Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0046A
Part Number
: MM126526
Written by
H. Matsukawa
Checked by
M. Atokawa
Date
04/Jul./2014
Revised A: 13/May./’15 KA
SPECIFICATION
1. MECHANICAL
Automatic measurement probe for SWH-2WAY(MM8930-2620)
to measure RF side performance.
7.2+/-0.2
1.8+/-0.2
R
Dia.7.5+/-0.1
6.33+/-0.1
SMA-Female
SWH-2W
Dia. 2.2+/-0.1
Dia. 3.5+/-0.1
Dia. 4+/-0.1
24.6+/-0.3
1.5+/-0.1
-0.1
3+/-0.1
5.33+/-0.1
4
.1
+/-0
a.2.2
i
D
2
11.6+/-0.1
8+/-0.02
8+/-0.02
3+/-0.1
/
R8+
(38.43)
5
0.0
/+
.8
R0
2-
Scale: Free
Tolerance Unless
Otherwise Specified: +/- 0.5
Unit: mm
Figure 1 Construction
2.
RATING:
Item
Voltage Rating
Nominal Frequency Range
Nominal Impedance
Temperature Rating
Insulation Resistance
Withstanding Voltage
Specification
30Vr.m.s. maximum
DC to 6GHz
50
-40C to +85C
500 M minimum
No evidence of breakdown
AC200Vr.m.s, 1minute
70.0mmax.
Initial Contact Resistance
(without conductor resistance)
A> Voltage Standing Wave Ratio (V.S.W.R.)
2.1 max.(DC 3GHz)
2.2 max.(3GHz 6GHz)
A> Insertion Ioss
0.8 dB max.(DC 3GHz)
0.8 dB max.(3GHz 6GHz)
Durability
1M cycles
1/5
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0046A
Part Number
: MM126526
Written by
H. Matsukawa
Checked by
M. Atokawa
Date
04/Jul./2014
Revised A: 13/May./’15 KA
R
3. USE THIS PRODUCTS
3.1 The directions for attachment to measurement machine.
The probe must be attached to machine at the two screw holes in probe flange. (Figure 2)
SCREW HOLE
Figure.2 Screw hole position
3.2 The tolerance of position against MM8930-2620.
3.2.1
Probe has the centering function by itself, +/-0.5mm is permitted against the hole center of
MM8930-2620.
Please avoid needless force to SMA connector to come back the original position when disengagement of
probe. To avoid the needless force, we recommend using extension cable assembly, MXHR87HR3000. The
instruction of the MXHR87HR3000 is as Figure 3.
There is the possibility, following function +/-0.5mm is not permitted against the hole center of
MM8930-2620, when probe effects the needless force.
Over 50mm
m
Please hold the cable to
keep some margin like this
Ov
e
MXHR87HR3000
Cable holding
point
2/5
Over 30mm
rR
20
m
MM126526
To Measurement
Equipment
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0046A
Part Number
: MM126526
Written by
H. Matsukawa
Checked by
M. Atokawa
Date
04/Jul./2014
Revised A: 13/May./’15 KA
Figure.3 Instruction of MXHR87HR3000
23.1 to 23.6
(Using Area)
(23.5 to 24)
24.6
3.2.2 To get the 15dB or higher isolation (up to 6GHz), The engagement strokes from the flange to the tip
of probe is 23.1mm to 23.6mm. (Figure 4)
0.5Max
UNIT: mm
Figure.4 Acceptable engagement range to MM8930-2620
3.3 The machine's hole diameter for attachment probe.
To accept +/-0.5mm against the hole center of MM8930-2620, please design the machine by Figure 5.
To distinguish Antenna measurement probe from RF measurement probe by flange design, please design
the positioning pin by Figure 5.
3/5
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0046A
Part Number
: MM126526
Written by
H. Matsukawa
Checked by
M. Atokawa
Date
04/Jul./2014
Revised A: 13/May./’15 KA
11.6+/-0.05
8+/-0.02
2+/-0.05
8+/-0.02
Di
a.
1.4Min.
3Min.
4.1
M
in.
2-M2
2-Dia.1.5+/-0.02
Positioning pin
UNIT: mm
Figure.5 Machine’s hole diameter for attachment probe
3.4 The slant angle tolerance of probe against MM8930-2620. (Figure 6)
To have the stable measurement, MM126526 slant angle must be +/-2degree.
0+/-2degree
Figure.6 Probe Shape Operation Manual for Auto Measurement probe (MM126526)
4.
!
CAUTION
Limitation of Applications
Please do not use our products for the applications listed below which require specially high reliability for the
prevention of defects which may directly or indirectly cause damage to the third party's life, body or property.
4/5
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0046A
Part Number
: MM126526
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Written by
H. Matsukawa
Checked by
M. Atokawa
Date
04/Jul./2014
Revised A: 13/May./’15 KA
Aircraft equipment
Aerospace equipment
Undersea equipment
Power plant control equipment
Medical equipment
Transportation equipment (vehicles, trains, ships, etc.)
Traffic signal equipment
Disaster prevention / crime prevention equipment
Data-processing equipment
Application of similar complexity and/or reliability requirements to the applications listed in the above.
5/5
很抱歉,暂时无法提供与“MM126526”相匹配的价格&库存,您可以联系我们找货