TWR-5/3000-15/500-D48A-C

TWR-5/3000-15/500-D48A-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    DIP7 模块

  • 描述:

    隔离模块 直流转换器 3 输出 5V 15V -15V 3A,500mA,500mA 18V - 75V 输入

  • 数据手册
  • 价格&库存
TWR-5/3000-15/500-D48A-C 数据手册
TWR A-Series www.murata-ps.com 20W, Triple Output DC-DC Converters Typical unit Among the three families of triple-output DC/DC converters in MPS’s A-Series, the 20W 2" x 2" devices are distinguished by their unique “power-sharing” architecture. This feature enables devices to deliver the full 20 Watts of output power under a variety of output-loading conditions. FEATURES PRODUCT OVERVIEW  Low cost! Highly reliable! Each unit’s primary +5V output can source any current up to 3 Amps (primary power = 15W); while its auxiliary ±12/15V outputs can source currents up to ±500mA (auxiliary power = 12/15W). Devices deliver any combination of primary plus auxiliary power as long as the total output power does not exceed 20 Watts. This feature enables designers to select a single device to fulfill any number of different requirements. As members of MPS’s new A-Series, the 20W triples exhibit both low cost and outstanding long-term reliability. Their design combines straightforward circuit topologies, the newest components, proven SMT-on-pcb construction methods, and highly repeatable automatic-assembly techniques. Their superior  Full 20 Watts output power  Power “user-allocated” among outputs  Proven SMT-on-pcb construction  Qual tested; HALT tested; EMC tested  Output voltages: +5V/±12V or +5V/±15V  Ultra-wide input voltage ranges: 9-36V or 18-75V  Designed to meet UL1950/EN60950. BASIC insulation (all 48VIN models)  CE mark available (75V input models)  Small packages, 2" x 2" x 0.45"  Fully isolated, 1500Vdc guaranteed  Guaranteed efficiencies to 82%  –40 to +100°C operating temperature  Modifications and customs for OEM’s durability is substantiated by a rigorous in-house qualification program that includes HALT (Highly Accelerated Life Testing). Each device has a +5V primary output and either ±12V or ±15V auxiliary outputs. “D12A” models achieve fully rated performance with inputs ranging from 9 to 36 Volts. “D48A” models operate over an input range of 18-75 Volts. These full-featured triples have non-latching output current limiting, input overvoltage shutdown, input reverse-polarity protection, and output overvoltage clamping to protect both the power converters and their loads. SIMPLIFIED SCHEMATIC +5V +V IN (1) (6) –12V (–15V) – V IN (8) (2) ON /O FF CONTROL +12V (+15V) (5) PWM CONTROLLER (4) COMMON (7) OPTO ISOLAT ION ERROR AMPLIFIER   For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_TWR20W.E02 Page 1 of 8 TWR A-Series 20W, Triple Output DC-DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE  Output R/N (mVp-p) Regulation VOUT IOUT  Model Family (V) (mA) Typ. Max. Line Load Input VIN Nom. (Volts) Range (Volts) IIN  (mA) Min. Typ. Package (Case/ Pinout) Efficiency TWR-5/3000-12/500-D12A-C +5 ±12 3000 ±500 50 75 100 125 ±0.2% ±0.5% ±0.5% ±6% 12 9-36 20/1004 81% 82% C4, P13 TWR-5/3000-12/500-D48A-C +5 ±12 3000 ±500 50 75 100 125 ±1% ±1% ±2% ±5% 48 18-75 40/559 82% 83% C4, P13 TWR-5/3000-15/500-D12A-C +5 ±15 3000 ±500 50 75 100 150 ±0.1% ±0.5% ±0.25% ±4% 12 9-36 40/1173 81% 82% C4, P13 TWR-5/3000-15/500-D48A-C +5 ±15 3000 ±500 50 75 100 150 ±1% ±1% ±2% ±5% 48 18-75 40/559 81% 82% C4, P13  Typical @ TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted.  For the +5V output, listed spec applies over the 10% to 100% load range. For the ±12/15V outputs, For testing and specification purposes, “full load” is defined as 2.75A on the primary +5V output and listed spec applies for balanced loads over the 20% to 100% load range. ±250/200mA on the auxiliary ±12/15V outputs. This corresponds to a total output power of 19.75W.  Nominal line voltage, no-load/full-load conditions.  Ripple/Noise (R/N) measured over a 20MHz bandwidth. PART NUMBER STRUCTURE MECHANICAL SPECIFICATIONS T WR - 5 / 3000 - 15 / 500 - D48 A - C 2.00 (50.80) Output Configuration: T = Triple RoHS-6 compliant* A-Series High Reliability Wide Range Input Input Voltage Range: Nominal Primary Output: D12 = 9-36V (12V nominal) Voltage (+5V) D48 = 18-75V (48V nominal) Maximum Auxilliary Output: Maximum Primary Output Current in mA Currents in mA from each output Nominal Auxiliary Output: * Contact Murata Voltages (±12 or ±15V) Power Solutions for availability. ME T A L C A S E 0.45 (11.43) Case C4 IN S U LA T E D B A S E 0.040 ±0.002 D IA . (1.016 ±0.051) 0.20 MIN (5.08) 1.800 (45.72) 0.10 (2.54) 5 0.200 (5.08) 6 TEMPERATURE DERATING 1 2 20 7 0.400 (10.16) 19 1.200 (30.48) 3 E Q . SP. @ 0.400 ( 10.16) 2.00 (50.80) 4 18 17 8 16 0.100 (2.54) 15 0.40 (10.16) B O T T O M V IE W 14 Output Power (Watts) 13 12 11 INPUT/OUTPUT CONNECTIONS 10 9 Pin Function P13 8 1 +Input 7 2 -Input 5 3 No Pin 4 4 On/Off Control 3 5 +12V/15V Output 6 +5V Output 6 2 1 0 –40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 7 Common 8 -12V/15V Output Note: For “D12A” models, the case is connected to pin 2 (–VIN). For “D48A” models, the case is connected to pin 1 (+VIN). Dimensions are in inches (mm) Ambient Temperature (°C) www.murata-ps.com/support MDC_TWR20W.E02 Page 2 of 8 TWR A-Series 20W, Triple Output DC-DC Converters Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage and “full-load” conditions, unless noted. Input Input Voltage Range: D12A Models D48A Models 9-36 Volts (24V nominal) 18-75 Volts (48V nominal) Input Current See Ordering Guide Input Voltage: “D12” Models “D48” Models Input Filter Type  Pi Input Reverse-Polarity Protection Overvoltage Shutdown: D12A Models D48A Models 40 Volts 80 Volts Reverse-Polarity Protection Yes (Instantaneous, 6A maximum) On/Off (Sync.) Control (Pin 4)  TTL high = off, low (or open) = on Output Overvoltage Protection +5V Output ±12V Outputs ±15V Outputs Absolute Maximum Ratings Output Total Output Power 20W max., sum of all outputs VOUT Accuracy (50% loads): +5V Output ±12V or ±15V Outputs ±1% ±3% Temperature Coefficient ±0.02% per °C Ripple/Noise (20MHz BW)  See Ordering Guide Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Isolation Voltage  1500Vdc, minimum Isolation Capacitance 500pF Current Limiting Power down to restart Short Circuit Protection at 25ºC 5 min. max, 5V output 30 sec max.12/15V outputs Overvoltage Protection back Zener/transorb clamps, magnetic feed- Dynamic Characteristics Transient Response (50% load step) 300μsec max. to ±2% of final value Switching Frequency 165kHz (±15kHz) Environmental Operating Temperature (ambient): Without Derating With Derating –40 to +55°C to +100°C (See Derating Curve) Storage Temperature –40 to +105°C Physical Dimensions 2" x 2" x 0.45" (51 x 51 x 11.4mm) Shielding 5-sided Case Connections: D12A Models D48A Models Pin 2 (–VIN) Pin 1 (+VIN) Case Material Corrosion resistant steel with non-conductive, epoxy-based, black enamel finish and plastic baseplate Pin Material Copper alloy with gold plate over nickel underplate Weight 2.7 ounces (77 grams)  These converters require 10% min. loading on their primary output and 20% min. loading on their auxiliary outputs to maintain specified regulation. Operation under no-load conditions will not damage the devices; however they may not meet all listed specifications. For testing and specification purposes, “full load” is defined as 2.75A on the primary +5V output and ±250/200mA on the auxiliary ±12/15V outputs. This corresponds to a total output power of 19.75W.  Application-specific internal input/output filtering can be recommended or perhaps added internally upon request. Contact MPS Applications Engineering for details.  Applying a voltage to the Control pin when no input power is applied to the converter can cause permanent damage to the converter.  D48A models have BASIC, D12A models have Functional insulation.Devices can be screened or modified for higher guaranteed isolation voltages. Contact MPS Applications Engineering for details.  To avoid damage to the surface finish, please do not use certain cleaning agents such as Vigon. Contact Murata Power Solutions for information. 44 Volts 88 Volts Current must be
TWR-5/3000-15/500-D48A-C 价格&库存

很抱歉,暂时无法提供与“TWR-5/3000-15/500-D48A-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货