EUS15-120

EUS15-120

  • 厂商:

    MURATA-PS(村田)

  • 封装:

  • 描述:

    EUS15-120 - BUS CONVERTER - Murata Power Solutions Inc.

  • 详情介绍
  • 数据手册
  • 价格&库存
EUS15-120 数据手册
BUS CONVERTER EUS15-120 Model Features: 48 Vin, Isolated, 4:1 Fixed Conversion Ratio 220 Watt Nominal Output (at 48 Vin, 55 C, 200 LFM) 170 Watt Output (at 38 Vin, 55 C, 200 LFM) Industry Standard 1/8 Brick Footprint Remote Enable (Primary Side, Positive or Negative) Over-temperature and Over Current Protection Direct Parallel Operation for Higher Power Applications RoHS Compliant Table 1 Input Characteristics Input Voltage Operating Range Input Voltage Absolute Maximum Input Undervoltage Lockout Turn-on Threshold Turn-off Threshold Hysteresis Voltage Turn-on Threshold Turn-off Threshold Hysteresis Voltage Steady-State (23 A out) Enabled state, on load (48 Vin) Disabled state (48 Vin) Notes & Conditions (1) Min 36 36 34 2 56 55 2 5.5 80 6 50 0.2 On State range Off State range On State range Off State range -0.1 2.4 2.4 -0.1 0.8 5.0 5.0 0.8 58 57 Typ. 48 Max 55 60 37.5 35.5 Units Vdc Vdc Vdc Vdc Vdc Vdc Vdc Vdc Adc mA mA mA p-p 2 As Vdc Vdc Vdc Vdc Input Overvoltage Lockout Maximum Input Current No-Load Input Current Disabled Input Current Input Reflected Ripple Current Inrush Current Transient Enable – Negative Logic Version Internal 10 K pull-up to 5 V. Enable – Positive Logic Version Internal 100 K pull-down to GND. Table 2 Output Characteristics Output Voltage Set Point (Vo=Vin/4 +0/-0.5%) Output Load Regulation Output Voltage Total Regulation Output Ripple Voltage & Noise Output Current Operating Range Efficiency Turn-On Time Start-up Inhibit Time Transient Response (3) Maximum Output Capacitance (4) Notes & Conditions (1) Vin = 48.0 V, Io = 0 A Io = 0 to 15 A Vin = 36 to 55 V, Io = 0 to 15 A, Vin = 42 to 53 V, Io = 0 to 15 A, 20 MHz Bandwidth Vin = 48 V, Io = 15 A Vin present: Enable to 90% Vout Enabled: Vin applied to 90% Vout 25% step, 0.1A/μs, ΔVo Recovery Time Min 11.94 8.3 9.7 90 0 96 10 80 160 100 3000 Typ. 11.98 0.7 Max 12.0 13.75 13.25 150 15 Units Vdc V Vdc Vdc mV p-p A % mS mS mV μs μF Technical enquiries email: sales@murata-ps.com tel: +508 339 3000 , 1 BUS CONVERTER EUS15-120 Model Table 1 Protection Characteristics Output Over-Current Shutdown Short Circuit Current Over Temperature Shutdown (5) Over Temperature Restart Hysteresis Notes & Conditions (1) Non-Latching Re-start rate Peak Non-Latching Min 21 Typ. 23 TBD TBD 125 10 Max 25 Units A msec Ap °C °C 130 Table 2 General Specifications Isolation Voltage Isolation Resistance Storage Temperature Range Operating Temperature Range Thermal Measurement Location Temperature (7) Material Flammability MTBF Notes & Conditions (1) Input to Output Input to Output Non-condensing Ambient (7) See mechanical drawing for location UL 94V-0 Calculated (Bellcore TR-332) Demonstrated 2.28”L x 0.9”W x 0.48”H (max) (57.9L x 22.9W x 12.19H mm max) Min 2250 10 -40 -40 Typ. Max Units Vdc Mohm °C °C °C x10 Hrs 6 x10 Hrs 6 125 100 120 TBD TBD 1 Dimension Weight grams Table 3 Standards Compliance UL/CSA 60950 EN60950 Notes & Conditions (6) Basic Insulation Certified by TUV Notes: (1) (2) (3) (4) (5) (6) (7) Vin = 48Vdc, Ta = 25 °C, Airflow = 200 LFM for all data unless otherwise noted. Output ripple voltage and noise is specified when measured with no external capacitance. Transient response is specified without a capacitor at the output of the converter. Product operates with an external capacitance greater than specified. For higher values please contact a Celestica representative. Thermal shutdown is monitored at the Thermal Measurement Location (TML). See ‘Mechanical Information’ on page 3 for TML location. See ‘Safety Considerations’ shown on last page. De-rating curves are conducted in a controlled environment. End application testing is required to ensure the Thermal Measurement Location temperature is below the maximum specified. (8) Recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow). 2 BUS CONVERTER EUS15-120 Model Mechanical Information Figure 1 Pin Assignment Table 4 Pin # 1 2 3 4 5 Pin Name Vi(+) En Vi(-) Vo(-) Vo(+) Function Positive Input Voltage Input Enable / Disable Negative Input Voltage Negative Output Voltage Positive Output Voltage Referenced to Vi(-). Positive Logic: Floating = Enabled Negative Logic: Floating = Disabled Notes & Conditions 3 BUS CONVERTER EUS15-120 Model Efficiency Curves Efficiency (%) vs. Iout (A) and Vin (V) 97% 96% 95% 94% 93% 92% 91% 90% 89% 88% 0 2 4 6 8 10 12 14 16 18 20 55Vin 48Vin 42Vin 38Vin Figure 2 Output Voltage vs. Current Vo (V) vs. Io (A) and Vin (V) 14 13 12 11 10 9 8 7 6 0 2 55 Vin 48 Vin 42 Vin 38 Vin 4 6 8 10 12 14 16 18 20 Figure 3 4 BUS CONVERTER EUS15-120 Model Thermal Derating Curves (Transverse) TTML=120C Iout (A) vs. Tamb (C) and Air Flow (LFM) 38 Vin 24 22 20 18 16 14 12 10 8 6 4 2 0 25 24 22 20 18 16 14 12 10 8 6 4 2 0 Airflow from pin 3 to pin 1 Iout (A) vs. Tam b (C) and Air Flow (LFM) 42 Vin 100 LFM 200 LFM 300 LFM 400 LFM 35 45 55 65 75 85 100 LFM 200 LFM 300 LFM 400 LFM 25 35 45 55 65 75 85 Figure 4 Iout (A) vs. Tam b (C) and Air Flow (LFM) 48 Vin 24 22 20 18 16 14 12 10 8 6 4 2 0 25 24 22 20 18 16 14 12 10 8 6 4 2 0 Figure 5 Iout (A) vs. Tam b (C) and Air Flow (LFM) 55 Vin 100 LFM 200 LFM 300 LFM 400 LFM 35 45 55 65 75 85 100 LFM 200 LFM 300 LFM 400 LFM 25 35 45 55 65 75 85 Figure 6 Figure 7 5 BUS CONVERTER EUS15-120 Model Pout (W) vs. Tamb (C) and Vin (V) 200 LFM 275 250 225 200 175 150 125 100 75 50 25 0 25 38 Vin 42 Vin 48 Vin 55 Vin 35 45 55 65 75 85 Figure 8 6 BUS CONVERTER EUS15-120 Model Turn-on from Vin (Enable On) Turn-on from Enable (Vin present) Figure 9 Ch3: En; Ch2: Vout Vin=48V, Io=15A, Co=3000uF Figure 10 Ch3: Vin; Ch2: Vout Vin=48V, Io=15A, Co=3000uF Output Ripple/Noise Figure 11 Vin=48V, Io=15A Vripple = 114 mVpp 7 BUS CONVERTER EUS15-120 Model Safety Considerations The EUS series of converters are certified to the standards listed in the ‘Standards Compliance’ section in the table above. If this product is built into information technology equipment, the installation must comply with the above standard. An external input fuse (10 A recommended), must be used to meet the above requirements. The output of the converter [Vo(+)/Vo(-)] is considered to remain within SELV limits when the input to the converter meets SELV or TNV-2 requirements. The converters and materials meet UL 94V-0 flammability ratings. Figure 12 Ordering Information
EUS15-120
1. 物料型号: - 型号为EUS15-120,由Murata Power Solutions生产。

2. 器件简介: - 该器件是一个隔离的DC-DC转换器,具有48V输入,4:1固定转换比率,最大输出功率为220W(在48V输入,5.20MHz时),170W输出功率(在38V输入,5.20MHz时)。它符合行业标准的1/8砖式封装,具有远程使能功能,支持正负逻辑版本,并具有过温和过流保护。

3. 引脚分配: - 引脚1:Vin(+),正输入电压。 - 引脚2:ON/OFF,输入使能/禁用。 - 引脚3:Vin(-),负输入电压。 - 引脚4:Vout(-),负输出电压。 - 引脚5:Vout(+),正输出电压。

4. 参数特性: - 输入电压范围:36Vdc至55Vdc。 - 最大输入电流:5.5A。 - 输出电压设定点:11.94V至12.0Vdc。 - 输出电流范围:0至15A。 - 效率:在48V输入,15A输出时为96%。

5. 功能详解: - 该转换器支持直接并联以获得更高的功率输出。 - 符合RoHS标准。 - 具有过温和过流保护功能。 - 封装符合UL94V-0可燃性等级。

6. 应用信息: - 适用于需要隔离和固定转换比率的应用,如信息技术设备。

7. 封装信息: - 封装尺寸为57.9L x 22.9W x 12.19H mm,最大尺寸为2.28”L x 0.9”W x 0.48”H。
EUS15-120 价格&库存

很抱歉,暂时无法提供与“EUS15-120”相匹配的价格&库存,您可以联系我们找货

免费人工找货