MTC2S1212MC-R13

MTC2S1212MC-R13

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    -

  • 描述:

    DC/DCSM2W12V-12V,13-INCHREE

  • 数据手册
  • 价格&库存
MTC2S1212MC-R13 数据手册
MTC2 Series www.murata.com Isolated 2W SM 2:1 Input Single Output DC-DC Converters FEATURES „ UL60950 recognised for reinforced insulation „ ANSI/AAMI ES60601-1, 1 MOPP/ 2 MOOPs recognised4 „ 3kVAC isolation test voltage ‘Hi Pot Test’ „ Continuous short circuit protection „ Output voltage trim „ Remote on/off pin „ No electrolytic capacitors „ Operation up to 105°C (with derating) „ 2:1 input range PRODUCT OVERVIEW The MTC2 series of miniature surface mount DC-DC converters offers a single output voltage from input voltage ranges of 4.5-9V, 9-18V and 18-36V. The MTC2 series regulated output voltage is adjustable by ±10% and a remote on/off pin is also included for application power saving. The MTC2 ideally suited to applications which include medical. Industrial, telecommunications, battery powered systems, and process automation. Nom. V Rated Input Current Order Code Output Current 1 Output Voltage SELECTION GUIDE V mA mA Min. % Typ. % 5 5 5 12 12 12 24 24 24 3.3 5 12 3.3 5 12 3.3 5 12 606 400 167 606 400 167 606 400 167 550 530 510 210 210 200 110 100 100 70 71 74 76 77 81 75 76 78 73 76 78.5 78.5 80 83.5 78.5 79.5 81.5 Input Voltage MTC2S0503MC3 MTC2S0505MC3 MTC2S0512MC3 MTC2S1203MC MTC2S1205MC MTC2S1212MC MTC2S2403MC MTC2S2405MC MTC2S2412MC Efficiency Ripple and Noise Typ. Max. mVp/p mVp/p 75 90 75 40 45 45 55 35 50 120 120 120 50 60 60 75 55 70 MTTF2 MIL. kHrs Tel. kHrs 1270 1287 1170 1085 1067 1067 946 854 964 2371 2670 2106 2704 3260 3004 2540 2275 2424 INPUT CHARACTERISTICS Parameter Voltage range Input reflected ripple current Conditions Min. Typ. Max. Units 5V input types 12V input types 24V input types 5V input types All other variants 4.5 9 18 5 12 24 20 4 9 18 36 V Typ. Max. mA p-p ISOLATION CHARACTERISTICS Parameter Isolation test voltage Isolation capacitance Resistance UL60950-1 Safety ANSI/AAMI Standard ES60601-1 Conditions Min. Production tested for 1 second Qualification tested for 1 minute All variants Viso = 1kVDC Reinforced Creepage and clearance 5mm 1 MOPP/2 MOOP 3000 3000 Units VAC 20 pF GΩ 1 250 250 VAC OUTPUT CHARACTERISTICS Parameter Conditions Min. Rated power All output types Minimal load to meet datasheet specification 5V input types Voltage set point accuracy All other input types Line regulation Low line to high line Load regulation All output types Typ. Max. 2 10 -2.5 0503, 0505 & 0512 All other variants 0503 0505 & 0512 All other variants Units W % ±0.05 ±0.1 ±0.05 2 ±2 ±0.2 ±0.5 ±0.2 ±0.2 ±0.5 % % 1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are MTC2SXXXXMC-R7 (30 pieces per reel), or MTC2SXXXXMC-R13 (150 pieces per reel) 2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load. 3. MTC2S05xxMC variants are currently pending recognition to UL62368-1 as UL60950 is superseded by UL62638. 4. ANSI/AAMI ES60601-1 recognition is currently pending for MTC2S05xxMC. For full details go to https://www.murata.com/englobal/products/power/rohs All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata.com KDC_MTC2.F01 Page 1 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters OUTPUT CHARACTERISTICS (Continued) Parameter Conditions Peak deviation (25-75% & 75-25% swing) Min. Typ. ±8 12V output types ±2 0503 ±4 0505 ±4.5 0512 ±1.5 1205 ±6 2405 Transient response Settling time (1% Vout Nom.) Max. 3.3V output types Units %Vout ±5 0503 420 0505 1000 0512 180 1203 45 1205 80 1212 60 2403 55 2405 75 2412 100 μs GENERAL CHARACTERISTICS Parameter Switching frequency Remote on/off pin Conditions Min. 0503 0505 0512 1203 1205, 1212 2403 2405 2412 Module on, pin unconnected or open collector floating 3.3V output types Module off (refer to application notes) 5V & 12V output types 5V input types 1203, 1205 1212 2403, 2405 2412 Typ. Max. 135 115 140 285 260 185 225 240 Units kHz 3 2 0.25 1.4 1.5 3.9 4.2 V mW TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Operation Storage Case temperature above ambient All output types (see derating curves) -40 -50 100% Load, Nom VIN, Still Air Typ. Max. Units 105 125 °C 22 ABSOLUTE MAXIMUM RATINGS Short-circuit protection (for SELV input voltages) Remote on/off pin input voltage1 Input voltage, MTC2 5V input types Input voltage, MTC2 12V input types Input voltage, MTC2 24V input types Continuous 12V 15V 25V 40V 1. Provided that external control circuit is the same as application note on page 5. www.murata.com KDC_MTC2.F01 Page 2 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MTC2 series of DC-DC converters are all 100% production tested at 3kVAC for 1 second and have been qualification tested at 3kVAC for 1 minute. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The MTC2 series has been recognised by Underwriters Laboratory to 250Vrms for Reinforced Insulation. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. SAFETY APPROVAL ANSI/AAMI ES60601-1 The MTC2 series has been recognised by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working voltage of 250 Vrms max., between Primary and Secondary. The MTC2S05xxMC variants are currently pending recognition. File number E202895 applies. UL 60950 The MTC2 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250 Vrms with a maximum measured product operating temperature of 105°C. File number E151252 applies. Creepage and clearance 5 mm. FUSING The MTC2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. Input Voltage, 5V: 0.91A (Fuse value is pending Underwriters Laboratory (UL) confirmation.) Input Voltage, 12V: 0.75A Input Voltage, 24V: 0.5A All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage. RoHS COMPLIANCE, MSL AND PSL INFORMATION This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems. The MTC2 series has a process, moisture, and reflow sensitivity classification of MSL2 PSL R7F as defined in J-STD-020 and J-STD-075. This translates to: MSL2 = 1 year floor life, PSL R7F = Peak reflow temperature 245°C with a limitation on the time above liquidus (217°C) which for this series is 90 sec max. Please refer to application notes for further information. The pin termination finish on this product series is Gold with Nickel Pre-plate. PART NUMBER STRUCTURE MTC 2 S XX XX M C -RXX Series name Packaging code Power rating R7 - 7 inch reel R13 - 13 inch reel Output type RoHS compliant S - Single D - Dual Input voltage Package type S - SIP D - DIP M - Surface mount Z - ZIP Output voltage www.murata.com KDC_MTC2.F01 Page 3 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters ENVIRONMENTAL VALIDATION TESTING The following tests have been conducted on this product series, please contact Murata if further information about the tests is required. Test Standard Condition Temperature cycling MIL-STD-883 1010, Condition B 10 cycles between two chambers set to achieve -55°C and +125°C.The dwell time shall not be less than 10min and the load shall reach the specified temperature in 15min. HAST (biased) JEDEC JESD22-A110 96Hrs +2/-0Hrs at 130°C ± 2°C, 85% ± 5% R.H. High temperature storage life JEDEC JESD22-A103, Condition A 125°C +10/-0°C for ≥1000 hours Vibration BS EN 61373 with respect to BS EN 5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest 60068-2-64, Test Fh Category 1 Class B factor: 3 Sigma. Device is secured via pins. Shock BS EN 61373: Category 1 Class B Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axes (18 shocks total). Level at each axis as follows: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via pins. Solderability IPC/ECA J-STD-002, Test A and A1 SnPb (Test A): For lead free solderability, 5 off Parts conditioned to a 48hour dry bake at 125°C followed by 4 hours at 155°C and 5 off Parts conditioned to 96hours at 125°C. All 10 Dipped in solder at 245°C ±5°C for 5 +0/-0.5 seconds. Pb-free (Test A1): For leaded solderability, 5 off Parts conditioned to a 48hour dry bake at 125°C followed by 4 hours at 155°C and 5 off Parts conditioned to 96hours at 125°C. All 10 Dipped in solder at 255°C ±5°C for 5 +0/-0.5 seconds. Solvent cleaning Resistance to cleaning agents Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C- 65°C Solvent resistance MIL-STD-883, Method 2015 The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The parts are brushed 3 times, after the third time the parts are blown dry and inspected. www.murata.com KDC_MTC2.F01 Page 4 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. C2 Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - R1 T1 R2 + Y INPUT Output - R LOAD APPLICATION NOTES Maximum Output Capacitance Maximum output capacitance should not exceed: Output Voltage V 3.3 5 12 Maximum Load Capacitance μF 470 470 220 Start-up times Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10uF (5V inputs), 470μF (3.3, 5V outputs) and 220μF (12V outputs), are shown in the table below. The product series will start into the maximum output capacitance with increased start times. Part No. MTC2S0503MC MTC2S0505MC MTC2S0512MC MTC2S1203MC MTC2S1205MC MTC2S1212MC MTC2S2403MC MTC2S2405MC MTC2S2412MC Start-up times ms 12 20 37 3 10.5 31 7 12 21 Typical Wave Form: www.murata.com KDC_MTC2.F01 Page 5 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters APPLICATION NOTES (Continued) Control Pin The MTC2 converters have a shutdown feature which enables the user to disable the converter into a low power state. The control pin connects to the base of an internal NPN transistor with the converter shut down when the transistor is turned on by an external applied voltage. The converter can also be shut down using a 5V TTL signal (the unit is OFF for logic High and ON for logic LOW). If the control pin is left open (high impedance), the converter will run normally. A suitable application circuit is shown below. Ω VIN MTC2S R2 VC or TTL -VIN R1 D1 CTRL Q1 D1 (e.g. 1N4001) is necessary for correct operation of the MTC2 when the control signal is LOW. The recommended drive current IB to shut down the MTC2 is 6mA to 15mA. The value of R1 can be derived as follows: VC - VD1 - 0.6 R1 = IB For a switch input: Calculate the value of R1 from the above equation given switch voltage Vc and chosen current between 6 and 15mA. For 5V TTL Signal: Set R1 to be between 320Ω to 800Ω. Output Voltage Adjustment The MTC2 series has a trim capability which is located at pin 3, this allows the user to independently adjust the output voltages by ±10%. Adjustments to the output voltages can be accomplished via a single fixed resistor as shown in Figures 1 and 2. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should have low temperature coefficient to minimize sensitivity to changes in temperature. A single resistor connected from the TRIM pin (pin 3) to the +Vout (pin 4), will decrease the output voltage which is shown in figure 1. A single resistor connected from the TRIM pin (pin 3) to the -Vout (pin 2) will increase the output voltage which is shown in figure 2. TRIM DOWN TRIM UP Figure 1. Trim connections to decrease the output voltage 1 +Vin -Vout 2 TRIM 3 Figure 2. Trim connections to increase the output voltage 1 -Vout +Vin 2 RTRIM 6 -Vin 5 CTRL 3.3VoutRTRIM = 5VoutRTRIM = 12VoutRTRIM = RTRIM +Vout 18.64k x Vout - 52.3k 3.32 - Vout 33.2k x Vout - 141k 5 - Vout 24.4k x Vout - 181.388k 12.2087 - Vout 4 5Vin12VoutRTRIM = 30.4k x Vout - 194.723k 12.0744 - Vout 6 -Vin 5 CTRL 3.3VoutRTRIM = 5VoutRTRIM = 12VoutRTRIM = TRIM 3 +Vout 4 14k x Vout - 52.3k 3.32 - Vout 5Vin12VoutRTRIM = 12.4k x Vout - 194.723k 12.0744 - Vout 23.2k x Vout - 141k 5 - Vout 12.4k x Vout - 181.388k 12.2087 - Vout Accuracy of adjustment is subject to tolerances of resistors and factory adjusted output accuracy. Vout is equal to the desired output voltage. www.murata.com KDC_MTC2.F01 Page 6 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters EFFICIENCY VS LOAD MTC2S0505MC 90 90 80 80 70 70 60 60 50 4.5Vin 5Vin 40 9Vin Efficiency (%) Efficiency (%) MTC2S0503MC 50 5Vin 30 30 20 20 10 10 0 0 20 40 60 80 4.5Vin 40 9Vin 0 100 0 20 40 60 Load (%) 80 100 Load (%) MTC2S0512MC MTC2S1203MC 90 90 80 70 70 60 60 50 4.5Vin 5Vin 40 9Vin Efficiency (%) Efficiency (%) 80 30 50 9 Vin 12 Vin 40 18 Vin 30 20 20 10 10 0 0 20 40 60 80 100 0 0 Load (%) 10 20 30 50 Load (%) 60 70 80 90 100 MTC2S1212MC 90 90 80 80 70 70 60 60 50 9 Vin 12 Vin 40 18 Vin Efficiency (%) Efficiency (%) MTC2S1205MC 40 50 9 Vin 18 Vin 30 30 20 20 10 10 0 12 Vin 40 0 0 10 20 30 40 50 Load (%) 60 70 80 90 100 0 10 20 30 40 50 Load (%) 60 70 80 90 100 www.murata.com KDC_MTC2.F01 Page 7 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters EFFICIENCY VS LOAD MTC2S2405MC 90 90 80 80 70 70 60 60 50 18 Vin 24 Vin 40 36 Vin Efficiency (%) Efficiency (%) MTC2S2403MC 50 18 Vin 36 Vin 30 30 20 20 10 10 0 24 Vin 40 0 0 10 20 30 40 50 Load (%) 60 70 80 90 100 0 10 20 30 40 50 Load (%) 60 70 80 90 100 MTC2S2412MC 90 80 70 Efficiency (%) 60 50 18 Vin 24 Vin 40 36 Vin 30 20 10 0 0 10 20 30 40 50 Load (%) 60 70 80 90 100 www.murata.com KDC_MTC2.F01 Page 8 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING MTC2S0503MC MTC2S0505MC 100 100 90 90 80 80 70 70 60 4.5Vin 50 5Vin 9Vin Load, % Load, % 60 4.5Vin 40 40 30 30 20 20 10 10 0 5Vin 50 9Vin 0 70 75 80 85 90 95 100 105 70 75 80 85 Temperature, C 90 95 100 105 Temperature, C MTC2S0512MC MTC2S1203MC - 12Vin 100 90 90 80 80 70 70 60 Load, % 60 4.5Vin 50 5Vin Load, % 100 No Airflow 50 100lfm 40 200lfm 9Vin 40 30 30 20 20 10 10 0 400lfm 70 80 0 70 75 80 85 90 95 100 Temperature, C 90 90 80 80 70 70 60 No Airflow 100lfm 40 200lfm 30 400lfm 60 No Airflow 50 100lfm 40 200lfm 30 20 20 10 10 0 100 MTC2S1212MC - 12Vin 100 Load, % Load, % MTC2S1205MC - 12Vin 100 50 90 Temperature C 105 400lfm 0 70 80 90 Temperature C 100 70 80 90 100 Temperature C www.murata.com KDC_MTC2.F01 Page 9 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING MTC2S2403MC - 24Vin MTC2S2405MC - 24Vin 100 100 90 90 80 80 70 60 No Airflow 50 100lfm 40 200lfm 30 Load, % Load, % 70 400lfm 60 No Airflow 50 100lfm 40 200lfm 30 20 400lfm 20 10 10 0 70 80 90 0 100 70 Temperature C 80 90 MTC2S2412MC - 24Vin MTC2S1203MC - 9Vin 100 100 90 80 80 70 70 No Airflow 60 100lfm 50 200lfm 40 Load, % Load, % 90 60 No Airflow 50 100lfm 40 200lfm 400lfm 30 30 20 20 10 10 400lfm 0 0 70 80 90 70 100 80 Temperature C 90 100 Temperature C MTC2S1205MC - 9Vin MTC2S1212MC - 9Vin 100 100 90 90 80 80 70 70 60 No Airflow 50 100lfm 40 200lfm 30 400lfm Load, % Load, % 100 Temperature C 60 100lfm 40 200lfm 30 20 20 10 10 0 No Airflow 50 400lfm 0 70 80 90 Temperature C 100 70 80 90 100 Temperature C www.murata.com KDC_MTC2.F01 Page 10 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING (Continued) MTC2S2405MC - 18Vin 100 90 90 80 80 70 70 60 No Airflow 50 100lfm 40 Load, % Load, % MTC2S2403MC - 18Vin 100 200lfm 30 60 No Airflow 50 100lfm 40 200lfm 30 400lfm 20 20 10 10 0 400lfm 0 70 80 90 100 70 Temperature C 80 90 MTC2S1203MC - 18Vin 100 100 90 90 80 80 70 70 60 No Airflow 50 100lfm 40 Load, % Load, % MTC2S2412MC - 18Vin 200lfm 30 60 No Airflow 50 100lfm 40 200lfm 30 400lfm 20 20 10 10 0 400lfm 0 70 80 90 100 70 80 90 100 Temperature C Temperature C MTC2S1205MC- 18Vin MTC2S1212MC- 18Vin 100 100 90 90 80 80 70 70 60 No Airflow 50 100lfm 40 200lfm 30 400lfm Load, % Load, % 100 Temperature C 60 No Airflow 50 100lfm 40 200lfm 30 20 20 10 10 400lfm 0 0 70 80 90 Temperature C 100 70 80 90 100 Temperature C www.murata.com KDC_MTC2.F01 Page 11 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TEMPERATURE DERATING (Continued) MTC2S2403MC- 36Vin MTC2S2405MC- 36Vin 90 90 80 80 70 70 60 No Airflow 50 100lfm 40 200lfm 30 400lfm Load, % 100 Load, % 100 60 100lfm 40 200lfm 30 20 20 10 10 0 No Airflow 50 400lfm 0 70 80 90 100 70 Temperature C 80 90 100 Temperature C MTC2S2412MC- 36Vin 100 90 80 Load, % 70 60 No Airflow 50 100lfm 40 200lfm 30 400lfm 20 10 0 70 80 90 100 Temperature C www.murata.com KDC_MTC2.F01 Page 12 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters EMC FILTERING AND SPECTRA FILTERING The following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit A (orange line) and Quasi Peak Limit A (blue line) adherence limits. L DC C1 DC C2 Inductor Capacitor Recommended Part Number GRM31CR71E106KA12L & GCM21BR71C475KA73L Part Number L, μH SMD Through Hole C1, μF MTC2S0503MC 6.8 84682C 13R682C 10 & 4.7 MTC2S0505MC 4.7 84472C 13R472C 10 & 4.7 GRM31CR71E106KA12L & GCM21BR71C475KA73L Not required MTC2S0512MC MTC2S1203MC MTC2S1205MC MTC2S1212MC MTC2S2403MC MTC2S2405MC MTC2S2412MC 4.7 4.7 4.7 4.7 10 10 10 84472C 84472C 84472C 84472C 84103C 84103C 84103C 13R472C 13R472C 13R472C 13R472C 13R103C 13R103C 13R103C 10 10 10 10 10 10 10 GRM31CR71E106KA12L GRM31CR71E106KA12L GRM31CR71E106KA12L GRM31CR71E106KA12L GCM32EC71H106KA03L GCM32EC71H106KA03L GCM32EC71H106KA03L Not required Not required Not required Not required 47 68 47 80 80 70 70 60 60 50 50 40 30 20 20 10 10 1.00E+06 1.00E+07 0 1.00E+05 1.00E+08 80 80 70 70 60 60 50 50 40 30 20 20 10 10 Frequency (Hz) 1.00E+08 40 30 1.00E+07 1.00E+07 MTC2S1203MC dBuV dBuV MTC2S0512MC 1.00E+06 1.00E+06 Frequency (Hz) Frequency (Hz) 0 1.00E+05 DK11XEA470K86RBH01 DE11XRA680KN4AP01F DK11XEA470K86RBH01 40 30 0 1.00E+05 Not required MTC2S0505MC dBuV dBuV MTC2S0503MC Recommended Part Number C2, pF 1.00E+08 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata.com KDC_MTC2.F01 Page 13 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters EMC FILTERING AND SPECTRA (Continued) MTC2S1205MC MTC2S1212MC 80 80 70 70 60 60 50 dBuV dBuV 50 40 30 30 20 20 10 10 0 1.00E+05 40 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) Frequency (Hz) MTC2S2405MC 80 80 70 70 60 60 50 50 dBuV dBuV MTC2S2403MC 40 40 30 30 20 20 10 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) MTC2S2412MC 80 70 60 dBuV 50 40 30 20 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata.com KDC_MTC2.F01 Page 14 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters PACKAGE SPECIFICATIONS Mechanical Dimensions Pin Connections MTC2SXXXXMC XYYWW 14.99 [0.590] 14.22 [0.560] Pin Function 1 2 3 4 5 6 +Vin -Vout Trim +Vout Ctrl -Vin 0.89±0.30 [0.03±0.012] 9.91±0.30 [0.39±0.012] 14.22±0.30 [0.56±0.012] 12.19±0.30 [0.48±0.012] 11.25±0.50 [0.443±0.020] S x6 PINS 0.10 S SEATING PLANE 1.14±0.25 [0.045±0.010] 12.70±0.30 [0.500±0.012] 1 2 7.62±0.30 [0.300±0.012] 0.25±0.30 [0.010±0.012] 3 12.45±0.25 [0.490±0.010] 6 5 x6 PINS 1.02±0.05 [0.040±0.002] 0.25±0.30 [0.010±0.012] 4 x6 PINS 1.52±0.08 [0.060±0.003] All dimensions in mm(inches), Controlling dimension is mm. Tolerances (unless otherwise stated) ±0.15(0.006). Weight: 3.6g Components shown for reference only. Recommended Footprint Details x6 PLACES 1.37 [0.054] x6 PLACES 1.91 [0.075] 0.25 [0.010] 9.91 [0.390] 12.19 [0.480] RECOMMENDED ISOLATION BARRIER 0.25 [0.010] 1.52 [0.060] 12.45 [0.490] 7.62 [0.300] 1.52 [0.060] 12.70 [0.500] www.murata.com KDC_MTC2.F01 Page 15 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS Ø330 [13.000] MAX OR Ø177.8 [7.000] MAX REEL PACKAGING DETAILS [ 13.5 5.319 Ø12.8 Ø 5.043 ] LEADER SECTION 400 [15.748] MIN 38.4 [1.512] MAX # GOODS ENCLOSURE SECTION TRAILER SECTION 160 [6.299] MIN 100 [3.937] MIN 1.50 [0.059] MIN Ø20.20 [Ø0.795] MIN Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) Controlling dimension is mm # Measured at hub Carrier tape pockets shown are illustrative only - Refer to carrier tape diagram for actual pocket details. Reel Quantity: 7” - 30 or 13” - 150 TAPE OUTLINE DIMENSIONS 14.2±0.1 28.4 [1.118] 32.0±0.3 4.0 [0.157] 15.5±0.15 [0.610±0.006]# COVER TAPE 14.8±0.15 [0.583±0.006]# 12.2 [0.480] Tape & Reel specifications shall conform with current EIA-481 standard Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches) Controlling dimension is mm Components shall be orientated within the carrier tape as indicated # Measured on a plane 0.3mm above the bottom pocket 28.0 [1.102] DIRECTION OF UNREELING www.murata.com KDC_MTC2.F01 Page 16 of 17 MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to: • Aircraft equipment • Aerospace equipment • Undersea equipment • Power plant control equipment • Medical equipment • Transportation equipment (automobiles, trains, ships, etc.) • Traffic signal equipment • Disaster prevention / crime prevention equipment • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2022 Murata Power Solutions (Milton Keynes) Ltd. www.murata.com KDC_MTC2.F01 Page 17 of 17
MTC2S1212MC-R13 价格&库存

很抱歉,暂时无法提供与“MTC2S1212MC-R13”相匹配的价格&库存,您可以联系我们找货

免费人工找货