NMR100PC

NMR100PC

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    -

  • 描述:

    Module DC-DC 5VIN 1-OUT 5V 0.2A 1W 4-Pin SIP Module Tube

  • 数据手册
  • 价格&库存
NMR100PC 数据手册
NMR Series www.murata.com Isolated 1W Single Output DC-DC Converters NMR100C NMR101C NMR102C NMR106C NMR107C NMR118C NMR120C 5 5 5 12 12 24 24 5 12 15 5 12 5 15 200 83 67 200 83 200 67 290 260 253 121 110 60 52 NMR100PC 5 5 200 12 14 15 30 69 28 1847 6.9 7.7 4.6 10 77 33 981 6.5 7.5 4.3 10 79 40 667 12.5 13.4 5.3 10 69 36 1485 6.9 7.7 5 10 76 58 869 6.8 10 8 15 70 61 1253 2.5 3.5 8 15 80 122 566 Short Circuit Protection Option 255 10 12 10 25 74 76.5 22 3095 61060 NMR108C NMR119C 12 24 15 12 67 83 110 53 6.5 2.8 7.5 4 4 7 10 15 76 78 56 98 613 784 MER1S1215SC MER1S2412SC „ No electrolytic or tantalum capacitors NMR112C NMR113C NMR114C 15 15 15 5 12 15 200 83 67 93 85 84 8.1 3.3 2.8 10 4 3.5 14 12 14 20 15 20 69 77 78 27 58 67 2110 1790 1560 MER1S1505SC Contact Murata MER1S1515SC DESCRIPTION INPUT CHARACTERISTICS The NMR series of industrial temperature range DC-DC converters are the standard building blocks for on-board distributed power systems. They are ideally suited for providing single rail supplies on primarily digital boards with the added benefit of galvanic isolation to reduce switching noise. Surface mount technology and advanced packaging materials produce rugged reliable performance over an extended temperature range from -40ºC to 85ºC. For the NMR100PC protection is continuous and auto-resetting on removal of the short circuit. Parameter FEATURES „ Short circuit protection option „ UL 60950 recognised „ 1kVDC isolation ‘Hi Pot Test’ „ Wide temperature performance at full 1 watt load, –40°C to 85°C Efficiency (Typ) Efficiency (Min) % mV p-p Typ. Max. Typ. Max. % pF MIL. Tel. kHrs Recommended Alternative mA MTTF1 mA Isolation Capacitance V Ripple & Noise3 Input Current at Rated Load V Order Code Nominal Input Voltage Output Voltage Output Current Load Regulation SELECTION GUIDE „ Industry standard pinout „ 5V, 12V & 24V inputs „ 5V, 12V & 15V outputs „ Fully encapsulated with toroidal magnetics „ Custom solutions available Voltage range Input short circuit current Input reflected ripple current Conditions Min. Typ. Max. Units Continuous operation, 5V input types Continuous operation, 12V input types Continuous operation, 15V input types Continuous operation, 24V input types Short circuit variants Short circuit types 5V & 12V input types 15V & 24V input types 4.5 10.8 13.5 21.6 5 12 15 24 95 2 1.6 5 5.5 13.2 16.5 26.4 V 15 2 10 mA p-p Typ. Max. Units 1.0 W 1.15 1.0 1.2 1.2 %/% Typ. Max. Units mA OUTPUT CHARACTERISTICS Parameter Conditions Rated Power2 Voltage Set Point Accuracy TA=-40°C to 85°C, See derating graph See tolerance envelope High VIN to low VIN ; Short circuit types High VIN to low VIN ; All other output types Line regulation Min. ISOLATION CHARACTERISTICS For full details go to https://www.murata.com/englobal/products/power/rohs Parameter Conditions Min. Isolation voltage Resistance Flash tested for 1 second Viso=1000VDC 1000 10 VDC GΩ 1. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load. 2. See derating graph. 3. See ripple & noise characterisation method. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata.com KDC_NMR.K01 Page 1 of 12 NMR Series Isolated 1W Single Output DC-DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds Wave Solder Input voltage VIN, NMR100C, NMR101C, NMR102C Input voltage VIN, NMR106C, NMR107C, NMR108C Input voltage VIN, NMR112C, NMR113C, NMR114C Input voltage VIN, NMR118C, NMR119C, NMR120C 260°C Wave Solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Please refer to application notes for further information. 7V 15V 18V 28V GENERAL CHARACTERISTICS Parameter Conditions Switching frequency 5V input types 12V input types 15V input types 24V input types Short circuit types Min. Typ. Max. 110 160 90 80 97 Units kHz TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage All output types -40 -50 Case Temperature above ambient Cooling 5V output types All other output types Short circuit types Free air convection Typ. Max. Units 85 130 33 28 18 °C www.murata.com KDC_NMR.K01 Page 2 of 12 NMR Series Isolated 1W Single Output DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NMR series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The NMR is recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NMR series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL UL60950 The NMR series is recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum still air ambient temperature of 100°C as measured at any point on the case of the unit (hotspot). FUSING The NMR Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below. Input Voltage, 5V 0.5A Input Voltage, 12V 0.25A Input Voltage, 24V 0.12A All fuses should be UL recognised, 125V rated. File number E151252 applies. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. Please refer to application notes for further information. The pin termination finish on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit https://www.murata.com/en-global/products/power/rohs www.murata.com KDC_NMR.K01 Page 3 of 12 NMR Series Isolated 1W Single Output DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. C2 Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - R1 + T1 R2 Y INPUT Output - R LOAD APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Typical Start-Up Wave Form NMR100C NMR101C NMR102C NMR106C NMR107C NMR108C Start-up time μs 2301 5570 8289 783 4770 4850 NMR112C NMR113C NMR114C NMR118C NMR119C NMR120C NMR100PC Start-up time μs 744 1908 6620 671 5335 6370 360 www.murata.com KDC_NMR.K01 Page 4 of 12 NMR Series Isolated 1W Single Output DC-DC Converters APPLICATION NOTES (Continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC-DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC-DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is 20MHz. L DC Power Source NMR100C NMR101C NMR102C NMR106C NMR107C NMR108C NMR112C NMR113C NMR114C NMR118C NMR119C NMR120C NMR100PC L, μH 10 47 47 10 47 47 10 47 47 10 47 47 22 Inductor SMD 82103C 82473C 82473C 82103C 82473C 82473C 82103C 82473C 82473C 82103C 82473C 82473C 82223C C Load DC Through Hole 11R103C 11R473C 11R473C 11R103C 11R473C 11R473C 11R103C 11R473C 11R473C 11R103C 11R473C 11R473C 11R223C Capacitor C, μF 4.7 1 1 4.7 1 1 4.7 1 1 4.7 1 1 1 www.murata.com KDC_NMR.K01 Page 5 of 12 NMR Series Isolated 1W Single Output DC-DC Converters TOLERANCE ENVELOPES The voltage tolerance envelopes show typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading and set point accuracy. NMR118 NMR113, NMR114, NMR119, NMR120 2% 0% Output Voltage Output Voltage 7% 4% 1% 0% -3% -5% 10 25 50 Output Load Current (%) 100 75 10 25 All other output types 50 Output Load Current (%) 100 75 Short cicuit types 10% 10% 0% Output Voltage Output Voltage 5% 2.5% 0% -6% -7.5% 10 25 50 Output Load Current (%) 10 100 75 25 50 Output Load Current (%) 75 100 TEMPERATURE DERATING GRAPHS All other types. 1 Output Power (W) Output Power (W) Short Circuit types. 85°C Safe Operating Area 0 -40 100 50 0 Ambient Temperature (°C) 150 85°C 1 Safe Operating Area 120°C 0 -40 100 50 0 Ambient Temperature (°C) 150 www.murata.com KDC_NMR.K01 Page 6 of 12 NMR Series Isolated 1W Single Output DC-DC Converters EFFICIENCY VS LOAD NMR100C NMR101C NMR102 NMR106C NMR107C NMR108C www.murata.com KDC_NMR.K01 Page 7 of 12 NMR Series Isolated 1W Single Output DC-DC Converters EFFICIENCY VS LOAD (Continued) NMR118C NMR119C NMR120C NMR100PC 90 80 70 Efficiency (%) 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) www.murata.com KDC_NMR.K01 Page 8 of 12 NMR Series Isolated 1W Single Output DC-DC Converters EMC FILTERING AND SPECTRA FILTERING The following filter circuit and filter table shows the input filters typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots. The following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits. L DC C DC C Ceramic capacitor Inductor Capacitor Part Number L, μH SMD Through Hole C, μF NMR100C NMR101C NMR102C NMR106C NMR107C NMR108C NMR118C NMR119C NMR120C NMR100PC 10 82103C 13R103C 10 NMR100C NMR101C NMR102C NMR106C www.murata.com KDC_NMR.K01 Page 9 of 12 NMR Series Isolated 1W Single Output DC-DC Converters EMC FILTERING AND SPECTRA (Continued) NMR107C NMR108C NMR118C NMR119C NMR120C NMR100PC 80 70 60 dBuV 50 40 30 20 10 0 1.00E+05 1.00E+06 1.00E+07 1.00E+08 Frequency (Hz) www.murata.com KDC_NMR.K01 Page 10 of 12 NMR Series Isolated 1W Single Output DC-DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS - 7 PIN SIP 7 Pin SIP Package 19.50±0.25 [0.768±0.010] 6.00±0.25 [0.236±0.010] 10.00±0.25 [0.394±0.010] Pin Function 1 2 4 6 +VIN -VIN -VOUT +VOUT S 4.10±0.5 [0.161±0.020] 0.50±0.05 [0.020±0.002] 5.08 [0.200] 0.25±0.05 [0.010±0.002] 1 2 (1.13 [0.044]) 4 6 2.54 [0.100] (1.93 [0.076]) 12.70 [0.500] All dimensions in mm (inches) Controlling dimension is mm. All pins on a 2.54 (0.100) pitch and within ±0.1 (0.004) of true position from pin 1 at seating plane ‘S’ For SIP products, from date code D2224 onwards, products have an embossed logo on the top of the case. Prior to this date, SIP products have flat surface finish. RECOMMENDED FOOTPRINT DETAILS Weight: 2.1g (C) 1.9g (PC) TUBE OUTLINE DIMENSIONS 9.3 [0.366] 2.54 [0.100] x4 HOLES Ø 0.045 0.039 Ø 1.15 1.00 [ ] 12.43 [0.489] 2.54 [0.100] 18.0 [0.709] Tube quantity: 35 5.0 [0.197] All dimensions in mm (inches) Controlling dimension is mm. Unless otherwise specified all dimensions in mm [inches] ±0.55mm [0.022]. Tube Length : 520mm [20.472] ±2.0 [0.079]. www.murata.com KDC_NMR.K01 Page 11 of 12 NMR Series Isolated 1W Single Output DC-DC Converters DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to: • Aircraft equipment • Aerospace equipment • Undersea equipment • Power plant control equipment • Medical equipment • Transportation equipment ( automobiles, trains, ships, etc.) • Traffic signal equipment • Disaster prevention / crime prevention equipment • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2023 Murata Power Solutions (Milton Keynes) Ltd. www.murata.com KDC_NMR.K01 Page 12 of 12
NMR100PC 价格&库存

很抱歉,暂时无法提供与“NMR100PC”相匹配的价格&库存,您可以联系我们找货

免费人工找货