 85 to 264Vac (45-65Hz) power and the meter is fully operational—no additional components are required. The unit can also measure distorted 120Vrms power sources with triangle and square waveforms, as well as quasi sine wave outputs of dc to ac power inverters. An ultra-stable, quartz-crystal controlled microprocessor provides accuracies of ±0.02Hz over the operating temperature range of -25 to +60°C. DMR20-1-FM frequency monitors feature a large, 0.30”/7.6mm, bright LED display that can be easily read from 10 feet away (3 meters). A built-in resettable fuse and out-of-range indication assures long term reliability. The DMR20-1-FM is housed in a rugged, round polycarbonate case that provides excellent protection against moisture, dust, shock and vibration. Panel installation is straightforward: using available tooling, simply drill and punch a 1.2 inch (30.5mm) diameter hole and anti-rotation notch, insert the meter and gasket, and securely fasten the meter using the supplied hex nut. The nut and gasket are designed to provide moisture ingress protection to IP67/NEMA 6. DMR20-1-FM is exactly the same size as Murata Power Solutions’ DMR20-1-ACV (ac volts), DMR20-10-DCM (dc volts), and DMR20-1-TMP (temperature) digital panel meters. Ordering Information DMR20-1-FM-R-C 85 to 264Vac frequency monitor (Red LED) Knockout Punches DMR20-1-KP DMR20-2-KP DMR20-3-KP 1.2" (30.5mm) Round knockout punch (no keying notch) 1.2" (30.5mm) Round knockout punch (with four keying notches) 1/8" and 3/16" (3.2 and 4.7mm) key-notch nibbler tool Note: An M30 x 1.5 nylon hex nut and EPDM sealing gasket are supplied with each meter. The “-C” suffix denotes RoHS compliance. ➀ Operation and accuracy with ac inputs above or below this range are not specified. Operation from waveforms other than sine waves is limited to 120Vrms. See Technical Note 1 for additional information.   For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MPM_DMR20-1-FM.A02 Page 1 of 3 NANO TECHNICAL NOTES ! IMPORTANT! To ensure safe and reliable operation, DMR20-1-FM ac frequency monitors must be installed and serviced by qualified technical personnel. Contact Murata Power Solutions if there is any doubt regarding their installation or operation. 1. Measurement Type: DMR20-1-FM meters are designed to be powered from sine wave ac supplies, over their rated input of 85-264Vac (4565Hz). Operation from triangle, square, and quasi-sine waveforms is limited to a maximum of 85 to 120rms (45-65Hz). 2. Calibration: DMR20-1-FM frequency monitors are factory calibrated; there are no provisions for calibrating these meters in the field. 3. Operating Range: As the sine wave ac input voltage is lowered below 100Vac (50 or 60Hz), the DMR20-1-FM’s display may begin to dim slightly, but the readings will remain accurate down to 85Vac. Input frequencies below 45Hz and above 65Hz will display as four dashes, indicating an out-of-range input condition. 4. Panel Installation: All electrical connections to DMR20-1-FM must be made after the meter is securely attached to the panel, and with the input ac supply de-energized (off). In high-vibration environments, adequate strain reliefs must be used on all supply wiring. See Figure 1 for typical panel mounting details. Tightening Torque: The recommended tightening torque for the M30 x 1.5 plastic hex nut is 10 to 17 in-lbs (1.3 to 1.9 N-m). If a torque wrench is not available, this recommended range can be approximated by hand tightening the hex nut SLOWLY until it just bottoms out against the panel’s rear surface. From this bottomed-out reference position, using a suitable tool, tightening the hex nut ¼ turn clockwise will produce approximately 10 in-lbs (1.3 N-m) of torque; tightening it 3/8 turn clockwise will produce approximately 17 in-lbs (1.9 N-m). Check to make sure the housing’s anti-rotation key is aligned with the notches on both the panel and the gasket before tightening the hex nut. Over tightening the hex nut will distort the rubber gasket and may damage the threads on both the nut and the housing, thereby compromising the installation’s mechanical integrity and its ability to protect against environmental effects. DMR20-1-FM Self-Powered, LED Display, AC Line Frequency Monitor Panel Materials: Acceptable panel materials include aluminum, mild steels, plastics, FR-4 pc-board (fiberglass), and many other materials with a flat matte surface on both sides of the cutout. The DMR-20-x-KP tools can be used with most panel materials except stainless steel or other hardened metals. DMR20-1-FM has passed vibration testing combined with temperature cycling while mounted to the materials noted above, using the specified tightening torques. If the meter will be mounted to extremely smooth, slippery surfaces, the user is advised to test the completed assembly under the environmental conditions encountered in the end application. 5. AC Input Fusing and Wiring: DMR20-1-FM frequency monitors contain an internal, self-resettable fuse. However, the supply wires connected to input terminals TB1-A and TB1-B must be fused with an external, user supplied, 0.25A/300V time delay/time lag fuse, in accordance with applicable regulatory codes. All supply wiring must be rated for the voltages and currents they will conduct and comply with any code or application-mandated requirements pertaining to the user’s specific installation. 300V, UL-rated hook-up wire suitable for the intended application is required. TB1 is to be used only for powering the meter’s internal circuitry; it must not be used to supply power to external loads. The recommended TB1 supply wire size is 18AWG to 22AWG (0.83mm2 to 0.33mm2) solid or stranded copper wire. The supply wires must be properly stripped and attached to TB1 such that their insulation is not pinched by the screw terminal. Recommended insulation strip length is 0.25” (6.4mm). When using stranded wire, verify that there are no loose or stray strands that could potentially cause a short circuit across the ac supply input. 6. AC Input Polarity and Grounding: The ac supply inputs TB1-A and TB1-B terminals are not polarity sensitive, that is, neither terminal is designated as “AC LO” or “AC HI.” DMR20-1-FM frequency monitors do not include, nor require, a connection to earth/chassis ground. Panel Thickness: When using both the factory supplied EPDM gasket and hex nut (the recommended standard installation method), the DMR20-1-FM can be mounted in panels ranging from 0.032” to 0.250” (0.8 to 6.4mm) thick. When the gasket is not used, the panel thickness range is 0.075” to 0.325” (1.9 to 8.3mm). However, using the factory supplied hardware and tightening torque recommendations provides optimal resistance to vibration, dust, and moisture ingress. Figure 1. Panel Installation www.murata-ps.com/support MPM_DMR20-1-FM.A02 Page 2 of 3 DMR20-1-FM NANO Self-Powered, LED Display, AC Line Frequency Monitor MECHANICAL SPECIFICATIONS 1.08 (27.4) 0.55 (14) 0.080 (2.03) 1.50 (38.1) 1.18 (29.8) 0.10 (2.5) 0.655 (16.64) FREQUENCY Hz A B TB1 Dimensions are in inches (mm). 0.100 (2.54) 0.062 (1.58) Tolerances (unless otherwise specified): .XX ± 0.02 (0.51) .XXX ± 0.010 (0.254) Angles ± 2˚ Components are shown for reference only. 3D models are available at www.murata-ps.com/en/3d/meters.html 1.210 (30.73) Recommended panel cutout 1. Description of safety marks: Caution, risk of electrical shock Caution, risk of danger 2. Cleaning Instructions: Gently clean with dry cloth only. 3. Caution: if the equipment is used in a manner not specified by Murata Power Solutions, the protection provided by the equipment may be impaired. Equipment is partially protected by double or reinforced insulation Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2016 Murata Power Solutions, Inc. www.murata-ps.com/support MPM_DMR20-1-FM.A02 Page 3 of 3
DMR20-1-FM-R-C 价格&库存

很抱歉,暂时无法提供与“DMR20-1-FM-R-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DMR20-1-FM-R-C
  •  国内价格 香港价格
  • 12+345.4236712+44.72533

库存:0

DMR20-1-FM-R-C
  •  国内价格
  • 1+333.22196

库存:2