DMR35-DCA3-DC1-R

DMR35-DCA3-DC1-R

  • 厂商:

    MURATA-PS(村田)

  • 封装:

  • 描述:

    MURATA - DMR35-DCA3-DC1-R - Panel Meter, DC Current, 3.5 Digit, 5A to 500A, 9 to 32 VDC

  • 详情介绍
  • 数据手册
  • 价格&库存
DMR35-DCA3-DC1-R 数据手册
DMR35-DCA Series Precision DC Shunt Ammeter PRODUCT OVERVIEW The DMR35-DCA series of panel meter performs precision measurements of DC current and is available in two models offering ranges from 1A to 25A . The 3-1/2 digit numeric display supports precision measurement, and a fast-responding 21 segment bargraph tracks quickly-changing measured values. The internal precision shunt resistors simplify the meter’s use and allow for increased accuracy compared with solutions relying on external shunt resistors. Rear-accessible DIP switches are provided for the selection of measurement range and display brightness. The meter is powered from an external 9-32VDC power supply and typically requires only 37 mA when operated at 12V. The measurement inputs provide +/-48V of common-mode input range, simplifying the meter’s use in a wide range of applications. Features              Bright, easily readable LED display Up to 3-1/2 digit measurements Bar-graph display scale 0.8 % measurement accuracy Precision internal shunt resistor Selectable current measurement ranges Unipolar/ Bipolar measurement options User-adjustable display brightness Mechanical drop-in replacement for common analog-movement meters Operates from 9 to 32 VDC Low current consumption, 37 mA typical at 12VDC RoHS Compliant Two year warranty The DMR35 family features a rugged polycarbonate housing that is mountable in a round hole using supplied screws, and is designed as a mechanical drop-in replacement for many commonly available analog movement meters, making it ideal for use in laboratory instrumentation, factory automation, and other applications requiring precise DC current monitoring ORDERING INFORMATION: MODEL NUMBER DESCRIPTION DMR35-DCA1-DC1-R DMR35-DCA2-DC1-R DC Ammeter, 1-5A ranges, 9-32VDC powered, red display DC Ammeter, 10-25A ranges, 9-32VDC powered, red display SIMPLIFIED BLOCK DIAGRAM For full details go to www.murata-ps.com/rohs www.murata-ps.com DMR35-DCA.A01.D04 Page 1 of 8 DMR35-DCA Series Precision DC Shunt Ammeter SPECIFICATIONS: Measurement Performance Measurement Ranges DMR35-DCA1 DMR35-DCA2 Accuracy (25 °C) Min Typ. Max Units 0-1, 0-2, 0-3, 0-5, ±1, ±2, ±3, ±5 0-10, 0-15, 0-20, 0-25, ±10, ±15, ±20, ±25 0.8% of reading + 2 counts 0.01 A A Temperature Stability % F.S. /°C Burden voltage at highest range, full-scale input current (1) DMR35-DCA1 (5 A) 50 mV DMR35-DCA2 (25 A) 50 mV Absolute Maximum Input Current (+I_IN to –I_IN, applied for 1 minute max. ) (2) DMR35-DCA1 -10 10 A DMR35-DCA2 -27 27 A Absolute Maximum voltage differential (either +I_IN -48 +48 V or –I_IN to –VS) (2) Notes: 1) ‘Burden Voltage’ is the voltage drop across the meter when measuring a current. Burden voltage is specified for a given input current – In this case the maximum rated current at the highest measurement range. 2) Exceeding Absolute Maximum ratings may result in permanent damage to the meter. Power Supply Characteristics Operating Supply Voltage Absolute Maximum Supply Voltage Operating Supply Current 12V supply 24V supply Display & User Interface Display Type & Size Min 9 -1 Typ. Max 32 34 Units V V 37 25 3-1/2 digit 7-segment, 11.4mm (0.45 in.) high 21 segment curved bar-graph Red (625nm) Automatic Flashing display Dipswitch selectable (8 ranges) Dipswitch selectable (4 ranges) Small Terminals 14-24 AWG 6mm (0.24 in.) 0.4 N-m (3.5 lb.-in) Display Color Decimal Point Selection Out-of-range Indication Measurement Range Selection Display Intensity Control Terminal Blocks Wire Size Insulation Strip Length Screw Tightening Torque Mechanical/Environmental Parameter Operating Temperature Storage Temperature Humidity (non-condensing) Sealing (front face, when installed with included gasket) Mounting screws (4 included) Screw Tightening Torque Panel thickness when used with included mounting screws Dimensions Weight DCA1 DCA2 Min 0 -40 0 Typ. mA mA Large Terminals (-DCA2 only) 10-24 AWG 10mm (0.39 in.) 1.13N-m (10 lb.-in) Max 50 70 85 Units °C °C %RH Splash and dust resistant #4-20 0.5” thread forming 9 in-lb (1 N-m) 0.062 in. (1.6mm) 0.25 in. (6.3mm) See Mechanical specifications for details 2.3 (65) 2.7 (77) oz. (g) www.murata-ps.com DMR35-DCA.A01.D04 Page 2 of 8 DMR35-DCA Series Precision DC Shunt Ammeter OPERATION: Measurement Type and Capabilities The DMR35 series of digital ammeters employ a precision ADC and a low-power microcontroller to measure DC current. These meters provide full-scale measurement ranges spanning 1 ampere to 25 amperes with extremely low burden voltages. These meters measurement systems supports a commonmode input voltage range of up to +/-48V with respect to the power supply return (-VS connection), simplifying high-side, low-side, and negative rail current measurements. FRONT PANEL & FRONT PANEL LAYOUT AND FUNCTION Bar-graph Display: The 21 segment bar-graph display responds quickly and smoothly like an analog meter movement to aid in reading rapidly changing measurements. Numeric Display: The 3-1/2 digit display provides precise measurements for steady-state and slowly changing measurement values. REAR PANEL LAYOUT AND SCREW TERMINAL CONNECTIONS Four screw terminals are provided for power and measurement connections, as well as a 5-position DIP switch for meter configuration, as described below. Rear Layout Terminal # Name Function 1 +VS Power supply input terminals (9-32 VDC) DM35-DCA1 2 -VS 3 +I_IN Current measurement input terminals 4 -I_IN DIP Switch: Five individual switches support display intensity settings (SW1-SW2) and measurement range selection (SW3-SW5) DMR35-DCA2 Note: It is important to tighten all screw-terminals to their torque specifications. Proper tightening will help ensure reliable operation. Applications subject to vibration should use stranded wire. (large terminal block for 25A) POWER SUPPLY CONNECTIONS The meter is powered through the +VS and –VS terminals and requires a DC power supply which may range from 9VDC to 32VDC. This supply is electrically isolated from the meter’s measurement electronics, so that the meter’s measurement input terminals (+I_IN, -I_IN) do not need to be connected to the meter’s power return terminal (-VS), and may vary as much as +/-48V from this connection. Please note that the meter’s isolation barrier is intended only to simplify measurements, and not for safety purposes – the maximum voltage between the power supply terminals (+VS or – VS) and the measurement input terminals (+I_IN, -I_IN) must be limited to +/-48VDC. The DMR35 series of meters incorporates protection against momentary applications of both overvoltage and reverse polarity to the power supply(+VS, -VS) terminals. Depending on regulatory and application requirements it may also be necessary for the user to add external fusing. MEASUREMENT INPUTS Current to be measured by the DMR35 is passed through the +I_IN and –I_IN terminals. This requires that the meter be inserted in the line in which the current is to be measured. Unlike many panel meters, the DMR35 series’ measurement inputs are electrically isolated from the power supply terminals, which allows for fully differential measurements over a common-mode range of +/-48V with respect to the power supply terminals +VS or VS. www.murata-ps.com DMR35-DCA.A01.D04 Page 3 of 8 DMR35-DCA Series Precision DC Shunt Ammeter CONNECTION EXAMPLES The schematic below shows how a DMR35 DC current meter can be used to perform a ‘high-side’ current measurement, where the meter is inserted into the load’s positive leg. In this example, the meter is powered from the same power source powering the load, and the meter’s current sensing terminals (+I_IN, -I_IN) are at a potential of 12 volts higher than the meter’s negative power terminal (-VS). The meter can also just as easily be used to measure current in the load’s negative leg (‘low-side’ current sensing). It is also possible to use the meter to monitor voltage in a circuit that is independent of the meter’s power supply circuit, as shown in the schematic below. When used in this way, the meter’s current measuring terminals may electrically float with respect to its power supply terminals, as long as the voltage difference between the two terminal pairs remains within +/- 48V of each other. www.murata-ps.com DMR35-DCA.A01.D04 Page 4 of 8 DMR35-DCA Series Precision DC Shunt Ammeter METER CONFIGURATION Meter Range Settings DMR35 meter configuration is controlled through a 5-position DIP switch (SW1-SW5) on the rear of the meter. The individual switches are labelled 1 through 5 on the unit, and the ON position of the switches is also labelled. These switches are used to select both the meter’s measurement range and the display intensity (brightness). Switches SW3 through SW5 select the meter’s measurement range, as shown in the table below. Note that for these five meter models, switch SW3 selects either unipolar (OFF) or bipolar (ON) measurement ranges. Switches SW4 and SW5 select the magnitude of the measurement range. SW3 Switch Setting SW4 SW5 DIP switch DMR35 Model -DCA1 -DCA2 OFF OFF OFF 0-1 A 0-10 A OFF OFF ON 0-2 A 0-15 A OFF ON OFF 0-3 A 0-20 A OFF ON ON 0-5 A 0-25 A ON OFF OFF ±1 A ±10 A ON OFF ON ±2 A ±15 A ON ON OFF ±3 A ±20 A ON ON ON ±5 A ±25 A The meter behaves differently depending on whether bipolar or unipolar range setting is selected. When the meter is set to a bipolar range setting, it will display measurements over a +/- range, flashing the display to indicate overflow for input values greater than +RANGE, and flashing the display to indicate underflow for input values less than – RANGE. A zero-value measurement will illuminate a single center LED. Increasingly negative input values will illuminate the bargraph from center to the leftmost LED until all left-side LEDs are illuminated at negative full-scale, and increasingly positive input values will illuminate the bargraph from center to the rightmost LED until all right-side LEDs are illuminated at positive fullscale. When set to a unipolar range setting, the meter will display measurements over a positive only range. Negative input values will result in an underflow condition of a flashing zero reading. Positive input values exceeding the maximum range will result in a flashing overflow condition. The bargraph will indicate a measurement of zero or less by illuminating the leftmost LED, and increasingly positive input values will illuminate the bargraph to the rightmost LED until all LEDs are illuminated at positive fullscale. The DMR35 meter family provides the ability to adjust the display intensity to maximize readability over a range of ambient lighting conditions. Switches SW1 and SW2 select the display intensity, as shown in the table below. The meter provides for four settings (LOW, MEDIUM, HIGH, and HIGH+). Note that the HIGH2 setting results in only a slightly higher brightness than the HIGH setting. Display Intensity Settings Set the display intensity by setting the switches as shown: 3 SW1 SW2 Dipswitch Display Intensity OFF OFF Low OFF ON Medium ON OFF High ON ON High2 †3 Provides only slightly higher intensity than ‘High’ setting www.murata-ps.com DMR35-DCA.A01.D04 Page 5 of 8 DMR35-DCA Series Precision DC Shunt Ammeter TECHNICAL NOTES 1. Calibration The DMR35 is calibrated at the factory at manufacture. There are no user or field-adjustable calibration features. 2. Wiring Power supply and input wiring must be rated for the electrical and environmental conditions under which the meter will be operated. They must also comply with any regulatory or application-mandated requirements pertaining to the user’s installation. The terminal blocks can accommodate wire gauges ranging from #14 to #24 AWG (#10-#24 for the large terminal blocks used on the DMR35-DCA2). Wiring Insulation should be stripped to the proper length as described in Terminal Block specifications table and wires must be inserted into the terminal block openings such that the screw terminal does not pinch any insulation. It is important to tighten all screw-terminals to their torque specification, which also may be found in the Terminal Block specifications table. Proper tightening will help ensure reliable operation. Applications subject to vibration should use stranded wire. After final assembly, inspect all terminal block connections for shorts between adjacent conductors; this step is especially important when using stranded wire. 3. Protection and Fusing DMR35 meters’ power supply leads (+VS, -VS) are protected against momentary overvoltage and reverse polarity conditions. Input terminals +I_IN and –I_IN are protected against noise and brief transients. Protection, however, is not provided against sustained conditions exceeding the limits listed in in the Performance & Functional Specifications Table. External fusing must be supplied by the user in accordance to applicable safety and regulatory requirements for the system in which the DMR35 is installed. 4. Noisy Power Supplies Some power supplies contain high-frequency switching devices that may conduct and/or radiate significant noise onto the low-level signal developed across the measurement inputs. Even though the DMR35 incorporates built-in input filtering, some portion of this noise may be amplified and subsequently measured by its sensitive input circuitry. Limiting runs of wire to less than 3 meters (10 feet) is strongly recommended. Also, in systems with noisy power supplies, connecting an external, non-polarized capacitor across the +VS and -VS inputs can help reduce measurement errors. In certain situations, the use of twisted pair or shield wiring may be required. 5. Self-Diagnostics On power-on the meter performs a self-test and checks the integrity of calibration data stored in internal non-volatile memory. If the factory calibration data has been corrupted, the meter will display ‘CAL’ on power-on and approximately once a minute thereafter to indicate that the meter is relying on default calibration factors and that displayed measurements may have more than the datasheet-specified amount of error. If the meter detects other internal fault conditions, it will attempt to reset itself. Repeated restarts, which appear in the form of a highly intermittent display, are indicative of a hardware fault that cannot be cleared through a reset operation, in which case the meter should no longer be used. www.murata-ps.com DMR35-DCA.A01.D04 Page 6 of 8 DMR35-DCA Series Precision DC Shunt Ammeter PANEL INSTALLATION Panel Drill Template MECHANICAL SPECIFICATIONS DMR35-DCA1-DC1-R Panel Mounting DMR35-DCA2-DC1-R www.murata-ps.com DMR35-DCA.A01.D04 Page 7 of 8 DMR35-DCA Series Precision DC Shunt Ammeter STANDARD PACKAGING Murata Power Solutions, Inc. 129 Flanders Rd. Westborough, Ma 01581, USA. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. ©2021 Murata Power Solutions, Inc.. www.murata-ps.com DMR35-DCA.A01.D04 Page 8 of 8
DMR35-DCA3-DC1-R
- 物料型号:DMR35-DCA1-DC1-R(1-5A 范围,红色显示屏,9-32VDC 供电)和 DMR35-DCA2-DC1-R(10-25A 范围,红色显示屏,9-32VDC 供电)。 - 器件简介:该系列电流表可以进行精确的直流电流测量,提供两种型号,测量范围从 1A 到 25A。 - 引脚分配:电流输入通过 +I_IN 和 –I_IN 端子,电源通过 +VS 和 –VS 端子供电。 - 参数特性:具有 0.8% 的测量精度,内部精密分流电阻,可从 9 到 32VDC 供电,典型电流消耗为 37mA(12VDC 时)。 - 功能详解:包括数字显示和条形图显示,快速响应的 21 段条形图,以及通过 DIP 开关选择的测量范围和显示亮度。 - 应用信息:适用于实验室仪器、工厂自动化以及其他需要精确直流电流监控的应用。 - 封装信息:坚固的聚碳酸酯外壳,可使用提供的螺丝安装在圆形孔中,设计为许多常见模拟运动仪表的机械替代品。
DMR35-DCA3-DC1-R 价格&库存

很抱歉,暂时无法提供与“DMR35-DCA3-DC1-R”相匹配的价格&库存,您可以联系我们找货

免费人工找货
DMR35-DCA3-DC1-R
  •  国内价格 香港价格
  • 1+1110.869271+143.90279

库存:0