Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0076A
Part Number
: MM206621
Written by
T.Yamamoto
Checked by T.Kuriyama
Date
22/Jun./2016
SPECIFICATION
Revised A: 26/Sep./’16 KT
1. MECHANICAL
Automatic measurement probe for SWH.
MM126511 and MM126512 are used as calibration adapters.
1.05+0.05/-0.01
0.8+/-0.2
20+/-0.3
4.11
1.25+/-0.05
1.50
Dia
.14
.4
SWH
Scale: Free
Tolerance Unless
Otherwise Specified: +/- 0.2
Unit: mm
Figure 1. Construction
2.
RATING:
Item
Specification
30Vr.m.s. maximum
DC to 6GHz
50
-40C to +85C
500 M minimum
No evidence of breakdown
Center contact 70.0mmax.
Outer contact 20.0mmax.
Meet the requirements of following spec.
1.5 max.(DC to 3GHz)
1.6 max.(3GHz to 6GHz)
0.3dB max.(DC to 3GHz)
0.5dB max.(3GHz to 6GHz)
250K cycles
Voltage Rating
Nominal Frequency Range
Nominal Impedance
Temperature Rating
Insulation Resistance
Withstanding Voltage
Initial Contact Resistance
(without conductor resistance)
A> Voltage Standing Wave Ratio (V.S.W.R.)
A> Insertion Ioss
A> Durability
1/4
10+/-0.1
2-Di
a.2.2
+/-0.
Dia.1
1
.05+
0.05
/-0.0
1
6+/-0.04
3.0
Dia.3.0
SMPM-Male
Dia.1.8+/-0.1
4+/-0.1
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0076A
Part Number
: MM206621
Written by
T.Yamamoto
Checked by T.Kuriyama
Date
22/Jun./2016
3. USE THIS PRODUCT
3.1 Attach to measurement machine
MM206621 must be attached to machine at the two screw holes in probe flange (Figure 2).
Using guide pins is recommended. The guide pins should not be above probe flange (Figure 3).
SCREW HOLE
Figure 2. Screw hole
Guide pin should not be above probe flange
Guide pin
Figure 3. Positional relation between guide pin and probe flange
2/4
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0076A
Part Number
: MM206621
Written by
T.Yamamoto
Checked by T.Kuriyama
Date
22/Jun./2016
3.2 The tolerance of position against SWH type receptacle
3.2.1 MM206621 has a centering function by its design, +/-0.4mm is permitted against the hole center of SWH type
receptacle.
Please avoid needless force to SMPM interface when MM206621 is disengaged from SWH type receptacle and
comes back to its original position.
To avoid the needless force, please use extension cable assembly, MXFLM3SH3000/ MXFJM3SJ3000
(Figure 4/Figure 5).
Centering function +/-0.4mm may not be permitted against the hole center of SWH type receptacle, when
MM206621 is affected by the needless force.
Please hold the cable to
keep some margin like this
Cable holding
point
Over 30mm
ve
rR
O
MXFLM3SH3000
30
m
m
Over 50mm
MM206621
To Measurement
Equipment
Figure 4. Instruction of MXFLM3SH3000
To Measurement
Equipment
MXFJM3SJ3000
MM206621
Figure 5. Instruction of MXFJM3SJ3000
Please use M19500 for un-mating MM206621 with MXFLM3SH3000/ MXFJM3SJ3000 (Figure 6).
Figure 6. SMPM interface un-mating jig: M19500
3/4
Preliminary Specification of COAXIAL CONNECTOR
Preliminary SPEC No.
: NMM04-PU0076A
Part Number
: MM206621
Written by
T.Yamamoto
Checked by T.Kuriyama
Date
22/Jun./2016
19.0 to 20.0
18.5 to 19.5
(Using Area)
20
3.2.2 To get 10dB or higher isolation (up to 6GHz), the engagement strokes from the flange to the tip
of probe is 18.5mm to 19.5mm (Figure 7).
0+/-0.4
Mating
Unmating
Unit:mm
Figure 7. Acceptable Engagement range to SWH type receptacle
3.3 The slant angle tolerance of probe against SWH type Receptacle (Figure 8)
To have a stable measurement, slant angle of MM206621 must be within +/-2degree.
0+/-2
degre
e
Figure 8. Probe Shape Operation Manual for Auto Measurement probe (MM206621)
4/4
很抱歉,暂时无法提供与“MM206621”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+1250.098681+150.38286
- 10+1019.2017210+122.60670
- 25+939.7455525+113.04837
- 50+921.2193750+110.81973