Preliminary Specification of COAXIAL CONNECTOR
Written by
H. Kitaguchi
Preliminary SPEC No.
: NMM04-PJ0123F
Checked by
T. Kuriyama
Part Number
: MM121546
Date
16/Oct./2012
SPECIFICATION
Revised F: 22/Nov./’18 II Revised E:27/Oct./’16 KT Revised D: 27/Mar./’13 KT
Revised C: 21/Mar./’13 MR Revised B: 9/Jan./’13 KT Revised A: 27/Nov./’12 KT
1. MECHANICAL
Automatic measurement probe for JSC cable and LSC cable.
E>
Use as
Application
Auto measurement probe
JSC
LSC
MM5831-2700
Cable plug
MM7831-2700
Cable plug
Calibration adapter for MM121546 is as below.
JSC
LSC
MM121530
-
MM121530
MM121651
5 +/- 0.1
6.4 +/- 0.1
20.2 +/- 0.3
Dia. 5.8 +/- 0.1
Dia. 3.8 +/- 0.1
Dia. 3.2 +/- 0.1
Dia. 2 +/- 0.1
.
Dia
+/-
1.25 +/- 0.05
0 .1
+0.1/
-0.05
5
1.0
-0
05/
+0.
.01
6 +/- 0.1
5)
. 15
4 +/- 0.05
2-D
ia. 2.6
.52
Dia
(R
0
1.5 +/- 0.1
1.8 +/- 0.1
3.3
12.5
SMA Female
7 +/- 0.05
11 +/- 0.1
JSC/LSC Male
Scale: Free
Tolerance Unless
Otherwise Specified: +/- 0.2
Unit: mm
Figure 1 Construction
2.
RATING:
Item
Voltage Rating
Nominal Frequency Range
Nominal Impedance
Temperature Rating
Insulation Resistance
F> Withstanding Voltage
B>
Initial Contact Resistance
(without conductor resistance)
E>B> Voltage Standing Wave Ratio (V.S.W.R.)
JSC
LSC
C>
Durability
1/3
Specification
30Vr.m.s. maximum
DC to 6GHz
50
-40C to +85C
500 M minimum
No evidence of breakdown
in AC 300V r.m.s, 1 minute
Center contact 35.0mmax.
Outer contact 20.0mmax.
Meet the requirements of following spec.
1.4 max. (DC to 3GHz)
1.4 max. (3GHz to 6GHz)
Meet the requirements of following spec.
1.4 max. (DC to 3GHz)
1.5 max. (3GHz to 6GHz)
1M cycles
Preliminary Specification of COAXIAL CONNECTOR
Written by
Preliminary SPEC No.
: NMM04-PJ0123F
Checked by
Part Number
: MM121546
Date
3. USE THIS PRODUCTS
3.1 The directions for attachment to measurement fixture.
The probe must be attached to fixture at the two screw holes in probe flange. (Figure 2)
H. Kitaguchi
T. Kuriyama
16/Oct./2012
Screw Hole
Figure 2 Screw hole position
0+/-0.10mm
(Acceptable
engagement range)
Unmating
(18.84 to 19.84)
18.2 to 19.2
20.2
F>E>A>
3.2 The tolerance of position against JSC cable and LSC cable.
Probe has the centering function by itself, +/-0.10mm is permitted against the hole center of JSC cable and
LSC cable.
Please avoid needless force to SMA-Female connector to come back the original position when disengagement
of probe.
The engagement strokes from the bottom surface of flange to the tip of probe is 18.2mm to 19.2mm. (Figure 3)
Mating
Figure.3 Acceptable Engagement range to JSC cable and LSC cable
2/3
Preliminary Specification of COAXIAL CONNECTOR
Written by
Preliminary SPEC No.
: NMM04-PJ0123F
Checked by
Part Number
: MM121546
Date
E>
3.3 The slant angle tolerance of probe against JSC cable and LSC cable (Figure 4)
To have the stable measurement, MM121546 slant angle must be +/-1.5degree.
0+/-1.5 degree
Figure.4
Probe Shape Operation Manual for Auto Measurement probe
3.4 Positioning of cable connector
This probe has directionality. Cable connector must be set as follows.
D>
A
90 +/- 2deg
Cut a part of Tip must be faced to cable connecter
Detail A
Cut a part of Tip
3/3
H. Kitaguchi
T. Kuriyama
16/Oct./2012
很抱歉,暂时无法提供与“MM121546”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+2223.350461+267.11456
- 10+1812.8878210+217.80135
- 25+1729.1314525+207.73881