UEI25-050-D48

UEI25-050-D48

  • 厂商:

    MURATA

  • 封装:

  • 描述:

    UEI25-050-D48 - Single Output Isolated 25-Watt DC/DC Converters - Murata Manufacturing Co., Ltd.

  • 数据手册
  • 价格&库存
UEI25-050-D48 数据手册
www.murata-ps.com UEI25 Series Single Output Isolated 25-Watt DC/DC Converters Output (V) Current (A) Nominal Input (V) Typical unit 3.3 5 12 7.5 5 2.1 48 48 48 FEATURES „ Cost effective small footprint DC/DC converter, ideal for high current applications „ Industry standard 0.96" x 1.1" x 0.32" open frame package and pinout „ Input voltage range of 36-75 Vdc „ 3.3V, 5V, or 12Vdc fixed output voltages „ Isolation up to 2250 VDC (basic) „ Up to 25 Watts total output power with extensive self-protection shutdown features „ High efficiency synchronous rectifier forward topology up to 91% „ Stable operation with no required external components „ Usable -40 to 85°C temperature range (with derating) „ Certified to UL 60950-1, CAN/CSA-C22.2 No. 60950-1, IEC60950-1, EN60950-1 safety approvals, 2nd edition PRODUCT OVERVIEW Featuring a full 25 Watt output in one square inch of board area, the UEI25 series isolated DC/DC converter family offers efficient regulated DC power for printed circuit board mounting. The 0.96" x 1.1" x 0.32" (24.4 x 27.9 x 8.1 mm) converter accepts a 2:1 input voltage range of 36 to 75 Volts DC, ideal for telecom equipment. The industry-standard pinout fits larger 1" x 2" converters. The fixed output voltage is tightly regulated. Applications include small instruments, area-limited microcontrollers, data communications equipment, remote sensor systems, telephone equipment, vehicle and portable electronics. The UEI25 series includes full magnetic and optical isolation with Basic protection up to 2250 Volts DC. For powering digital systems, the outputs offer fast settling to step transients and will accept higher capacitive loads. Excellent ripple and noise specifications assure compatibility to noise-susceptible circuits. For systems requiring controlled startup/shutdown, an external remote On/Off control may use a switch, transistor or digital logic. A wealth of self-protection features avoid both converter and external circuit faults. These include input undervoltage lockout and overtemperature shutdown. The outputs current limit using the “hiccup” autorestart technique and the outputs are short-circuit protected. Additional features include output overvoltage and reverse conduction elimination. The high efficiency offers minimal heat buildup and “no fan” operation. F1 + Vin (1) B arrier +Vout (3) External DC Power Source On/Off Control (6) Controller and Power Open = On Reference and Error Amplifier Trim (4) p olarity) -Vin (2) - Vout (5) Figure 1. Connection Diagram Typical topology is shown. Murata Power Solutions recommends an external fuse.   For full details go to www.murata-ps.com/rohs www.murata-ps.com MDC_UEI25W.B03 Page 1 of 23 UEI25 Series Single Output Isolated 25-Watt DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ ➂ Output R/N (mVp-p) Root Models ➀ UEI25-033-D48 ➃ UEI25-050-D48 UEI25-120-D48 Input Regulation (Max.) IIN, min. VIN Nom. Range load (V) (V) (mA) 48 48 48 36-75 36-75 36-75 75 30 20 VOUT (V) 3.3 5 12 IOUT Total (A, Power max) (W) Typ. ➁ Max. 7.5 5 2.1 25 25 25.2 50 50 95 80 80 120 Line ±0.1% ±0.1% ±0.1% Load ±0.2% ±0.2% ±0.1% IIN, full load (A) 0.58 0.57 0.6 Efficiency Package, C75 Min. 89.0% Typ. 91% Case (inches) 0.96x1.1x0.32 0.96x1.1x0.32 0.96x1.1x0.32 Case (mm) 24.4x27.9x8.1 24.4x27.9x8.1 24.4x27.9x8.1 Pinout P85 P85 P85 87.0% 89.5% 86.0% 87.5% Notes: ➀ Please refer to the part number structure for additional options and complete ordering part numbers. ➁ Ripple and Noise is shown at 20 MHz bandwidth. ➂ All specifications are at nominal line voltage and full load, +25 °C. unless otherwise noted. See detailed specifications for full conditions. Output capacitors are 1 μF ceramic in parallel with 10 μF electrolytic. The input cap is 4.7 μF ceramic, low ESR. I/O caps are necessary for our test equipment and may not be needed for your application. ➃ Minimum load is 10% for rated specifications. PART NUMBER STRUCTURE UEI25 - 033 - D48 P M Lx - C Unipolar Output Isolated 25-Watt Series Nominal Output Voltage in Tenths of a Volt RoHS-6 Hazardous Substance Compliance (Does not claim EU RoHS exemption 7b, lead in solder) Pin Length Option (through-hole only) Blank = Std. pin length 0.25˝ (6.3mm) L1 = 0.110˝ (2.79mm)* L2 = 0.145˝ (3.68mm)* Note: Some model number combinations may not be available. Contact Murata Power Solutions. Input Voltage Range D48 = 36-75 Vdc Surface Mount Option Blank = Through-hole mount M = Surface mount (MSL rating 2) On/Off Control Polarity: P = Positive N = Negative *Alternate pin lengths may require quantity order. www.murata-ps.com MDC_UEI25W.B03 Page 2 of 23 UEI25 Series Single Output Isolated 25-Watt DC/DC Converters FUNCTIONAL SPECIFICATIONS – MODEL UEI25-033-D48 ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Input Voltage, Transient Conditions ➀ Full power operation Operating or non-operating, 100 mS max. duration Input to output tested 100 mS None, install external fuse Power on or off, referred to -Vin Minimum 0 0 Typical/Nominal Maximum 80 100 Units Vdc Vdc Isolation Voltage 2250 Vdc Input Reverse Polarity None Vdc On/Off Remote Control 0 15 Vdc Output Power 0 25.25 W Output Current Current-limited, no damage, short-circuit protected 0 7.5 A Storage Temperature Range Vin = Zero (no power) -55 125 ˚C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended. INPUT Operating voltage range Recommended External Fuse Start-up threshold Undervoltage shutdown Overvoltage shutdown Reverse Polarity Protection Internal Filter Type Input current Full Load Conditions Low Line Inrush Transient Output in Short Circuit No Load Standby Mode (Off, UV, OT) Reflected (back) ripple current ➁ Pre-biased startup 36 Fast blow Rising input voltage Falling input voltage None, install external fuse 34 32 48 35.2 34.0 None None LC 0.58 0.79 0.05 50 75 1 30 Monotonic 87 86.5 2250 basic 10 1000 Certified to UL-60950-1, CSA-C22.2 No.60950-1, IEC/EN60950-1, 2nd edition Per MIL-HDBK-217F, ground benign, Tambient=+30˚C Per Telcordia SR332, issue 1, class 3, ground fixed, Tambient=+40°C 300 Power On to Vout regulated Remote ON to Vout regulated 50-75-50% load step, settling time to within ±2% of Vout same as above Yes TBD 2 330 360 50 50 250 2 ±100 Hours x 106 Hours x 106 KHz mS mS μSec A/μSec mV Mohm pF 89.5 87.5 75 1.5 36 35.2 Vdc A Vdc Vdc Vdc Vdc Vin = nominal Vin = minimum 0.60 0.81 100 100 2 Iout = minimum, unit=ON Measured at input with specified filter External output voltage < Vset Vin=48V, full load Vin=36V, full load Input to output, continuous A A A2-Sec. mA mA mA mA, RMS GENERAL and SAFETY Efficiency Isolation Isolation Voltage Insulation Safety Rating Isolation Resistance Isolation Capacitance Safety Calculated MTBF Calculated MTBF % % Vdc DYNAMIC CHARACTERISTICS Fixed Switching Frequency Startup Time Startup Time Dynamic Load Response Dynamic load di/dt Dynamic Load Peak Deviation 180 ±30 FEATURES and OPTIONS Remote On/Off Control ➃ "N" suffix Negative Logic, ON state Negative Logic, OFF state Control Current "P" suffix Positive Logic, ON state Positive Logic, OFF state Control Current ON = Ground pin or external voltage OFF = Pin open or external voltage -0.7 10 1 ON = Pin open or external voltage OFF = Ground pin or external voltage 10 -0.7 1 15 1.2 1.2 15 V V mA V V mA www.murata-ps.com MDC_UEI25W.B03 Page 3 of 23 UEI25 Series Single Output Isolated 25-Watt DC/DC Converters FUNCTIONAL SPECIFICATIONS (CONT.) – MODEL UEI25-033-D48 OUTPUT Total Output Power Voltage Nominal Output Voltage Setting Accuracy Output Voltage Range Overvoltage Protection Current Output Current Range Minimum Load ➂ Current Limit Inception Short Circuit Short Circuit Current Short Circuit Duration (remove short for recovery) Short circuit protection method Regulation ➄ Line Regulation Load Regulation Ripple and Noise Temperature Coefficient Maximum Capacitive Loading (10% ceramic, 90% Oscon) Conditions ➀ ➂ See Derating No trim At 50% load User-adjustable Via magnetic feedback Minimum 0.0 3.267 -1 -10 4.2 0.7575 Typical/Nominal 25.0 3.30 Maximum 25.25 3.333 +1 +10 5.7 7.575 11 0.3 Units W Vdc % of Vset. % of Vnom. Vdc A % of Iout A A 5 7.575 10% minimum load 10 98% of Vnom., after warmup Hiccup technique, autorecovery Output shorted to ground, no damage Current limiting Vin=min. to max., Vout=nom., 50% load Iout=min. to max., Vin=48V 5 Hz- 20 MHz BW At all outputs Cap. ESR=
UEI25-050-D48 价格&库存

很抱歉,暂时无法提供与“UEI25-050-D48”相匹配的价格&库存,您可以联系我们找货

免费人工找货