UHE Series
www.murata-ps.com
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Housed in smaller, 1.6" x 2" x 0.40" (41 x 51 x 10.2mm)
packages carrying the standard 2" x 2" pinout, MPS’s new
UHE Series DC/DC Converters deliver more current/power
(up to 10A/30W) than currently available from either
package size.
Typical units
FEATURES
PRODUCT OVERVIEW
n
The most IOUT/POUT in this format
The UHE 12-30W Series of high-efficiency,
isolated DC/DC’s provide output power ranging
from 10 Amps @ 1.2V to 2 Amps @ 15V. Offering
both 2:1 and 4:1 input voltage ranges, UHE’s meet
Vin requirements from 9 to 75 Volts.
Taking full advantage of the synchronousrectifier, forward topology, UHEs boast outstanding
efficiency (some models exceed 91%) enabling
full-power operation to ambient temperatures as
high as +60°C, without air flow. Assembled using
fully automated, SMT-on-pcb techniques, UHEs
provide stable no-load operation, excellent line
(±0.1%) and load (±0.15%) regulation, quick step
response (200µsec), and low output ripple/noise
(50-100mVp-p). Additionally, the UHEs unique
output design eliminates one of the topology’s few
shortcomings–output reverse conduction.
n
Lower priced than bricks
n
Small 1.6" x 2" x 0.4" plastic package
with standard 2" x 2" pinout
n
Output configurations:
1.2/1.5/1.8/2.5VOUT @ 10 Amps
3.3/5VOUT @ 25 Watts
5/12/15VOUT @ 30 Watts
n
Five input ranges from 9-75 Volts
n
Efficiencies as high as 91.5%
n
Stable no-load operation
n
Optional Sense pins for low VOUT
n
Thermal shutdown, I/O protected
n
1500 Vdc I/O BASIC Insulation
All devices feature full I/O fault protection
including: input overvoltage and undervoltage
shutdown, precise output overvoltage protection
(a rarity on low-voltage outputs), output current
limiting, short-circuit protection, and thermal
shutdown.
All UHE models incorporate a Vout Trim function
and an On/Off Control pin (positive or negative
logic). Low-voltage models (1.2V to 5V) offer
optional sense pins facilitating either remote load
regulation or current sharing for true N+1 redundancy. All models are certified to the BASIC insulation requirements of UL/EN60950-1 (2nd Edition),
and 48Vin (75V max.) models carry the CE mark.
Selected models are RoHS compliant (Reduction
of Hazardous Substances).
n
UL/EN60950-1 certified (2nd Edition);
CE marked for Q48 models
n
RoHS compliant
+OUTPUT
(6)
+INPUT
(1)
SWITCH
CONTROL
+SENSE
(5)
–OUTPUT
(7)
–SENSE
(8)
OPTO
ISOLATION
THERMAL
SHUTDOWN
–INPUT
(2)
OVERVOLTAGE
COMPARATOR
PWM
CONTROLLER
OPTO
ISOLATION
REFERENCE &
ERROR AMP
VOUT TRIM
(9)
UVLO & OVLO
COMPARATORS
ON/OFF
CONTROL
(4)
Typical topology is shown.
Optional comparator feedback. Contact MPS.
Sense pins are optional on 1.2-5VOUT models ("R" suffix).
*
One phase of two is shown.
For full details go to
www.murata-ps.com/rohs
Figure 1. Simplified Block Diagram
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 1 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀
Output
Model Family
Regulation (Max.)
R/N (mVp-p)➁
(See model numbering
VOUT
IOUT
Typ.
Max.
Line
on page 3)
Load ➃
(Volts) (Amps)
To Be Discontinued *
UHE-1.2/10000-D12-C
UHE-1.2/10000-D24-C
UHE-1.2/10000-D48-C
UHE-1.5/10000-D24-C
UHE-1.5/10000-D48-C
UHE-1.8/10000-D24-C
UHE-1.8/10000-D48-C
UHE-2.5/10000-D24-C
UHE-2.5/10000-D48-C
UHE-3.3/7500-Q12-C
UHE-3.3/7500-Q48-C
UHE-3.3/7500-D48-C
UHE-3.3/7500-D48T-C
UHE-5/5000-Q12-C
UHE-5/5000-Q48-C
UHE-5/6000-Q12-C
UHE-5/6000-D48-C
UHE-5/6000-D48T-C
UHE-5/6000-Q48T-C
UHE-12/2500-Q12-C
UHE-12/2500-D12-C
UHE-12/2500-D24-C
UHE-12/2500-Q48-C
UHE-12/2500-D48-C
UHE-15/2000-D12-C
UHE-15/2000-Q12-C
UHE-15/2000-D24-C
UHE-15/2000-Q48-C
UHE-15/2000-D48-C
UHE-5/6000-Q48-C
1.2
1.2
1.2
1.5
1.5
1.8
1.8
2.5
2.5
3.3
3.3
3.3
3.3
5
5
5
5
5
5
12
12
12
12
12
15
15
15
15
15
5
10
10
10
10
10
10
10
10
10
7.5
7.5
7.5
7.5
5
5
6
6
6
6
2.5
2.5
2.5
2.5
2.5
2
2
2
2
2
6
80
80
80
55
55
70
50
50
65
70
90
80
80
50
60
50
80
65
55
125
65
65
100
60
70
70
70
100
70
55
120
120
120
80
80
90
75
100
120
90
125
100
100
70
90
70
100
100
80
165
100
100
120
100
100
100
100
150
100
80
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.075%
±0.1%
±0.25%
±0.35%
±0.2%
±0.2%
±0.1%
±0.05%
±0.1%
±0.2%
±0.2%
±0.08%
±0.1%
±0.2%
±0.2%
±0.1%
±0.2%
±0.2%
±0.05%
±0.2%
±0.1%
±0.2%
±0.08%
Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Ripple/Noise (R/N) is tested/specified over a 20MHz bandwidth. All models are specified with
an external 0.47µF multi-layer ceramic capacitor installed across their output pins.
Nominal line voltage, no-load/full-load conditions.
UHE-3.3/7500-D48
UHE-3.3/7500-D48N
UHE-3.3/7500-D48N-31016
UHE-3.3/7500-D48N-C
UHE-3.3/7500-D48NR-C
UHE-3.3/7500-D48R-C
UHE-3.3/7500-D48T
UHE-3.3/7500-D48T-31137-Y
UHE-3.3/7500-D48T-C
UHE-3.3/7500-D48THL2-C
UHE-3.3/7500-D48THL2-C-HW
UHE-3.3/7500-D48THL2-Y
UHE-3.3/7500-Q12
UHE-3.3/7500-Q12N
UHE-3.3/7500-Q12N-C
UHE-3.3/7500-Q12NR
UHE-3.3/7500-Q12NR-C
UHE-3.3/7500-Q12R
UHE-3.3/7500-Q12R-C
UHE-3.3/7500-Q48
UHE-3.3/7500-Q48N
UHE-3.3/7500-Q48N-C
UHE-3.3/7500-Q48NR-C
UHE-3.3/7500-Q48R-C
UHE-5/5000-Q12
UHE-5/5000-Q12N
UHE-5/5000-Q12N-C
UHE-5/5000-Q12NR
UHE-5/5000-Q12NR-C
UHE-5/5000-Q12R
UHE-5/5000-Q12R-C
UHE-5/5000-Q48
UHE-5/5000-Q48N
UHE-5/5000-Q48N-C
±0.36/0.9%
±0.25/0.9%
±0.3/0.625%
±0.15/0.625%
±0.15/0.625%
±0.15/0.625%
±0.15/0.625%
±0.15/0.5%
±0.15/0.5%
±0.2/0.5%
±0.5%
±0.5%
±0.5%
±0.15/0.3%
±0.15/0.3%
±0.3%
±0.25/0.5%
±0.5%
±0.15%
±0.5%
±0.3%
±0.3%
±0.5%
±0.3%
±0.3%
±0.15%
±0.3%
±0.5%
±0.3%
±0.15%
Input
VIN Nom. Range
(Volts) (Volts)
12
24
48
24
48
24
48
24
48
24
48
48
48
24
48
24
48
48
48
24
12
24
48
48
12
24
24
48
48
48
9-18
18-36
36-75
18-36
36-75
18-36
36-75
18-36
36-75
9-36
18-75
36-75
36-75
9-36
18-75
9-36
36-75
36-75
18-75
9-36
9-18
18-36
18-75
36-75
9-18
9-36
18-36
18-75
36-75
18-75
Iin ➂
(mA/A)
75/1.2
35/0.6
35/0.31
35/0.73
35/0.38
35/0.86
35/0.44
35/1.23
35/0.59
50/1.17
38/0.57
35/0.6
35/0.58
50/1.2
38/0.58
50/1.44
45/0.7
45/0.7
38/0.69
55/1.43
90/2.81
55/1.39
30/0.6
30/0.7
110/2.81
50/1.4
70/1.39
45/0.69
35/0.7
38/0.69
Efficiency
Min. Typ.
81%
82.2%
81%
84%
82.5%
85.5%
83.5%
87.7%
87%
85%
88%
86.7%
85.5%
86%
87.5%
86.5%
87.5%
87.5%
88.5%
85.5%
87%
88%
88%
90%
87%
88%
88%
88%
90%
88.5%
83.5%
83%
83%
85.5%
84%
87%
85%
88.7%
88.5%
88%
90%
88.7%
88.2%
87.5%
90%
87%
89%
91%
90%
87.5%
89%
90%
90%
92%
89%
89.5%
90%
90%
92%
90%
Package
(Case/
Pinout)
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51/52
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
C32, P51
Devices have no minimum-load requirements and will regulate under no-load conditions.
Regulation specifications describe the output voltage deviation as the line voltage or load
(with/without sense option) is varied from its nominal/midpoint value to either extreme.
UHE-5/5000-Q48NR
UHE-5/5000-Q48NR-C
UHE-5/5000-Q48R
UHE-5/5000-Q48R-C
UHE-5/6000-D48N-30749-Y
UHE-5/6000-D48N-C
UHE-5/6000-D48NR
UHE-5/6000-D48NR-C
UHE-5/6000-D48R
UHE-5/6000-D48R-C
UHE-5/6000-D48T-31136-C
UHE-5/6000-D48T-31136-Y
UHE-5/6000-D48T-C
UHE-5/6000-D48THL2-C
UHE-5/6000-D48THL2-C-HW
UHE-5/6000-D48THL2-Y
UHE-5/6000-D48-Y
UHE-5/6000-D48-Y-CIS
UHE-5/6000-Q12N
UHE-5/6000-Q12N-C
UHE-5/6000-Q48T-C
UHE-12/2500-D12
UHE-12/2500-D12N
UHE-12/2500-D12N-C
UHE-12/2500-D24
UHE-12/2500-D24N
UHE-12/2500-D24N-C
UHE-12/2500-D48
UHE-12/2500-D48N
UHE-12/2500-D48N-C
UHE-12/2500-Q12
UHE-12/2500-Q12N
UHE-12/2500-Q12N-C
UHE-12/2500-Q48
UHE-12/2500-Q48N
UHE-12/2500-Q48N-C
UHE-12/2500-Q48-Y
UHE-15/2000-D12
UHE-15/2000-D12N
UHE-15/2000-D12N-C
UHE-15/2000-D24
UHE-15/2000-D24N
UHE-15/2000-D24N-C
UHE-15/2000-D48
UHE-15/2000-D48N
UHE-15/2000-D48N-C
UHE-15/2000-Q12
UHE-15/2000-Q12N
UHE-15/2000-Q48
UHE-15/2000-Q48N
UHE-15/2000-Q48N-C
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 2 of 16
* Last Time Buy date is 3/31/2019. Please click here to view the Discontinuance Notification.
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
PART NUMBER STRUCTURE
U HE - 3.3 / 7500 - D48 N - C
Output Configuration:
U = Unipolar
High Efficiency
Nominal Output Voltage:
1.2, 1.5, 1.8, 2.5, 3.3, 5, 12 or 15
Maximum Rated Output
Current in mA
RoHS-6 hazardous substance compliant
(Does not claim EU exemption 7b, lead in solder)
On/Off Logic
Blank = Positive logic, standard
N = Negative logic
R = See Below
optional, special order
NR = See Below
}
Input Voltage Range:
D12 = 9-18 Volts
D24 = 18-36 Volts
D48 = 36-75 Volts
Q12 = 9-36 Volts
Q48 = 18-75 Volts
Note: Some model number
combinations may not be available.
Contact Murata Power Solutions.
Options and Adaptations
Alternate pin lengths are available under special order
Optional Functions and Part Number Suffixes
The versatile UHE, 12-30W DC/DC converters offer numerous electrical and
mechanical options. Per the Ordering Guide on page 2, the trailing DXX or QXX
(where XX stands for 12, 24 or 48Vin) in each part number pertains to the base
part number. Part-number suffixes are added after this input identification,
indicating the selection of standard options. The resulting part number is a
"standard product" and is available to any customer desiring that particular
combination of options.
T
Alternate trim configuration. Special order only.
-C
Full RoHS-6 compliance.
-Y
RoHS-5 hazardous substance compliance with lead exception. RoHS-5
compliance requires a scheduled quantity order. Not all RoHS-5 “-Y”
models are available. Please contact Product Marketing for further
information.
The On/Off Control function on pin 4 employs a positive logic (on = open or
"high," no suffix). To request a negative logic on this pin/function, add an "N"
suffix to the part number. Standard models have no pins in the pins 5 and 8
positions. For 5-10A models (1.2-5Vout), ±Sense pin/functions can be added to
these positions (see pinout P52) by adding an "R" suffix. An "NR" suffix can be
added for both negative-logic and sense-pin options. See below.
Suffix Description
Blank Positive logic On/Off Control function (pin 4), Vout trim (pin 9),
no Sense pins, pin length 0.2 inches (5.08 mm).
N
Add Negative logic on the On/Off Control function, VOUT trim (pin 9),
no Sense pins.
R
Positive logic on the On/Off Control function, Vout trim (pin 9), ±Sense
pins in the pin 5 and pin 8 positions (available for low Vout models
only). Available under special order.
NR
Negative logic on the On/Off Control function, Vout trim (pin 9), +/–
Sense pins in the pin 5 and pin 8 positions (available for low Vout
models only). Available under special order.
Adaptations
There are various additional configurations available on UHE, 12-30W DC/DCs.
Because designating each of them with a standard part-number suffix is not
always feasible, such are designated by MPS in assigning a 5-digit “adaptation
code” after the part-number suffixes. Contact MPS directly if you are interested
in your own set of options/adaptations. Our policy for minimum order quantities
may apply. Consequently, the following products are offered for sale:
UHE-5/6000-D48N-30749
UHE-5/6000-D48N-30749-Y (RoHS-5)
Standard product, 48Vin, 5V/6A output with negative logic on the On/Off Control
function, modified Trim function (5% trim up = 9.09kΩ, 5% trim down =
3.83kΩ, compatible with UEP-30750), integrated soft start and with input OVP
and thermal shutdown removed.
RoHS-5 compliance refers to the exclusion of the six hazardous substances
in the RoHS specification with the excepion of lead. MPS’s RoHS-5 products
use all the conforming RoHS materials, however our solders contain lead.
UHE-3.3/7500-D48THL2-Y and
UHE-5/6000-D48THL2-Y (RoHS-5)
Special trim, conformal coating, 3.68mm pin length, positive on/off logic,
RoHS-5 hazardous substance compliance (with lead).
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 3 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
MECHANICAL SPECIFICATIONS
Dimensions are in inches (mm) shown for ref. only.
INPUT/OUTPUT CONNECTIONS
Pin
Function P51
1
Function P52
+Input
Third Angle Projection
+Input
2
–Input
–Input
3
No Pin
No Pin
4
On/Off Control
On/Off Control
5
No Pin
Sense*
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
6
+Output
+Output
Components are shown for reference only.
7
–Output
–Output
8
No Pin
–Sense*
9
Trim
Trim
* Pins 5 and 8 are installed for optional R-suffix versions of 1.2-5VOUT models.
If installed, always connect the sense pins either to a remote load or to their
respective Vout pin.
See page 3 for complete Part Number structure & ordering details.
2.00
(50.8)
PLASTIC CASE
0.40
(10.2)
STANDOFF
0.020 (0.5)
0.040 ±0.001 DIA.
(1.016 ±0.025)
0.20 MIN
(5.08)
1.800
(45.72)
0.10
(2.54)
0.200
(5.1)
0.200
(5.1)
5
6
1
0.400
(10.2)
2
0.400
(10.16)
7
3
0.400 (10.16)
2 EQ. SP. @
0.200 (5.08)
8
4
1.60
(40.6)
9
0.100
(2.5)
BOTTOM VIEW
0.20
(5.1)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 4 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀ ➁
Input
Input Voltage Range:
D12 Models (start up at 10V max.)
Q12 Models (start up at 10V max.)
D24 Models
Q48 Models
D48 Models
9-18 Volts (12V nominal)
9-36 Volts (24V nominal)
18-36 Volts (24V nominal)
18-75 Volts (48V nominal)
36-75 Volts (48V nominal)
Overvoltage Shutdown:
D12 Models
Q12/D24 Models
D48/Q48 Models
18.5-23 Volts
37-42 Volts
Not applicable
Start-Up Threshold: ➁
D12/Q12 Models
D24/Q48 Models
D48 Models
9.4-10 Volts
15.5-18 Volts
33.5-36 Volts
Undervoltage Shutdown: ➁
D12/Q12 Models
D24/Q48 Models
D48 Models
7.0-8.8 Volts
15-17 Volts
32-35.5 Volts
Input Current:
Normal Operating Conditions
Standby Mode (Off, OV, UV)
See Ordering Guide
5mA
Input Reflected Ripple Current ➂
2.5-10mAp-p
Input Filter Type
Reverse-Polarity Protection
Remote On/Off Control (Pin 4): ➃
Positive Logic (Standard)
Maximum Capacitive Loading:
(Low ESR capacitor)
10,000µF (1.2-5VOUT)
2,000µF (12-15VOUT)
Dynamic Characteristics
Dynamic Load Response:
(50-100% load step to ±3% VOUT)
200µsec maximum ➇
Start-Up Time: ➇
VIN to VOUT and On/Off to VOUT
UHE-15/2000-Q12
8msec typical
15msec maximum
30mS typ., 50mS max.
Switching Frequency
150-350kHz (model dependent)
Environmental
5,885,546 hours
LC or Pi type
Operating Temperature (Ambient): ➉
(see Derating Curves)
–40 to +85°C with Derating
Brief duration, 5A maximum
Thermal Shutdown
+115°C to +130°C
Storage Temperature
Flammability
–55 to +125°C
UL 94 V-0
Output
VOUT Accuracy (50% load):
Initial
Temperatue Coefficient
Extreme(5)
±1.5%
±0.02% per °C
±3%
Minimum Loading for Specification: ➁
No load
Ripple/Noise (20MHz BW) ➀
See Ordering Guide
Line/Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
VOUT Trim Range
±5% minimum (±10% for T models)
Remote Sense Compensation ➁
±5%
Isolation Voltage:
Input-to-Output
1500Vdc minimum (BASIC)
Isolation Capacitance
650pF
Isolation Resistance
100MΩ
Current Limit Inception (@98%VOUT): ➆
10 Amp Models
7.5 Amp Models
5/6 Amp Models
2.5 Amp Models
2.0 Amp Models
12-15 Amps
8.2-11.5 Amps
6.5-8.5 Amps
2.6-4 Amps
2.1-3 Amps
Short Circuit Current (Hiccup)
1.5-2.3 Amps
(6)
Magnetic feedback
1.5-2.1 Volts
1.8-2.4 Volts
2.2-2.8 Volts
2.8 to 3.2 Volts
4 to 4.8 Volts
6.1-7.5 Volts
12.7-13.5 Volts
15.8-16.2 Volts
MTBF➈ UHE-12/2500-Q12
On = open, open collector, or to +15V
applied. IIN = 2.6mA max.
Off = pulled low to 0-0.8V. IIN = 2mA max.
On = pulled low to 0-0.8V. IIN = 6mA max.
Off = open, open collector or to +15V
applied. IIN = 1mA max.
Negative Logic ("N" Suffix Models)
Output
Overvoltage Protection:
1.2V Outputs
1.5V Outputs
1.8V Outputs
2.5V Outputs
3.3V Outputs
5V Outputs
12V Outputs
15V Outputs
Physical
Dimensions
1.6" x 2" x 0.40" (40.64 x 50.8 x 10.16mm)
Case Material
Diallyl Phthalate
Pin Material
Gold-plated copper alloy
Weight
1.51 ounces (46.9 grams)
Primary to Secondary Insulation Level
Basic
➀ All models are tested and specified with a single, external, 0.47µF, multi-layer ceramic output
capacitor and no external input capacitors, unless otherwise noted. All models will effectively
regulate under no-load conditions (with perhaps a slight increase in output ripple/noise).
➁ See Technical Notes/Performance Curves for additional explanations and details.
➂ Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33µF input
capacitor and a simulated source impedance of 220µF and 12µH. See I/O Filtering, Input Ripple
Current and Output Noise for details.
➃ The On/Off Control is designed to be driven with open-collector (or equivalent) logic or the application of appropriate voltages (referenced to –Input (pin 2)). Applying a voltage to the On/Off Control
pin when no input voltage is applied to the converter can cause permanent damage. See Remote
On/Off Control for more details.
➄ Extreme Accuracy refers to the accuracy of either trimmed or untrimmed output voltages over all
normal operating ranges and combinations of input voltage, output load and temperature.
➅ Tie the Output Trim pin (pin 9) to +Output (pin 6) for maximum trim down or to –Output (Output
Return/Common, pin 7) for maximum trim up. See Output Trimming for detailed trim equations.
➆ The Current-Limit-Inception point is the output current level at which the converter's power-limiting
circuitry drops the output voltage 2% from its initial value. See Output Current Limiting and
Short-Circuit Protection for more details.
➇ For Start-Up-Time specifications, output settling time is defined as the output voltage having
reached ±1% of its final value at maximum load current.
➈ MTBF’s are calculated using TELCORDIA SR-332 Method 1 Case, ground fixed, +25°C ambient air
and full-load conditions. Contact MPS for demonstrated life-test data.
➉ All models are fully operational and meet all published specifications, including "cold start," at –40°C.
Use only as much output filtering as needed and no more. Larger caps (especially low-ESR ceramic
types) may slow transient response or degrade dynamic performance. Thoroughly test your system
with all components installed.
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 5 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
90
UHE-1.5/10000-D24 Efficiency vs. Load @ +25°C Ambient
90
UHE-1.8/10000-D48 Efficiency vs. Load @ +25°C Ambient
85
85
Efficiency (%)
Efficiency (%)
80
80
VIN = 18V
75
VIN = 24V
75
70
VIN = 36V
65
VIN = 48V
70
60
VIN = 36V
65
1
2
3
4
5
6
7
8
9
55
10
VIN = 75V
1
2
3
Output Current (Amps)
UHE-1.5/10000-D48 Efficiency vs. Load @ +25°C Ambient
90
80
88
75
86
70
VIN = 36V
65
5
VIN = 48V
55
VIN = 75V
1
2
3
4
6
7
82
8
9
10
76
Output Current (Amps)
90
9
10
VIN = 36V
VIN = 48V
VIN = 75V
1
2.8
4.6
6.4
8.2
10
Output Current (Amps)
UHE-1.8/10000-D24 Efficiency vs. Load @ +25°C Ambient
95
UHE-3.3/7500-Q12 Efficiency vs. Load @ +25°C Ambient
90
85
80
Efficiency (%)
Efficiency (%)
8
84
78
5
7
UHE-2.5/10000-D48 Efficiency vs. Load @ +25°C Ambient
80
60
6
Output Current (Amps)
Efficiency (%)
Efficiency (%)
85
4
VIN = 18V
75
VIN = 24V
85
80
VIN = 9V
75
VIN = 24V
70
70
VIN = 36V
VIN = 36V
65
1
2
3
4
5
6
7
Output Current (Amps)
8
9
10
65
0.75
1.5
2.25
3
3.75
4.5
5.25
6
6.75
7.5
Output Current (Amps)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 6 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
UHE-3.3/7500-Q48 Efficiency vs. Load @ +25°C Ambient
100
90
90
80
80
Efficiency (%)
Efficiency (%)
100
70
VIN = 18V
60
VIN = 36V
70
VIN = 18V
60
VIN = 36V
VIN = 48V
VIN = 48V
50
UHE-5/5000-Q48 Efficiency vs. Load @ +25°C Ambient
50
VIN = 75V
VIN = 75V
40
0.75
1.5
2.25
3
3.75
4.5
5.25
6
6.75
40
7.5
0.5
1
1.5
2
UHE-3.3/7500-D48 Efficiency vs. Load @ +25°C Ambient
100
90
90
80
80
Efficiency (%)
Efficiency (%)
100
70
VIN = 36V
60
2.25
3
VIN = 75V
3.75
4.5
5.25
6
6.75
7.5
0.6
1.2
1.8
2.4
3
3.6
4.2
4.8
5.4
6
Output Current (Amps)
UHE-5/5000-Q12 Efficiency vs. Load @ +25°C Ambient
UHE-5/6000-Q12 Efficiency vs. Load @ +25°C Ambient
93
89
85
85
Efficiency (%)
Efficiency (%)
5
VIN = 48V
90
80
VIN = 9V
75
69
VIN = 36V
1.0
1.5
2
2.5
77
3
VIN = 9V
VIN = 12V
VIN = 24V
70
0.5
81
73
VIN = 24V
65
4.5
VIN = 36V
60
Output Current (Amps)
95
4
70
40
1.5
3.5
50
VIN = 75V
40
0.75
3
UHE-5/6000-D48 Efficiency vs. Load @ +25°C Ambient
VIN = 48V
50
2.5
Output Current (Amps)
Output Current (Amps)
3.5
Output Current (Amps)
4
4.5
5
65
0.49
VIN = 36V
0.99
1.49
1.99
2.49 3.00 3.50 4.00 4.50
Output Current (Amps)
5.00
5.50
6.00
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 7 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
UHE-12/2500-D12 Efficiency vs. Load @ +25°C Ambient
95
90
90
85
85
Efficiency (%)
Efficiency (%)
95
80
VIN = 9V
75
UHE-15/2000-D12 Efficiency vs. Load @ +25°C Ambient
80
VIN = 9V
75
VIN = 12V
VIN = 12V
70
70
VIN = 18V
65
0.25
0.5
0.75
1
VIN = 18V
1.25
1.5
1.75
2
2.25
65
2.5
Output Current (Amps)
0.4
0.6
0.8
UHE-12/2500-D24 Efficiency vs. Load @ +25°C Ambient
95
90
90
85
85
80
VIN = 18V
75
1.4
1.6
1.8
2
80
VIN = 18V
75
VIN = 24V
70
70
VIN = 36V
VIN = 36V
65
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
65
2.5
0.2
0.4
0.6
Output Current (Amps)
0.8
UHE-12/2500-D48 Efficiency vs. Load @ +25°C Ambient
95
90
90
85
85
80
VIN = 36V
75
1.2
1.4
1.6
1.8
2
UHE-15/2000-D48 Efficiency vs. Load @ +25°C Ambient
80
VIN = 36V
75
VIN = 48V
VIN = 48V
70
70
VIN = 75V
VIN = 75V
65
0.25
1
Output Current (Amps)
Efficiency (%)
Efficiency (%)
1.2
UHE-15/2000-D24 Efficiency vs. Load @ +25°C Ambient
VIN = 24V
95
1
Output Current (Amps)
Efficiency (%)
Efficiency (%)
95
0.2
0.5
0.75
1
1.25
1.5
1.75
Output Current (Amps)
2
2.25
2.5
65
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
Output Current (Amps)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 8 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
95
UHE-12-2500-Q48 Efficiency vs. Load @ +25°C Ambient
95
90
85
Efficiency (%)
Efficiency (%)
90
UHE-15-2000-Q48 Efficiency vs. Load @ +25°C Ambient
VIN = 18V
80
VIN = 48V
75
85
80
VIN = 18V
75
VIN = 48V
VIN = 75V
70
70
VIN = 75V
65
0.25
0.5
0.75
1
1.25
1.5
1.75
2
2.25
65
2.5
0.2
0.4
0.6
0.8
Output Current (Amps)
UHE-1.2/10000-D24 and UHE-1.5/10000-D24 Temperature Derating
1.8
2
24VIN, STILL AIR
8
8
24VIN, 150LFM
24VIN, 150LFM
7
Output Ciurrent (Amps)
Output Ciurrent (Amps)
1.6
9
24VIN, STILL AIR
24VIN, 300LFM
6
5
4
3
7
24VIN, 300LFM
6
5
4
3
2
2
1
1
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
0
100
–40
0
40
45
50
Ambient Temperature (°C)
55
60
65
70
75
80
85
90
95
100
80
85
90
95
100
Ambient Temperature (°C)
UHE-1.2/10000-D48 and UHE-1.5/10000-D48 Temperature Derating
UHE-1.8/10000-D48 Temperature Derating
10
10
9
9
75VIN, STILL AIR
48VIN, STILL AIR
8
8
48VIN, STILL AIR
48VIN, 150LFM
7
Output Ciurrent (Amps)
Output Ciurrent (Amps)
1.4
10
9
48VIN, 300LFM
6
5
4
3
7
75VIN, 150LFM
6
48VIN, 150LFM
5
48VIN, 300LFM
4
3
2
2
1
1
0
1.2
UHE-1.8/10000-D24 Temperature Derating
10
0
1
Output Current (Amps)
–40
0
40
45
50
55
60
65
70
75
Ambient Temperature (°C)
80
85
90
95
100
0
–40
0
40
45
50
55
60
65
70
75
Ambient Temperature (°C)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 9 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
UHE-5/5000-Q12 Temperature Derating
UHE-2.5/10000-D48 Temperature Derating
25
30
36VIN, STILL AIR
20
20
Output Power (Watts)
Output Power (Watts)
25
NATURAL CONVECTION
15
10
24VIN, STILL AIR
36VIN, 150LFM
15
24VIN, 150LFM
36VIN, 300LFM
10
24VIN, 300LFM
5
5
0
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
–40
100
0
40
45
50
55
60
65
70
75
80
85
90
95
100
Ambient Temperature (°C)
Ambient Temperature (°C)
UHE-3.3/7500-Q48 Maximum Current Temperature Derating
(VIN = 48V, airflow = 300 LFM)
UHE-3.3/7500-Q12 Temperature Derating
25
8
36VIN, STILL AIR
7
20
24VIN, STILL AIR
15
Output Power (Watts)
Output Power (Watts)
6
36VIN, 150LFM
24VIN, 150LFM
36VIN, 300LFM
10
24VIN, 300LFM
5
300 LFM
5
4
3
2
1
0
40
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
50
100
60
70
80
90
100
90
100
Ambient Temperature (°C)
Ambient Temperature (°C)
UHE-5/5000-Q48 Maximum Current Temperature Derating
(VIN = 48V, airflow = 300 LFM)
UHE-3.3/7500-D48 Temperature Derating
30
6
5
25
Output Power (Watts)
Output Power (Watts)
75VIN, STILL AIR
48VIN, STILL AIR
20
36VIN, STILL AIR
15
75VIN, 150LFM
75VIN, 300LFM
10
4
300 LFM
3
2
1
5
0
40
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
50
60
70
80
Ambient Temperature (°C)
Ambient Temperature (°C)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 10 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Typical Performance Curves
UHE-5/6000-D48 Temperature Derating
UHE-12/2500 and UHE-15/2000 (All Models) Temperature Derating
30
30
12VIN, STILL AIR
75VIN, STILL AIR
25
25
48VIN, STILL AIR
24VIN, STILL AIR
(48VIN, Still Air for Q48 Models Only)
20
Output Power (Watts)
Output Power (Watts)
36VIN, STILL AIR
75VIN, 150LFM
75VIN, 300LFM
15
10
5
0
20
48VIN, STILL AIR
(D48 Models Only)
15
10
5
–40
0
40
45
50
55
60
65
70
75
Ambient Temperature (°C)
80
85
90
95
100
0
–40
0
40
45
50
55
60
65
70
75
80
85
90
95
100
Ambient Temperature (°C)
www.murata-ps.com/support
MDC_UHE_12-30W Series.D05 Page 11 of 16
UHE Series
Isolated, High Efficiency, 1.6" × 2"
2-10 Amp, 12-30 Watt DC/DC Converters
Input Undervoltage Shutdown and Start-Up Threshold
Under normal start-up conditions, devices will not begin to regulate until
the ramping-up input voltage exceeds the Start-Up Threshold Voltage. Once
operating, devices will not turn off until the input voltage drops below the
Undervoltage Shutdown limit. Subsequent re-start will not occur until the input
is brought back up to the Start-Up Threshold. This built in hysteresis prevents
any unstable on/off situations from occurring at a single input voltage.
Absolute Maximum Ratings
Input Voltage:
Continuous:
D12 Models
D24/Q12 Models
D48/Q48 Models
Transient (100msec):
D12 Models
D24/Q12 Models
D48/Q48 Models
23 Volts
42 Volts
81 Volts
25 Volts
50 Volts
100 Volts
On/Off Control (pin 4) Max. Voltages
Referenced to –Input (pin 2)
No Suffix
"N" Suffix
+15 Volts
+7 Volts
Input Reverse-Polarity Protection
Current must be