Conductive Polymer Tantalum
Solid Capacitors
Surface Mount Type
TQS series B size
B1S size is not a recommended product.
Not recommended for new design.
Features
● High voltage(35 V max.)
● RoHS compliance, Halogen free
Specifications
Size code
Category temp. range
Rated volt. range
Category volt. range
Rated cap. range
Capacitance tolerance
Leakage current
B1S
–55 ℃ to +105 ℃
16 V to 35 V
16 V to 35 V
6.8 μF to 33 μF
±20 % (120 Hz / +20 ℃)
Please see the attached characteristics list
Dissipation factor(tan δ)
Please see the attached characteristics list
Surge voltage (V)
Rated voltage × 1.15
+105 ℃ 1000 h rated voltage applied
Capacitance change
Within ±20 % of the initial value
Endurance
Dissipation factor(tan δ) ≦ 1.5 times of the initial limit
Leakage current
Within the initial limit
+60 ℃, 90 % to 95 % RH, 500 h, No-applied voltage
Damp heat
Capacitance change
Within +40 %, −20 % of the initial value
Dissipation factor(tan δ) ≦ 1.5 times of the initial limit
(Steady State)
Leakage current
≦ 3 times of the initial limit
Marking
Dimensions (not to scale)
L
Rated voltage code
W
Polarity marking (+)
R.voltage code
C
16
R.capacitance code
W6
6.8
E
A7
25
H
Lot. No.
Rated capacitance code
Unit:V
V
10
N7
S
35
Size code
B1S
Unit:μF
33
W1
S
Unit:mm
L±0.2 W±0.2 H±0.1 S±0.3 W1±0.1
3.5
2.8
1.1
0.8
2.2
* Externals of figure are the reference.
Characteristics list
Rated
voltage
(V)
Rated
temperature
(℃)
Case size
Cate-
CateRated
gory
gory
capacitempervoltage
tance
ature
(V)
(μF)
(℃)
16
105
16
105
25
105
25
35
105
35
Specifications
(mm)
L
W
H
Size
Ripple*1
code
ESR*2 tan δ*3
current
(mA rms)
33
3.5 2.8 1.1
105
10
105
6.8
1500
(mΩ max.)
Floor life
level
Standard
LC*4
(μA)
Part number
Min.
packaging Reflow Reflow
q'ty
(pcs)
70
0.10
52.8
16TQS33MBD
2500
3.5 2.8 1.1 B1S 1000
100
0.10
25.0
25TQS10MED
2500
3.5 2.8 1.1
150
0.10
23.8
35TQS6R8MHD
2500
900
temp
temp
≦260℃ ≦250℃
-
3
*1: Ripple current(100 kHz / +45 ℃)
*2: ESR(100 kHz / +20 ℃)
*3: tan δ (120 Hz / +20 ℃)
*4: After 5 minutes
◆ Please refer to each page in this catarog for “Reflow conditions” ,“Taping specifications” and "Floor life level" .
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01-Oct-20
Conductive Polymer Tantalum
Solid Capacitors
Surface Mount Type
TQS series D size
Features
● High voltage(35 V max.)
● RoHS compliance, Halogen free
Specifications
Size code
Category temp. range
Rated volt. range
Category volt. range
Rated cap. range
Capacitance tolerance
Leakage current
D15S
–55 ℃ to +105 ℃
35 V
35 V
47 μF
±20 % (120 Hz / +20 ℃)
Please see the attached characteristics list
Dissipation factor(tan δ)
Please see the attached characteristics list
Surge voltage (V)
Rated voltage × 1.15
+105 ℃ 2000 h rated voltage applied
Capacitance change
Within ±20 % of the initial value
Endurance
Dissipation factor(tan δ) ≦ 1.5 times of the initial limit
Leakage current
Within the initial limit
+60 ℃, 90 % to 95 % RH, 500 h, No-applied voltage
Damp heat
Capacitance change
Within +40 %, −20 % of the initial value
Dissipation factor(tan δ) ≦ 1.5 times of the initial limit
(Steady State)
Leakage current
≦ 3 times of the initial limit
Marking
Dimensions (not to scale)
L
Rated capacitance (μF)
Polarity
H
W
marking (+)
Rated voltage code
Lot. No.
R.voltage code
V
35
S2
S1
Size code
Unit:V
D15S
W1
Unit:mm
L±0.3 W±0.2 H±0.1 S1±0.2 S2±0.2 W1±0.1
7.3
4.3
1.4
1.1
1.4*1
2.4
*1: - side
Characteristics list
Rated
voltage
(V)
35
Rated
temperature
(℃)
105
Case size
Cate-
CateRated
gory
gory
capacitempervoltage
tance
ature
(V)
(μF)
(℃)
35
105
47
Specifications
(mm)
L
W
H
Size
Ripple*1
code
ESR*2 tan δ*3
current
(mA rms)
7.3 4.3 1.4 D15S 1200
(mΩ max.)
100
0.10
Floor life
level
Standard
LC*4
(μA)
164.5
Part number
Min.
packaging Reflow Reflow
q'ty
(pcs)
35TQS47MEU
4000
temp
temp
≦260℃ ≦250℃
3
3
*1: Ripple current(100 kHz / +105 ℃)
*2: ESR(100 kHz / +20 ℃)
*3: tan δ (120 Hz / +20 ℃)
*4: After 5 minutes
◆ Please refer to each page in this catarog for “Reflow conditions” ,“Taping specifications” and "Floor life level" .
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
30-Jun-20
Guidelines and precautions regarding the
technical information and use of our products
described in this online catalog.
■ If you want to use our products described in this online catalog for applications requiring
special qualities or reliability, or for applications where the failure or malfunction of the
products may directly jeopardize human life or potentially cause personal injury
(e.g. aircraft and aerospace equipment, traffic and transportation equipment, combustion
equipment, medical equipment, accident prevention, anti-crime equipment, and/or safety
equipment), it is necessary to verify whether the specifications of our products fit to such
applications. Please ensure that you will ask and check with our inquiry desk as to whether
the specifications of our products fit to such applications use before you use our products.
■ The quality and performance of our products as described in this online catalog only apply
to our products when used in isolation. Therefore, please ensure you evaluate and verify
our products under the specific circumstances in which our products are assembled in your
own products and in which our products will actually be used.
■ If you use our products in equipment that requires a high degree of reliability, regardless
of the application, it is recommended that you set up protection circuits and redundancy
circuits in order to ensure safety of your equipment.
■ The products and product specifications described in this online catalog are subject to
change for improvement without prior notice. Therefore, please be sure to request and
confirm the latest product specifications which explain the specifications of our products in
detail, before you finalize the design of your applications, purchase, or use our products.
■ The technical information in this online catalog provides examples of our products'
typical operations and application circuits. We do not guarantee the non-infringement of
third party's intellectual property rights and we do not grant any license, right, or interest
in our intellectual property.
■ If any of our products, product specifications and/or technical information in this online
catalog is to be exported or provided to non-residents, the laws and regulations of the
exporting country, especially with regard to security and export control, shall be observed.
■ The switchover date for compliance with the RoHS Directive/REACH Regulations varies
depending on the part number or series of our products.
■ When you use the inventory of our products for which it is unclear whether those products
are compliant with the RoHS Directive/REACH Regulation, please select "Sales Inquiry" in the
website inquiry form and contact us.
We do not take any responsibility for the use of our products outside the scope of the
specifications, descriptions, guidelines and precautions described in this online catalog.
01-Oct-19
Notices / Items to be observed
Notices
■ Applicable laws and regulations
・This product complies with the RoHS Directive (Restriction of the use of certain hazardous substances in
electrical and electronic equipment (DIRECTIVE 2011/65/EU and(EU)2015/863)).
・ No Ozone Depleting Chemicals(ODC's), controlled under the Montreal Protocol Agreement, are used in
producing this product.
We do not use PBBs or PBDEs as brominated flame retardants.
・ Export procedure which followed export related regulations, such as foreign exchange and a foreign trade
method, on the occasion of export of this product.
・ These products are not dangerous goods on the transportation as identified by UN(United Nations) numbers
or UN classification.
■ Limited applications
・ This capacitor is designed to be used for electronics circuits such as audio/visual equipment, home
appliances, computers and other office equipment, optical equipment, measuring equipment.
・ Prior to usage of this capacitor for applications requiring high reliability and safety and malfunction of capacitor might
threaten human life or property, it is highly recommended to confirm the usage of this capacitors with Panasonic.
■ Intellectual property rights and licenses
・ The technical information in this specification provides examples of our products' typical operations and application
circuits. We do not guarantee the non-infringement of third party's intellectual property rights and we do not grant
any license, right, or interest in our intellectual property.
Items to be observed
■ For specification
・ This specification guarantees the quality and performance of the product as individual components.
The durability differs depending on the environment and the conditions of usage.
Before use, check and evaluate their compatibility with actual conditions when installed in the products.
When safety requirements cannot be satisfied in your technical examination, inform us immediately.
・ Do not use the products beyond the specifications described in this document.
■ Upon application to products where safety is regarded as important
Install the following systems for a failsafe design to ensure safety if these products are to be used in
equipment where a defect in these products may cause the loss of human life or other signification damage,
such as damage to vehicles (automobile, train, vessel), traffic lights, medical equipment, aerospace equipment,
electric heating appliances, combustion/ gas equipment, rotating rotating equipment, and disaster/crime
prevention equipment.
(1) The system is equipped with a protection circuit and protection device.
(2) The system is equipped with a redundant circuit or other system to prevent an unsafe status in the event
of a single fault.
■ Conditions of use
・ Before using the products, carefully check the effects on their quality and performance, and determined
whether or not they can be used. These products are designed and manufactured for general-purpose and
standard use in general electronic equipment. These products are not intended for use in the following special
conditions.
(1) In liquid, such as Water, Oil, Chemicals, or Organic solvent.
(2) In direct sunlight, outdoors, or in dust.
(3) In vapor, such as dew condensation water of resistive element, or water leakage, salty air, or air with a
high concentration corrosive gas, such as Cl2, H2S, NH3, SO2, or NOx.
(4) In an environment where strong static electricity or electromagnetic waves exist.
(5) Mounting or placing heat-generating components or inflammables, such as vinyl-coated wires, near
these products.
(6) Sealing or coating of these products or a printed circuit board on which these products are mounted,
with resin and other material.
(7) Using resolvent, water or water-soluble cleaner for flux cleaning agent after soldering. (In particular,
when using water or a water-soluble cleaning agent, be careful not to leave water residues)
(8) Using in the atmosphere where strays acid or alkaline.
(9) Using in the atmosphere where there are excessive vibration and shock.
(10) Using in the atmosphere where there are low pressure or decompression.
・ Please arrange circuit design for preventing impulse or transitional voltage.
Do not apply voltage, which exceeds the full rated voltage when the capacitors receive impulse voltage,
instantaneous high voltage, high pulse voltage etc.
・ Our products there is a product are using an electrolyte solution. Therefore, misuse can result in rapid
deterioration of characteristics and functions of each product. Electrolyte leakage damages printed circuit and
affects performance, characteristics, and functions of customer system.
01-Oct-19
Conductive Polymer Tantalum Solid Capacitors
Guidelines and precautions(POSCAP)
1. Circuit design
1.1 Prohibited circuits
Since problems can be expected, POSCAP cannot be used on the following circuits.
(1) High impedance voltage retention circuits
(2) Coupling circuit
(3) Time constant circuits
(4) Circuits greatly affected by leakage current
(5) The circuit in which two or more POSCAP are connected in a series so as to raise the endurance voltage.
1.2 Failure and life-span
The failure rate is 0.5 %* / 1000 h (Confidence level : 60 %) based on JIS C 5003.
The mainly failure modes are as follows.
* B2 size or less : 1.0 %
1.2-1 Contingency failure
The main causes of failure are thermal stresses cause by the soldering or thermal use environment, along
with heat stresses, electrical stresses or mechanical stresses. The most common failure mode is a short
circuit. In case a short circuit occurs, ensure safety by fully considering the followings.
(a) If POSCAP emit smoke, turn off the main power of the equipment. In this case, keep your face and
hands away from the area.
(b) It may take a few seconds to a few minutes before POSCAP emits smoke by the situation. Increase
safety by using a protective circuit.
(c) If the smoke comes into eyes, rinse immediately. If the smoke is inhaled, gargle immediately.
(d) In case a large current continues to flow after a short circuit, in the worst case, the shorted-out
section may ignite. For safety, install a redundant circuit or a protective circuit, etc.
1.2-2 Wear-out failure (lifetime)
When lifetime exceeded the specified guarantee time of Endurance and Damp heat, electrolyte might
insulate and cause electric characteristic changed. This is called an open circuit. The rated capacitance
values and the electrical characteristics values such as ESR specified in the characteristics list are factory
default values. Please carefully design a circuit since rated capacitance values and the electrical
characteristics values may change (increase) beyond the specified values under the conditions of rated
voltage/temperature and electrical/mechanical performances.
1.3 Reduction of failure stress
When POSCAP is used within the rated voltage, it shows a stable characteristic, but it may be damaged
in a short circuit when an overvoltage, for instance, is applied. The time to reach the failure mode can be
extended by using POSCAP with reduced environment temperature, ripple current and applied voltage.
Failure rate
・ In the case of the endurance which is 105 °C 2000 h.
0.5 %/1000 h (Environment temp. : 105 °C, Rated voltage or Category voltage applied)
・ In the case of the endurance which is 105 °C 1000 h or 125 °C 1000 h.
1.0 %/1000 h (Environment temp. : 105 °C, Rated voltage or Category voltage applied)
・ In the case of the endurance which is 85 °C 1000 h.
1.0 %/1000 h (Environment temp. : 85 °C, Rated voltage applied)
1.4 Check the rated performance
After checking the operation and installation environments, design the circuit so that it falls within the rated
performance range stipulated in this delivery specification.
1.5 Operating temperature and ripple current
(1) Set the operating temperature so that it falls within the range stipulated in this delivery specification.
(2) Do not apply current that exceeds the allowable ripple current. Ripple current should be controlled so that
surface temperature of a capacitor do not exceed the rated temperature.
(For questions regarding TQC series, please contact us.)
(3) The ESR values specified in the characteristics list are factory default values.
ESR values may change (increase) beyond the specified values depending on the customer's use conditions.
11-Mar-20
Conductive Polymer Tantalum Solid Capacitors
1.6 Leakage current
Even when the soldering conditions fall within the range of this delivery specifications, leakage current
increases a little on occasion. It also increases a little during high temperature storage, high humidity storage
こand temperature cycling with no voltage applied. In cases such as these, leakage current will decrease by
applying voltage under the condition of below the POSCAP's maximum operating temperature.
The speed at which the leakage current is restored is increased by applying voltage when the POSCAP's
temperature is close to the maximum operating temperature.
1.7 Rapid charge and discharge limitation
Rapid charge and discharge are restricted (for maintainance of high-proof reliability).
A protective circuit is recommended for when a rapid charge or discharge causes excessive rush current
since this is main cause of short circuit and large leakage current. Use a protective circuits in case the rush
current value exceeds 20 A*.
Be sure to insert a protection resistor of about 1 kΩ for charge and discharge when measuring the leakage
current.
* When TH series use under the ambient temperature more than 105 °C : 10 A, TPU series : 10 A
2. Mounting
2.1 Protect circuit
The failure mode of POSCAP is the short mode. When it breaks down, short electric current flows to it.
POSCAP gives off heat by this short current.
Do the following consideration in design fully for the safety because it has a bad influence on the part around
POSCAP due to this heat.
・ A protective circuit and a protective device are set up, so as to make the system safer.
・ A diffuse circuit and so on is set up, so as to make the system safer such as that a machine may not
break down as to the single trouble.
2.2 Considerations when soldering
The soldering conditions are to be within the range prescribed in this delivery specification.
If the specifications are not followed, there is the possibility of degradation of electric characteristic and
lifetime when soldering is conducted under conditions that are harsher that those stipulated.
2.3 Others
POSCAP’s Electrical characteristics are affected by temperature and frequency fluctuations.
Design circuits after checking the amount of fluctuation.
3. Storage
It is necessary to set an environment to prevent a trouble at the time of soldering by the degradation of solder
ability or moisture's getting into the molding resin when POSCAP are stored.
● Please make storage of POSCAP sealing up in the reel and storage bag at the time of delivery in the following
environment. Also, set storage period of unopened as 18 months or shorter after shipment from factory.
・ Room temperature and room humidity (generally : 15 to 35 °C, 45 to 75% RH ) are desirable.
・ Place where POSCAP is not exposed by direct sunshine.
● Please unseal storage bag just before mounting and use up POSCAP in the storage bag.
Level
2a
3
5
Floor life
Time
Conditions
4 weeks
≦ 30 ℃ / 60 %RH
168 hours
≦ 30 ℃ / 60 %RH
48 hours
≦ 30 ℃ / 60 %RH
POSCAP is not compatible with JEDEC J-STD-020, J-STD-033
✽ Intellectual property right
We, Panasonic Group are providing the product and service that customers can use without anxiety, and are
working positively on the protection of our products under intellectual property rights.
Representative patents relating to POSCAP are as follows:
US Patent No.6508800, No.6891717, No.7158368, No.7326260号, No.8081421, No.8149569,
No.8456804, No.8559166
11-Mar-20