MTE1 Series
www.murata.com
Isolated 1W Single Output SM DC-DC Converters
Output Current
Input Current at
Rated Load (Typ.)
Efficiency (Min.)
Efficiency (Typ.)
Isolation
Capacitance
MTTF2
V
mA
mA
%
% mVp-p
%
%
pF
kHrs
MTE1S0305MC
MTE1S0505MC
MTE1S0506MC
MTE1S1205MC
MTE1S2405MC
3.3
5
5
12
24
5
5
6
5
5
200
200
167
200
200
363
239
236
97
50
8.5
6.5
6
5
4
11
8
7.5
7
5.5
24
20
20
19
20
79
79
81
81
79
82
82
84
84
83
16
22
24
24
21
2912
3041
3024
2707
2731
MTE1S0303MC
MTE1S0309MC
MTE1S0312MC
MTE1S0315MC
MTE1S0503MC
MTE1S0509MC
MTE1S0512MC
MTE1S0515MC
MTE1S1209MC
MTE1S1212MC
MTE1S1215MC
MTE1S1505MC
MTE1S1509MC
MTE1S1512MC
MTE1S1515MC
MTE1S2409MC
MTE1S2412MC
MTE1S2415MC
3.3
3.3
3.3
3.3
5
5
5
5
12
12
12
15
15
15
15
24
24
24
3.3
9
12
15
3.3
9
12
15
9
12
15
5
9
12
15
9
12
15
303
111
83
67
303
111
83
67
111
83
67
200
111
83
67
111
83
67
382
353
348
346
248
233
227
225
95
93
93
79
77
76
75
48
48
48
11
7
6.5
6
9
5
5
5
3
3
3
4
3
2.5
2.5
2.5
2
2
13.5
9
8
8
12
6.5
6.5
6.5
4.5
4.5
4
5.5
4
4
4
4
3.5
3.5
33
17
15
13
24
15
14
11
13
12
11
15
9
10
8
19
19
22
75
82
83
83
77
83
84
85
82
85
85
80
81
82
84
84
83
85
78
85
86
86
79
85
87
88
86
88
88
83
86
87
88
86
87
88
15
21
20
20
21
26
29
33
29
43
40
25
38
45
57
31
39
46
3083 NXE1S0303MC-R7
2759
NTE0309MC
2573 Contact Murata
2265 Contact Murata
3080
NTE0503MC
2875
NTE0509MC
2658
NTE0512MC
2336
NTE0515MC
2597
NTE1209MC
2422
NTE1212MC
2169
NTE1215MC
2444 Contact Murata
2366 Contact Murata
2196 Contact Murata
2001 Contact Murata
2698 Contact Murata
2488 Contact Murata
2392 NXJ2S2415MC-R7
FEATURES
ES
Single isolated output
1kVDC isolation “Hi Pot Test”
Typical efficiency 86%
Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 60950 recognised
3.3V, 5V, 12V & 24V inputs
5V output
Internal SMD construction
Toroidal magnetics
PRODUCT OVERVIEW
The MTE1 series is a new range of surface mount,
high performance 1W DC-DC converters. The
MTE1 series is the new high performance version
of our 1W NTE series, the MTE1 series is more
efficient and offers improved regulation performance. The MTE1 series offers 1W of available
output power over the full industrial temperature
range of -40ºC to 85ºC.
The MTE1 series has a MSL rating 1, and is
compatible with a peak reflow solder temperature
of 245˚C as per J-STD-020D.1.
Recommended
Alternative
Output Voltage
V
Order Code1
Load Regulation
(Typ. )
Load Regulation
(Max)
Output Ripple
& Noise (Typ.)
Nominal Input
Voltage
SELECTION GUIDE
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Voltage range
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 15V input types
Continuous operation, 24V input types
2.97
4.5
10.8
13.5
21.6
3.3
5.0
12.0
15.0
24
5
3.63
5.5
13.2
16.5
26.4
15
mA p-p
Typ.
Max.
Units
1.0
W
1.1
25
1.2
70
%/%
mV p-p
Typ.
Max.
Units
Reflected ripple current
Units
V
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated power
Voltage set point accuracy
Line regulation
Ripple and noise
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
BW=DC to 20MHz
Min.
ISOLATION CHARACTERISTICS
For full details go to
https://www.murata.com/englobal/products/power/rohs
Parameter
Conditions
Min.
Isolation voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
20
VDC
GΩ
1. If components are required in tape and reel format suffix order code with -R, e.g. MTE0505MC-R.
2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata.com
KDC_MTE1.E01 Page 1 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
All output types
Min.
Typ.
Max.
80
Units
Hz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
Case temperature rise above ambient
Cooling
All output types
-40
-50
All output types
Free air convection
Typ.
Max.
Units
°C
12.5
85
130
20
ABSOLUTE MAXIMUM RATINGS
Input voltage VIN, MTE03 types
Input voltage VIN, MTE05 types
Input voltage VIN, MTE12 types
Input voltage VIN, MTE15 types
Input voltage VIN, MTE24 types
5.5V
7V
15V
18V
28V
www.murata.com
KDC_MTE1.E01 Page 2 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied
for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MTE1 series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MTE1 has been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak,
or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be
regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety
standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MTE1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MTE1 series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature for 3.3V & 5V input models of
60°C and for 12V, 15V and 24V models of 85°C. File number E151252 applies. The MTE1 Series of converters are not internally fused so to meet the requirements of UL 60950
an anti-surge input line fuse should always be used with ratings as defined below.
MTE1S03xxxC: 1A
MTE1S05xxxC: 0.7A
MTE1S12xxxC: 0.2A
MTE1S15xxxC: 0.2A
MTE1S24xxxC: 0.16A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems as per J-STD-020D.1. Please refer to application notes for further
information. The pin termination finish on this product series is Matte Tin over Nickel Preplate. The series is backward
compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1.
Samples of the product series were tested in accordance with the conditioning described for MSL level 1 in
IDC/J-STD-020D.1. The product series passed electrical tests and visual inspection criteria.
For further information, please visit: www.murata-ps.com/rohs
TEMPERATURE DERATING GRAPH
Output Power (W)
1.5
1.0
0.5
0
-40
85°C
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
www.murata.com
KDC_MTE1.E01 Page 3 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
PART NUMBER STRUCTURE
MTE 1 S XX XX M C
Series name
RoHS compliant
Power rating
Package type
S - Single
D - Dual
S - SIP
D - DIP
M - Surface mount
Z - ZIP
Input voltage
Output voltage
Output type
www.murata.com
KDC_MTE1.E01 Page 4 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
APPLICATION NOTES
Advisory Notes
Minimum Load
The MTE series is not hermetically sealed, customers should ensure that parts are
fully dried before input power application.
The minimum load to meet datasheet specification is 10% of the full rated load
across the specified input voltage range. Lower than 10% minimum loading will
result in an increase in output voltage, which may rise to typically double the
specified output voltage if the output load falls to less than 5%.w
The MTE has been tested to the following standards, which should not be exceeded for shock and vibration:
BS EN 60068-2-64:2008 (Vibration Broadband Random)
BS EN 60068-2-27:2009 (Mechanical Shock)
Capacitive Loading & Start Up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The
product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
MTE1S0303MC
MTE1S0305MC
MTE1S0309MC
MTE1S0312MC
MTE1S0315MC
MTE1S0503MC
MTE1S0505MC
MTE1S0506MC
Start-up time
μs
140
270
830
1250
2330
130
170
210
Start-up time
μs
355
670
1410
175
390
800
1360
130
MTE1S0509MC
MTE1S0512MC
MTE1S0515MC
MTE1S1205MC
MTE1S1209MC
MTE1S1212MC
MTE1S1215MC
MTE1S1505MC
MTE1S1509MC
MTE1S1512MC
MTE1S1515MC
MTE1S2405MC
MTE1S2409MC
MTE1S2412MC
MTE1S2415MC
Start-up time
μs
310
440
770
110
230
400
590
Typical Start-Up Wave Form
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the
rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be
as low as possible, ceramic types are recommended. The voltage rating should
be at least twice (except for 15V output), the rated output voltage of the DC-DC
converter.
Inductor: The rated current of the inductor should not be less than that of the
output of the DC-DC converter. At the rated current, the DC resistance of the
inductor should be such that the voltage drop across the inductor is 20MHz.
L
Power
Source
DC
C
DC
Load
MTE1S0303MC
MTE1S0305MC
MTE1S0309MC
MTE1S0312MC
MTE1S0315MC
MTE1S0503MC
MTE1S0505MC
MTE1S0506MC
MTE1S0509MC
MTE1S0512MC
MTE1S0515MC
MTE1S1205MC
MTE1S1209MC
MTE1S1212MC
MTE1S1215MC
MTE1S1505MC
MTE1S1509MC
MTE1S1512MC
MTE1S1515MC
MTE1S2405MC
MTE1S2409MC
MTE1S2412MC
MTE1S2415MC
L, μH
4.7
10
22
47
47
4.7
10
22
22
47
47
10
22
47
47
10
22
47
47
10
22
47
47
Inductor
SMD
82472C
82103C
82223C
82473C
82473C
82472C
82103C
82223C
82223C
82473C
82473C
82103C
82223C
82473C
82473C
82103C
82223C
82473C
82473C
82103C
82223C
82473C
82473C
Through Hole
11R472C
11R103C
11R223C
11R473C
11R473C
11R472C
11R103C
11R223C
11R223C
11R473C
11R473C
11R103C
11R223C
11R473C
11R473C
11R223C
11R103C
11R473C
11R473C
11R103C
11R223C
11R473C
11R473C
Capacitor
C, μF
10
4.7
2.2
1
1
10
4.7
2.2
2.2
1
1
4.7
2.2
1
1
4.7
2.2
1
1
4.7
2.2
1
1
www.murata.com
KDC_MTE1.E01 Page 5 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
TOLERANCE ENVELOPES
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
0303, 0503
0305,0309
8%
13%
3%
-5%
10
25
50
75
Output Load Current (%)
Output Voltage
Output Voltage
5%
5%
2%
-4%
100
10
0312, 0315, 0505, 0506, 0509
25
50
75
Output Load Current (%)
100
1209, 1212, 1215, 15XX, 2409, 2412, 2415
3%
2%
-4%
10
25
50
75
Output Load Current (%)
100
Output Voltage
Output Voltage
7%
4%
1%
0%
-3%
10
25
50
75
Output Load Current (%)
100
0512, 0515, 1205,2405
Output Voltage
5%
1%
0%
-4%
10
25
50
75
Output Load Current (%)
100
www.murata.com
KDC_MTE1.E01 Page 6 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
EFFICIENCY VS LOAD
5V Input
90
70
70
Efficiency (%)
Efficiency (%)
3.3V Input
90
50
MTE1S0303MC
MTE1S0305MC
30
MTE1S0309MC
MTE1S0503MC
50
MTE1S0505MC
MTE1S0509MC
30
MTE1S0512MC
MTE1S0312MC
0
MTE1S0515MC
MTE1S0315MC
10
20
40
60
80
MTE1S0506MC
10
100
0
20
40
Load (%)
12V Input
90
70
70
50
MTE1S1205MC
30
MTE1S1209MC
MTE1S1505MC
30
MTE1S1509MC
MTE1S1512MC
MTE1S1215MC
10
20
40
100
50
MTE1S1212MC
0
80
15V Input
90
Efficiency (%)
Efficiency (%)
60
Load (%)
60
Load (%)
80
MTE1S1515MC
10
100
0
20
40
60
Load (%)
80
100
24V Input
90
Efficiency (%)
70
50
MTE1S2405MC
30
MTE1S2409MC
MTE1S2412MC
MTE1S2415MC
10
0
20
40
60
Load (%)
80
100
www.murata.com
KDC_MTE1.E01 Page 7 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
EMC FILTERING AND SPECTRA
FILTERING
A 22uF (100uF for the MTE1S2405MC), input capacitor is required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots.
MTE1S0305MC
80
80
70
70
60
60
50
50
dBuV
dBuV
MTE1S0303MC
40
40
30
30
20
20
10
0
1.00E+05
10
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
1.00E+06
Frequency (Hz)
MTE1S0309MC
80
70
70
60
60
50
dBuV
dBuV
50
40
40
30
30
20
20
10
10
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
1.00E+06
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
1.00E+07
Frequency (Hz)
1.00E+08
MTE1S0503MC
dBuV
dBuV
MTE1S0315MC
1.00E+06
1.00E+07
Frequency (Hz)
Frequency (Hz)
0
1.00E+05
1.00E+08
MTE1S0312MC
80
0
1.00E+05
1.00E+07
Frequency (Hz)
1.00E+08
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_MTE1.E01 Page 8 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
EMC FILTERING AND SPECTRA (Continued)
MTE1S0506MC
80
80
70
70
60
60
50
50
dBuV
dBuV
MTE1S0505MC
40
40
30
30
20
20
10
0
1.00E+05
10
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
1.00E+06
Frequency (Hz)
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
1.00E+06
1.00E+08
MTE1S0512MC
dBuV
dBuV
MTE1S0509MC
0
1.00E+05
1.00E+07
Frequency (Hz)
1.00E+07
0
1.00E+05
1.00E+08
1.00E+06
Frequency (Hz)
1.00E+07
1.00E+08
Frequency (Hz)
MTE1S0515MC
MTE1S1205MC
80
80
70
70
60
60
50
dBuV
dBuV
50
40
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
0
1.00E+05
Frequency (Hz)
1.00E+06
1.00E+07
1.00E+08
1.00E+07
1.00E+08
Frequency (Hz)
MTE1S1209MC
MTE1S1212MC
80
80
70
70
60
60
50
dBuV
dBuV
50
40
30
30
20
20
10
0
1.00E+05
40
10
1.00E+06
1.00E+07
Frequency (Hz)
1.00E+08
0
1.00E+05
1.00E+06
Frequency (Hz)
www.murata.com
KDC_MTE1.E01 Page 9 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
EMC FILTERING AND SPECTRA (Continued)
MTE1S1215MC
MTE1S1505MC
80
80
70
70
60
60
50
dBuV
dBuV
50
40
30
30
20
20
10
0
1.00E+05
40
10
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
Frequency (Hz)
1.00E+06
1.00E+07
1.00E+08
1.00E+07
1.00E+08
1.00E+07
1.00E+08
1.00E+07
1.00E+08
Frequency (Hz)
MTE1S1509MC
MTE1S1512MC
80
80
70
70
60
60
50
dBuV
dBuV
50
40
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
Frequency (Hz)
Frequency (Hz)
MTE1S2405MC
80
80
70
70
60
60
50
50
dBuV
dBuV
MTE1S1515MC
40
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+06
1.00E+07
0
1.00E+05
1.00E+08
1.00E+06
Frequency (Hz)
Frequency (Hz)
MTE1S2412MC
80
80
70
70
60
60
50
50
dBuV
dBuV
MTE1S2409MC
40
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
Frequency (Hz)
1.00E+08
0
1.00E+05
1.00E+06
Frequency (Hz)
www.murata.com
KDC_MTE1.E01 Page 10 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
EMC FILTERING AND SPECTRA (Continued)
MTE1S2415MC
80
70
60
dBuV
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_MTE1.E01 Page 11 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
PACKAGE SPECIFICATIONS
Mechanical Dimensions
Pin Connections
MTEXXXXXMC
XYWW
All dimensions in mm ±0.05mm (inches ±0.002). All pins on a 2.54 (0.1) pitch and within ± 0.25 (0.01) of true.
Pin
Function
1
3
7
8
14
-VIN
+VIN
-VOUT
+VOUT
NA
NA - Not available for electrical connection.
Weight: 1.1g Typ.
Tube Outline Dimensions
Recommended Footprint Details
7.62 [0.300]
9.40 [0.370]
2.54 [0.100]
All pins on a 2.54mm pitch.
1.00 [0.039]
14.85 (0.59)
11.40 (0.45)
2.30 [0.091]
9.05 (0.36)
Unless otherwise stated all dimensions in mm±0.5mm (inches ±0.02).
Tube length : 475±2.0 (18.70±0.07).
Tube Quantity: 30
www.murata.com
KDC_MTE1.E01 Page 12 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
TAPE OUTLINE DIMENSIONS
330±2.0
(12.99±0.08)
13.25
(0.52)
0.60 (0.02) Max.
Ø90 (3.54)
+0.004 (+0.10)
-0.00 (-0.00)
DIRECTION OF UNREELING
1.50 (Ø0.06)
2.00
(0.08)
13.00±0.5
Ø (0.51±0.02)
16.00 (0.63)
11.50
(0.45)
4.00
(0.16)
1.75(0.07)
11.50
(0.45)
8.10
(0.32)
24.00±0.30
(0.94±0.01)
REEL PACKAGING DETAILS
GOODS ENCLOSURE
SECTION
MTE1S0303MC
XYYWW
MTE1S0303MC
XYYWW
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
MTE1S0303MC
XYYWW
TRAILER SECTION
160 (6.30) MIN
CARRIER TAPE START
100 (3.94) MIN
LEADER SECTION
400 (15.75) MIN
Reel Quantity: 500
www.murata.com
KDC_MTE1.E01 Page 13 of 14
MTE1 Series
Isolated 1W Single Output SM DC-DC Converters
DISCLAIMER
Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical
applications.
Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe
damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use.
These applications include but are not limited to:
•
Aircraft equipment
•
Aerospace equipment
•
Undersea equipment
•
Power plant control equipment
•
Medical equipment
•
Transportation equipment ( automobiles, trains, ships, etc.)
•
Traffic signal equipment
•
Disaster prevention / crime prevention equipment
•
Data Processing equipment
Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The
suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and
liability of the buyer.
Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold
Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/
or life-critical applications.
Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: https://www.murata.com/en-eu/products/power/requirements
Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use
of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change
without notice.
© 2022 Murata Power Solutions (Milton Keynes) Ltd.
www.murata.com
KDC_MTE1.E01 Page 14 of 14