MGJ3 Series
www.murata.com
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
SELECTION GUIDE
Input
Voltage
Range
Rated Output Current
Output Power
Rated Output Voltage
Rated Output Current
Output Power
Typical
Application
V
See page 7
V
mA
W
V
mA
W
Order Code1
FEATURES
Output 2
Rated Output Voltage
Output 1
No opto feedback
MGJ3T05150505MC
4.5 - 9
IGBT
+15
120
1.8
-10
120
1.2
Patents protected
MGJ3T12150505MC
9 - 18
IGBT
+15
120
1.8
-10
120
1.2
Optimised bipolar output voltages for IGBT/
SiC & Mosfet gate drives
MGJ3T24150505MC
18 - 36
IGBT
+15
120
1.8
-10
120
1.2
MGJ3T05150505MC
4.5 - 9
SiC
+20
120
2.4
-5
120
0.6
Configurable dual outputs for all gate drive
applications: +15V/-5V, +15V/-10V & +20V/5V outputs
MGJ3T12150505MC
9 - 18
SiC
+20
120
2.4
-5
120
0.6
MGJ3T24150505MC
18 - 36
SiC
+20
120
2.4
-5
120
0.6
MGJ3T05150505MC
4.5 - 9
MOSFET
+15
150
2.25
-5
150
0.75
Reinforced insulation to UL60950
recognised
MGJ3T12150505MC
9 - 18
MOSFET
+15
150
2.25
-5
150
0.75
MGJ3T24150505MC
18 - 36
MOSFET
+15
150
2.25
-5
150
0.75
SELECTION GUIDE (Continued)
V
See page 7
MGJ3T05150505MC
4.5 - 9
IGBT
3
10
69
200
3
10
98
150
MGJ3T12150505MC
9 - 18
IGBT
3
10
85
200
3
10
108
150
MGJ3T24150505MC
18 - 36
IGBT
3
10
83
200
3
10
104
150
MGJ3T05150505MC
4.5 - 9
SiC
3
10
118
275
3
10
49
75
MGJ3T12150505MC
9 - 18
SiC
3
10
139
275
3
10
54
75
MGJ3T24150505MC
18 - 36
SiC
3
10
135
275
3
10
52
75
MGJ3T05150505MC
4.5 - 9
MOSFET
3
10
69
200
3
10
49
75
MGJ3T12150505MC
9 - 18
MOSFET
3
10
85
200
3
10
54
75
MGJ3T24150505MC
18 - 36
MOSFET
3
10
83
200
3
10
52
75
105°C operating temperature
For full details go to
https://www.murata.com/englobal/products/power/rohs
Ripple & Noise (Max)2
Typical
Application
5V, 12V & 24V input voltages
Offering configurable dual output voltages of +15V/10V, +20V/-5V and +15V/-5V, the MGJ3 series of
DC-DC converters is ideal for powering ‘high side’
and ‘low side’ gate drive circuits for IGBTs, Silicon
and Silicon Carbide Mosfets in bridge circuits.
A choice of asymmetric output voltages allows
optimum drive levels for best system efficiency
and EMI. The MGJ3 series is characterised for high
isolation and dv/dt requirements commonly seen in
bridge circuits used in motor drives and inverters.
A disable/frequency synchronisation pin simplifies
EMC filter design. The MGJ3 protection features
include short circuit protection and overload
protection.
Ripple & Noise (Typ)2
Input
Voltage
Range
Continuous barrier withstand voltage 3kVDC
PRODUCT OVERVIEW
Load Regulation (Max)3
Order Code1
Load Regulation (Typ)3
Ultra low isolation capacitance 15pF
Load Regulation (Max)3
5.2kVDC isolation test voltage ‘Hi Pot Test’
Load Regulation (Typ)3
Characterised partial discharge performance
Output 2
Ripple & Noise (Max)2
Output 1
Characterised CMTI >100kV/μS
Ripple & Noise (Typ)2
ANSI/AAMI ES60601-1 1MOPP/2MOOPs
recognised
%
mVp-p
%
mVp-p
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
MGJ3TXX150505MC-R7 (23 pieces per reel), or MGJ3TXX150505MC-R13 (92 pieces per reel).
2. See ripple & noise test method.
3. Between 50% and 100% rated output current.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata.com
KDC_MGJ3C.G01 Page 1 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
Isolation
Capacitance
MIL 217
V
5
mA
760
75
78.5
pF
15
889
6662
MGJ3T12150505MC
12
310
78
82
15
939
6596
MGJ3T24150505MC
24
155
77
81
15
915
6596
%
MTTF1
Telecordia
Efficiency
(Typ)
Input Current
at Rated Load
MGJ3T05150505MC
Order Code
Efficiency
(Min)
Nominal Input
Voltage
SELECTION GUIDE (Continued)
kHrs
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
5V input types
12V input types
24V input types
Turn on threshold MGJ3T05
Turn off threshold MGJ3T05
Turn on threshold MGJ3T12
Turn off threshold MGJ3T12
Turn on threshold MGJ3T24
Turn off threshold MGJ3T24
5V input types
12V input types
24V input types
4.5
9
18
5
12
24
4.1
3.0
8.1
7.5
16.7
16.1
18
12
9
9
18
36
V
Parameter
Conditions
Min.
Typ.
Max.
Units
Minimum load
Voltage set point accuracy
Line regulation
Below 10% load, 5V and 15V outputs are clamped to 6V and 16V respectively
Nominal output voltages are at 75% loading
Low line to high line
Peak deviation (50-100% & 100-50% load swing)
Settling time
2
%
%
%
%Vout
ms
Max.
Units
Voltage range
Under voltage lock out
Input ripple current
V
mA
p-p
OUTPUT CHARACTERISTICS
Transient response
10
±4
1.2
0.25
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Continuous barrier withstand voltage
UL60950-1
Safety standard
ANSI/AAMI ES60601-1
Conditions
Min.
Flash tested for 1 second
Qualification tested for 1 minute
Viso = 1kVDC
Non-safety barrier application
Reinforced
1 MOPP/2 MOOP
5200
5200
100
Typ.
VDC
3000
250
250
Creepage and clearance 7mm
GΩ
V
Vrms
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Switching frequency
Max.
100
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Operation
Storage
Product temperature rise above ambient
See derating graphs
-40
-50
100% Load, Nom VIN, Still Air
Typ.
Max.
Units
105
125
°C
18
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Input voltage, MGJ3 5V input types
Input voltage, MGJ3 12V input types
Input voltage, MGJ3 24V input types
Continuous
12V
20V
40V
1. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load.
www.murata.com
KDC_MGJ3C.G01 Page 2 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MGJ3 series of DC-DC converters are all 100% production tested at 5.2kVDC for 1 second and qualification tested at 5.2kVDC for 1 minute.
The MGJ3 series is recognised by Underwriters Laboratory, please see safety approval section for more information. When the insulation in the MGJ3 series is not used as a safety
barrier, i.e. provides functional isolation only, continuous or switched voltages across the barrier up to 3kV are sustainable. This is established by measuring the partial discharge
Inception voltage in accordance with IEC 60270. Please contact Murata for further information.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
SAFETY APPROVAL
ANSI/AAMI ES60601-1
The MGJ3 series is recognised to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working
voltage of 250 Vrms max, between Primary and Secondary.
UL 60950
The MGJ3 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms with a maximum measured product
operating temperature of 105°C.
Creepage and clearance 7mm.
FUSING
The MGJ3 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below.
Input Voltage, 5V 2A
Input Voltage, 12V 1A
Input Voltage, 24V 0.5A
All fuses should be UL recognised, 125V rated.
RoHS COMPLIANCE, MSL, PSL AND REFLOW SOLDERING INFORMATION
This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC and Time Above
Liquidus for 90 seconds, as per J-STD-020. Please refer to application notes for further information. The pin termination
finish on this product series is Gold with Nickel Pre-plate. The series is backward compatible with Sn/Pb soldering
systems. The series has a Moisture Sensitivity Level (MSL) 2. Samples of the product series were tested in accordance
with the conditioning described for MSL level 2 in IPC/J-STD-020. The product series passed electrical tests, co-planarity
and visual inspection criteria.
www.murata.com
KDC_MGJ3C.G01 Page 3 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
ENVIRONMENTAL VALIDATION TESTING
The following tests have been conducted on this product series, please contact Murata if further information about the tests is required.
Test
Standard
Condition
Temperature cycling
MIL-STD-883 Method 1010,
Condition B
10 cycles between two chambers set to achieve -55°C and +125°C.The dwell time shall not be less than 10min and the
load shall reach the specified temperature in 15min.
HAST (Unbiased)
High Temperature
Storage life
JEDEC JESD22-A118
JEDEC JESD22-A103
Condition A
96Hrs +2/-0Hrs at 130°C ± 2°C, 85% ± 5% R.H.
Vibration
BS EN 61373 with respect to BS
EN60068-2-64, Test Fh Category
1 Class B
5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest
factor: 3 Sigma. Device is secured via surface mount pins.
Shock
BS EN 61373, Category 1 class B
Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axis (18 shocks total). Level at each
axis: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via surface mount pins.
Solderability
EIA/IPC/JEDEC J-STD-002, Test
S and S1
The parts are conditioned in a steam ager for 8 hours ±15 min. at a temperature of 93±3°C.
SnPb (Test S): The parts are placed onto a stencil with Sn60Pb40 solder paste on and then placed into the reflow oven at
215 ±5°C for 50–70 seconds.
Pb-free (Test S1): The parts are placed onto a stencil with Sn96.5Ag3.0Cu0.5 solder paste on and then placed into the
reflow oven at 245±5°C for 30–60 seconds.
Solvent cleaning
Resistance to cleaning agents
Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C - 65°C.
Solvent Resistance
MIL-STD-883 Method 2015
The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The
parts are brushed 3 times, after the third time the parts are blown dry and inspected.
Moisture sensitivity
level (MSL 2)
Based on IPC/JEDEC J-STD-020
Bake samples at 125 +5/-0°C for 24hours minimum before conditioning in the temperature/humidity chamber for 168
hours at 85°C/60%RH and Pb Free JEDEC Max profile conditioning with electrical testing, co-planarity inspection before
and after.
125°C +10/-0°C for ≥1000 hours.
PART NUMBER STRUCTURE
MGJ 3 T XX XXXXXX M C -RXX
Series name
Packaging code
Power rating
R7 - 7 inch reel
R13 - 13 inch reel
Output type
RoHS compliant
S - Single
D - Dual
T - Triple
Q - Quad
Input voltage
Package type
S - SIP
D - DIP
M - Surface mount
Z - ZIP
Output voltage
www.murata.com
KDC_MGJ3C.G01 Page 4 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata.com
KDC_MGJ3C.G01 Page 5 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
APPLICATION NOTES
Disable/Frequency synchronisation
Please refer to application notes for further information.
Min
Pull Down Current
Input High
Input Low
Frequency Range
Duty Cycle
Disable/Sync1
Synchronisation
Typ
0.5
2
-0.6
90
25
100
Max
60
0.8
110
75
Units
mA
V
V
kHz
%
The Disable/Synchronization pin has three modes:
1.
2.
3.
When a DC logic low voltage is applied to this pin the MGJ3 is disabled and enters a low quiescent current sleep mode.
When this pin is left floating or a DC logic high (CMOS/TTL compatible) voltage is applied the MGJ3 is enabled and operates at the programmed frequency of
100kHz.
When a square wave of between 90kHz and 110kHz is applied to this pin, the switcher operates at the same frequency as the square wave. The falling edge of
the square wave corresponds to the start of the switching cycle. If the signal is slower than 25Hz, it will be interpreted as enabling and disabling the part. If the
MGJ3 is disabled, it must be disabled for 7 clock cycles before being re-enabled.
Note: The Dis/Sync pin is a high impedance TTL input and can be triggered by noise from external circuits if not treated carefully.
Please refer to “LAYOUT CONSIDERATIONS” and “SYNCHRONISATION CIRCUIT” for further details.
Click here for general guidance for gate drive applications.
LAYOUT CONSIDERATIONS
Unlike standard isolated DC-DC products the MGJ3 series has been designed specifically for high side gate drive applications where the outputs are being driven to a high
voltage at a very high dV/dT. This is possible due to minimum transformer isolation capacitance and considered circuit design regarding common mode transient immunity.
It is important that these few simple pcb layout guidelines are implemented so as not to compromise the performance of the DC-DC and that of the overall system.
1.
The keep clear area shown must not have any copper traces even on internal layers. This is not only to avoid compromising the creepage and clearance distance but
also to minimise capacitive isolation between the noisy output circuits and input control circuits. In general it is good practice to maintain the same band of clearance
area running directly through both the DC-DC and the gate drive isolators as shown so that input and output are kept separate and do not overlap or mesh together
at any point.
2.
A top layer ground plane copper area connected to –Vin can be used to create an effective screen to the underside of the MGJ3 series and can also be used as a
guard ring for the gate drive isolator inputs. If the Dis/Synch pin is being used then it is imperative that it follows a route covered by this screen to avoid differential
pick up. It should also be kept as short as possible.
Please refer to “PACKAGE SPECIFICATIONS” for recommended layout.
SYNCHRONISATION CIRCUIT
U1
C1
100nF
DIS/Sync
D1
R1
10kΩ
Vin-
Sync
U2
C2
100nF
DC-DC 1
DIS/Sync
D2
R2
10kΩ
Vin-
DC-DC 2
1.
A suggested synchronisation circuit is shown. C1 and C2 are 100nF capacitors. D1 and D2 are schottky diodes. The capacitive isolation and close connected diode
ensures that a transition from high to low is seen at the input pin even in a noisy environment or when there is a slight ground shift between devices.
2.
If the Dis/Sync pin is not used for synchronisation, then a 22nF capacitor can be added between the Dis/Sync pin and –Vin pin to improve noise immunity. If the
functionality of Dis/Sync is not required, the Dis/Sync pin can be connected directly to the +Vin pin to improve noise immunity.
3.
One very effective method to reduce common mode transient interference is to add a common mode filter to the DC input. It may only be necessary to add one
before splitting the supply to each DC-DC.
www.murata.com
KDC_MGJ3C.G01 Page 6 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
APPLICATION NOTES (Continued)
Start-up times
Typical start up times for this series, with no additional output capacitance are:
Part No.
MGJ3T05150505MC
MGJ3T12150505MC
MGJ3T24150505MC
Start-up times
ms
15
15
15
Output capacitance must not exceed:
Output Voltage
V
15
5
Maximum output
capacitance
μF
120
220
Output configurations for power switches
Terminal
IGBT
SIC
MOSFET
(P10)
15V Output
+15V
0.12A
+20V
0.12A
+15V
0.15A
(P9)
15V Return
5VA Output
0V
No connection
0V
(P7)
5VA Return
5VB Output
No connection
0V
-5V
0.15A
(P8)
5VB Return
-10V
0.12A
-5V
0.12A
No connection
www.murata.com
KDC_MGJ3C.G01 Page 7 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
APPLICATION NOTES (Continued)
Schematic for driving IGBT, SiC & MOSFET
MGJ DC-DC CONNECTIONS FOR DRIVING IGBT DEVICES
OPTOCOUPLER
PWM DRIVE
IGBT
16
+Vin
+15V
10
MGJ3Txx150505MC
9
0V
3
1
DIS/SYNC
-Vin
7
NC
IGBT
8
-10V
MGJ DC-DC CONNECTIONS FOR DRIVING SiC DEVICES
OPTOCOUPLER
PWM DRIVE
SiC
16
+Vin
10
+20V
MGJ3Txx150505MC
7
0V
3
DIS/SYNC
9
NC
SiC
1
-Vin
8
-5V
MGJ DC-DC CONNECTIONS FOR DRIVING MOSFET DEVICES
OPTOCOUPLER
PWM DRIVE
MOSFET
16
+Vin
+15V
10
MGJ3Txx150505MC
0V
3
DIS/SYNC
NC
9
8
MOSFET
1
-Vin
-5V
7
www.murata.com
KDC_MGJ3C.G01 Page 8 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
EFFICIENCY VS LOAD
MGJ3T12150505MC
90
90
80
80
70
70
60
60
Efficiency (%)
Efficiency (%)
MGJ3T05150505MC
50
40
50
40
30
30
20
20
10
10
0
0
10
20
30
40
50
60
70
80
90
100
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
MGJ3T24150505MC
90
80
70
Efficiency (%)
60
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata.com
KDC_MGJ3C.G01 Page 9 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
DERATING GRAPHS
Derating curves are based on IPC-9592. With no derating some components may be operating at the manufacturers maximum temperature ratings.
MGJ3T05150505MC
100
90
Load (%)
80
70
4.5Vin & 5Vin still air / 4.5Vin &
9Vin 100lfm
60
9Vin still air
50
5Vin 100lfm / 9Vin 200lfm
40
4.5Vin & 5Vin 200lfm / 9Vin
400lfm
30
20
10
0
70
75
80
85
90
95
100
105
110
Temperature (°C)
MGJ3T12150505MC
100
90
80
Load (%)
70
9Vin & 12Vin still air
60
18Vin still air
50
40
18Vin 100lfm
30
9Vin & 12Vin 100lfm / 9Vin, 12Vin
& 18Vin 200lfm
20
10
0
70
75
80
85
90
95
100
105
110
Temperature (°C)
MGJ3T24150505MC
100
90
80
Load (%)
70
18Vin still air / 24Vin 100lfm
60
24Vin still air
50
36Vin still air
40
18Vin 100lfm / 18Vin & 24Vin
200lfm
36Vin 100lfm
30
20
10
0
70
75
80
85
90
95
100
105
110
Temperature (°C)
www.murata.com
KDC_MGJ3C.G01 Page 10 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The following filter circuit and filter table shows the input filters typically required to meet EN55022 Quasi-Peak Curve A or B. If a high dv/dt above 80kV/us is expected from
output to input it is advised that a common mode filter is used on the input without Y capacitors. This will reduce the common mode current and reduce interference with
primary side circuits.
L1
C2
R1
DC
C3
C4
C1
DC
L2
TO MEET CURVE B
Part Number
MGJ3T05150505MC
MGJ3T12150505MC
MGJ3T24150505MC
C1
1.5μF
1.5μF
1.5μF
L1
L2
476R8SC
476R8SC
476R8SC
C2
10nF
10nF
10nF
C3
10nF
10nF
10nF
R1
500mΩ
500mΩ
500mΩ
C4
220μF
220μF
220μF
C1, C2 & C3 Polyester or ceramic capacitor
C4
Electrolytic capacitor (note R1 could be omitted if C4 has ESR >= R1)
MGJ3T12150505MC
100
90
90
80
80
70
70
60
60
dBuV
dBuV
MGJ3T05150505MC
100
50
40
50
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
MGJ3T24150505MC
100
90
80
70
dBuV
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_MGJ3C.G01 Page 11 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
23.11±0.10 [0.910±0.004]
Pin
Function
1
-Vin
3
Dis/Sync
5VA RTN
7
22.61±0.10 [0.890±0.004]
8
SMA
PICKUP POINT
5VB
5VB RTN
15V RTN
9
SMA PICKUP POINT
(TOP OF FERRITE CORE)
13.99±0.45 [0.551±0.018]
5VA
10
15 Vout
16
+Vin
14.19±0.45 [0.559±0.018]
S
RECOMMENDED FOOTPRINT DETAILS
SEATING PLANE
0.10 S
x7 PINS
5.08±0.25 [0.200±0.010]
x7 PINS
1.60±0.05 [0 .063±0.002]
2.67±0.23 [0.105±0.009]
1
3
7
2.54 [0.100]
8
x7 PLACES
3.38 [0.133]
19.05 [0.750]
1.78±0.27 [0.070±0.011]
RECOMMENDED
ISOLATION BARRIER
x7 PLACES
2.16 [0.085]
2.54 [0.100]
19.05±0.33 [0.750±0.013]
5.08 [0.200]
15.24 [0.600]
17.78 [0.700]
x7 PINS
2.29±0.08 [0.090±0.003]
16
10
9
15.24±0.25 [0.600±0.010]
RECOMMENDED LAYOUT
17.78±0.25 [0.700±0.010]
-Vin GROUND PLANE
All dimensions in mm (inches), Controlling dimensions is mm.
Components shown for reference only
NO COPPER IN THIS
AREA ON ANY LAYER
Weight: 10.70g
Please refer to “LAYOUT CONSIDERATIONS” for further details.
www.murata.com
KDC_MGJ3C.G01 Page 12 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
REEL PACKAGING DETAILS
Ø330 [13.000] MAX
OR
Ø177.8 [7.000] MAX
[
13.50 0.531
Ø 12.80 Ø 0.504
]
50.40[1.984] MAX #
GOODS
ENCLOSURE
SECTION
LEADER SECTION
400 [15.748] MIN
TRAILER SECTION
160 [6.299] MIN
100 [3.937]
MIN
1.50 [0.059]
MIN ##
Ø20.20 [Ø0.795]
MIN
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches)
Controlling dimension is mm
# Measured at hub
## Six equally-spaced slots on 180mm/7” reel
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
Reel Quantity: 7” - 23 or 13” - 92
TAPE OUTLINE DIMENSIONS
1.75 [0.069]
Ø2.0 [Ø 0.079] MIN
2.0 [0.079]
4.0 [0.157]
[
+0.004
+0.1
Ø1.5 -0.0 Ø0.059 -0.000
]
3° MAX
20.2±0.15
[0.795±0.006]
44.0±0.3
[1.7323±0.012]
#23.7 [0.933]
40.4 [1.591]
COVER TAPE
0.2 ±0.05
3° MAX
23.2 [0.913] #
0.6 [0.024] MAX
15.65 [0.616]
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches)
Controlling dimension is mm
Components shall be orientated within the carrier tape as indicated
# Measured on a plane 0.3mm above the bottom pocket
36.0 [1.417]
DIRECTION OF UNREELING
www.murata.com
KDC_MGJ3C.G01 Page 13 of 14
MGJ3 Series
5.2kVDC Isolated 3W Gate Drive SM DC-DC Converters
DISCLAIMER
Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical
applications.
Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe
damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use.
These applications include but are not limited to:
•
Aircraft equipment
•
Aerospace equipment
•
Undersea equipment
•
Power plant control equipment
•
Medical equipment
•
Transportation equipment ( automobiles, trains, ships, etc.)
•
Traffic signal equipment
•
Disaster prevention / crime prevention equipment
•
Data Processing equipment
Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The
suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and
liability of the buyer.
Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold
Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/
or life-critical applications.
Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: https://www.murata.com/en-eu/products/power/requirements
Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use
of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change
without notice.
© 2022 Murata Power Solutions (Milton Keynes) Ltd.
www.murata.com
KDC_MGJ3C.G01 Page 14 of 14