RBQ-12/33-D48NB-C

RBQ-12/33-D48NB-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    DIP5 模块,1/4砖

  • 描述:

    中间总线转换器 直流转换器 1 输出 11.85V 33A 36V - 75V 输入

  • 数据手册
  • 价格&库存
RBQ-12/33-D48NB-C 数据手册
RBQ-12/33-D48xB-C www.murata-ps.com Quarter-Brick 400-Watt Isolated DC-DC Converters Output (Vout, typ) Current (A) Nominal Input (V) 11.7 33 48 Typical unit FEATURES PRODUCT OVERVIEW „„ 386 Watts total output power, 11.7 VDC @ 33 A The fully isolated (2250 Vdc) RBQ-12/33-D48xB-C module accepts a 36 to 75 Volt DC input voltage range (48 VDC nominal) and converts it to a low Vdc output. Applications include 48V-powered datacom and telecom installations, base stations, cellular dataphone repeaters, instruments and embedded systems. Wideband output ripple and noise is a low 100 mV, peak-to-peak. „„ Regulated Intermediated Bus Architecture (RIBA) with PoL converters „„ 96% ultra-high efficiency at full load (typical) „„ 36 to 75 Volt DC input range (48 VDC nominal) „„ Standard quarter-brick footprint „„ Synchronous rectifier topology with 100 mV ripple & noise „„ Up to +85° Celsius thermal performance (with derating) „„ Stable no-load operation „„ Multiple-unit parallel operation for increased current „„ Fully isolated to 2250 VDC (BASIC) The RBQ’s synchronous-rectifier topology with line regulation and fixed frequency operation means excellent efficiencies up to 96%, enabling “no heatsink” operation for most applications up to +85° Celsius (with derating airflow). “No fan” or zero airflow higher temperature applications may use the optional base plate for cold surface mounting or natural-convection heatsinks. A wealth of electronic protection features include input undervoltage lockout (UVLO) , output current limit, short circuit hiccup, and overtemperature shutdown. Available options include positive or negative logic remote On/Off control, conformal coating, and various pin lengths. Assembled using ISO-certified automated surface-mount techniques, the RBQ series is certified to all UL and IEC emissions, safety and flammability standards. „„ Remote On/Off enable control „„ Extensive protection features – SC, OC, UVLO, OT „„ Certified to full safety, emissions and environmental standards „„ Approved to UL 60950-1, CAN/CSAC22.2 No. 60950-1, IEC60950-1, EN60950-1 safety approvals (2nd Edition, with Amendment 1) F1 Isolation Barrier +Vin (1) +Vout (8) • Switching External DC Power Source On/Off Control (2) Open = On Closed = Off (Positive logic) • Filters Controller and Power Transfer Duty Cycle Regulation • Current Sense Reference and Error Amplifier -Vin (3) -Vout (4) Figure 1. Connection Diagram Typical topology is shown. Murata Power Solutions recommends an external fuse at F1. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_RBQ-12/33-D48.C01∆  Page 1 of 15 RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Output Root Model ➀ RBQ-12/33-D48xB-C Total Vout IOUT Power (V, typ) (A, typ) (W, typ) 11.7 33 386 Input Ripple & Noise (mVp-p) Typ. Max. 100 200 Regulation (max.) ➁ VIN Nom. Range Line (%) Load (%) (V) (V) +1/-2 ➀ Please refer to the part number structure for additional options and complete ordering part numbers. ➁ Regulation specifications describe the output voltage deviations as the line voltage or load current is varied from its nominal/midpoint value to either extreme. (Load step = ±25 %). Line Regulation tested from 40V to 75V, output @nominal load. ±3 48 36-75 IIN, min. IIN, full load load (mA) (A) 140 8.59 Efficiency Dimensions (inches) (mm) Typ. 96% 2.3 x 1.45 x 0.5 58.4 x 36.8 x 12.7 ➂ All specifications are at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See detailed specifications. Output capacitors are 1μF, 10uF and 470μF in parallel, with a 220μF input capacitor. I/O caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE RB Q - 12 / 33 - D48 N B S H Lx - C RoHS Hazardous Materials compliance C = RoHS 6 (does not claim EU RoHS exemption 7b–lead in solder), standard Output Configuration RB = Regulated Converter Pin Length Option (Through-hole packages only) Quarter-Brick Package Isolated converter Blank = Standard pin length 0.180 inches (4.6mm) L1 = Pin length 0.110 inches (2.79mm) ➀ L2 = Pin length 0.145 inches (3.68mm) ➀ Maximum Output Voltage (11.85V) Conformal coating (optional) Blank = no coating, standard H = Coating added, optional ➀ Maximum Rated Output Current in Amps Input Voltage Range D48 = 36-75V, 48V nominal Load Share Option Blank = no share S = Load share Baseplate B = Baseplate installed, standard NOTE: This product is not available without the baseplate. On/Off Control Logic Option N = Negative logic P = Positive logic ➀ Special quantity order is required; samples available with standard pin length only. ➁ Some model number combinations may not be available. See website or contact your local Murata sales representative. www.murata-ps.com/support MDC_RBQ-12/33-D48.C01∆  Page 2 of 15 RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters FUNCTIONAL SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Isolation Voltage On/Off Remote Control Output Power Conditions ➀ Minimum Full power operation Operating or non-operating, 100 mS max. duration Input to output, 100 mS to IEC/EN/UL 60950-1 Power on or off, referred to -Vin 0 Typical/Nominal Maximum Units 80 Vdc 0 100 Vdc 0 0 2250 15 391 Vdc Vdc W Current-limited, no damage, short-circuit 0 33 A protected Storage Temperature Range Vin = Zero (no power) -55 125 °C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended. Output Current INPUT Operating voltage range Recommended External Fuse Start-up threshold Undervoltage shutdown Internal Filter Type Input current Full Load Conditions Low Line Inrush Transient Output in Short Circuit No Load Input Current (Iout @ min) Shut-Down Mode Input Current Reflected (back) ripple current ➁ 36 Fast blow Rising input voltage Falling input voltage 32 30 Vin = minimum Iout = minimum, unit=ON 48 20 33.5 31.5 Pi 75 35 33 Vdc A Vdc Vdc 8.59 10.8 8.68 12 0.3 0.5 200 10 200 A A A2-Sec. A mA mA mA, RMS 140 5 70 Measured at input with specified filter GENERAL and SAFETY Efficiency Vin=48V, full load Vin=75V, full load Isolation Isolation Voltage, input to output Isolation Voltage, input to baseplate Isolation Voltage, output to baseplate Insulation Safety Rating Isolation Resistance Isolation Capacitance Safety Calculated MTBF 95 93 96 94 % % 2250 1500 1500 Vdc Vdc Vdc basic 10 1500 UL-60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1, 2nd Edition with Amendment 1 Per Telcordia SR332, issue 1, class 3, ground fixed, Tambient=+25°C Mohm pF Yes 1.8 Hours x 106 DYNAMIC CHARACTERISTICS Fixed Switching Frequency Startup Delay Startup Delay Dynamic Load Response Dynamic Load Peak Deviation 360 KHz Power On to Vout regulated, 10-90% Vout, resistive load Remote ON to 10% of Vout 50-75-50% load step, settling time to within ±2% of Vout Same as above 20 mS 10 mS 350 µSec ±400 mV 1 0.8 15 2 V V mA 1 15 1 2 V V mA Typical/Nominal Maximum Units FEATURES and OPTIONS Remote On/Off Control ➃ “N” suffix: Negative Logic, ON state Negative Logic, OFF state Control Current “P” suffix: Positive Logic, ON state Positive Logic, OFF state Control Current OUTPUT ON = Pin grounded or external voltage OFF = Pin open or external voltage Open collector/drain -0.1 2.5 ON = Pin open or external voltage OFF = Ground pin or external voltage Open collector/drain 3.5 0 Conditions ➀ Minimum www.murata-ps.com/support MDC_RBQ-12/33-D48.C01∆  Page 3 of 15 RBQ-12/33-D48xB-C Quarter-Brick 400-Watt Isolated DC-DC Converters FUNCTIONAL SPECIFICATIONS (CONT.) Total Output Power Voltage Nominal Output Voltage Nominal Output Voltage Total Output Range Vout Overshoot Voltage Output Voltage (initial output set point @48V, no load) Output Voltage (initial output set point @48V, 50% load) Output Voltage (initial output set point @48V, 100% load) Output Voltage Overvoltage Protection Current Output Current Range Minimum Load Current Limit Inception Short Circuit Short Circuit Current Short Circuit Duration (remove short for recovery) Short circuit protection method Regulation ➄ Line Regulation Load Regulation Ripple and Noise Temperature Coefficient Maximum Capacitive Loading (10% ceramic, 90% Oscon) See Derating 0 386 391 W Measured @ 48Vin, Full Load. Measured @ 48Vin, Half Load. Over sample load (0-33A), input line (40-75V) and temperature (see derating curves) , for regular model and S option 11.4 11.55 11.7 11.7 12.5 11.85 Vdc Vdc 11 12.5 V 12.9 13.1 V For S option only 11.7 12.5 Vdc For S option only 11.685 11.715 Vdc For S option only 11.5 11.7 Vdc 11.0 12.5 Vdc For S option only: total output range (input line, load, temperature, samples) Output Voltage clamped (see technical note) N/A 0 98% of Vnom., after warmup 40 V 33 No minimum load 46 Hiccup technique, autorecovery within 1.25% of Vout Output shorted to ground, no damage 33 A 50 A 6 A +1/-2 ±3 200 0.02 % % mV pk-pk % of Vnom./°C 6000 μF Continuous Current limiting Vin=40 to 75V Iout=min. to max., Vin=48V 5 Hz- 20 MHz BW At all outputs Cap. ESR=
RBQ-12/33-D48NB-C 价格&库存

很抱歉,暂时无法提供与“RBQ-12/33-D48NB-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货