UWR 26-40W Series
www.murata-ps.com
Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters
FEATURES
Standard 2" x 2" packages/pinouts
Output voltages/currents:
•
3.3 Volts @ 8/9 Amps
•
5 Volts @ 7/8 Amps
Choice of 3 input voltage ranges:
10-18V, 18-36V, 36-75V
Fully synchronous forward topology
Outstanding performance:
•
±1% setpoint accuracy
•
Efficiencies to 90%
•
Noise as low as 75mVp-p
•
Stable no-load operation
On/off control and VOUT trim pins
Fully isolated (1500Vdc); I/O protected
Thermal shutdown
Designed to meet UL/EN/IEC60950-1
certification; CE marked
PRODUCT OVERVIEW
The newest products in Murata Power Solutions' flagship A-Series are the UWR, 26-40
Watt isolated singles. Housed in standard 2" x 2" metal packages (which have traditionally carried 15-20 Watt devices), these power converters supply up to 9 Amps @ 3.3V or
8 Amps at 5V. They exemplify Murata Power Solutions' relentless drive to bring designers
more power/current, in standard packages/pinouts, without compromising reliability or
resorting to thermal specmanship. Input voltage ranges are 10-18V (“D12” models), 1836V (“D24” models) or 36-75V (“D48”) models.
Employing an advanced, fully synchronous, high-frequency (300-360kHz) forward topology, UWR 26-40W singles attain 88-90% efficiencies enabling full-power operation to
ambient temperatures as high as +55°C without supplemental air flow. Assembled using
fully automated, SMT-on-pcb techniques, these DC/DC’s additionally provide low noise
(75mVp-p), high accuracy (±1%), tight line/load regulation (±0.5%), quick step response
(200µsec), and stable no-load operation.
All models feature input pi filters, input undervoltage and overvoltage shutdown,
output overvoltage protection, current limiting, short-circuit protection, and thermal shutdown. Each model has a VOUT trim pin as well as an on/off control function that may be
ordered with either positive or negative logic. These devices are fully isolated (1500Vdc)
and satisfy UL/EN/IEC60950-1 safety requirements. “D48” models (36-75V inputs) are CE
marked.
FIGURE 1. SIMPLIFIED SCHEMATIC
+OUTPUT
(6)
+INPUT
(1)
SWITCH
CONTROL
–OUTPUT
(7)
THERMAL
SHUTDOWN
–INPUT
(2)
PWM
CONTROLLER
ON/OFF
CONTROL
(4)
UVLO & OVLO
COMPARATORS
OPTO
ISOLATION
REFERENCE &
ERROR AMP
VOUT
TRIM
(8)
Typical topology is shown.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_UWR26-40W.D01 Page 1 of 10
UWR 26-40W Series
Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters
Performance Specifications and Ordering Guide ➀
Input
Output
Model ➄
VOUT
(Volts)
IOUT
(Amps)
R/N (mVp-p) ➁
Typ.
Regulation (Max.)
Max.
Line
Load ➂
VIN Nom.
(Volts)
Range
(Volts)
IIN ➃
(mA/A)
Typ.
Package
(Case,
Pinout)
Efficiency
Min.
UWR-3.3/8-D12A-C
3.3
8
75
110
±0.05%
±0.5%
12
10-18
145/2.97
88%
89%
C4, P6
UWR-3.3/9-D24A-C
3.3
9
75
110
±0.5%
±0.5%
24
18-36
50/1.4
86%
88.5%
C4, P6
UWR-3.3/9-D48AN-C
3.3
9
75
110
±0.5%
±0.5%
48
36-75
25/0.7
86%
88.5%
C4, P6
UWR-5/7-D12A-C
5
7
75
110
±0.5%
±0.5%
12
10-18
160/3.26
85.5%
89.5%
C4, P6
UWR-5/8-D24A-C
5
8
75
110
±0.05%
±0.15%
24
18-36
90/1.82
90%
91.5%
C4, P6
UWR-5/8-D48AN-C
5
8
75
110
±0.5%
±0.5%
48
36-75
25/0.93
86%
90%
C4, P6
As of September 2014, ONLY the following part numbers will be available: UWR-3.3/8-D12A-C; UWR-5/8-D24A-C
➀ Typical at TA = +25°C under nominal line voltage and full-load conditions, unless noted.
➁ Ripple/Noise (R/N) is tested/speciifed over a 20MHz bandwidth. All models are specified with an external 0.47µF
multi-layer ceramic capacitor installed across their output pins. Using a 10µF multi-layer ceramic capacitor instead
(e.g. TDK part no. C3225X5R1C106M) will further reduce the R/N to 35mVp-p typical and 75mVp-p maximum.
➂ Load regulation is specified over 0-100% load conditions. All models are stable and regulate within spec under
no-load conditions, with perhaps a slight increase in output ripple/noise.
➃ Nominal line voltage, no-load/full-load conditions.
➄ Please refer to the part number structure when ordering.
P A R T
N U M B E R
M E C H A N I C A L
S T R U C T U R E
U WR - 3.3 / 9 - D48 A N - C
Output Configuration:
U = Unipolar
RoHS-6 hazardous
substance compliant
Wide Range Input
S P E C I F I C A T I O N S
2.00
(50.8)
0.45
(11.4)
METAL CASE
Case C4
On/Off Logic, see below
Nominal Output Voltage:
3.3 or 5 Volts
INSULATED BASE
0.20 MIN
(5.1)
A-Series
High Reliability
Maximum Output Current
in Amps
Input Voltage Range:
D12 = 10-18 Volts (12V nominal)
D24 = 18-36 Volts (24V nominal)
D48 = 36-75 Volts (48V nominal)
0.040 ± 0.002 DIA.
(1.02 ± 0.05)
1.800
(45.72)
0.10
(2.5)
5
0.200
(5.08)
6
1
2
Part Number Suffixes
UWR 26-40W DC/DC's are designed so the On/Off Control function on pin 4 can be ordered with
either positive (open or "high" = on) or negative (open = off, pull low = on) logic. The standard part
number with no suffix denotes positive logic. Add an "N" suffix to select negative logic.
No Suffix
7
0.400
(10.16)
On/Off Control function (positive logic) on pin 4. Standard for D12, D24.
1.200
(30.48)
3 EQ. SP. @
0.400 (10.16)
2.00
(50.8)
4
8
0.100
(2.54)
0.40
(10.2)
BOTTOM VIEW
"N" Suffix On/Off Control function (negative logic) on pin 4. Standard for D48.
I/O Connections
Pin
Function P6
1
+Vin
2
–Vin
3
No Pin
4
On/Off Control
5
No Pin
6
+Vout
7
–Vout
8
Trim
Dimensions are in inches (mm shown for ref. only).
Note
Third Angle Projection
For D12A and D24A models,
the case is connected to
Pin 2 (–Input).
For D48A models, the case is
connected to Pin 1 (+Input).
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
Components are shown for reference only.
www.murata-ps.com/support
MDC_UWR26-40W.D01 Page 2 of 10
UWR 26-40W Series
Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted. ➀➁
Dynamic Characteristics
Input
Input Voltage Range:
D12 Models
D24 Models
D48 Models
10-18 Volts (12V nominal)
18-36 Volts (24V nominal)
36-75 Volts (48V nominal)
Overvoltage Shutdown:
D12 Models
D24 Models
D48 Models
19-23 Volts (21V typical)
37-43 Volts (40V typical)
76.5-82 Volts (78V typical)
Start-Up Threshold: ➂
D12 Models
D24 Models
D48 Models
8.5-10 Volts (9V typical)
16-18 Volts (17V typical)
33.5-36 Volts (35V typical)
Undervoltage Shutdown: ➂
D12 Models
D24 Models
D48 Models
7.5-9 Volts (8V typical)
15-17 Volts (16V typical)
31-33.5 Volts (32V typical)
Input Current:
Normal Operating Conditions
Standby Mode (Off, OV, UV)
See Ordering Guide
5mA
Input Reflected Ripple Current
250mAp-p
Dynamic Load Response:
(50-100% load step to 1% VOUT)
200µsec maximum
Start-Up Time:
VIN to VOUT
On/Off to VOUT
10ms
10ms
Switching Frequency:
UWR-3.3/8-D12A
UWR-3.3/9-D24A, -D48A
UWR-5/7-D12A
UWR-5/8-D24A, -D48A
360kHz (±36kHz)
300kHz (±30kHz)
360kHz (±36kHz)
310kHz (±30kHz)
Environmental
MTBF ➅
UWR-5/8-D24A
Bellcore, ground fixed, full power
25°C ambient
1.6 million hours
Operating Temperature ➁
-40 to +85°C, with derating
Thermal Shutdown
+110°C case
Storage Temperature
–40 to +120°C
Flammability
UL94V-0
Physical
Input Filter Type
D12 Models
D24 Models
D48 Models
Capacitive (13.2µF)
Pi (0.01µF-1µH-6.6µF)
Pi (0.01µF-2.2µH-2µF)
Reverse-Polarity Protection
Brief duration, 5A maximum
On/Off Control: ➃ ➄
On = open or 13V - +VIN, IIN = 1.6mA max.
Off = 0-0.8V, IIN = 2.6mA max.
On = 0-0.8V, IIN = 1mA max.
Off = open or 3.3-+VIN, IIN = 1mA max.
"N" Models
Output
VOUT Accuracy (50% load):
Dimensions
See mechanical specifications
Case Material
Corrosion resistant steel with
non-conductive, epoxy-based, black
enamel finish and plastic baseplate
Pin Material
RoHS: Gold plate over copper alloy
Non-RoHS: Pure tin over copper alloy
Weight:
2.7 ounces (76.5 grams)
Primary to Secondary Insulation Level Functional (D12, D24 models)
Basic (D48 models)
±1.0%, maximum
Minimum Loading for Specification: ➁ 10% of IOUT maximum
Minimum Loading for Stability: ➆
No load
Ripple/Noise (20MHz BW) ➀ ➅
See Ordering Guide
Line/Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
Trim Range ➁
±5%
Isolation Voltage:
Input-to-Output
Output to Case
1500Vdc minimum
1500Vdc minimum
Isolation Capacitance
470pF
Isolation Resistance
100MΩ
Current Limit Inception (@98%VOUT):
3.3VOUT Models
5VOUT Models
10.5-11.5 Amps
8.5-9.5 Amps
Short Circuit Current: (Average)
3.3VOUT Models
5VOUT Models
3 Amps maximum
4 Amps maximum
Overvoltage Protection:
3.3VOUT Models
5VOUT Models
Output voltage comparator
3.7-4.1 Volts
5.6-7.1 Volts
Temperature Coefficient
±0.02% per °C.
➀ All models are specified with external 0.47µF ceramic output capacitor.
➁ See Technical Notes/Graphs for details.
➂ Applying a voltage to On/Off Control (pin 4) when no input power is applied to the converter
can cause permanent damage.
➃ Output noise may be further reduced with the addition of additional external output
capacitors. See Technical Notes. Use only as much output filtering as needed and no more.
Larger caps (especially low-ESR ceramic types) may slow transient response or degrade
dynamic performance.
➄ The On/Off Control is designed to be driven with open-collector logic or the application
of appropriate voltage levels. Voltages may be referenced to the –Input (pin 2).
➅ Demonstrated MTBF available on request.
www.murata-ps.com/support
MDC_UWR26-40W.D01 Page 3 of 10
UWR 26-40W Series
Single Output, High-Density, 3.3VOUT and 5 VOUT, 26-40 Watt, DC/DC Converters
Absolute Maximum Ratings
Input Voltage:
Continuous:
D12A Models
D24A Models
D48A Models
Transient (100msec):
D12A Models
D24A Models
D48A Models
On/Off Control (pin 4) Max. Voltages
Referenced to –Input (pin 2)
No Suffix
"N" Suffix
18 Volts
36 Volts
75 Volts
25 Volts
50 Volts
100 Volts
+VIN
+VIN
Input Reverse-Polarity Protection
Current must be