0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NMG1212SC

NMG1212SC

  • 厂商:

    MURATA

  • 封装:

  • 描述:

    NMG1212SC - Isolated 2W Single Output DC/DC Converters - Murata Manufacturing Co., Ltd.

  • 数据手册
  • 价格&库存
NMG1212SC 数据手册
NMG Series Isolated 2W Single Output DC/DC Converters SELECTION GUIDE Load Regulation (Typ) Load Regulation (Max) Efficiency (Min.) Input Current at Rated Load Efficiency (Typ.) Output Current Ripple & Noise (Typ)1 Ripple & Noise (Max)1 Nominal Input Voltage Isolation Capacitance pF 33 40 40 40 40 61 74 68 Output Voltage Order Code V NMG0505SC NMG0509SC NMG0512SC NMG0515SC NMG1205SC NMG1209SC NMG1212SC NMG1215SC 5 5 5 5 12 12 12 12 V 5 9 12 15 5 9 12 15 mA 400 222 167 133 400 222 167 133 mA 470 455 450 450 200 190 190 185 5.7 4.2 3.8 3.4 4.2 2.6 2.4 2.0 % 7.3 5.9 5.1 4.5 4.9 3.1 2.9 2.4 mVp-p 28 20 18 16 22 16 13 12 35 25 25 25 35 25 25 25 % 81 84 85 85 81 83 85 85 % 83 86.5 87.5 87.5 83.5 87 88 88 kHrs 3956 3682 3299 2833 2519 2405 2235 2011 FEATURES RoHS compliant Efficiency from 81% Wide temperature performance at full 2 Watt load, –40°C to 85°C UL 94V-0 package material Industry standard pinout 1kVDC isolation 5V & 12V input 5V, 9V, 12V, & 15V output Internal SMD construction Fully encapsulated with toroidal magnetics No external components required MTTF up to 3.9 million hours Pin compatible with NMR series No electrolytic or tantalum capacitors When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the additional external capacitance for reliable start up. INPUT CHARACTERISTICS Parameter Voltage range Reflected ripple current Conditions Continuous operation, 5V input types Continuous operation, 12V input types Min. 4.5 10.8 Typ. 5 12 7.5 Max. 5.5 13.2 15 Units V mA p-p ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds Internal power dissipation Input voltage VIN, NMG05 types Input voltage VIN, NMG12 types 300°C 550mW 7V 15V OUTPUT CHARACTERISTICS Parameter Rated Power Voltage Set Point Accuracy Line regulation Conditions TA=-40°C to 85°C See tolerance envelope High VIN to low VIN Min. Typ. Max. 2 Units W %/% 1.05 1.2 PRODUCT OVERVIEW The NMG series of DC/DC Converters is particularly suited to isolating and/or converting DC power rails. The galvanic isolation allows the device to be configured to provide an isolated negative rail in systems where only positive rails exist. The wide temperature range guarantees startup from –40°C and full 2 watt output at 85°C. Pin compatibility with the NMR series ensures ease of upgradeability. ISOLATION CHARACTERISTICS Parameter Isolation test voltage Resistance Conditions Flash tested for 1 second Viso= 1000VDC Min. 1000 10 Typ. Max. Units VDC GΩ GENERAL CHARACTERISTICS Parameter Switching frequency Conditions Min. Typ. 60 Max. Units kHz TEMPERATURE CHARACTERISTICS Parameter Specification Storage Case Temperature above ambient Conditions All output types NMG0505 NMG1205 All other output types Free air convection Min. -40 -50 Typ. Max. 85 125 30 25 20 Units °C   Cooling For full details go to www.murata-ps.com/rohs 1. See Ripple & Noise characterisation method. 2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NMGC.A03 Page 1 of 4 MTTF2 NMG Series Isolated 2W Single Output DC/DC Converters TEMPERATURE DERATING GRAPH 3 TOLERANCE ENVELOPE 5% Output Voltage Output Power (W) 2 1 0 -40 85°C Typic a 2% l Loa d Lin e VNOM 0% Safe Operating Area 100 50 0 Ambient Temperature (°C) 150 10 25 50 75 -4% 100 Output Load Current (%) TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NMG series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 minute. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NMG series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NMG series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin termination finish is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. This series are backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs www.murata-ps.com Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NMGC.A03 Page 2 of 4 NMG Series Isolated 2W Single Output DC/DC Converters RIPPLE & NOISE CHARACTERISATION METHOD All measurement to be taken with the following components connected to the UUT as detailed below. 50 Ohm coax cable, solder connections one end, BNC plug at the other end. C1 C2 C3 R1 R2 T1 – 1μF X7R multilayer ceramic capacitor rated at minimum 3 x the output voltage of the UUT – 10μF tantalum capacitor rated at minimum 1.5 x the output voltage of the UUT with ESR of less than 100 milliohms at 100 kHz e.g. AVX TPS series. – 100nF multilayer ceramic capacitor, general purpose – 450 Ohm resistor, carbon film, ±1% – 50 Ohm BNC termination – 3T of the coax cable through a ferrite toroid eg Ferroxcube TN32/19/13-3E25 RLOAD – Resistive load at the UUT maximum rating. Connections via twisted wires. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input R1 T1 R2 Y INPUT + Output - - R LOAD EFFICIENCY VS LOAD NMG 5V Input Voltage 90 80 70 60 Efficiency (%) 50 40 30 20 10 0 0 10 20 30 40 50 Load (%) 60 70 80 90 100 15V 12V 9V 5V NMG 12V Input Voltage 90 80 70 60 15V 12V 9V 5V Efficiency (%) 50 40 30 20 10 0 0 10 20 30 40 50 Load (%) 60 70 80 90 100 www.murata-ps.com Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NMGC.A03 Page 3 of 4 NMG Series Isolated 2W Single Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS - 4 PIN SIP 0.77 (19.50) Pin 1 2 4 6 Function +VIN -VIN -VOUT +VOUT 0.295 (7.50) TUBE OUTLINE DIMENSIONS 0.394 (10.00) 1 0.181 (4.60) 0.141 (3.60) 0.079 (2.00) NMG0505SC XYYWWi 0.022 (0.55) 0.0178 (0.45) 2 4 6 0.1 (2.54) 0.22 (0.55) 0.0178 (0.45) 0.0118 (0.30) 0.0079 (0.20) 0.05 (1.25) 0.5 (12.70) Unless otherwise stated all dimensions in inches (mm) ±0.5mm. Tube length : 20.47 (520mm ±2mm). All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position. Weight: 2.8g Tube Quantity : 25 RECOMMENDED FOOTPRINT DETAILS 0.045 (1.15) Ø 0.039 (1.00) 4 HOLES 0.00394 (0.1) 0.1 (2.54) 0.1 (2.54) Unless otherwise stated all dimensions in inches (mm) ±0.5mm. USA: UK: France: Japan: Tucson (Az), Tel: (800) 547 2537, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Canada: Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com China: www.murata-ps.com Technical enquiries email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NMGC.A03 Page 4 of 4
NMG1212SC 价格&库存

很抱歉,暂时无法提供与“NMG1212SC”相匹配的价格&库存,您可以联系我们找货

免费人工找货