NMUSB202MC
www.murata.com
Powered Dual Port USB Data Isolator
System
voltage
rail/
External
adapter
Power
Isolated
DC-DC
Converter
LDO Linear
Regulator
USB
SB Pow
Power
Switch
FEATURES
Isolated dual powered USB 2.0 compliant
Surface mount module
USB Data
Port from
PC/USB
Host
Data
One upstream port, two isolated downstream
ports
Automatic switching between low (1.5Mbps)
and full speed (12Mbps)
Full Speed
USB Isolatorr
USB
SB Hub
Hu
Controller
NMUSB202MC
IIsolated USB
Port 1
U 2.0
USB
Device
D
IIsolated USB
Port 2
U 2.0
USB
D
Device
Isolation
SELECTION GUIDE
Full 500mA available from isolated ports
3kVAC isolation voltage ‘Hi Pot Test’
UL60950 recognised
ANSI/AAMI ES60601-1 1MOPP/2MOOPs
recognised
Industrial temperature range -40°C to
+85°C
Short circuit/overload protected USB ports
Power surge notification
Patents pending
Order Code1
NMUSB202MC
PRODUCT OVERVIEW
The NMUSB202MC is a surface mount module which conveniently provides dual port USB data isolation
from a single upstream port with full power (500mA) available from each downstream port. Isolation
provides effective breaking of ground loops and immunity to EMI in harsh environments as found in
industrial and medical applications. Full speed (12Mbps) and low speed (1.5Mbps) are supported with
automatic switching. Input power of 5V must be provided by an external ‘adapter’ or system voltage rail.
The input power of 5V provided to the hub cannot be sourced from a USB connection.
3D model available
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
NMUSB202MC-R7 (23 pieces per reel), or NMUSB202MC-R13 (92 pieces per reel).
For full details go to
https://www.murata.com/englobal/products/power/rohs
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata.com
KDC_NMUSB202MC.F01 Page 1 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
DC-DC CHARACTERISTICS
INPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Voltage range
Continuous operation
4.5
5
5.5
Units
Current (hub inactive)
5V input
70
mA
Current (hub active) 0% load
5V input
110
mA
Current 100% load
5V input
1.3
A
Input reflected ripple current
5V input
31
mA(rms)
V
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Downstream voltages
5V output
4.75
5
5.25
V
Peak deviation (0-50-0% & 50-100-50% swing)
-5
+3
%Vout
Settling time
40
400
μs
Parameter
Conditions
Min.
Typ.
Max.
Units
Operation
Storage
Product temperature rise above ambient
See derating curve
-40
-50
°C
31
85
105
37
Typ.
Max.
Units
Transient response
MODULE CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
100% Load, Nom VIN, Still Air (measured on transformer core)
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso = 1kVDC
3000
20
VAC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Leakage current
Common mode transient immunity
ESD rating
250 VAC 50Hz
1.31
25
Typ.
Max.
Units
1.35
Rated on model
2000
μA
kV/ μs
V
Calculated using MIL-HDBK-217 FN2 calculation model with nominal input
voltage at full load, 25°C ambient temperature
600
kHrs
Calculated using Telecordia SR-332 calculation model with nominal input
voltage at full load, 25°C ambient temperature
3300
kHrs
MTTF
ABSOLUTE MAXIMUM RATINGS
Parameter
Conditions
Value
Short-circuit protection
Input voltage
Downstream USB 5V
Upstream USB 5V supply
Continuous
5.5V
www.murata.com
KDC_NMUSB202MC.F01 Page 2 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMUSB202MC data isolator is 100% production tested at its stated isolation voltage. This is 3kVAC for 1 second.
The NMUSB202MC series has been recognised by Underwriters Laboratory to 250 Vrms Reinforced Insulation.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
SAFETY APPROVAL
ANSI/AAMI ES60601-1
The NMUSB202MC is recognised to ANSI/AAMI ES60601-1 and provides 1 MOPP (Means Of Patient Protection) and 2 MOOP (Means Of Operator Protection) based upon a working
voltage of 250 Vrms max, between Primary and Secondary.
UL 60950
The NMUSB202MC series has been recognised by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms.
FUSING
The NMUSB202MC series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined
below.
NMUSB202MC - 2.5A (125Vdc rated)
All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE, MSL AND PSL INFORMATION
NMUSB202MC is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC as per
J-STD-020D.1. Please refer to application notes for further information. The pin termination finish on this product series is
Gold with Nickel Pre-plate. The series is backward compatible with Sn/Pb soldering systems. The product has a Moisture
Sensitivity Level (MSL) 3.
www.murata.com
KDC_NMUSB202MC.F01 Page 3 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
TEMPERATURE DERATING GRAPH
NMUSB202MC
6.00
Output Power (W)
5.00
4.00
Still Air
100 lfm
3.00
200 lfm
400 lfm
2.00
1.00
0.00
50
60
70
80
Temperature (°C)
EFFICIENCY GRAPH
NMUSB202MC
90
80
Efficiency (%)
70
60
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata.com
KDC_NMUSB202MC.F01 Page 4 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
EMC FILTERING AND SPECTRA
FILTERING
The following filter circuit and filter table shows the input filters typically required to meet EN55022 Quasi-Peak Curve A or B.
L1
ISOLATOR
C2
C1
R1
USB
C1 Ceramic capacitor
C2 Electrolytic capacitor
TO MEET CURVE B
Part Number
NMUSB202MC
C1
10μF
L1
10μH
C2
470μF
R1
0.5Ω
NMUSB202MC
100
90
80
70
dBuV
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata.com
KDC_NMUSB202MC.F01 Page 5 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
APPLICATION NOTES
NMUSB202MC is equivalent to one USB hub for dynamic characteristics, verified by the setup in the figure below for worst case USB specification of 5 cascaded hubs.
The host PC counts as one hub.
Equipment
Use
Tektronix DPO5034B Scope
Scope Firmware 7.2.0 Build 4
TekExpress USB2 1.0.0.65
Framework version 3.0.1.51
Tektronix TPP0500 500MHZ 300V CATII 3.9pF probes
Thurlby PL320
HP Elite Desk 800G F6X32ET~ABU
HP Compaq DC5800
Keithley 2000 DMM
Keithley 2000 DMM
Pro Signal PS11116 5M Certified USB cables
Newlink USB 4-Port Hubs
Integral “Splash Black” USB flash drive (8GB)
HP 672652-001
Logitech 810-003656
TektronixUSB test fixture TDSUSBF
Signal Qualification
HOST PC
Full speed HUB 1
Power Supply for NMUSB202MC
Remote From
Remote Into
Vin Measurement
Iin Measurement
USB Cabling
USB Hubs
Full Speed Qualifier
Mouse for Port 1
Mouse for Port 2
Test Fixture
Full speed downstream
signal quality test board
Full speed HUB 3
Full speed HUB 2
Full speed HUB 4
Oscilloscope
NMUSB202MC
Full speed qualifier
attached to test board
Typical Eye Diagram:
The ‘eye’ diagram is an indication of adequate data quality after the worst case of five cascaded USB hubs.
3.64
Voltage
3.06
2.48
1.90
1.32
740m
160m
-420m
-83.33n -66.67n
-50n
-33.33n -16.67n
0
16.67n
33.33n
50n
66.67n
83.33n
Time
www.murata.com
KDC_NMUSB202MC.F01 Page 6 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
APPLICATION NOTES (Continued)
Typical Implementation:
C1, C2 100μF 10V (low ESR type)
Murata P/N: GRM32ER61A107ME20L
Isolated Output
USB1
1 +5V
C1
+5V 3A
(system)
2 D3 D+
4 GND
6
D-(system)
5
4
MURATA
LXES2SBAA4-016
D+(system)
1
2
3
VBUS OUT1 13
D-OUT1 12
GND(system)
D+OUT1 11
2 D-IN
3
4
6
5
2
GND
Isolated Output
USB2
GND1(ISO) 10
9
1
LED
VBUS OUT2 8
+5V
C2
D-OUT2 7
2 D-
D+OUT2 6
GND2(ISO) 5
3 D+
4 GND
4
NMUSB202MC
MURATA
LXES2SBAA4-016
1
D+IN
Isolation
1 +5V
6
5
4
MURATA
LXES2SBAA4-016
3
1
2
3
www.murata.com
KDC_NMUSB202MC.F01 Page 7 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
Pin
Function
1
2
3
4
5
6
7
8
9
10
11
12
13
+5V (UPSTREAM)
D-IN
D+IN
GND (UPSTREAM)
GND2 (DOWNSTREAM)
D+OUT2
D-OUT2
VBUS OUT2
LED PIN
GND1 (DOWNSTREAM)
D+OUT1
D-OUT1
VBUS OUT1
RECOMMENDED FOOTPRINT DETAILS
All dimensions in mm (inches), Controlling dimensions is mm.
Weight: 11 g
www.murata.com
KDC_NMUSB202MC.F01 Page 8 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
REEL PACKAGING DETAILS
50.4 [1.984] MAX#
Ø330 [13.000] MAX
OR
Ø177.8 [7.000] MAX
[
Ø 0.531
Ø 13.5
12.8 0.504
]
GOODS
ENCLOSURE
SECTION
LEADER SECTION
400 [15.748] MIN
TRAILER SECTION
160 [6.299] MIN
100 [3.937]
MIN
1.5 [0.059]
MIN ##
Ø20.2 [Ø0.795]
MIN
Carrier tape pockets shown are
illustrative only - Refer to carrier tape
diagram for actual pocket details.
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches)
Controlling dimension is mm
# Measured at hub
## Six equi-spaced slots on 180mm/7” reel
Reel Quantity: 7” - 23 or 13” - 92
[
4.0 [0.157]
Ø2.0 [Ø0.079] MIN
+0.004
+0.1
Ø1.5 -0.0 Ø0.059 -0.000
2.0 [0.079]
]
#24.5 [0.963]
40.4 [1.591]
44.0±0.3
20.2±0.15
1.75 [0.069]
3° MAX
TAPE OUTLINE DIMENSIONS
0.2 ±0.05
COVER TAPE
3° MAX
23.7 [0.932] #
0.6 [0.024] MAX
15.65 [0.616]
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches)
Controlling dimension is mm
Components shall be orientated within the carrier tape as indicated
# Measured on a plane 0.3mm above the bottom pocket
36.0 [1.417]
DIRECTION OF UNREELING
www.murata.com
KDC_NMUSB202MC.F01 Page 9 of 10
NMUSB202MC
Powered Dual Port USB Data Isolator
DISCLAIMER
Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical
applications.
Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe
damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use.
These applications include but are not limited to:
•
Aircraft equipment
•
Aerospace equipment
•
Undersea equipment
•
Power plant control equipment
•
Medical equipment
•
Transportation equipment ( automobiles, trains, ships, etc.)
•
Traffic signal equipment
•
Disaster prevention / crime prevention equipment
•
Data Processing equipment
Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The
suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and
liability of the buyer.
Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold
Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/
or life-critical applications.
Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: https://www.murata.com/en-eu/products/power/requirements
Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use
of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change
without notice.
© 2022 Murata Power Solutions (Milton Keynes) Ltd.
www.murata.com
KDC_NMUSB202MC.F01 Page 10 of 10