0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
UWQ-12/17-Q48PB-C

UWQ-12/17-Q48PB-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    DIP5

  • 描述:

    DC/DC CONVERTER 12V 17A BRICK

  • 数据手册
  • 价格&库存
UWQ-12/17-Q48PB-C 数据手册
UWQ-12/17-Q48 Series www.murata-ps.com Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PRODUCT OVERVIEW Typical unit FEATURES  Fixed DC outputs, 12V @17A  Industry standard quarter brick 2.3” x 1.45” x 0.46” open frame package  Wide range 18 to 75 Vdc input voltages with 2250 Volt Basic isolation  Remote ON/Off enable control The UWQ series offers high output current (up to 17 Amps) in an industry standard “quarter brick” package requiring no heat sink for most applications. The UWQ series delivers fixed DC output voltages up to 204 Watts (12V @17A) for printed circuit board mounting. Wide range inputs of 18 to 75 Volts DC (48 Volts nominal) are ideal for datacom and telecom systems. Advanced automated surface mount assembly and planar magnetics deliver galvanic isolation rated at 2250 Vdc for basic insulation. To power digital systems, the outputs offer fast settling to current steps and tolerance of higher capacitive loads. Excellent ripple and noise specifications assure compatibility to CPU’s, ASIC’s, programmable logic and FPGA’s. No minimum load is required. For systems needing controlled startup/shutdown, an external remote On/Off control may use either positive or negative logic. A wealth of self-protection features include input undervoltage lockout and overtemperature shutdown using an on-board temperature sensor; overcurrent protection using the “hiccup” autorestart technique, provides indefinite short-circuit protection, along with output OVP. The synchronous rectifier topology offers high efficiency for minimal heat generation and “no heat sink” operation. The UWQ series is certified to safety standards UL/ EN/IEC/CSA 60950-1, 2nd edition. It meets RFI/ EMI conducted/radiated emission compliance to EN55022, CISPR22 with an external filter.  DOSA-compatible pinouts and form factor  High efficiency synchronous rectifier topology  Stable no-load operation  Monotonic startup into pre-bias output condition  Certified to UL/EN 60950-1, CSA-C22.2 No. 60950-1, 2nd edition safety approvals  Extensive self-protection, OVP, input undervoltage, current limiting and thermal shutdown F1 APPLICATIONS  Embedded systems, datacom and telecom installations, wireless base stations  Disk farms, data centers and cellular repeater sites  Remote sensor systems, dedicated controllers  Instrumentation systems, R&D platforms, automated test fixtures  Data concentrators, voice forwarding and speech processing systems +Vin (1) +Vout (8) Barrier External DC Power Source On/Off Control (2) Controller and Power Open = On Reference and Error Amplifier logic) -Vin (3) -Vout (4) Figure 1. Connection Diagram Typical topology is shown. Murata Power Solutions recommends an external fuse. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 1 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ Output Root Model ➀ UWQ-12/17-Q48 ➂ Input R/N (mV IOUT IIN full pk-pk) Regulation (Max.) ➁ VOUT (Amps, Power VIN Nom. Range IIN no load (Volts) max.) (Watts) Typ. Max. Line Load (Volts) (Volts) load (mA) (Amps) 12 17 204 100 120 ±1% ±1.5% 48 18-75 ➀ Please refer to the part number structure for additional ordering information and options. ➁ All specifications are typical at nominal line voltage and full load, +25°C unless otherwise noted. See 80 4.62 Efficiency Dimensions Min. Typ. (inches) 90% 92% 2.30x1.45x0.46 max. 58.4x36.8x11.7 (mm) detailed specifications. Output capacitors are 1 μF || 10 μF with a 22μF input capacitor. These caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE UWQ - 12 / 17 - Q48 N B S Lx - C Family Series: Wide Input Quarter Brick Nominal Output Voltage Maximum Rated Output: Current in Amps Input Voltage Range: Q48 = 18-75 Volts (48V nominal) On/Off Control Logic N = Negative logic P = Positive logic RoHS Hazardous Materials compliance C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard Pin length option Blank = Standard pin length 0.180 in. (4.6 mm) L1 = 0.110 in. (2.79 mm)* L2 = 0.145 in. (3.68 mm)* *Minimum order quantity is required. Load Share Option Blank = No share S = Load share Baseplate (optional) Blank = No baseplate, standard B = Baseplate installed, optional Samples available with standard pin length only. Note: Some model number combinations may not be available. See website or contact your local Murata sales representative. UWQ-12/17-Q48NBL1-C Complete Model Number Example: Negative On/Off logic, baseplate installed, 0.110˝ pin length, RoHS-6 compliance www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 2 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters FUNCTIONAL SPECIFICATIONS Conditions ➀ ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Full power operation Operating or non-operating, 100 mS max. duration Input to output None, install external fuse Power on or off, referred to -Vin Input Voltage, Transient Isolation Voltage Input Reverse Polarity On/Off Remote Control Output Power Minimum 18 Typical/Nominal 48 Maximum 80 Vdc 100 Vdc 2250 Vdc Vdc Vdc W None 0 0 Units 13.5 210 Current-limited, no damage, 0 17 A short-circuit protected Storage Temperature Range Vin = Zero (no power) -55 125 °C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended. Output Current Conditions ➀ ➂ INPUT Operating voltage range Recommended External Fuse Start-up threshold, measured at 50% load Undervoltage shutdown, measured at 50% load Overvoltage protection Reverse Polarity Protection Internal Filter Type Input current Full Load Conditions Low Line Inrush Transient Output in Short Circuit No Load input current Shut down mode input current Reflected (back) ripple current ➁ Back Ripple Current, No Filtering Back Ripple Current, with 22μF external input capacitor Pre-biased startup 18 Fast blow Rising input voltage Falling input voltage Rising input voltage None, install external fuse; see technical notes 16.5 15 Vin = nominal Vin = minimum Vin = 48V. Iout = minimum, unit=ON Measured at input with specified filter External output voltage < Vset 48 20 17.5 16 None None L-C 75 17.9 17 Vdc A Vdc Vdc Vdc Vdc 4.52 12.06 0.05 50 80 5 15 500 4.76 12.69 TBD 100 150 6.5 25 525 A A A2-Sec. mA mA mA mA, RMS mA-p-p 300 400 mA-p-p Monotonic GENERAL and SAFETY Efficiency Isolation Isolation Voltage, input to output Isolation Voltage, input to baseplate Isolation Voltage, output to baseplate Insulation Safety Rating Isolation Resistance Isolation Capacitance Safety (certified to the following requirements) Calculated MTBF Vin=48V, full load Vin=18V 90 90 With or without baseplate With baseplate With baseplate 2250 1500 1500 92 92 % % Vdc Vdc Vdc basic 100 1500 UL-60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1, 2nd edition Per Telcordia SR-332, issue 1, class 3, ground fixed, Tambient=+25°C MΩ pF Yes Hours x 103 TBC DYNAMIC CHARACTERISTICS Fixed Switching Frequency Startup Time Startup Time Dynamic Load Response Dynamic Load Peak Deviation 160 Power On, to Vout regulation band, 100% resistive load Remote ON to Vout Regulated 50-75-50% load step to 3% error band same as above 180 200 KHz 60 65 mS 60 220 ±1100 65 275 ±1300 mS μSec mV 1 1 13.5 2 Vdc Vdc mA 13.5 1 2 V V mA FEATURES and OPTIONS Remote On/Off Control ➃ “N” suffix: Negative Logic, ON state Negative Logic, OFF state Control Current “P” suffix: Positive Logic, ON state Positive Logic, OFF state Control Current Base Plate ON = pin grounded or external voltage OFF = pin open or external voltage open collector/drain 0 3.5 ON = pin open or external voltage OFF = ground pin or external voltage open collector/drain "B" suffix 3.5 0 1 optional www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 3 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters FUNCTIONAL SPECIFICATIONS, (CONT.) Conditions ➀ OUTPUT Total Output Power Voltage Setting Accuracy, fixed output Overvoltage Protection Current Output Current Range Minimum Load Current Limit Inception Short Circuit Short Circuit Current Short Circuit Duration (remove short for recovery) Short circuit protection method Regulation ➄ Line Regulation Load Regulation Ripple and Noise ➅ Temperature Coefficient Maximum Capacitive Loading At 50% load, not user adjustable Via magnetic feedback 97% of Vnom., cold condition Minimum Typical/Nominal Units 204 210 W 11.64 12 12.36 15 Vdc Vdc 0.0 17 No minimum load 21 17 A 23 A 5 6 A ±0.65 ±1.5 % of Vout % of Vout 19 Hiccup technique, autorecovery within 1.25% of Vout Output shorted to ground, no damage Continuous Hiccup current limiting Non-latching Vin=min. to max., Vout=nom., full load Iout=min. to max., Vin=nom. 5 Hz- 20 MHz BW, Cout=1μF MLCC paralleled with 10μF tantalum At all outputs Full resistive load, low ESR Maximum 0.0 100 0 120 mV pk-pk 0.02 5000 % of Vout./°C μF 2.3x1.45x0.46 max. 58.4x36.8x11.68 2.3x1.45x0.5 58.4x36.8x12.7 1.6 45 2.24 63.5 0.04 & 0.06 1.016 & 1.52 Copper alloy 50 5 Aluminum Inches mm Inches mm Ounces Grams Ounces Grams Inches mm MECHANICAL (Through Hole Models) Outline Dimensions (no baseplate) (Please refer to outline drawing) Outline Dimensions (with baseplate) Weight LxWxH No baseplate No baseplate With baseplate With baseplate Through Hole Pin Diameter Through Hole Pin Material TH Pin Plating Metal and Thickness Nickel subplate Gold overplate Baseplate Material μ-inches μ-inches ENVIRONMENTAL Operating Ambient Temperature Range Operating Case Temperature Storage Temperature Thermal Protection/Shutdown Electromagnetic Interference Conducted, EN55022/CISPR22 Radiated, EN55022/CISPR22 RoHS rating Notes See derating curves With baseplate, no derating Vin = Zero (no power) Measured in center External filter is required ➀ Unless otherwise noted, all specifications apply at Vin = nominal, nominal output voltage and full output load. General conditions are near sea level altitude, no base plate installed and natural convection airflow unless otherwise specified. All models are tested and specified with external parallel 1 μF and 10 μF multi-layer ceramic output capacitors and a 22μF external input capacitor (see Technical Notes). All capacitors are low-ESR types wired close to the converter. These capacitors are necessary for our test equipment and may not be needed in the user’s application. ➁ Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 33 μF/100V, Cbus = 220μF/100V and Lbus = 12 μH. -40 -40 -55 115 125 B B RoHS-6 85 110 125 130 °C °C °C °C Class Class ➂ All models are stable and regulate to specification under no load. ➃ The Remote On/Off Control is referred to -Vin. ➄ Regulation specifications describe the output voltage changes as the line voltage or load current is varied from its nominal or midpoint value to either extreme. The load step is ±25% of full load current. ➅ Output Ripple and Noise is measured with Cout = 1 μF || 10 μF, 20 MHz oscilloscope bandwidth and full resistive load. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 4 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C 94 92 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 Maximum Current Temperature Derating at sea level (Vin = 24V, air flow from Pin 1 to Pin 4 on PCB, with baseplate) 18 17 16 VIN = 18V VIN = 24V VIN = 36V VIN = 48V VIN = 60V VIN = 75V Output Current (Amps) Efficiency (%) Efficiency vs. Line Voltage and Load Current @ +25°C 15 14 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 13 12 11 10 9 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 30 17 35 40 45 18 18 17 17 16 16 15 15 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 12 11 65 70 75 80 85 80 85 80 85 14 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 13 12 11 10 10 9 9 8 8 30 35 40 45 50 55 60 65 70 75 80 85 30 35 40 45 Ambient Temperature (°C) 50 55 60 65 70 75 Ambient Temperature (°C) Maximum Current Temperature Derating at sea level (Vin = 60V, air flow from Pin 1 to Pin 4 on PCB, with baseplate) Maximum Current Temperature Derating at sea level (Vin = 75V, air flow from Pin 1 to Pin 4 on PCB, with baseplate) 18 18 17 16 16 14 15 Output Current (Amps) Output Current (Amps) 60 Maximum Current Temperature Derating at sea level (Vin = 48V, air flow from Pin 1 to Pin 4 on PCB, with baseplate) Output Current (Amps) Output Current (Amps) Maximum Current Temperature Derating at sea level (Vin = 36V, air flow from Pin 1 to Pin 4 on PCB, with baseplate) 13 55 Ambient Temperature (°C) Load Current (Amps) 14 50 14 13 12 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 11 10 9 12 10 8 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 6 4 2 8 30 35 40 45 50 55 60 65 Ambient Temperature (°C) 70 75 80 85 30 35 40 45 50 55 60 65 70 75 Ambient Temperature (°C) www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 5 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Maximum Current Temperature Derating at sea level Vin = 36V (air flow from Pin 1 to Pin 4 on PCB), no baseplate 18 18 17 17 16 16 15 15 Output Current (Amps) Output Current (Amps) Maximum Current Temperature Derating at sea level Vin = 24V (air flow from Pin 1 to Pin 4 on PCB), no baseplate 14 13 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 12 11 10 14 13 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 12 11 10 9 9 8 8 30 35 40 45 50 55 60 65 70 75 80 85 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Ambient Temperature (°C) Stepload Transient Response (Vin=48V, Iout=50-75-50% of Imax, Cload=1μF || 10μF, Io=10A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout Maximum Current Temperature Derating at sea level (Vin = 48V, air flow from Pin 1 to Pin 4 on PCB, no baseplate) 18 17 Output Current (Amps) 16 15 14 13 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 12 11 10 9 8 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Stepload Transient Response (Vin=48V, Iout=25-75-25% of Imax, Cload=1μF || 10μF, Io=5A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout Stepload Transient Response (Vin=48V, Iout=50-75-50% of Imax, Cload=5000μF, Io=5A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 6 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Start-up Delay (Vin=48V, Iout=0A, Cload=0, Ta=+25°C) Ch1= Vin, Ch2= Vout Start-up Delay (Vin=48V, Iout=17A, Cload=0, Ta=+25°C) Ch1= Vin, Ch2= Vout Start-up Delay (Vin=48V, Iout=17A, Cload=5000μF, Ta=+25°C) Ch1= Vin, Ch2= Vout On/Off Enable Delay (Vin=48V, Vout=nom, Iout=0A, Ta=+25°C) Ch1= Enable, Ch2= Vout. On/Off Enable Delay (Vin=48V, Vout=nom, Iout=17A, Ta=+25°C) Ch1= Enable, Ch2= Vout. On/Off Enable Delay (Vin=48V, Vout=nom, Iout=17A, Cload=5000μF, Ta=+25°C) Ch1= Enable, Ch2= Vout. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 7 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Output ripple and Noise (Vin=48V, Iout=0A, Cload= 1μF || 10μF, Ta=+25°C, BW=20Mhz) Output ripple and Noise (Vin=48V, Iout=17A, Cload= 1μF || 10μF, Ta=+25°C, BW=20Mhz) Thermal image with hot spot at 9.56A with 25°C ambient temperature. Natural convention is used with no forced airflow. Identifiable and recommended maximum value to be verified in application. Vin=48V, Q5 max temp=128°C/IPC9592 guidelines. (+Vin) (+Vo) (-Vin) (-Vo) www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 8 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters MECHANICAL SPECIFICATIONS (OPEN FRAME) TOP VIEW END VIEW END VIEW 58.4 2.30 4.78 0.188* [11.68] 0.46 36.8 1.45 1° MAX (ALL PINS) 0.26 0.010 MIN BOTTOM CLEARANCE Mtg Plane SIDE VIEW *Alternate pin lengths available (Contact Murata Power Solutions for information). Pin location dimensions apply at circuit board level. .062 SHOULDER (AT 40 MIL PINS) MATERIAL: .040 PINS: COPPER ALLOY .060 PINS: COPPER ALLOY .083 SHOULDER (AT 60 MIL PINS) 1.02±0.05 0.040±.002 @ PINS 1-3, 9 FINISH: (ALL PINS) GOLD (5u"MIN) OVER NICKEL (50u" MIN) 1.52±0.05 0.060±.002 @ PINS 4 & 8 50.80 2.000 REF 50.80 2.000 3.8 0.15 7.61 0.300 CL 3 4 15.24 0.600 2 1 8 BOTTOM VIEW Dimensions are in inches (mm) shown for ref. only. Third Angle Projection I/O Connections (pin side view) Pin 1 2 3 Function +Vin Remote On/Off Control -Vin Pin 4 Function -Vout 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 9 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters MECHANICAL SPECIFICATIONS (BASEPLATE) 4x M3x0.5 THREADED HOLE (.10 MAX SCREW PENETRATION) TOP VIEW 58.4 2.30 END VIEW END VIEW 12.7 0.50 47.24 1.860 4.78 0.188* 36.8 1.45 1° MAX (ALL PINS) 26.16 1.030 0.26 0.010 MIN BOTTOM CLEARANCE Mtg Plane SIDE VIEW OPTIONAL BASEPLATE 'B' OPTION *Alternate pin lengths available (Contact Murata Power Solutions for information). Pin location dimensions apply at circuit board level. .062 SHOULDER (AT 40 MIL PINS) MATERIAL: .040 PINS: COPPER ALLOY .060 PINS: COPPER ALLOY .083 SHOULDER (AT 60 MIL PINS) 1.02±0.05 0.040±.002 @ PINS 1-3, 9 FINISH: (ALL PINS) GOLD (5u"MIN) OVER NICKEL (50u" MIN) 1.52±0.05 .060±.002 @ PINS 4 & 8 50.80 2.000 REF 3.8 0.15 50.80 2.000 7.61 0.300 3 CL 4 15.24 0.600 2 1 8 BOTTOM VIEW Dimensions are in inches (mm) shown for ref. only. Third Angle Projection I/O Connections (pin side view) Pin 1 2 3 Function +Vin Remote On/Off Control -Vin Pin 4 Function -Vout 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 10 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters RECOMMENDED FOOTPRINT Recommended Footprint (view through converter) REF: DOSA Standard Specification for Quarter-Brick DC/DC Converters FINISHED HOLE SIZES @ PINS 1-3 TOP VIEW (PER IPC-D-275, LEVEL C) 0.048-0.062 CL (PRI) (SEC) 1 37.3 1.47 CL 8 7.62 0.300 2 7.62 0.300 4 3 CL FINISHED HOLE SIZES @ PINS 4 & 8 0.100 MIN @ 1-4, 8 FOR PIN SHOULDERS (PER IPC-D-275, LEVEL C) 25.4 1.00 0.070-0.084 50.80 2.000 58.9 2.32 It is recommended that no parts be placed beneath converter (hatched area). Dimensions are in inches (mm) shown for ref. only. Third Angle Projection I/O Connections (pin side view) Pin 1 2 3 Function +Vin Remote On/Off Control -Vin Pin 4 Function -Vout 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 11 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters STANDARD PACKAGING 9.92 (251.97) REF 9.92 (251.97) REF Each static dissipative polyethylene foam tray accommodates 15 converters in a 3 x 5 array. 0.88 (22.35) REF 2.75 (69.85) ±.25 closed height 11.00 (279.4) ±.25 10.50 (266.7) ±.25 Carton accommodates two (2) trays yielding 30 converters per carton Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 12 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters TECHNICAL NOTES Input Fusing Certain applications and/or safety agencies may require fuses at the inputs of power conversion components. Fuses should also be used when there is the possibility of sustained input voltage reversal which is not current-limited. For greatest safety, we recommend a fast blow fuse installed in the ungrounded input supply line. The installer must observe all relevant safety standards and regulations. For safety agency approvals, install the converter in compliance with the end-user safety standard. Input Reverse-Polarity Protection If the input voltage polarity is reversed, an internal diode will become forward biased and likely draw excessive current from the power source. If this source is not current-limited or the circuit appropriately fused, it could cause permanent damage to the converter. Input Under-Voltage Shutdown and Start-Up Threshold Under normal start-up conditions, converters will not begin to regulate properly until the rising input voltage exceeds and remains at the Start-Up Threshold Voltage (see Specifications). Once operating, converters will not turn off until the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a single input voltage. Users should be aware however of input sources near the Under-Voltage Shutdown whose voltage decays as input current is consumed (such as capacitor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the operating input voltage is well above the UV Shutdown voltage AT ALL TIMES. Start-Up Delay Assuming that the output current is set at the rated maximum, the Vin to Vout StartUp Delay (see Specifications) is the time interval between the point when the rising input voltage crosses the Start-Up Threshold and the fully loaded regulated output voltage enters and remains within its specified regulation band. Actual measured times will vary with input source impedance, external input capacitance, input voltage slew rate and final value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of the PWM controller at power up, thereby limiting the input inrush current. The On/Off Remote Control interval from inception to VOUT regulated assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specified regulation band. The specification assumes that the output is fully loaded at maximum rated current. Input Source Impedance These converters will operate to specifications without external components, assuming that the source voltage has very low impedance and reasonable input voltage regulation. Since real-world voltage sources have finite impedance, performance is improved by adding external filter components. Sometimes only a small ceramic capacitor is sufficient. Since it is difficult to totally characterize all applications, some experimentation may be needed. Note that external input capacitors must accept high speed switching currents. Because of the switching nature of DC/DC converters, the input of these converters must be driven from a source with both low AC impedance and adequate DC input regulation. Performance will degrade with increasing input inductance. Excessive input inductance may inhibit operation. The DC input regulation specifies that the input voltage, once operating, must never degrade below the Shut-Down Threshold under all load conditions. Be sure to use adequate trace sizes and mount components close to the converter. I/O Filtering, Input Ripple Current and Output Noise All models in this converter series are tested and specified for input reflected ripple current and output noise using designated external input/output components, circuits and layout as shown in the figures below. External input capacitors (CIN in the figure) serve primarily as energy storage elements, minimizing line voltage variations caused by transient IR drops in the input conductors. Users should select input capacitors for bulk capacitance (at appropriate frequencies), low ESR and high RMS ripple current ratings. In the figure below, the CBUS and LBUS components simulate a typical DC voltage bus. Your specific system configuration may require additional considerations. Please note that the values of CIN, LBUS and CBUS may vary according to the specific converter model. TO OSCILLOSCOPE CURRENT PROBE +VIN VIN + – + – LBUS CBUS CIN −VIN CIN = 33μF, ESR < 200mΩ @ 100kHz CBUS = 220μF, 100V LBUS = 12μH Figure 2. Measuring Input Ripple Current In critical applications, output ripple and noise (also referred to as periodic and random deviations or PARD) may be reduced by adding filter elements such as multiple external capacitors. Be sure to calculate component temperature rise from reflected AC current dissipated inside capacitor ESR. Floating Outputs Since these are isolated DC/DC converters, their outputs are “floating” with respect to their input. The essential feature of such isolation is ideal ZERO CURRENT FLOW between input and output. Real-world converters however do exhibit tiny leakage currents between input and output (see Specifications). These leakages consist of both an AC stray capacitance coupling component and a DC leakage resistance. When using the isolation feature, do not allow the isolation voltage to exceed specifications. Otherwise the converter may be damaged. Designers will normally use the negative output (-Output) as the ground return of the load circuit. You can however use the positive output (+Output) as the ground return to effectively reverse the output polarity. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 13 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters CAUTION: If you exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected near Sea Level altitude. Be sure to reduce the derating for higher altitude. +VOUT C1 C2 SCOPE RLOAD −VOUT C1 = 1μF C2 = 10μF LOAD 2-3 INCHES (51-76mm) FROM MODULE Figure 3. Measuring Output Ripple and Noise (PARD) Minimum Output Loading Requirements These converters employ a synchronous rectifier design topology. All models regulate within specification and are stable under no load to full load conditions. Operation under no load might however slightly increase output ripple and noise. Thermal Shutdown To protect against thermal over-stress, these converters include thermal shutdown circuitry. If environmental conditions cause the temperature of the DC/ DC’s to rise above the Operating Temperature Range up to the shutdown temperature, an on-board electronic temperature sensor will power down the unit. When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of hysteresis to prevent rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test your application to avoid unplanned thermal shutdown. Temperature Derating Curves The graphs in this data sheet illustrate typical operation under a variety of conditions. The Derating curves show the maximum continuous ambient air temperature and decreasing maximum output current which is acceptable under increasing forced airflow measured in Linear Feet per Minute (“LFM”). Note that these are AVERAGE measurements. The converter will accept brief increases in temperature and/or current or reduced airflow as long as the average is not exceeded. Note that the temperatures are of the ambient airflow, not the converter itself which is obviously running at higher temperature than the outside air. Also note that “natural convection” is defined as very low flow rates which are not using fan-forced airflow. Depending on the application, “natural convection” is usually about 30-65 LFM but is not equal to still air (0 LFM). Murata Power Solutions makes Characterization measurements in a closed cycle wind tunnel with calibrated airflow. We use both thermocouples and an infrared camera system to observe thermal performance. As a practical matter, it is quite difficult to insert an anemometer to precisely measure airflow in most applications. Sometimes it is possible to estimate the effective airflow if you thoroughly understand the enclosure geometry, entry/exit orifice areas and the fan flowrate specifications. Output Overvoltage Protection (OVP) This converter monitors its output voltage for an over-voltage condition using an on-board electronic comparator. The signal is optically coupled to the primary side PWM controller. If the output exceeds OVP limits, the sensing circuit will power down the unit, and the output voltage will decrease. After a time-out period, the PWM will automatically attempt to restart, causing the output voltage to ramp up to its rated value. It is not necessary to power down and reset the converter for this automatic OVP-recovery restart. If the fault condition persists and the output voltage climbs to excessive levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling is referred to as “hiccup” mode. Output Fusing The converter is extensively protected against current, voltage and temperature extremes. However, your application circuit may need additional protection. In the extremely unlikely event of output circuit failure, excessive voltage could be applied to your circuit. Consider using an appropriate external protection. Current Limiting (Power limit with current mode control) As power demand increases on the output and enters the specified “limit inception range” (current in voltage mode and power in current mode) limiting circuitry activates in the DC-DC converter to limit/restrict the maximum current or total power available. In voltage mode, current limit can have a “constant or foldback” characteristic. In current mode, once the current reaches a certain range the output voltage will start to decrease while the output current continues to increase, thereby maintaining constant power, until a maximum peak current is reached and the converter enters a “hiccup” (on off cycling) mode of operation until the load is reduced below the threshold level, whereupon it will return to a normal mode of operation. Current limit inception is defined as the point where the output voltage has decreased by a pre-specified percentage (usually a 2% decrease from nominal). Short Circuit Condition (Current mode control) The short circuit condition is an extension of the “Current Limiting” condition. When the monitored peak current signal reaches a certain range, the PWM controller’s outputs are shut off thereby turning the converter “off.” This is followed by an extended time out period. This period can vary depending on other conditions such as the input voltage level. Following this time out period, the PWM controller will attempt to re-start the converter by initiating a “normal start cycle” which includes softstart. If the “fault condition” persists, another “hiccup” cycle is initiated. This “cycle” can and will continue indefinitely until such time as the “fault condition” is removed, at which time the converter will resume “normal operation.” Operating in the “hiccup” mode during a fault condition is advantageous in that average input and output power levels are held low preventing excessive internal increases in temperature. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 14 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Remote On/Off Control On the input side, a remote On/Off Control can be specified with either positive or negative logic as follows: Positive: Models equipped with positive logic are enabled when the On/Off pin is left open or is pulled high to +13.5VDC with respect to –VIN. An internal bias current causes the open pin to rise to +VIN. Positive-logic devices are disabled when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to –VIN. Negative: Models with negative logic are on (enabled) when the On/Off is grounded or brought to within a low voltage (see Specifications) with respect to –VIN. The device is off (disabled) when the On/Off is left open or is pulled high to +13.5VDC Max. with respect to –VIN. Dynamic control of the On/Off function should be able to sink the specified signal current when brought low and withstand specified voltage when brought high. Be aware too that there is a finite time in milliseconds (see Specifications) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. +VCC ON/OFF CONTROL -VIN Figure 4. Driving the On/Off Control Pin (suggested circuit) There are two CAUTIONs for the On/Off Control: CAUTION: While it is possible to control the On/Off with external logic if you carefully observe the voltage levels, the preferred circuit is either an open drain/open collector transistor or a relay (which can thereupon be controlled by logic). The On/Off prefers to be set at approx. +13.5V (open pin) for the ON state, assuming positive logic. CAUTION: Do not apply voltages to the On/Off pin when there is no input power voltage. Otherwise the converter may be permanently damaged. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 15 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Emissions Performance Murata Power Solutions measures its products for radio frequency emissions against the EN 55022 and CISPR 22 standards. Passive resistance loads are employed and the output is set to the maximum voltage. If you set up your own emissions testing, make sure the output load is rated at continuous power while doing the tests. [3] Conducted Emissions Test Results [[4] [4 4] La Layo yoout R eeccom mm meennddat atio ionnss Layout Recommendations The recommended external input and output capacitors (if required) are included. Please refer to the fundamental switching frequency. All of this information is listed in the Product Specifications. An external discrete filter is installed and the circuit diagram is shown below. UWQ EMI 200W Test Card 48Vdc in, 12Vout, 17Amps Resistive Load UUT V+ Black C16 C8 C17 C8 C8 C8 L3 C8 C8 C7 Vin + Vout + Vin - Vout - Resistive Load inside a metal container L1 V- Graph 1. Conducted emissions performance, CISPR/EN55022, Class B, full load Most applications can use the filtering which is already installed inside the converter or with the addition of the recommended external capacitors. For greater emissions suppression, consider additional filter components and/or shielding. Emissions performance will depend on the user’s PC board layout, the chassis shielding environment and choice of external components. Please refer to Application Note GEAN02 for further discussion. Figure 5. Conducted Emissions Test Circuit [1] Conducted Emissions Parts List Reference Part Number L1 L3 C8 PE-62913 500uH,10A, MPS C7 VZ Series C16, C17 Description 1mH, 6A 500uH,10A 2.2μFd Qty 2 - Electrolytic Capacitor 22μFd, 100V .22μFd Vendor Pulse Murata Murata Since many factors affect both the amplitude and spectra of emissions, we recommend using an engineer who is experienced at emissions suppression. Panasonic Unknown [2] Conducted Emissions Test Equipment Used Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC Rohde & Schwarz Software ESPC-1 Ver. 2.20 HP11947A Transient Limiter (Agilent) OHMITE 25W – Resistor combinations DC Source Programmable DC Power Supply Model 62012P-100-50 www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 16 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Vertical Wind Tunnel IR Transparent optical window Variable speed fan Unit under test (UUT) Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airflow and heat dissipation analysis of power products. The system includes a precision low flow-rate anemometer, variable speed fan, power supply input and load controls, temperature gauges, and adjustable heating element. The IR camera monitors the thermal performance of the Unit Under Test (UUT) under static steady-state conditions. A special optical port is used which is transparent to infrared wavelengths. IR Video Camera Heating element Precision low-rate anemometer 3” below UUT Both through-hole and surface mount converters are soldered down to a host carrier board for realistic heat absorption and spreading. Both longitudinal and transverse airflow studies are possible by rotation of this carrier board since there are often significant differences in the heat dissipation in the two airflow directions. The combination of adjustable airflow, adjustable ambient heat, and adjustable Input/ Output currents and voltages mean that a very wide range of measurement conditions can be studied. The collimator reduces the amount of turbulence adjacent to the UUT by minimizing airflow turbulence. Such turbulence influences the effective heat transfer characteristics and gives false readings. Excess turbulence removes more heat from some surfaces and less heat from others, possibly causing uneven overheating. Ambient temperature sensor Airflow collimator Both sides of the UUT are studied since there are different thermal gradients on each side. The adjustable heating element and fan, built-in temperature gauges, and no-contact IR camera mean that power supplies are tested in real-world conditions. Figure 6. Vertical Wind Tunnel Soldering Guidelines Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: For Sn/Pb based solders: Maximum Preheat Temperature 115° C. Maximum Preheat Temperature 105° C. Maximum Pot Temperature 270° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 7 seconds Maximum Solder Dwell Time 6 seconds Murata Power Solutions, Inc. 129 Flanders Road, Westborough, MA 01581 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2018 Murata Power Solutions, Inc. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 17 of 17
UWQ-12/17-Q48PB-C 价格&库存

很抱歉,暂时无法提供与“UWQ-12/17-Q48PB-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货