Conductive Polymer Aluminum
Solid Capacitors
Radial Lead Type
SEPC series
Features
● Super low ESR (5 mΩ max.)
● Large capacitance (2700 μF max.)
● RoHS compliance, Halogen free
Specifications
Damp heat
(Steady state)
C55
2.5
6.3
100 to 560
220
C6
C9
2.5 to 16
100 to 560
100 to 820
E7
E9
–55 ℃ to +105 ℃
E12
6.3 to 16
2.5 to 16
16
2.5 to 6.3
2.5 to 16
150 to 1000
180 to 1000
180 to 270
470 to 820
470 to 2700
Dimensions (not to scale)
・E12, E13, F13 size
ød
øD
⊕
Polarity marking (−)
15 min.
Lot No.
L
⊖
4 min.
19 min.
・B9, C55, C6, C9, E7, E9 size
ød
⊕
øD
Series code*
15 min.
* Depends on the case size.
F13
±20 % (120 Hz / +20 ℃)
Please see the attached characteristics list
Please see the attached characteristics list
+105 ℃ 5000 h, rated voltage applied
Capacitance change
Within ±20 % of the initial value
Dissipation factor (tanδ) ≦ 150 % of the initial limit
DC leakage current
Within the initial limit
+60 ℃, 90 % to 95 % RH, 1000 h, No-applied voltage
Capacitance change
Within ±20 % of the initial value
Dissipation factor (tanδ) ≦ 150 % of the initial limit
DC leakage current
Within the initial limit (after voltage processing)
Marking
R. voltage
(V)
E13
R. capacitance
(μF)
F
Endurance
B9
F
Size code
Category temp. range
Rated voltage range (V)
Nominal cap.range (μF)
Capacitance tolerance
DC leakage current
Dissipation factor (tan δ)
⊖
4 min.
19 min.
L
Flat rubber is used for B9, C55, C6, C9, E7, and E9 size.
Size code
B9
C55
C6
C9
E7
E9
E12
E13
F13
øD±0.5
5.0
6.3
6.3
6.3
8.0
8.0
8.0
8.0
10.0
L max.
9.0
5.5
6.0
9.0
7.0
9.0
12.0
13.0
13.0
F±0.5
2.0
2.5
2.5
2.5
3.5
3.5
3.5
3.5
5.0
Unit:mm
ød±0.05
0.6
0.45
0.5*1
0.6
0.6*2
0.6
0.6
0.6
0.6
*1: 16SEPC100M : 0.45±0.05
*2: 16SEPC150MD、10SEPC270M : 0.45±0.05
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
05-Mar-21
SEPC series
Characteristics list
Case size
Rated
voltage
(V)
(±20 %)
(μF)
100
330
390
470
560
2.5
820
1000
2700
560
4.0
680
820
220
470
6.3
10
560
680
1000
1500
270
100
150
16
180
220
270
470
Specifications
(mm)
Rated
capacitance
øD
L
Size
code
Ripple
current *1
(mA rms)
5.0
5.0
6.3
5.0
5.0
6.3
6.3
8.0
6.3
8.0
8.0
8.0
8.0
8.0
10.0
6.3
8.0
8.0
8.0
10.0
6.3
6.3
8.0
8.0
6.3
8.0
10.0
8.0
10.0
8.0
6.3
6.3
8.0
8.0
8.0
8.0
8.0
8.0
10.0
9.0
9.0
6.0
9.0
9.0
6.0
9.0
9.0
9.0
7.0
9.0
9.0
13.0
9.0
13.0
9.0
9.0
13.0
13.0
13.0
5.5
9.0
9.0
13.0
9.0
9.0
13.0
7.0
13.0
7.0
6.0
9.0
7.0
9.0
12.0
7.0
9.0
12.0
13.0
B9
C6
B9
C6
C9
E9
C9
E7
E9
E13
E9
F13
C9
E9
E13
F13
C55
C9
E9
E13
C9
E9
F13
E7
F13
E7
C6
C9
E7
E9
E12
E7
E9
E12
F13
ESR*2
(mΩ max.)
4180
4180
3900
4180
4180
3900
5600
4700
5600
5300
6100
7200
6100
6100
5560
5600
6100
6100
6100
6640
2980
5600
5700
5700
5600
6100
6640
3530
5560
3220
2490
4680
3220
5000
4360
4150
5000
5000
6100
7
7
10
7
7
10
7
8
7
8
7
5
7
7
10
7
7
7
7
7
18
7
8
8
7
7
7
18
10
22
24
10
22
10
16
13
10
11
10
tan δ*3
0.10
0.10
0.12
0.10
0.10
0.12
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.12
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.12
0.10
0.10
0.12
0.10
0.10
0.10
0.10
0.10
0.10
Part number
LC*4
(μA)
500
500
500
500
500
500
500
280
500
500
500
500
500
500
1350
500
500
500
544
656
280
592
592
592
705
705
857
1260
1890
500
320
500
500
576
576
500
864
864
1504
Click here for part number
list of lead terminal cutting
and lead terminal taping
2SEPC100MZ
2SEPC330MZ
2SEPC390M
2SEPC470MZ
2SEPC560MZ
2SEPC560M
2SEPC560MW
2SEPC560MX
2SEPC820MW
2SEPC820MD
2SEPC820MX
2SEPC820MY
2R5SEPC820M
2SEPC1000MX
2SEPC2700M
4SEPC560MW
4SEPC560MX
4SEPC560M
4SEPC680M
4SEPC820M
6SEPC220M
6SEPC470MW
6SEPC470MX
6SEPC470M
6SEPC560MW
6SEPC560MX
6SEPC680M
6SEPC1000MD
6SEPC1500M
10SEPC270MD
16SEPC100M
16SEPC100MW
16SEPC150MD
16SEPC180MX
16SEPC180M
16SEPC220MD
16SEPC270MX
16SEPC270M
16SEPC470M
*1: Ripple current (100 kHz / +105 ℃)
*2: ESR (100 kHz to 300 kHz / +20 ℃)
*3: tan δ (120 Hz / +20 ℃)
*4: After 2 minutes
◆ Please refer to each page in this catarog for “Flow conditions” and “Taping specifications”.
Frequency correction factor for ripple current
Frequency(f)
Coefficient
120 Hz ≦ f < 1 kHz
0.05
1 kHz ≦ f < 10 kHz
0.3
10 kHz ≦ f < 100 kHz
0.7
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
100 kHz ≦ f < 500 kHz
1
05-Mar-21
SEPC series
Packing specifications
◇ Radial lead type
● Lead terminal process
1-1. Correspondence list
※ The following table is a standard specification. Please contact us separately concerming specifications except for that mentioned below.
Bag-packed products (lead terminal cutting)
Series
Size code
SEPC
B9, C55, C6, C9, E7, E9, E12
E13
F13
Not processed
No code
No code
No code
Taping products
Straight cut
+C3
+C3
+C3
+TSS(+S)
+TS
+T
1-2. Lead terminal cutting specifications
Process names
Size code
Lead terminal
cutting code
Straight
cut
B9
C55, C6, C9
E7, E9, E12, E13
F13
+C3
Lead terminal dimensions
L
Unit:mm
3.5±0.5
1-3. Taping specifications for automatic insertion
Size code
Case size
F
Taping code
B9
ø5
F=2.0 mm
C55, C6, C9
ø6.3
F=2.5 mm
E7, E9, E12
ø8
F=3.5 mm
E13
ø8
F=3.5 mm
Taping dimensions
+TSS (+S)
Carrier tape
Hold-down tape
+TS
Carrier tape
Hold-down tape
F13
ø10
F=5.0 mm
+T
Carrier tape
Hold-down tape
Code
Tolerance
ø5
+TSS (+S)
ø6.3
ø8
+TS
ø8
+T
ø10
Code
Tolerance
ø5
+TSS (+S)
ø6.3
ø8
+TS
ø8
+T
ø10
F
+0.8
-0.2
2.0
2.5
3.5
3.5
5.0
t
±0.3
0.6
0.6
0.6
0.6
0.6
P
±1.0
12.7
12.7
12.7
12.7
12.7
ℓ
max.
0
0
0
0
0
P0
±0.2
12.7
12.7
12.7
12.7
12.7
P1
P2
±0.5
±1.0
5.35
5.10
4.60
4.60
3.85
6.35
6.35
6.35
6.35
6.35
Δh
±1.0
0
0
0
0
0
W
±0.5
18.0
18.0
18.0
18.0
18.0
W0
min.
9.5
9.5
9.5
9.5
9.5
W1
W2
H
±0.5
max.
±0.75
9.0
9.0
9.0
9.0
9.0
2.5
2.5
2.5
2.5
2.5
17.5
17.5
17.5
17.5
18.5
øD0
±0.2
4.0
4.0
4.0
4.0
4.0
L
max.
11.0
11.0
11.0
11.0
11.0
Unit:mm
● Minimum packing quantity and weight
Size
code
B9
C55
C6
C9
Case
size
ø5
ø6.3
ø6.3
ø6.3
Bag-packed products
Taping products
Quantity(pcs./Bag)
Typical weight(g)
Quantity(pcs./Bag)
Typical weight(g)
500
500
500
500
180
150
160
240
2000
1500
1500
1500
1000
650
700
1000
Size
code
E7
E9
E12
E13
F13
Case
size
ø8
ø8
ø8
ø8
ø10
Bag-packed products
Taping products
Quantity(pcs./Bag)
Typical weight(g)
Quantity(pcs./Bag)
Typical weight(g)
200
200
200
200
200
110
130
200
160
280
1000
1000
1000
1000
500
820
900
980
1060
940
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
05-Mar-21
SEPC series
Radial lead (Lead terminal cutting / Lead terminal taping)
Series
No processing
SEPC
10SEPC270MD
16SEPC100M
16SEPC100MW
16SEPC150MD
16SEPC180M
16SEPC180MX
16SEPC220MD
16SEPC270M
16SEPC270MX
16SEPC470M
2R5SEPC820M
2SEPC1000MX
2SEPC100MZ
2SEPC2700M
2SEPC330MZ
2SEPC390M
2SEPC470MZ
2SEPC560M
2SEPC560MW
2SEPC560MX
2SEPC560MZ
2SEPC820MD
2SEPC820MW
2SEPC820MX
2SEPC820MY
4SEPC560M
4SEPC560MW
4SEPC560MX
4SEPC680M
4SEPC820M
6SEPC1000MD
6SEPC1500M
6SEPC220M
6SEPC470M
6SEPC470MW
6SEPC470MX
6SEPC560MW
6SEPC560MX
6SEPC680M
Lead terminal cutting
Lead terminal taping
10SEPC270MD+C3
16SEPC100M+C3
16SEPC100MW+C3
16SEPC150MD+C3
16SEPC180M+C3
16SEPC180MX+C3
16SEPC220MD+C3
16SEPC270M+C3
16SEPC270MX+C3
16SEPC470M+C3
2R5SEPC820M+C3
2SEPC1000MX+C3
2SEPC100MZ+C3
2SEPC2700M+C3
2SEPC330MZ+C3
2SEPC390M+C3
2SEPC470MZ+C3
2SEPC560M+C3
2SEPC560MW+C3
2SEPC560MX+C3
2SEPC560MZ+C3
2SEPC820MD+C3
2SEPC820MW+C3
2SEPC820MX+C3
2SEPC820MY+C3
4SEPC560M+C3
4SEPC560MW+C3
4SEPC560MX+C3
4SEPC680M+C3
4SEPC820M+C3
6SEPC1000MD+C3
6SEPC1500M+C3
6SEPC220M+C3
6SEPC470M+C3
6SEPC470MW+C3
6SEPC470MX+C3
6SEPC560MW+C3
6SEPC560MX+C3
6SEPC680M+C3
10SEPC270MD+S
16SEPC100M+TSS
16SEPC100MW+S
16SEPC150MD+S
16SEPC180M+TSS
16SEPC180MX+S
16SEPC220MD+S
16SEPC270M+TSS
16SEPC270MX+S
16SEPC470M+T
2R5SEPC820M+TS
2SEPC1000MX+S
2SEPC100MZ+TSS
2SEPC2700M+T
2SEPC330MZ+TSS
2SEPC390M+TSS
2SEPC470MZ+TSS
2SEPC560M+TSS
2SEPC560MW+TSS
2SEPC560MX+TSS
2SEPC560MZ+TSS
2SEPC820MD+TSS
2SEPC820MW+TSS
2SEPC820MX+TSS
2SEPC820MY+TSS
4SEPC560M+TS
4SEPC560MW+TSS
4SEPC560MX+TSS
4SEPC680M+TS
4SEPC820M+T
6SEPC1000MD+S
6SEPC1500M+T
6SEPC220M+TSS
6SEPC470M+TS
6SEPC470MW+TSS
6SEPC470MX+TSS
6SEPC560MW+TSS
6SEPC560MX+TSS
6SEPC680M+T
29-Jul-20
Guidelines and precautions regarding the
technical information and use of our products
described in this online catalog.
■ If you want to use our products described in this online catalog for applications requiring special
qualities or reliability, or for applications where the failure or malfunction of the products may directly
jeopardize human life or potentially cause personal injury (e.g. aircraft and aerospace equipment,
traffic and transportation equipment, combustion equipment, medical equipment, accident prevention,
anti-crime equipment, and/or safety equipment), it is necessary to verify whether the specifications of
our products fit to such applications. Please ensure that you will ask and check with our inquiry desk
as to whether the specifications of our products fit to such applications use before you use our products.
■ The quality and performance of our products as described in this online catalog only apply to our
products when used in isolation. Therefore, please ensure you evaluate and verify our products under
the specific circumstances in which our products are assembled in your own products and in which our
products will actually be used.
■ Please ensure the safety by means of protection circuit, redundant circuit etc. in your system design
in order to prevent the occurrence of life crisis and other serious damages due to the failure of our
products.
■ The products and product specifications described in this online catalog are subject to change for
improvement without prior notice. Therefore, please be sure to request and confirm the latest product
specifications which explain the specifications of our products in detail, before you finalize the design
of your applications, purchase, or use our products.
■ The technical information in this online catalog provides examples of our products' typical operations
and application circuits. We do not guarantee the non-infringement of third party's intellectual property
rights and we do not grant any license, right, or interest in our intellectual property.
■ If any of our products, product specifications and/or technical information in this online catalog is to
be exported or provided to non-residents, the laws and regulations of the exporting country,
especially with regard to security and export control, shall be observed.
■ The switchover date for compliance with the RoHS Directive/REACH Regulations varies depending
on the part number or series of our products.
■ When you use the inventory of our products for which it is unclear whether those products are
compliant with the RoHS Directive/REACH Regulation, please select "Sales Inquiry" in the website
inquiry form and contact us.
Please note that we do not owe any liability and responsibility if our products are used beyond
the description of this catalog or without complying with precautions in this catalog.
25-Nov-22
Notices / Items to be observed
Notices
■ Applicable laws and regulations
・This product complies with the RoHS Directive (Restriction of the use of certain hazardous substances in electrical and
electronic equipment (DIRECTIVE 2011/65/EU and(EU)2015/863)).
・ No Ozone Depleting Chemicals(ODC's), controlled under the Montreal Protocol Agreement, are used in producing
this product. We do not use PBBs or PBDEs as brominated flame retardants.
・ Export procedure which followed export related regulations, such as foreign exchange and a foreign trade method,
on the occasion of export of this product.
・ These products are not dangerous goods on the transportation as identified by UN(United Nations) numbers or UN
classification.
■ Limited applications
・ This capacitor is designed to be used for electronics circuits such as audio/visual equipment, home appliances,
computers and other office equipment, optical equipment, measuring equipment.
・ An advanced specification must be signed individually for high-reliability use that might threaten human life or
property due to a malfunction of the capacitor.
■ Intellectual property rights and licenses
・ The technical information in this specification provides examples of our products' typical operations and application
circuits. We do not guarantee the non-infringement of third party's intellectual property rights and we do not grant
any license, right, or interest in our intellectual property.
Items to be observed
■ For specification
・ This specification guarantees the quality and performance of the product as individual components.
The durability differs depending on the environment and the conditions of usage.
Before use, check and evaluate their compatibility with actual conditions when installed in the products.
When safety requirements cannot be satisfied in your technical examination, inform us immediately.
・ Do not use the products beyond the specifications described in this document.
■ Upon application to products where safety is regarded as important
Install the following systems for a fail-safe design to ensure safety if these products are to be used in equipment where
a defect in these products may cause the loss of human life or other signification damage, such as damage to vehicles
(automobile, train, vessel), traffic lights, medical equipment, aerospace equipment, electric heating appliances,
combustion/ gas equipment, rotating rotating equipment, and disaster/crime prevention equipment.
(1) The system is equipped with a protection circuit and protection device.
(2) The system is equipped with a redundant circuit or other system to prevent an unsafe status in the event
of a single fault.
■ Conditions of use
・ Before using the products, carefully check the effects on their quality and performance, and determined whether or not they
can be used. These products are designed and manufactured for general-purpose and standard use in general electronic
equipment. These products are not intended for use in the following special conditions.
(1) In liquid, such as Water, Oil, Chemicals, or Organic solvent.
(2) In direct sunlight, outdoors, or in dust.
(3) In vapor, such as dew condensation water of resistive element, or water leakage, salty air, or air with a high
concentration corrosive gas, such as Cl2, H2S, NH3, SO2, or NOx.
(4) In an environment where strong static electricity or electromagnetic waves exist.
(5) Mounting or placing heat-generating components or inflammables, such as vinyl-coated wires, near these products.
(6) Sealing or coating of these products or a printed circuit board on which these products are mounted, with resin and
other material.
(7) Using resolvent, water or water-soluble cleaner for flux cleaning agent after soldering. (In particular, when using water or
a water-soluble cleaning agent, be careful not to leave water residues)
(8) Using in the atmosphere where strays acid or alkaline.
(9) Using in the atmosphere where there are excessive vibration and shock.
(10) Using in the atmosphere where there are low pressure or decompression.
・ Please arrange circuit design for preventing impulse or transitional voltage.
Do not apply voltage, which exceeds the full rated voltage when the capacitors receive impulse voltage, instantaneous high
voltage, high pulse voltage etc.
・ Our products there is a product are using an electrolyte solution. Therefore, misuse can result in rapid deterioration of
characteristics and functions of each product. Electrolyte leakage damages printed circuit and affects performance,
characteristics, and functions of customer system.
16-Apr-21
Conductive Polymer Aluminum Solid Capacitors
Application Guidelines(OS-CON)
1. Circuit design
1.1 Prohibited circuits
(1) Leakage current of the OS-CON may increase in the following conditions.
(a) Soldering
(b) When voltage is not applied : high temperature no-load test, high temperature and high humiditynoload test,
rapidly changing temperature test, etc.
(2) Avoid the use of the OS-CON in the following type of circuits because leakage current may increase.
(a) High-impedance circuits
(b) Coupling circuits
(c) Time constant circuits
(d) Other circuits that are significantly affected by leakage current.
✽ If you plan to use 2 or more OS-CONs in a series connection, please contact us before use。
1.2 Failure and life-span
The failure rate is 0.5 % /1000 h (Confidence level : 60 %) based on JIS C 5003.
The prospective failure is not zero. The mainly failure modes are as follows.
1.2-1 Contingency failure
The most common failure mode is a short circuit. Mainly caused by the soldering or operating temperature
environment, along with heat stresses, electrical stresses or mechanical stressesas follows.
・ Applying voltage over the rated voltage.
・ Applying reverse voltage
・ Excessive mechanical stress
・ Applying rush current by sudden charge or discharge out of the specification.
(1) The following phenomenon is seen when short-current is applied to the OS-CON.
(a) When current is relatively low. (ø10 : approx 1 A or less, ø8 : approx 0.5 A or less, ø6.3 : approx 0.2 A or less)
The OS-CON becomes heated, but no effects are visible even when the current is continously carried.
(b) When the short circuit currents exceed the mentioned value above.
After internal temperature increase, sealing rubber may be turned over.
In some cases, odorous gas may be produced.
(2) In case a short circuit occurs, ensure safety by fully considering the followings.
(a) If odorous gas is released, turn off the main power of the equipment.
In this case, keep your face and hands away from the area.
(b) Though it depends on the conditions, it takes seconds to minutes before odorant gas generates.
Protective circuit should operate in this period.
(c) If the gas comes into eyes, rinse immediately. If the gas is inhaled, gargle immediately.
(d) Do not lick the electrolyte. If the electrolyte touches skin, wash it off with soap immediately.
(e) The OS-CON contains combustible substances. In case a large current continues to flow after a short circuit,
in the worst case, the shorted-out section may ignite. For safety, install a redundant circuit or a protective
circuit, etc.
1.2-2 Wear-out failure (life time)
When lifetime span exceeded the specified guarantee time of endurance and damp heat, electrolyte might insulate
and cause electric characteristic changed. This is called an open circuit.
The electric characteristics of capacitance and ESR may possibly change within the specified range in specifications
even if it is used under the condition of the rated voltage, electric and mechanical performance.
Please note it when designing.
1.3 Leakage current
Mechanical stress may cause OS-CON’s leakage current increased.
In such a case, leakage current will gradually decrease by applying voltage (withinthe category voltage and the upper
limit of category temperature).
1.4 Rapid charge and discharge limitation
Allowance of a large rush current to flow due to rapid charge and discharge may result in short circuit or large leakage
current. The protection circuit, to maintain high reliability, is recommended when rush current to flow to the OS-CON
is in the following cases.
(1) Products which 10 times of allowable ripple current is less than 10 A : It is when 10 A or over of rush current is
applied.
(2) Products which 10 times of allowable ripple current is 10 A or over : It is when rush current, which the figure is over
10 times of allowable ripple current, is applied.
05-Mar-21
Conductive Polymer Aluminum Solid Capacitors
2. Mounting
2.1 Soldering with a soldering iron
(1) When lead terminals for radial lead type must be processed because the lead pitch and the PCB holes do not match,
process them without any stresses to the OS-CON before soldering.
(2) Solder without any excessive stresses to the OS-CON itself.
(3) When the OS-CON has been soldered once and needs to be removed, remove it after the solder has been completely
melted.
(4) Do not let the tip of the soldering iron touch the OS-CON itself.
2.2 Flow soldering
(1) Do not apply flow soldering to OS-CON SMD type.
(2) Do not solder the OS-CON itself by submerging it in melted solder.
(3) Solder the opposite side that the OS-CON is mounted on.
(4) Note that flux does not adhere to anywhere expect the lead terminal.
(5) Note that other components do not fall over and touch the OS-CON when soldering.
2.3 Reflow soldering
(1) Do not apply reflow soldering to OS-CON Radial Lead type.
(2) Please contact us for setting VPS conditions.
2.4 Capacitor handling after soldering
Do not subject the OS-CON to excessive stress as follows.
(1) Do not tilt, bend or twist the OS-CON.
(2) Do not move the PCB with holding the OS-CON itself.
(3) Do not hit the OS-CON with objects.
(4) When stacking PCBs, make sure that the OS-CON does not touch other PCBs or components.
2.5 Circuit board cleaning
Check the following items before washing PC board with these detergents: high quality alcohol-based cleaning fluid
such as Pine-a ST-100S, clean thru 750H, 750L, 710M, 750K or Techno Care FRW 14 through 17 or detergents
including substitute freon as AK-225AES or IPA.
(1) Use immersion or ultrasonic waves to clean within 2 minutes.
(2) The temperature of the cleaning fluid should be less than 60 °C.
(3) Watch the contamination of the detergent such as conductivity, pH, specific gravity, water content, etc.
(4) Do not store the OS-CON in a location subject to gases from the cleaning fluid or in an airtight container after
cleaning.
(5) Dry the PCB or OS-CON with hot air that should be less than the upper category temperature.
(6) Please note that indication may disappear when rubbing print side after washing depending on a cleaner.
(7) Please contact us for details about detergents, cleaning methods and detergents other than those listed
above.
2.6 Fixatives and coating materials
(1) Select the appropriate covering and sealant materials for the OS-CON. In particular, don’t use acetone in the fixative,
coating agent and diluent.
(2) Before applying the fixative or coating, completely remove any flux residue and foreign matter from the area where
the board and the OS-CON will be jointed together.
(3) Allow any detergent to dry before applying the fixative or coating.
(4) Please contact us for the fixative and coating heat curing conditions.
2.7 Capacitor insulation
Be sure to completely separate the case, negative lead terminal, positive lead terminal and PC board patterns with each
other due to the following reasons.
(1) Insulation is not guaranteed at a part of resin on the surface of a case.
(2) It offers inconstant resistance between a case and a negative lead terminal and it isn’t insulated.
05-Mar-21
Conductive Polymer Aluminum Solid Capacitors
3. Storage
Open the bags just before mounting and use up all products once opened,
For keeping a good solderability, store the OS-CON as follows.
Before unsealing
SMD type*1
Radial
lead type
Within 24 months after shipment
Bag packing product
Within 30 months after shipment
Taping product
Within 24 months after shipment
After unsealing
Within 30 days from opening
(packaged with carrier tape)
Within 7 days from opening
*1 : The JEDEC J-STD-020 standard is not applicable
✽ Intellectual property right
We, Panasonic Group are providing the product and service that customers can use without anxiety, and are working
positively on the protection of our products underintellectual property rights.
Representative patents relating to OS-CON are as follows:
US Patent No.7158367
05-Mar-21