MTC2 Series
www.murata.com
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
FEATURES
UL60950 recognised for reinforced
insulation
ANSI/AAMI ES60601-1, 1 MOPP/ 2 MOOPs
recognised4
3kVAC isolation test voltage ‘Hi Pot Test’
Continuous short circuit protection
Output voltage trim
Remote on/off pin
No electrolytic capacitors
Operation up to 105°C (with derating)
2:1 input range
PRODUCT OVERVIEW
The MTC2 series of miniature surface mount
DC-DC converters offers a single output voltage
from input voltage ranges of 4.5-9V, 9-18V and
18-36V. The MTC2 series regulated output voltage
is adjustable by ±10% and a remote on/off pin is
also included for application power saving.
The MTC2 ideally suited to applications which
include medical. Industrial, telecommunications,
battery powered systems, and process automation.
Nom.
V
Rated Input
Current
Order Code
Output
Current
1
Output
Voltage
SELECTION GUIDE
V
mA
mA
Min.
%
Typ.
%
5
5
5
12
12
12
24
24
24
3.3
5
12
3.3
5
12
3.3
5
12
606
400
167
606
400
167
606
400
167
550
530
510
210
210
200
110
100
100
70
71
74
76
77
81
75
76
78
73
76
78.5
78.5
80
83.5
78.5
79.5
81.5
Input
Voltage
MTC2S0503MC3
MTC2S0505MC3
MTC2S0512MC3
MTC2S1203MC
MTC2S1205MC
MTC2S1212MC
MTC2S2403MC
MTC2S2405MC
MTC2S2412MC
Efficiency
Ripple and
Noise
Typ. Max.
mVp/p mVp/p
75
90
75
40
45
45
55
35
50
120
120
120
50
60
60
75
55
70
MTTF2
MIL.
kHrs
Tel.
kHrs
1270
1287
1170
1085
1067
1067
946
854
964
2371
2670
2106
2704
3260
3004
2540
2275
2424
INPUT CHARACTERISTICS
Parameter
Voltage range
Input reflected ripple
current
Conditions
Min.
Typ.
Max.
Units
5V input types
12V input types
24V input types
5V input types
All other variants
4.5
9
18
5
12
24
20
4
9
18
36
V
Typ.
Max.
mA p-p
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Isolation capacitance
Resistance
UL60950-1
Safety
ANSI/AAMI
Standard
ES60601-1
Conditions
Min.
Production tested for 1 second
Qualification tested for 1 minute
All variants
Viso = 1kVDC
Reinforced
Creepage and clearance 5mm
1 MOPP/2 MOOP
3000
3000
Units
VAC
20
pF
GΩ
1
250
250
VAC
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Rated power
All output types
Minimal load to meet datasheet specification
5V input types
Voltage set point accuracy
All other input types
Line regulation
Low line to high line
Load regulation
All output types
Typ.
Max.
2
10
-2.5
0503, 0505 & 0512
All other variants
0503
0505 & 0512
All other variants
Units
W
%
±0.05
±0.1
±0.05
2
±2
±0.2
±0.5
±0.2
±0.2
±0.5
%
%
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
MTC2SXXXXMC-R7 (30 pieces per reel), or MTC2SXXXXMC-R13 (150 pieces per reel)
2. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load.
3. MTC2S05xxMC variants are currently pending recognition to UL62368-1 as UL60950 is superseded by UL62638.
4. ANSI/AAMI ES60601-1 recognition is currently pending for MTC2S05xxMC.
For full details go to
https://www.murata.com/englobal/products/power/rohs
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata.com
KDC_MTC2.F01 Page 1 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
OUTPUT CHARACTERISTICS (Continued)
Parameter
Conditions
Peak deviation (25-75% & 75-25%
swing)
Min.
Typ.
±8
12V output types
±2
0503
±4
0505
±4.5
0512
±1.5
1205
±6
2405
Transient response
Settling time (1% Vout Nom.)
Max.
3.3V output types
Units
%Vout
±5
0503
420
0505
1000
0512
180
1203
45
1205
80
1212
60
2403
55
2405
75
2412
100
μs
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Remote on/off pin
Conditions
Min.
0503
0505
0512
1203
1205, 1212
2403
2405
2412
Module on, pin unconnected or open collector floating
3.3V output types
Module off (refer to application notes)
5V & 12V output types
5V input types
1203, 1205
1212
2403, 2405
2412
Typ.
Max.
135
115
140
285
260
185
225
240
Units
kHz
3
2
0.25
1.4
1.5
3.9
4.2
V
mW
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Operation
Storage
Case temperature above ambient
All output types (see derating curves)
-40
-50
100% Load, Nom VIN, Still Air
Typ.
Max.
Units
105
125
°C
22
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Remote on/off pin input voltage1
Input voltage, MTC2 5V input types
Input voltage, MTC2 12V input types
Input voltage, MTC2 24V input types
Continuous
12V
15V
25V
40V
1. Provided that external control circuit is the same as application note on page 5.
www.murata.com
KDC_MTC2.F01 Page 2 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MTC2 series of DC-DC converters are all 100% production tested at 3kVAC for 1 second and have been qualification tested at 3kVAC for 1
minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MTC2 series has been recognised by Underwriters Laboratory to 250Vrms for Reinforced Insulation.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
SAFETY APPROVAL
ANSI/AAMI ES60601-1
The MTC2 series has been recognised by Underwriters Laboratory (UL) to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of
Operator Protection) based upon a working voltage of 250 Vrms max., between Primary and Secondary. The MTC2S05xxMC variants are currently pending recognition.
File number E202895 applies.
UL 60950
The MTC2 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250 Vrms with a maximum measured product
operating temperature of 105°C. File number E151252 applies.
Creepage and clearance 5 mm.
FUSING
The MTC2 Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below.
Input Voltage, 5V: 0.91A (Fuse value is pending Underwriters Laboratory (UL) confirmation.)
Input Voltage, 12V: 0.75A
Input Voltage, 24V: 0.5A
All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with Pb-Free soldering systems and is also backward compatible with Sn/Pb soldering systems.
The MTC2 series has a process, moisture, and reflow sensitivity classification of MSL2 PSL R7F as defined in J-STD-020
and J-STD-075. This translates to: MSL2 = 1 year floor life, PSL R7F = Peak reflow temperature 245°C with a limitation
on the time above liquidus (217°C) which for this series is 90 sec max. Please refer to application notes for further
information. The pin termination finish on this product series is Gold with Nickel Pre-plate.
PART NUMBER STRUCTURE
MTC 2 S XX XX M C -RXX
Series name
Packaging code
Power rating
R7 - 7 inch reel
R13 - 13 inch reel
Output type
RoHS compliant
S - Single
D - Dual
Input voltage
Package type
S - SIP
D - DIP
M - Surface mount
Z - ZIP
Output voltage
www.murata.com
KDC_MTC2.F01 Page 3 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
ENVIRONMENTAL VALIDATION TESTING
The following tests have been conducted on this product series, please contact Murata if further information about the tests is required.
Test
Standard
Condition
Temperature cycling
MIL-STD-883 1010, Condition B
10 cycles between two chambers set to achieve -55°C and +125°C.The dwell time shall not be less than
10min and the load shall reach the specified temperature in 15min.
HAST (biased)
JEDEC JESD22-A110
96Hrs +2/-0Hrs at 130°C ± 2°C, 85% ± 5% R.H.
High temperature
storage life
JEDEC JESD22-A103, Condition A
125°C +10/-0°C for ≥1000 hours
Vibration
BS EN 61373 with respect to BS EN
5 – 150Hz. Level at each axis – Vertical, Traverse and Longitudinal: 5.72m/s2 rms. 5 hours in each axis. Crest
60068-2-64, Test Fh Category 1 Class B factor: 3 Sigma. Device is secured via pins.
Shock
BS EN 61373: Category 1 Class B
Test is 30ms duration, 3 shocks in each sense of 3 mutually perpendicular axes (18 shocks total). Level at each
axis as follows: Vertical, Traverse and Longitudinal: 50m/s2. Device is secured via pins.
Solderability
IPC/ECA J-STD-002, Test A and A1
SnPb (Test A): For lead free solderability, 5 off Parts conditioned to a 48hour dry bake at 125°C followed by 4
hours at 155°C and 5 off Parts conditioned to 96hours at 125°C. All 10 Dipped in solder at 245°C ±5°C for 5
+0/-0.5 seconds.
Pb-free (Test A1): For leaded solderability, 5 off Parts conditioned to a 48hour dry bake at 125°C followed by 4
hours at 155°C and 5 off Parts conditioned to 96hours at 125°C. All 10 Dipped in solder at 255°C ±5°C for 5
+0/-0.5 seconds.
Solvent cleaning
Resistance to cleaning agents
Solvent – Novec 71IPA & Topklean EL-20A. Pulsed ultrasonic immersion 45°C- 65°C
Solvent resistance
MIL-STD-883, Method 2015
The parts and the bristle portion of the brush are immersed in Isopropanol for a minimum of 1 minute. The
parts are brushed 3 times, after the third time the parts are blown dry and inspected.
www.murata.com
KDC_MTC2.F01 Page 4 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
C2
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
R1
T1
R2
+
Y INPUT
Output
-
R LOAD
APPLICATION NOTES
Maximum Output Capacitance
Maximum output capacitance should not exceed:
Output Voltage
V
3.3
5
12
Maximum Load Capacitance
μF
470
470
220
Start-up times
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10uF (5V inputs), 470μF (3.3, 5V outputs) and 220μF (12V
outputs), are shown in the table below. The product series will start into the maximum output capacitance with increased start times.
Part No.
MTC2S0503MC
MTC2S0505MC
MTC2S0512MC
MTC2S1203MC
MTC2S1205MC
MTC2S1212MC
MTC2S2403MC
MTC2S2405MC
MTC2S2412MC
Start-up times
ms
12
20
37
3
10.5
31
7
12
21
Typical Wave Form:
www.murata.com
KDC_MTC2.F01 Page 5 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
APPLICATION NOTES (Continued)
Control Pin
The MTC2 converters have a shutdown feature which enables the user to disable the converter into a low power state. The control pin connects to the base of an internal
NPN transistor with the converter shut down when the transistor is turned on by an external applied voltage. The converter can also be shut down using a 5V TTL signal (the
unit is OFF for logic High and ON for logic LOW). If the control pin is left open (high impedance), the converter will run normally. A suitable application circuit is shown below.
Ω
VIN
MTC2S
R2
VC or
TTL
-VIN
R1
D1
CTRL
Q1
D1 (e.g. 1N4001) is necessary for correct operation of the MTC2 when the control
signal is LOW. The recommended drive current IB to shut down the MTC2 is 6mA to
15mA. The value of R1 can be derived as follows:
VC - VD1 - 0.6
R1 =
IB
For a switch input:
Calculate the value of R1 from the above equation given switch voltage Vc and chosen
current between 6 and 15mA.
For 5V TTL Signal:
Set R1 to be between 320Ω to 800Ω.
Output Voltage Adjustment
The MTC2 series has a trim capability which is located at pin 3, this allows the user to independently adjust the output voltages by ±10%. Adjustments to the output voltages
can be accomplished via a single fixed resistor as shown in Figures 1 and 2. A single fixed resistor can increase or decrease the output voltage depending on its connection.
Fixed resistors should have low temperature coefficient to minimize sensitivity to changes in temperature.
A single resistor connected from the TRIM pin (pin 3) to the +Vout (pin 4), will decrease the output voltage which is shown in figure 1.
A single resistor connected from the TRIM pin (pin 3) to the -Vout (pin 2) will increase the output voltage which is shown in figure 2.
TRIM DOWN
TRIM UP
Figure 1. Trim connections to decrease the output voltage
1
+Vin
-Vout
2
TRIM
3
Figure 2. Trim connections to increase the output voltage
1
-Vout
+Vin
2
RTRIM
6
-Vin
5
CTRL
3.3VoutRTRIM =
5VoutRTRIM =
12VoutRTRIM =
RTRIM
+Vout
18.64k x Vout - 52.3k
3.32 - Vout
33.2k x Vout - 141k
5 - Vout
24.4k x Vout - 181.388k
12.2087 - Vout
4
5Vin12VoutRTRIM =
30.4k x Vout - 194.723k
12.0744 - Vout
6
-Vin
5
CTRL
3.3VoutRTRIM =
5VoutRTRIM =
12VoutRTRIM =
TRIM
3
+Vout
4
14k x Vout - 52.3k
3.32 - Vout
5Vin12VoutRTRIM =
12.4k x Vout - 194.723k
12.0744 - Vout
23.2k x Vout - 141k
5 - Vout
12.4k x Vout - 181.388k
12.2087 - Vout
Accuracy of adjustment is subject to tolerances of resistors and factory adjusted output accuracy. Vout is equal to the desired output voltage.
www.murata.com
KDC_MTC2.F01 Page 6 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
EFFICIENCY VS LOAD
MTC2S0505MC
90
90
80
80
70
70
60
60
50
4.5Vin
5Vin
40
9Vin
Efficiency (%)
Efficiency (%)
MTC2S0503MC
50
5Vin
30
30
20
20
10
10
0
0
20
40
60
80
4.5Vin
40
9Vin
0
100
0
20
40
60
Load (%)
80
100
Load (%)
MTC2S0512MC
MTC2S1203MC
90
90
80
70
70
60
60
50
4.5Vin
5Vin
40
9Vin
Efficiency (%)
Efficiency (%)
80
30
50
9 Vin
12 Vin
40
18 Vin
30
20
20
10
10
0
0
20
40
60
80
100
0
0
Load (%)
10
20
30
50
Load (%)
60
70
80
90
100
MTC2S1212MC
90
90
80
80
70
70
60
60
50
9 Vin
12 Vin
40
18 Vin
Efficiency (%)
Efficiency (%)
MTC2S1205MC
40
50
9 Vin
18 Vin
30
30
20
20
10
10
0
12 Vin
40
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
0
10
20
30
40
50
Load (%)
60
70
80
90
100
www.murata.com
KDC_MTC2.F01 Page 7 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
EFFICIENCY VS LOAD
MTC2S2405MC
90
90
80
80
70
70
60
60
50
18 Vin
24 Vin
40
36 Vin
Efficiency (%)
Efficiency (%)
MTC2S2403MC
50
18 Vin
36 Vin
30
30
20
20
10
10
0
24 Vin
40
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
0
10
20
30
40
50
Load (%)
60
70
80
90
100
MTC2S2412MC
90
80
70
Efficiency (%)
60
50
18 Vin
24 Vin
40
36 Vin
30
20
10
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
www.murata.com
KDC_MTC2.F01 Page 8 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TEMPERATURE DERATING
MTC2S0503MC
MTC2S0505MC
100
100
90
90
80
80
70
70
60
4.5Vin
50
5Vin
9Vin
Load, %
Load, %
60
4.5Vin
40
40
30
30
20
20
10
10
0
5Vin
50
9Vin
0
70
75
80
85
90
95
100
105
70
75
80
85
Temperature, C
90
95
100
105
Temperature, C
MTC2S0512MC
MTC2S1203MC - 12Vin
100
90
90
80
80
70
70
60
Load, %
60
4.5Vin
50
5Vin
Load, %
100
No Airflow
50
100lfm
40
200lfm
9Vin
40
30
30
20
20
10
10
0
400lfm
70
80
0
70
75
80
85
90
95
100
Temperature, C
90
90
80
80
70
70
60
No Airflow
100lfm
40
200lfm
30
400lfm
60
No Airflow
50
100lfm
40
200lfm
30
20
20
10
10
0
100
MTC2S1212MC - 12Vin
100
Load, %
Load, %
MTC2S1205MC - 12Vin
100
50
90
Temperature C
105
400lfm
0
70
80
90
Temperature C
100
70
80
90
100
Temperature C
www.murata.com
KDC_MTC2.F01 Page 9 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TEMPERATURE DERATING
MTC2S2403MC - 24Vin
MTC2S2405MC - 24Vin
100
100
90
90
80
80
70
60
No Airflow
50
100lfm
40
200lfm
30
Load, %
Load, %
70
400lfm
60
No Airflow
50
100lfm
40
200lfm
30
20
400lfm
20
10
10
0
70
80
90
0
100
70
Temperature C
80
90
MTC2S2412MC - 24Vin
MTC2S1203MC - 9Vin
100
100
90
80
80
70
70
No Airflow
60
100lfm
50
200lfm
40
Load, %
Load, %
90
60
No Airflow
50
100lfm
40
200lfm
400lfm
30
30
20
20
10
10
400lfm
0
0
70
80
90
70
100
80
Temperature C
90
100
Temperature C
MTC2S1205MC - 9Vin
MTC2S1212MC - 9Vin
100
100
90
90
80
80
70
70
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
Load, %
Load, %
100
Temperature C
60
100lfm
40
200lfm
30
20
20
10
10
0
No Airflow
50
400lfm
0
70
80
90
Temperature C
100
70
80
90
100
Temperature C
www.murata.com
KDC_MTC2.F01 Page 10 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TEMPERATURE DERATING (Continued)
MTC2S2405MC - 18Vin
100
90
90
80
80
70
70
60
No Airflow
50
100lfm
40
Load, %
Load, %
MTC2S2403MC - 18Vin
100
200lfm
30
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
20
20
10
10
0
400lfm
0
70
80
90
100
70
Temperature C
80
90
MTC2S1203MC - 18Vin
100
100
90
90
80
80
70
70
60
No Airflow
50
100lfm
40
Load, %
Load, %
MTC2S2412MC - 18Vin
200lfm
30
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
20
20
10
10
0
400lfm
0
70
80
90
100
70
80
90
100
Temperature C
Temperature C
MTC2S1205MC- 18Vin
MTC2S1212MC- 18Vin
100
100
90
90
80
80
70
70
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
Load, %
Load, %
100
Temperature C
60
No Airflow
50
100lfm
40
200lfm
30
20
20
10
10
400lfm
0
0
70
80
90
Temperature C
100
70
80
90
100
Temperature C
www.murata.com
KDC_MTC2.F01 Page 11 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TEMPERATURE DERATING (Continued)
MTC2S2403MC- 36Vin
MTC2S2405MC- 36Vin
90
90
80
80
70
70
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
Load, %
100
Load, %
100
60
100lfm
40
200lfm
30
20
20
10
10
0
No Airflow
50
400lfm
0
70
80
90
100
70
Temperature C
80
90
100
Temperature C
MTC2S2412MC- 36Vin
100
90
80
Load, %
70
60
No Airflow
50
100lfm
40
200lfm
30
400lfm
20
10
0
70
80
90
100
Temperature C
www.murata.com
KDC_MTC2.F01 Page 12 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following
plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit A (orange line) and Quasi Peak Limit A (blue line) adherence limits.
L
DC
C1
DC
C2
Inductor
Capacitor
Recommended Part
Number
GRM31CR71E106KA12L &
GCM21BR71C475KA73L
Part Number
L, μH
SMD
Through Hole
C1, μF
MTC2S0503MC
6.8
84682C
13R682C
10 & 4.7
MTC2S0505MC
4.7
84472C
13R472C
10 & 4.7
GRM31CR71E106KA12L &
GCM21BR71C475KA73L
Not required
MTC2S0512MC
MTC2S1203MC
MTC2S1205MC
MTC2S1212MC
MTC2S2403MC
MTC2S2405MC
MTC2S2412MC
4.7
4.7
4.7
4.7
10
10
10
84472C
84472C
84472C
84472C
84103C
84103C
84103C
13R472C
13R472C
13R472C
13R472C
13R103C
13R103C
13R103C
10
10
10
10
10
10
10
GRM31CR71E106KA12L
GRM31CR71E106KA12L
GRM31CR71E106KA12L
GRM31CR71E106KA12L
GCM32EC71H106KA03L
GCM32EC71H106KA03L
GCM32EC71H106KA03L
Not required
Not required
Not required
Not required
47
68
47
80
80
70
70
60
60
50
50
40
30
20
20
10
10
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
80
80
70
70
60
60
50
50
40
30
20
20
10
10
Frequency (Hz)
1.00E+08
40
30
1.00E+07
1.00E+07
MTC2S1203MC
dBuV
dBuV
MTC2S0512MC
1.00E+06
1.00E+06
Frequency (Hz)
Frequency (Hz)
0
1.00E+05
DK11XEA470K86RBH01
DE11XRA680KN4AP01F
DK11XEA470K86RBH01
40
30
0
1.00E+05
Not required
MTC2S0505MC
dBuV
dBuV
MTC2S0503MC
Recommended Part
Number
C2, pF
1.00E+08
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_MTC2.F01 Page 13 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
EMC FILTERING AND SPECTRA (Continued)
MTC2S1205MC
MTC2S1212MC
80
80
70
70
60
60
50
dBuV
dBuV
50
40
30
30
20
20
10
10
0
1.00E+05
40
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
MTC2S2405MC
80
80
70
70
60
60
50
50
dBuV
dBuV
MTC2S2403MC
40
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
MTC2S2412MC
80
70
60
dBuV
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_MTC2.F01 Page 14 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
PACKAGE SPECIFICATIONS
Mechanical Dimensions
Pin Connections
MTC2SXXXXMC
XYYWW
14.99 [0.590]
14.22 [0.560]
Pin
Function
1
2
3
4
5
6
+Vin
-Vout
Trim
+Vout
Ctrl
-Vin
0.89±0.30 [0.03±0.012]
9.91±0.30 [0.39±0.012]
14.22±0.30 [0.56±0.012]
12.19±0.30 [0.48±0.012]
11.25±0.50 [0.443±0.020]
S
x6 PINS
0.10 S
SEATING PLANE
1.14±0.25 [0.045±0.010]
12.70±0.30 [0.500±0.012]
1
2
7.62±0.30 [0.300±0.012]
0.25±0.30 [0.010±0.012]
3
12.45±0.25 [0.490±0.010]
6
5
x6 PINS
1.02±0.05 [0.040±0.002]
0.25±0.30 [0.010±0.012]
4
x6 PINS
1.52±0.08 [0.060±0.003]
All dimensions in mm(inches), Controlling dimension is mm. Tolerances (unless otherwise stated) ±0.15(0.006).
Weight: 3.6g
Components shown for reference only.
Recommended Footprint Details
x6 PLACES
1.37 [0.054]
x6 PLACES
1.91 [0.075]
0.25 [0.010]
9.91 [0.390]
12.19 [0.480]
RECOMMENDED
ISOLATION BARRIER
0.25 [0.010]
1.52 [0.060]
12.45 [0.490]
7.62 [0.300]
1.52 [0.060]
12.70 [0.500]
www.murata.com
KDC_MTC2.F01 Page 15 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
Ø330 [13.000] MAX
OR
Ø177.8 [7.000] MAX
REEL PACKAGING DETAILS
[
13.5 5.319
Ø12.8 Ø 5.043
]
LEADER SECTION
400 [15.748] MIN
38.4 [1.512] MAX #
GOODS
ENCLOSURE
SECTION
TRAILER SECTION
160 [6.299] MIN
100 [3.937]
MIN
1.50 [0.059]
MIN
Ø20.20 [Ø0.795]
MIN
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches)
Controlling dimension is mm
# Measured at hub
Carrier tape pockets shown are
illustrative only - Refer to carrier tape
diagram for actual pocket details.
Reel Quantity: 7” - 30 or 13” - 150
TAPE OUTLINE DIMENSIONS
14.2±0.1
28.4 [1.118]
32.0±0.3
4.0 [0.157]
15.5±0.15 [0.610±0.006]#
COVER TAPE
14.8±0.15 [0.583±0.006]#
12.2 [0.480]
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches)
Controlling dimension is mm
Components shall be orientated within the carrier tape as indicated
# Measured on a plane 0.3mm above the bottom pocket
28.0 [1.102]
DIRECTION OF UNREELING
www.murata.com
KDC_MTC2.F01 Page 16 of 17
MTC2 Series
Isolated 2W SM 2:1 Input Single Output DC-DC Converters
DISCLAIMER
Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical
applications.
Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe
damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use.
These applications include but are not limited to:
•
Aircraft equipment
•
Aerospace equipment
•
Undersea equipment
•
Power plant control equipment
•
Medical equipment
•
Transportation equipment (automobiles, trains, ships, etc.)
•
Traffic signal equipment
•
Disaster prevention / crime prevention equipment
•
Data Processing equipment
Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The
suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and
liability of the buyer.
Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold
Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/
or life-critical applications.
Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: https://www.murata.com/en-eu/products/power/requirements
Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use
of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change
without notice.
© 2022 Murata Power Solutions (Milton Keynes) Ltd.
www.murata.com
KDC_MTC2.F01 Page 17 of 17