ABS1114509

ABS1114509

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    检测开关 单刀双掷 操作寿命500万次 DC30V 2A AC125V 2A

  • 数据手册
  • 价格&库存
ABS1114509 数据手册
For detection: Seal Type Switches ABS ( BS ) Turquoise Switches Product Catalog 2023.1 For detection: Seal Type Switches ABS (BS) Turquoise Switches Subminiature Size Sealed Switches FEATURES Terminal type Subminiature Size high sealing performance sealed switches Elastomer (elastic material) double molding technology contributes to stable sealing quality Superior operating position precision Wire leads TYPICAL APPLICATIONS Automotive (detection of door opening and closing) Vacuum cleaner $LUSXUL¿HU Gas cooking range Personal hygiene systems ORDERING INFORMATION (PART NO.) ABS Terminal 1: .110 quickconnect 4: Solder terminal terminal 5: P/C board terminal 6: Wire leads Wire and terminal position 1: Straight 4: Right type angle 5: Left angle Safety standard (Terminal type only) Null: Safety standard un-acquiring 3 : UL/C-UL, ENEC/VDE (AgNi alloy*,CuNi alloy + AgNi alloy + Au-clad triple layer contact type only) (*OF 1.47 N only, Note) OF by pin plunger) 9 : UL/C-UL (CuNi alloy + Au-clad double layer contact type only) Operating Force (OF) by pin plunger (Max.) 4: 0.98 N 5: 1.47 N Actuator 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 6: Hinge roller lever 8: Leaf lever (with wire lead) Contact form 3: SPST-N.O. 1: SPDT 2: SPST-N.C. (Wire leads type only) (Wire leads type only) COM N.O. N.C. COM Contact material 0: AgNi alloy contact 1: CuNi alloy+AgNi alloy +Au-clad triple layer contact 4: CuNi alloy+Au-clad double layer contact COM N.O. N.C. Note) Not every combination is available. Please refer to the following table, PRODUCT TYPES . AgNi alloy Au-clad AgNi alloy CuNi alloy Au-clad CuNi alloy TERMINAL AND WIRE LEAD POSITION P/C board angle terminals P/C board right angle terminal (ABS4******) Wire leads position P/C board left angle terminal (ABS5******) Wire leads straight type (ABS1******) Wire leads right angle type (ABS4******) Wire leads left angle type (ABS5******) Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー1ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches TYPES Terminal type 1) AgNi alloy contact Actuator P/C board terminal Operating Force (OF) Max. .110 quick-connect terminal Solder terminal 0.98 N ABS111040 1.47 N ABS111050 0.39 N Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Standard terminal Right angle terminal Left angle terminal ABS141040 ABS151040 ABS451040 ABS551040 ABS141050 ABS151050 ABS451050 ABS551050 ABS111140 ABS141140 ABS151140 ABS451140 ABS551140 0.59 N ABS111150 ABS141150 ABS151150 ABS451150 ABS551150 0.34 N ABS111240 ABS141240 ABS151240 ABS451240 ABS551240 0.54 N ABS111250 ABS141250 ABS151250 ABS451250 ABS551250 0.25 N ABS111340 ABS141340 ABS151340 ABS451340 ABS551340 0.44 N ABS111350 ABS141350 ABS151350 ABS451350 ABS551350 0.34 N ABS111440 ABS141440 ABS151440 ABS451440 ABS551440 0.54 N ABS111450 ABS141450 ABS151450 ABS451450 ABS551450 0.39 N ABS111640 ABS141640 ABS151640 ABS451640 ABS551640 0.59 N ABS111650 ABS141650 ABS151650 ABS451650 ABS551650 Notes: 1. Please order addition 3 at the end of the part number for safety standard type. (Only 50 at the end of the part number) 2. Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Actuator P/C board terminal Operating Force (OF) Max. .110 quick-connect terminal Solder terminal 0.98 N ABS111041 1.47 N ABS111051 0.39 N Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Standard terminal Right angle terminal Left angle terminal ABS141041 ABS151041 ABS451041 ABS551041 ABS141051 ABS151051 ABS451051 ABS551051 ABS111141 ABS141141 ABS151141 ABS451141 ABS551141 0.59 N ABS111151 ABS141151 ABS151151 ABS451151 ABS551151 0.34 N ABS111241 ABS141241 ABS151241 ABS451241 ABS551241 0.54 N ABS111251 ABS141251 ABS151251 ABS451251 ABS551251 0.25 N ABS111341 ABS141341 ABS151341 ABS451341 ABS551341 0.44 N ABS111351 ABS141351 ABS151351 ABS451351 ABS551351 0.34 N ABS111441 ABS141441 ABS151441 ABS451441 ABS551441 0.54 N ABS111451 ABS141451 ABS151451 ABS451451 ABS551451 0.39 N ABS111641 ABS141641 ABS151641 ABS451641 ABS551641 0.59 N ABS111651 ABS141651 ABS151651 ABS451651 ABS551651 Notes: 1. Please order addition 3 at the end of the part number for safety standard type. 2. Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Actuator P/C board terminal Operating Force (OF) Max. .110 quick-connect terminal Solder terminal 0.98 N ABS111044 1.47 N ABS111054 0.39 N Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Standard terminal Right angle terminal Left angle terminal ABS141044 ABS151044 ABS451044 ABS551044 ABS141054 ABS151054 ABS451054 ABS551054 ABS111144 ABS141144 ABS151144 ABS451144 ABS551144 0.59 N ABS111154 ABS141154 ABS151154 ABS451154 ABS551154 0.34 N ABS111244 ABS141244 ABS151244 ABS451244 ABS551244 0.54 N ABS111254 ABS141254 ABS151254 ABS451254 ABS551254 0.25 N ABS111344 ABS141344 ABS151344 ABS451344 ABS551344 0.44 N ABS111354 ABS141354 ABS151354 ABS451354 ABS551354 0.34 N ABS111444 ABS141444 ABS151444 ABS451444 ABS551444 0.54 N ABS111454 ABS141454 ABS151454 ABS451454 ABS551454 0.39 N ABS111644 ABS141644 ABS151644 ABS451644 ABS551644 0.59 N ABS111654 ABS141654 ABS151654 ABS451654 ABS551654 Notes: 1. Please order addition 9 at the end of the part number for safety standard type. 2. Push plunger color: green Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches 3 wire leads type (SPDT) 1) AgNi alloy contact Actuator SPDT Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS161040 ABS461040 ABS561040 1.47 N ABS161050 ABS461050 ABS561050 0.39 N ABS161140 ABS461140 ABS561140 0.59 N ABS161150 ABS461150 ABS561150 0.34 N ABS161240 ABS461240 ABS561240 0.54 N ABS161250 ABS461250 ABS561250 0.25 N ABS161340 ABS461340 ABS561340 0.44 N ABS161350 ABS461350 ABS561350 0.34 N ABS161440 ABS461440 ABS561440 0.54 N ABS161450 ABS461450 ABS561450 0.39 N ABS161640 ABS461640 ABS561640 0.59 N ABS161650 ABS461650 ABS561650 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Actuator SPDT Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS161041 ABS461041 ABS561041 1.47 N ABS161051 ABS461051 ABS561051 0.39 N ABS161141 ABS461141 ABS561141 0.59 N ABS161151 ABS461151 ABS561151 0.34 N ABS161241 ABS461241 ABS561241 0.54 N ABS161251 ABS461251 ABS561251 0.25 N ABS161341 ABS461341 ABS561341 0.44 N ABS161351 ABS461351 ABS561351 0.34 N ABS161441 ABS461441 ABS561441 0.54 N ABS161451 ABS461451 ABS561451 0.39 N ABS161641 ABS461641 ABS561641 0.59 N ABS161651 ABS461651 ABS561651 Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS161044 ABS461044 ABS561044 1.47 N ABS161054 ABS461054 ABS561054 0.39 N ABS161144 ABS461144 ABS561144 0.59 N ABS161154 ABS461154 ABS561154 0.34 N ABS161244 ABS461244 ABS561244 0.54 N ABS161254 ABS461254 ABS561254 0.25 N ABS161344 ABS461344 ABS561344 0.44 N ABS161354 ABS461354 ABS561354 0.34 N ABS161444 ABS461444 ABS561444 0.54 N ABS161454 ABS461454 ABS561454 0.39 N ABS161644 ABS461644 ABS561644 0.59 N ABS161654 ABS461654 ABS561654 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPDT Note: Push plunger color: green Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー3ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches 2 wire leads type (SPST-N.C.) 1) AgNi alloy contact Actuator SPST-N.C. Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS162040 ABS462040 ABS562040 1.47 N ABS162050 ABS462050 ABS562050 0.39 N ABS162140 ABS462140 ABS562140 0.59 N ABS162150 ABS462150 ABS562150 0.34 N ABS162240 ABS462240 ABS562240 0.54 N ABS162250 ABS462250 ABS562250 0.25 N ABS162340 ABS462340 ABS562340 0.44 N ABS162350 ABS462350 ABS562350 0.34 N ABS162440 ABS462440 ABS562440 0.54 N ABS162450 ABS462450 ABS562450 0.39 N ABS162640 ABS462640 ABS562640 0.59 N ABS162650 ABS462650 ABS562650 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Actuator SPST-N.C. Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS162041 ABS462041 ABS562041 1.47 N ABS162051 ABS462051 ABS562051 0.39 N ABS162141 ABS462141 ABS562141 0.59 N ABS162151 ABS462151 ABS562151 0.34 N ABS162241 ABS462241 ABS562241 0.54 N ABS162251 ABS462251 ABS562251 0.25 N ABS162341 ABS462341 ABS562341 0.44 N ABS162351 ABS462351 ABS562351 0.34 N ABS162441 ABS462441 ABS562441 0.54 N ABS162451 ABS462451 ABS562451 0.39 N ABS162641 ABS462641 ABS562641 0.59 N ABS162651 ABS462651 ABS562651 Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS162044 ABS462044 ABS562044 1.47 N ABS162054 ABS462054 ABS562054 0.39 N ABS162144 ABS462144 ABS562144 0.59 N ABS162154 ABS462154 ABS562154 0.34 N ABS162244 ABS462244 ABS562244 0.54 N ABS162254 ABS462254 ABS562254 0.25 N ABS162344 ABS462344 ABS562344 0.44 N ABS162354 ABS462354 ABS562354 0.34 N ABS162444 ABS462444 ABS562444 0.54 N ABS162454 ABS462454 ABS562454 0.39 N ABS162644 ABS462644 ABS562644 0.59 N ABS162654 ABS462654 ABS562654 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-N.C. Note: Push plunger color: green Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー4ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches 2 wire leads type (SPST-N.O.) 1) AgNi alloy contact Actuator SPST-N.O. Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS163040 ABS463040 ABS563040 1.47 N ABS163050 ABS463050 ABS563050 0.39 N ABS163140 ABS463140 ABS563140 0.59 N ABS163150 ABS463150 ABS563150 0.34 N ABS163240 ABS463240 ABS563240 0.54 N ABS163250 ABS463250 ABS563250 0.25 N ABS163340 ABS463340 ABS563340 0.44 N ABS163350 ABS463350 ABS563350 0.34 N ABS163440 ABS463440 ABS563440 0.54 N ABS163450 ABS463450 ABS563450 0.39 N ABS163640 ABS463640 ABS563640 0.59 N ABS163650 ABS463650 ABS563650 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Actuator SPST-N.O. Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS163041 ABS463041 ABS563041 1.47 N ABS163051 ABS463051 ABS563051 0.39 N ABS163141 ABS463141 ABS563141 0.59 N ABS163151 ABS463151 ABS563151 0.34 N ABS163241 ABS463241 ABS563241 0.54 N ABS163251 ABS463251 ABS563251 0.25 N ABS163341 ABS463341 ABS563341 0.44 N ABS163351 ABS463351 ABS563351 0.34 N ABS163441 ABS463441 ABS563441 0.54 N ABS163451 ABS463451 ABS563451 0.39 N ABS163641 ABS463641 ABS563641 0.59 N ABS163651 ABS463651 ABS563651 Operating Force (OF) Max. Bottom type Right side type Left side type 0.98 N ABS163044 ABS463044 ABS563044 1.47 N ABS163054 ABS463054 ABS563054 0.39 N ABS163144 ABS463144 ABS563144 0.59 N ABS163154 ABS463154 ABS563154 0.34 N ABS163244 ABS463244 ABS563244 0.54 N ABS163254 ABS463254 ABS563254 0.25 N ABS163344 ABS463344 ABS563344 0.44 N ABS163354 ABS463354 ABS563354 0.34 N ABS163444 ABS463444 ABS563444 0.54 N ABS163454 ABS463454 ABS563454 0.39 N ABS163644 ABS463644 ABS563644 0.59 N ABS163654 ABS463654 ABS563654 Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-N.O. Note: Push plunger color: green Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches 3 wire leads type/Leaf lever type (SPDT) 1) AgNi alloy contact Operating force Max. SPDT Bottom type Right side type Left side type 0.88 N ABS161840 ABS461840 ABS561840 1.08 N ABS161850 ABS461850 ABS561850 Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Operating force Max. SPDT Bottom type Right side type Left side type 0.88 N ABS161841 ABS461841 ABS561841 1.08 N ABS161851 ABS461851 ABS561851 Bottom type Right side type Left side type 0.88 N ABS161844 ABS461844 ABS561844 1.08 N ABS161854 ABS461854 ABS561854 Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Operating force Max. SPDT Note: Push plunger color: green 2 wire leads type/Leaf lever type (SPST-N.C.) 1) AgNi alloy contact Operating force Max. SPST-N.C. Bottom type Right side type Left side type 0.88 N ABS162840 ABS462840 ABS562840 1.08 N ABS162850 ABS462850 ABS562850 Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Operating force Max. SPST-N.C. Bottom type Right side type Left side type 0.88 N ABS162841 ABS462841 ABS562841 1.08 N ABS162851 ABS462851 ABS562851 Bottom type Right side type Left side type 0.88 N ABS162844 ABS462844 ABS562844 1.08 N ABS162854 ABS462854 ABS562854 Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Operating force Max. SPST-N.C. Note: Push plunger color: green 2 wire leads type/Leaf lever type (SPST-N.O.) 1) AgNi alloy contact Operating force Max. SPST-N.O. Bottom type Right side type Left side type 0.88 N ABS163840 ABS463840 ABS563840 1.08 N ABS163850 ABS463850 ABS563850 Note: Push plunger color: black 2) CuNi alloy + AgNi alloy + Au-clad triple layer contact Operating force Max. SPST-N.O. Bottom type Right side type Left side type 0.88 N ABS163841 ABS463841 ABS563841 1.08 N ABS163851 ABS463851 ABS563851 Bottom type Right side type Left side type 0.88 N ABS163844 ABS463844 ABS563844 1.08 N ABS163854 ABS463854 ABS563854 Note: Push plunger color: dark red 3) CuNi alloy + Au-clad double layer contact Operating force Max. gf SPST-N.O. Note: Push plunger color: green Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー6ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches RATING Coil data Item 6SHFL¿FDWLRQV &RQWDFWVSHFL¿FDWLRQV Au-clad contact type AgNi alloy contact type Triple layer contact type Double layer contact type Load style Resistive load ,QGXFWLYHORDG FRVij0.7) Resistive load Resistive load 125 V AC 2A 2A 0.1 A — 250 V AC 2A 2A 0.1 A — 30 V DC 2A 2A 0.1 A 0.1 A 125 V DC 0.4 A 0.05 A — — Note: Inductive load with direct current is 7 ms time constant or less. Low-level circuit rating (Au-clad contact type) Rated voltage Resistive load 6 V DC 5 mA 12 V DC 2 mA 24 V DC 1 mA 6SHFL¿FDWLRQV Item Expected life 6SHFL¿FDWLRQV 0HFKDQLFDOOLIH 276SHFL¿HGYDOXH Electrical life (OT: Max.) AgNi alloy contact type Min. 5 x 104 (at 20 cpm) (at rated load) Au-clad contact type Min. 2 x 105 (at 20 cpm) (at rated load) Insulation resistance Dielectric strength Leaf lever: Min. 5 x 105 (at 60 cpm), Other types: Min. 5 x 106 (at 60 cpm) Between non-continuous terminals Min. 1000ȍ DW500 V DC insulation resistance meter) 1,000 Vrms for 1 min Between each terminal and other exposed metal parts 1,500 Vrms for 1 min Between each terminal and ground 1,500 Vrms for 1 min Vibration resistance (Pin plunger type) 10 to 55 Hz at single amplitude of 0.75 mm (Contact opening Max. 1 msec) Shock resistance (Pin plunger type) Min. 294 m/s2 (Contact opening Max. 1 msec) Contact resistance (Initial) AgNi alloy contact type Terminal type Max. 50Pȍ Wire leads: Max. 100Pȍ (by voltage drop 1 A 6 to 8 V DC) Au-clad contact type Terminal type: Max. 100Pȍ Wire leads: Max. 150Pȍ (by voltage drop 0.1 A 6 to 8 V DC) Allowable operating speed (at no load) 0.1 to 500 mm/sec (at pin plunger position) Max. operating cycle rate (at no load) 120 cpm Ambient temperature –40 to +85°C Unit weight Approx. 2 g (Terminal type) Protection grade IP67 (except exposed terminal part of terminal type) Note: Test conditions and judgement are complying with “NECA C 4505”. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー7ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Operating characteristics Type of actuator 8th digit of Part No. Operating Force (OF) Max. Release Force (RF) Min. Pretravel (PT) Max. Movement 'LႇHUHQWLDO (MD) Max. Overtravel (OT) Min. Operating Position (OP) 4 0.98 N 0.15 N 0.6 mm 0.1 mm 0.4 mm 8.4±0.3 mm 5 1.47 N 0.20 N 0.6 mm 0.1 mm 0.4 mm 8.4±0.3 mm 4 0.39 N 0.034 N 2.5 mm 0.5 mm 0.8 mm 8.8±0.8 mm 5 0.59 N 0.039 N 2.5 mm 0.5 mm 0.8 mm 8.8±0.8 mm 4 0.34 N 0.029 N 2.8 mm 0.8 mm 1.2 mm 8.8±0.8 mm 5 0.54 N 0.034 N 2.8 mm 0.8 mm 1.2 mm 8.8±0.8 mm 4 0.25 N 0.025 N 3.5 mm 1.0 mm 1.6 mm 8.8±1.2 mm 5 0.44 N 0.029 N 3.5 mm 1.0 mm 1.6 mm 8.8±1.2 mm 4 0.34 N 0.029 N 2.8 mm 0.8 mm 1.2 mm 11.65±0.8 mm 5 0.54 N 0.034 N 2.8 mm 0.8 mm 1.2 mm 11.65±0.8 mm 4 0.39 N 0.034 N 2.5 mm 0.5 mm 0.8 mm 14.5±0.8 mm 5 0.59 N 0.039 N 2.5 mm 0.5 mm 0.8 mm 14.5±0.8 mm 4 0.88 N 0.17 N 4.5 mm 1.0 mm 2.5 mm 14.5±1.5 mm 5 1.08 N 0.20 N 4.5 mm 1.0 mm 2.5 mm 14.5±1.5 mm Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Leaf lever DATA Guidelines for selecting contact materials for load voltage and current 2A AgNi alloy 100 mA Au triple layer contact type Au double layer contact type 1 mA 0 DC AC 5 5 15 30 V 30 250 V Note) If the contact is being used in the constant lowlevel circuit load range, the Au-clad double layer contact is recommended. If there is a danger of the current being less than 0.5 A, for instance if the contact is being turned on and off, the Auclad triple layer contact type is recommended. The diagram above is intended as a reference. Please use the product within the rated voltage and current. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー8ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches DIMENSIONS Unit: mm CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website. .110 quick-connect terminal CAD Pin plunger 7.6±0.3 NO 5.5±0.1 11.0 7.1±0.15 2.4 NC Operating Position (OP) 8.4±0.3 6.7 C 3.4±0.15 7.7 2.4+0.1 −0.05 φ1.7 11.8±0.4 Pre travel (PT) Max. 0.6 External dimensions φ2.4+0.1 −0.05 C 0.6 φ1.2±0.05 2.5±0.1 9.5±0.1 t=0.5 2.8±0.1 4.0 Pretravel (PT) Max. 0.6 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 0.1 mm Overtravel (OT) Min. 0.4 mm 5.2 6.4±0.2 7.6±0.15 7.6±0.15 19.8±0.3 Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 8.4±0.3 mm Distance from VWDQGRႇ 11.8±0.4 mm Short hinge lever NC 12.2±0.9 C 4.0 (3.7) Operating Position (OP) 8.8±0.8 5.0±0.4 6.3 12.85 Pre travel (PT) Max. 2.5 External dimensions NO Pretravel (PT) Max. 2.5 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 0.5 mm Overtravel (OT) Min. 0.8 mm Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 8.8±0.8 mm Distance from VWDQGRႇ 12.2±0.9 mm Hinge lever NC 4.0 (3.7) 12.2±0.9 C Operating Position (OP) 8.8±0.8 7.15±0.4 Pre travel (PT) Max. 2.8 External dimensions NO Pretravel (PT) Max. 2.8 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 0.8 mm Overtravel (OT) Min. 1.2 mm Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 8.8±0.8 mm Distance from VWDQGRႇ 12.2±0.9 mm Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー9ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Long hinge lever Pre travel (PT) Max. 3.5 External dimensions NC 4.0 (3.5) 12.2±1.3 C Operating Position (OP) 8.8±1.2 13.1±0.4 NO Pretravel (PT) Max. 3.5 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 1.0 mm Overtravel (OT) Min. 1.6 mm Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 8.8±1.2 mm Distance from VWDQGRႇ 12.2±1.3 mm Simulated roller lever NC 4.0 (3.5) 15.05±0.9 C Operating Position (OP) 11.65±0.8 R 2.5 6.3±0.4 Pre travel (PT) Max. 2.8 External dimensions NO Pretravel (PT) Max. 2.8 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 0.8 mm Overtravel (OT) Min. 1.2 mm Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 11.65±0.8 mm Distance from VWDQGRႇ 15.05±0.9 mm Roller lever C NC φ5.0 3.2 17.9±0.9 5.15±0.4 Operating Position (OP) 14.5±0.8 Pre travel (PT) Max. 2.5 External dimensions NO Pretravel (PT) Max. 2.5 mm 0RYHPHQW'LႇHUHQWLDO 0' 0D[ 0.5 mm Overtravel (OT) Min. 0.8 mm Operating Position (OP) General tolerance: ±0.25 Distance from mounting hole 14.5±0.8 mm Distance from VWDQGRႇ 17.9±0.9 mm Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 10 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Solder terminal External dimensions CAD 7.6±0.3 φ2.4+0.1 −0.05 2.8±0.2 2.5±0.1 9.5±0.1 0.5 1.25±0.1 8.7±0.15 5.2 15.4±0.15 1.85±0.2 1.5±0.12 2.4 NC NO 2.4 7.4 1.9 1.1±0.12 6.7 C 3.4±0.15 7.7 2.4+0.1 −0.05 φ1.7 6.4±0.2 19.8±0.3 General tolerance: ±0.25 Note) Dimensions of the actuator types are the same as those of corresponding .110 quick-connect terminal types. P/C board terminal External dimensions CAD Bottom type P/C board pattern 7.6±0.3 3-φ1.2±0.05 8.7±0.1 1.1±0.12 NC φ2.4+0.1 −0.05 0.9 2.5±0.1 9.5±0.1 2.2 3.4±0.15 2.4 7.4 NO 0.5 1.25±0.1 8.7±0.15 5.2 15.4±0.15 1.5±0.12 2.4 C 1.85±0.2 15.4±0.1 6.7 +0.1 −0.05 7.7 φ1.7 6.4±0.2 19.8±0.3 General tolerance: ±0.25 Note) Dimensions of the actuator types are the same as those of corresponding .110 quick-connect terminal types. P/C board right side terminal External dimensions CAD P/C board pattern 1.3 3-φ1.5±0.05 6-C0.3 5.08±0.2 7.62±0.1 7.62±0.1 C NC 0.5 NO 6.4 7.62±0.15 7.62±0.15 General tolerance: ±0.25 Note) Dimensions of the actuator types are the same as those of corresponding .110 quick-connect terminal types. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 11 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches P/C board left side terminal External dimensions CAD P/C board pattern 3-φ1.5±0.05 7.62±0.1 7.62±0.1 6-C 0.3 5.08±0.2 1.3 C NC 0.5 NO 7.62±0.15 7.62±0.15 6.4 General tolerance: ±0.25 Note) Dimensions of the actuator types are the same as those of corresponding .110 quick-connect terminal types. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 12 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Wire leads CAD Wire leads bottom type External dimensions 7.6±0.3 Wire lead thickness: 0.5 mm2 Wire lead color : COM…Black N.O. …White N.C. …Red 6.7 7.7 2.4+0.1 −0.05 φ1.7 NC C NO 9.2 2.5±0.1 SPST-N.C. φ2.4+0.1 −0.05 9.5±0.1 5±2 300±10 SPDT SPST-N.O. 21.2±0.4 6.4 General tolerance: ±0.25 Note) Other dimensions are the same as those of .110 quick-connect terminal types. Dimensions of the actuator types are the same as those of corresponding . 110 quick-connect terminal types. Wire leads right side type External dimensions NC C 8.4±0.4 NO 5±2 23.8±0.4 300±10 6.4 General tolerance: ±0.25 Wire leads left side type External dimensions NC C 8.4±0.4 NO 5±2 300±10 23.8±0.4 6.4 General tolerance: ±0.25 Note) For wire leads right angle type and left angle type, the wire lead is changed to UL compliant (AWG20). Color of the wire is same as straight type. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 13 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Wire leads leaf lever type CAD Wire leads bottom type 5.0 Free position (FP) (16.5) Operating Position(OP) 14.5±1.5 Totaltravel position (TTP) (Min. 10.5) NC C Wire lead thickness: 0.5 mm2 Wire lead color : COM…Black N.O. …White N.C. …Red 8.4±0.4 NO 2.5±0.1 φ2.4+0.1 −0.05 9.5±0.1 6.4 5±2 300±10 1.5 6.7 7.7 2.4+0.1 −0.05 8.0±1.0 Pre travel (PT) Max. 4.5 External dimensions 23.8±0.4 General tolerance: ±0.25 Wire leads right side type External dimensions 5.0 NC C 8.4±0.4 NO 5±2 23.8±0.4 6.4 300±10 General tolerance: ±0.25 Wire leads left side type External dimensions 5.0 NO 8.4±0.4 NC C 5±2 300±10 23.8±0.4 6.4 General tolerance: ±0.25 Note) For wire leads right angle type and left angle type, the wire lead is changed to UL compliant (AWG20). Color of the wire is same as straight type. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 14 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 ABS (BS) Turquoise Switches Please refer to WKHODWHVWSURGXFWVSHFL¿FDWLRQV when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 15 ー Panasonic Industry Co., Ltd. 2023 AECTB2E 202301 Notes for Turquoise Switches (BJ, BS, BV type) CAUTIONS FOR USE (Common for BJ, BS and BV types) Fastening of the switch body Cautions regarding use 1) Fasten the switch body onto a smooth surface using the correct screw as shown in the chart below and tighten it with the prescribed torque. The switch case may deform depending on the type of screw (screw head diameter, etc.), the size of the washer, and the use or non-use RIDZDVKHU7KHUHIRUHSOHDVHFRQ¿UPWKHDSSURSULDWHWRUTXHRI actual conditions. Also, it is recommended that adhesive be applied to lock the screws to prevent loosening of the screws. When doing so, please be careful not let any adhesive get inside the switch. Screws Tightening torque M1.2 Not more than 0.098 N·m M2.3 Not more than 0.29 N·m M3.0 Not more than 0.29 N·m ABS (BS) switches M2.3 Not more than 0.29 N·m ABV (BV) switches M3.0 Not more than 0.49 N·m ABJ (BJ) switches 2) Fixed pin type 7RVHFXUHWKHVZLWFKXQLWWKHUPDOO\FULPSRUSUHVV¿WWKHPRXQWLQJ SLQV,IWKHSLQVDUHWREHSUHVV¿WWHGLQVWDOODJXLGHRQWKHRSSRVLWH surface to the mounting pins to prevent them from slipping out of position and developing play. 3) Be sure to maintain adequate insulating clearance between each terminal and ground. 4) The positioning of the switch should be such that direct force is not applied to the pushbutton or actuator in its free position. The operating force to the pushbutton should only be applied in a perpendicular direction. 5) The standard value of overtravel used should be within the range of 70% to 100% of the rated OT value. 6) When soldering the BV type turquoise switch or the immersion protected type of the BJ and BS type switches, the sealing material sometimes forms a lump or bulge at the base of the terminal or lead. Be sure to allow enough space for this when attaching the switch. Soldering operations 1) Manual soldering: Perform soldering in less than 3 seconds with maximum 350 C iron. Care should be taken not to apply force to the terminals during soldering. We recommend a soldering iron with temperature adjustment in order to prevent poor quality soldering. Please consult us if you intend to use a soldering iron of 60 W or higher. 2) Terminal portions should not be moved within 1 minute after soldering. 1) When switching inductive loads (relays, solenoids, buzzers, etc.), an arc absorbing circuit is recommended to protect the contacts. 2) If switching of the contact is synchronized with the phase of the AC power, reduced electrical life or welded contact may occur. Therefore, test the switch while it is operating under actual loads for this condition. If found, you may wish to take corrective action in your design. 3) In the slow or high speed operating condition, the electrical life might be greatly reduced depending upon the switching load. Please consult us before use. 4) Using lever type in do not condition, there is the concern that the ÀH[LEOHSDUWPD\EHLPSHGHGDQGUHWXUQPRYHPHQWPD\QRWEH possible. In this situation take the following precautions: • Select a product of higher OF or use a leaf type lever. • Attach a protective cover to the lever. 5) If the leaf lever type switch is excessively pushed (pushed further than the operational limit position) or switching is done at high speed or is accompanied by the impact, the lever will break. Please be careful. Also, be careful with the short roller lever type ABV (BV) switch as improper return may result from pressing too much. Protection from dust, water and corrosive gas 1) The pin button and the space around the body cap Turquoise switches are sealed with elastic material, the terminal portion is integrally molded. This prevents dust entry and protects the switch against corrosive gases. Wireleaded types are recommended for applications subject to water or oil splash. However, avoid soaking these immersion protected types in oil or water, because those types are not of completely oil tight construction. 2) Switch operation or rapid temperature change while water droplets are on the switch may cause the water invasion inside the switch because of breathing action on condensation. Especially do not use switch in a bath. If sources of silicon gas are existing in the vicinity of the switch VLOLFRQUXEEHUVLOLFRQRLOVLOLFRQFRDWLQJDQGVLOLFRQ¿OOHUHWF  silicon gas (low molecular siloxane, etc.) will be emitted and it will get into the product due to the permeability of the plastic. If the switch is used or stored in such an environment, silicon compound might generate on the contacts, cause the and faulty contacting. Therefore, please do not use sources that can emit silicon gas in the vicinity of the switch. 'RQRWXVHLQDUHDVZKHUHÀDPPDEOHRUH[SORVLYHJDVHVIURP gasoline and thinner, etc., may be present. Soldering time ABJ (BJ) switches Within 3 seconds ABS (BS) switches Within 3 seconds ABV (BV) switches Within 5 seconds Selection of the switch $OORZIRUXSWRYDULDWLRQRIWKHVSHFL¿HGFKDUDFWHULVWLFVYDOXHV to compensate for long term operational wear of the switch in your design. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 16 ー Panasonic Industry Co., Ltd. 2022 AECTB35E 202204 Notes for Turquoise Switches (BJ, BS, BV type) 1Ω 100 mΩ 100 Ω Typical products 10 Ω 1Ω 100 mΩ Turquoise switches 10 mΩ 0 Standard value 8 hours 10 mΩ 100 200 300 400 500 Elapsed time (h) Oil-proof and chemical-proof characteristics 2 4 6 The rubber elastomer swells when exposed to oil and chemicals. The extent of swelling will vary widely depending on the type and amount of oil and chemicals. Check with the actual oil or chemicals used. In particular, be aware that solvents such as freon, chlorine, and toluene cannot be used. 8 10 12 14 16 18 20 22 24 Elapsed time (h) Waterproof test Test conditions: Immersion protected IP67 switches ... Submerge at 1 m below the water surface for 30 minutes. Insulation resistance (MΩ)  \GURJHQVXO¿GHH[SRVXUHWHVW + Test conditions: Concentration: 3 ppm, Temperature: 40 °C, Humidity: 75% RH Contact resistance Contact resistance Dust protection test Test conditions: The talcum powder used shall be able to pass through a square- meshed sieve the nominal wire GLDPHWHURIȝP7KHDPRXQWRIWDOFXPSRZGHUWR be used is 2 kg per cubic metre of the test chamber volume. The duration of the test is 8 hours. No damage observed after the test. Washability [ABJ (BJ) and ABS (BS)] Do not clean the switch. Doing so can cause problems. Please contact us if cleaning is necessary. 1000 100 10 Standard value 30 minutes 2 4 6 8 10 12 14 16 18 20 22 24 Elapsed time (h) Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 17 ー Panasonic Industry Co., Ltd. 2022 AECTB35E 202204 Notes for Turquoise Switches (BJ, BS, BV type) REFERENCE Dust-protected type This type of construction prevents dust that is large enough to KDYHDQHႇHFWRQRSHUDWLRQIURPJHWWLQJLQVLGHWKHXQLW7KLV construction is stipulated by protective classes against solid matter in the IEC standards (IEC60529). The talcum powder used shall be able to pass through a VTXDUHPHVKHGVLHYHWKHQRPLQDOZLUHGLDPHWHURIȝP7KH amount of talcum powder to be used is 2 kg per cubic metre of the test chamber volume. The duration of the test is 8 hours. No damage observed after the test. Level of protection indicated by the 1st Characteristics number 1st Characteristics number 0 No protection 1 Protected against solid matter larger than 50 mm 2 Protected against solid matter larger than 12 mm 3 Protected against solid matter larger than 2.5 mm 4 Protected against solid matter larger than 1.0 mm 5 Dust-protected type 3UHYHQWVGXVWWKDWLVODUJHHQRXJKWRKDYHDQHႇHFW on operation from getting inside the unit 6 Dust-resistant type Prevents dust from getting inside the unit Immersion-protected type 7KLVW\SHRIFRQVWUXFWLRQSUHYHQWVDQ\KDUPIXOHႇHFWVHYHQDIWHUWKH device is left underwater at a depth of 1 m for 30 minutes. This construction is stipulated by protective classes against water in the IEC standards (IEC60529). IEC’s IP Codes Level of protection indicated by the 2nd Characteristics number 7KH,(& ,QWHUQDWLRQDO(OHFWURWHFKQLFDO&RPPLVVLRQ KDVGH¿QHG the IP characteristic code that represents the levels of protection described in IEC standard (IEC60529). The two numbers that follow the IP code (the characteristics numbers) indicate the suitability of this protection for all environmental conditions. 1st characteristics number Protection level (IEC60529/Solid matter) JIS C 0920 IP 2nd characteristics number 2nd Characteristics Protection level (IEC60529/Liquid matter) number 0 No protection Droplet-protected type I 1 Protected against water droplets that fall perpendicular to the unit Droplet-protected type II 2 Protected against water droplets that fall from within 15° of perpendicular to the unit Rain-protected type 3 Protected against water droplets that fall from within 60° of perpendicular to the unit Splash-protected type 4 Protected against water that splashes on the unit from any direction Spray-protected type 5 )UHHIURPDGYHUVHHႇHFWVHYHQLI sprayed directly with water from any direction Water-resistant type 6 Protected against water sprayed directly on the unit from any direction Immersionprotected type 7 Water does not get inside of the unit when submerged in water according WRWKHVSHFL¿HGFRQGLWLRQV Underwater type 8 Unit can be used underwater Note: Details of test conditions are the same as NECA C 0920. Please refer to them. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 18 ー Panasonic Industry Co., Ltd. 2022 AECTB35E 202204 Technical Terminology & Cautions for Use (Detection Switches) TECHNICAL TERMINOLOGY Detection Switches Contact form A compact switch equipped with an enclosed micro-gap snapaction FRQWDFWPHFKDQLVPWKDWPDNHVDVSHFL¿HGPRWLRQZLWKDVSHFL¿HG force to open/close a circuit, and an actuator outside the enclosure (hereinafter referred to as the switch) 7KLVUHIHUVWRWKHFRPSRQHQWVGHWHUPLQLQJWKHW\SHRIDSSOLFDWLRQ which make up the electrical input/output circuits in the contact. Actuator A part of the switch that transmits the received external force to an internal spring mechanism to move the movable contact so that the switch can be opened and closed SPDT SPST-N.C. SPST-N.O. Actuator stopper Insulation resistance A part of the switch to limit the actuator movement in the switch operation direction Resistance between non-continuous terminals, each terminal and other exposed metal parts and between each terminal and ground. Rated values Values indicating the characteristics and performance guarantee standards of the snap-action switches. The rated current and rated YROWDJHIRULQVWDQFHDVVXPHVSHFL¿FFRQGLWLRQV W\SHRIORDG FXUUHQWYROWDJHIUHTXHQF\HWF  Dielectric Mechanical life Contact resistance 7KHVHUYLFHOLIHZKHQRSHUDWHGDWDSUHVHWRSHUDWLQJIUHTXHQF\ ZLWKRXWSDVVLQJHOHFWULFLW\WKURXJKWKHFRQWDFWV 7KHOLIHWHVWLV SHUIRUPHGDWDVZLWFKLQJIUHTXHQF\RIWLPHVPLQXWHDQG RSHUDWLQJVSHHGRIPPVHFRQGDWWKHUHJXODUFDP This indicates the electrical resistance at the contact part. *HQHUDOO\WKLVUHVLVWDQFHLQFOXGHVWKHFRQGXFWRUUHVLVWDQFHRIWKH spring and terminal portions. Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. Vibration resistance Electrical life The service life when the rated load is connected to the contact and switching operations are performed. (The life test is performed at a VZLWFKLQJIUHTXHQF\RIWLPHVPLQXWHDQGRSHUDWLQJVSHHGRI mm/second at the regular cam.) Malfunction vibration ... Vibration range where a closed contact does QRWRSHQIRUORQJHUWKDQDVSHFL¿HGWLPHGXHWRYLEUDWLRQVGXULQJ use of the snap-action switches. Shock resistance 6KRFNGXUDELOLW\6KRFNUDQJHZKHUHWKHPHFKDQLFDOVKRFNV received during snap-action switches transport and installation do not damage the parts or harm the operating characteristics. Malfunction shock ... Shock range where a closed contact does not RSHQIRUORQJHUWKDQDVSHFL¿HGWLPHGXHWRVKRFNVGXULQJXVHRI the snap-action switches. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 19 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) TECHNICAL TERMINOLOGY ■ 'H¿QLWLRQRIRSHUDWLQJFKDUDFWHULVWLF &ODVVL¿FDWLRQ The main terminological illustrations and meanings which are used with snapaction switches are as follows. Unit 9DU\LQJ GLVSOD\ method Operating Force OF N Max. The force required to cause contact snap-action. It is expressed terms of force applied to the the actuator. Release Force RF N Min. The force to be applied to the the actuator at the moment contact snaps back from operated position to total travel position. Totaltravel Force TF N Pretravel PT mm, degree Max. Distance or agree of the actuator movement from free position to operating position. Overtravel OT mm, degree Min. The distance or degree which the actuator is permitted to travel after actuation without DQ\GDPDJHWRWKHVZLWFKLQJPHFKDQLVP Movement 'LႇHUHQWLDO MD mm, degree Max. The distance or degree from operating position to release position of the actuator. Totaltravel TT mm, degree The migration length or the move angle from the free position to total travel position of actuator Free Position FP mm, degree Position of the actuator when no force is applied to. Operating Position OP mm, degree Release Position RP mm, degree The position of the actuator when the traveling contact snaps back from operating position to its original position. Total travel Position TTP mm, degree The stopping position of the actuator after total travel. RF OF PT Force TF TT FP 6\PERO 7HUPLQRORJ\ OT OP MD RP Force applied to an actuator required to move from an operating position to a total travel position TTP Movement Center of mounting holes Starting current Position ± The position of the actuator when the WUDYHOLQJFRQWDFWVVQDSVZLWKWKH¿[HG contact. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 20 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) TECHNICAL NOTES ON MECHANICAL CHARACTERISTICS Actuation Force and Stroke Changes in Operating Characteristics $GHTXDWHVWURNHVHWWLQJLVWKHNH\WRKLJKUHOLDELOLW\,WLVDOVR important that adequate contact force be ’maintained to ensure high UHOLDELOLW\)RUDQRUPDOO\FORVHG 1& FLUFXLWWKHGULYLQJPHFKDQLVP VKRXOGEHVHWVRWKDWWKHDFWXDWRULVQRUPDOO\LQWKHIUHHSRVLWLRQ )RUDQRUPDOO\RSHQ 12 FLUFXLWWKHDFWXDWRUVKRXOGEHSUHVVHGWR WRRIWKHVSHFL¿HGVWURNHWRDEVRUESRVVLEOHHUURUV ,IWKHVWURNHLVVHWWRRFORVHWRWKHRSHUDWLQJSRLQW 23 WKLVPD\ FDXVHXQVWDEOHFRQWDFWDQGLQWKHZRUVWFDVHPD\FDXVHDFWXDWRU damage due to inertia of the drive mechanism. It is advisable that the stroke be adjusted with the mounting plate or driving mechanism. Exercise design care so that malfunctions will not occur if the RSHUDWLQJFKDUDFWHULVWLFVYDU\E\DVPXFKDVIURPUDWHG values. ,QWKH2)0D[1VSHFL¿FDWLRQIRU)6VQDSDFWLRQVZLWFKHV WKHDOORZDEOH0D[LV1   1 ,QWKH5)0LQ10LQVSHFL¿FDWLRQ WKHDOORZDEOH0LQ1 ±  1 Mechanical Conditions for Type Selection $FWXDWRUW\SHVKRXOGEHVHOHFWHGDFFRUGLQJWRDFWLYDWLRQPHWKRG DFWLYDWLRQVSHHGDFWLYDWLRQUDWHDQGDFWLYDWLRQIUHTXHQF\  $QH[WUHPHO\VORZDFWLYDWLRQVSHHGPD\FDXVHXQVWDEOHFRQWDFW WUDQVIHUSRVVLEO\UHVXOWLQJLQFRQWDFWIDLOXUHVRUFRQWDFWIXVLRQ  $QH[WUHPHO\KLJKDFWLYDWLRQVSHHGPD\FDXVHGDPDJHWR contacts or contact response failure. Contact force Operating force 7KH¿JXUHDWULJKWVKRZVDW\SLFDOH[DPSOHRIDFWLYDWLRQ DQGFRQWDFWIRUFHVYDU\LQJZLWKVWURNH ,QWKHYLFLQLW\RIWKH23DQG53WKHFRQWDFWIRUFHLVGLPLQLVKHG FDXVLQJFKDWWHUDQGFRQWDFWERXQFHLPPHGLDWHO\EHIRUHRUDIWHU reversal. For this reason, use the switch while giving due consideration to this. This also causes the snap action switch to be sensitive to vibration or shock. Driving Mechanism 8VHRIDGULYLQJPHFKDQLVPZKLFKZLOOFDXVHSK\VLFDOLPSDFWWRWKH actuator should be avoided. OF <Example> RF RP FP OP MD PT TTP Stroke Bad OT Good N.C. On FP On reversal Stroke On reversal On OTP N.O. TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1) The snap-action switch is designed for AC operations. While it has VPDOOFRQWDFWJDSVDQGQRDUFDEVRUEHULWPD\EHXVHGIRUORZ FDSDFLW\'&RSHUDWLRQV Please refer to the rating of each products  )RUDSSOLFDWLRQVZLWKYHU\VPDOOVZLWFKLQJYROWDJHRUFXUUHQWFKRRVH WKHORZOHYHOORDGW\SH $XFRQWDFW  Small current and voltage application range (Au contact) Current (mA) 500 100 50 10 5 2 1 4 8 12 16 20 DC voltage (VDC) 24  :KHQVHOHFWLQJDFRQWDFWW\SHRIDVQDSDFWLRQVZLWFKWREHXVHG for low-level load switching, the following should be noted. 6LOYHUFRQWDFWV¶VXUIDFHVDUHSURQHWREHR[LGL]HGDQGIRUPDVXO¿GH ¿OP7KHVZLWFKRSHUDWHVZLWKQRSUREOHPVDWWKHEHJLQQLQJRIXVH +RZHYHUDVWKHFRQWDFWVXUIDFHVGHYHORS¿OPVZLWKWLPHWKH¿OP PD\QRWEHEURNHQE\WKHVZLWFKLQJRSHUDWLRQFDXVLQJDFRQGXFWLRQ IDLOXUH7KHUHIRUHSOHDVHFKRRVHWKH$XFRQWDFWW\SHIRUVZLWFKLQJD ORDGRI$RUEHORZ 4) Application to Electronic Circuits • The snap-action switch contacts can sustain bounce or chatter when closed. Bounce or chatter can cause noise or pulse count errors when the snap action switch is used in electronic circuits. ‡,IFRQWDFWERXQFHRUFKDWWHUSRVHVSUREOHPVLQWKHYLFLQLW\RIWKH OP and RP, use a suitable absorption network, such as a C/ R network.  &KHFNWKHVXUJHFXUUHQWQRUPDOFXUUHQWDQGVXUJHGXUDWLRQ  &RQWDFWUHVLVWDQFHJLYHQLQSHUIRUPDQFHVSHFL¿FDWLRQVLVPHDVXUHG ZLWKDYROWDJHGURSPHWKRGXVLQJWR9'&$ H[FHSWIRU ORZOHYHOORDGW\SH &RQWDFWUHVLVWDQFHDFURVV&20DQG1& terminals is measured in the free position, while contact resistance across COM and N.O. terminals is measured in the total travel position. 7) To prevent contact welding failure, be sure to use a serial resistance for each capacitive load.  ,IVQDSDFWLRQVZLWFKRSHUDWLRQLVV\QFKURQL]HGZLWKWKH$&VXSSO\ SKDVHWKLVPD\FDXVHVKRUWHQHGHOHFWULFDOOLIHFRQWDFWIXVLRQ IDLOXUHFRQWDFWWUDQVIHURURWKHUUHOLDELOLW\SUREOHPV Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 21 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) CAUTIONS IN A CIRCUIT 1) Contact protection is recommended when snap-action switches are used in an inductive load circuit. Circuit diagram Cautions for use Contact for snap-action switch r c R  'RQRWFRQQHFWWKHFRQWDFWVRQLQGLYLGXDOVZLWFKHVWRGLႇHUHQWW\SH RUGLႇHUHQWSROHVRIWKHSRZHUVXSSO\ ([DPSOHVRISRZHUVXSSO\FRQQHFWLRQV FRQQHFWLRQWRGLႇHUHQW poles) Wrong (1 U PRUHWKDQȍ () In an AC circuit ,PSHGDQFHRI5LVWREHVOLJKWO\ smaller than impedance of r and c. Lamp load PL Solenoid load Contact for snap-action switch r R c Can be used for both AC and DC. ,PSHGDQFHRIULVQHDUO\HTXDOWR impedance of R. &.1ȝ) Right Lamp load PL Solenoid load Load connected to same pole Contact for snap-action switch diode (1 )RU'&FLUFXLWVRQO\ ([DPSOHRIZURQJSRZHUVXSSO\FRQQHFWLRQ FRQQHFWLRQWRGLႇHUHQW SROHVRISRZHUVXSSO\ 7KLVPD\OHDGWRPL[HG'&DQG$& R Contact for snap-action switch Induction load Wrong ZNR Varistor Load Can be used for both AC and DC. L AC DC Load L  $YRLGFLUFXLWVZKLFKDSSO\YROWDJHEHWZHHQFRQWDFWV 7KLVPD\OHDG to mixed deposition.) Wrong 200 V L 100 V Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 22 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) MOUNTING STATE AND ENVIRONMENT Checking the insulation distance Soldering precautions After mounting and wiring, check the insulation distance between terminals and the ground. If the insulation distance is inadequate, mount insulating material between as required. )RUPDQXDOVROGHULQJOD\WKHWHUPLQDOVÀDW KRUL]RQWDOZLWKWKH JURXQG DQGTXLFNO\SHUIRUPWKHVROGHULQJRSHUDWLRQXVLQJD VROGHULQJLURQZLWKWKHDSSURSULDWHKHDWFDSDFLW\DQGWKHSURSHU DPRXQWRIVROGHU7DNHFDUHWKDWWKHÀX[GRHVQRWÀRZLQWRWKH VZLWFKLQWHULRUE\XVLQJDYHQWLODWLRQIDQWRGLVFKDUJHÀX[JDVDQGWR SUHYHQWFRQWDFWRIWKHVZLWFKERG\ZLWKWKHVROGHULQJLURQWLS %HFDUHIXOQRWWRDSSO\IRUFHWRWKHOHDGZLUHVRUWKHWHUPLQDO SRUWLRQVLPPHGLDWHO\DIWHUVROGHULQJ 7KHWHPSHUDWXUHVHWWLQJDQGWLPHFRQGLWLRQVYDU\GHSHQGLQJRQWKH product. See the section “CAUTIONS FOR USE” for each product. Fastening the snap-action switch body See the Section “CAUTIONS FOR USE” for the individual switch. 3RVLWLRQDGMXVWPHQWZLWKHႇHFWRU  7KHHႇHFWRUVKRXOGEHSRVLWLRQHGVRWKDWGLUHFWIRUFHLVQRWDSSOLHG to the plunger or actuator in its free position. The operating force to WKHSOXQJHUVKRXOGRQO\EHDSSOLHGLQDSHUSHQGLFXODUGLUHFWLRQ  1RWHWKDWWKHXVHRIWKHVZLWFKDVDVWRSSHUPD\FDXVHDQ operational problem. <Examples> Soldering iron tip Switch installation position %DVLFDOO\WKHVZLWFKVKRXOGEHLQVWDOOHGVRWKDWWKHREMHFWWRpress WKHVZLWFK¶VSOXQJHURUOHYHUFDQSUHVVLWGRZQWRWRRI27 of the switch. When determining the position, the tolerance of OP (Operating Position) and other factors should be taken into account. The following describes the case where the strictest tolerance conditions are adopted. ([DPSOH+LQJHOHYHUW\SH)6VZLWFK 5HIHUHQFHYDOXHV23 “PP 37 0D[PP 27 0LQPP Wrong Avoid using in a silicon atmosphere Avoid using organic silicon rubber, adhesives, sealing compounds, oil, grease, and wires in a silicon atmosphere. Please consult us when using under the following conditions*: FP OP TTP Correct PT  (QYLURQPHQWVZKHUHK\GURJHQVXO¿GHRURWKHUFRUURVLYHJDVHVDUH present.  (QYLURQPHQWVZKHUHJDVROLQHWKLQQHURURWKHUÀDPPDEOHH[SORVLYH gases are present.  'XVW\HQYLURQPHQWV IRUQRQVHDOW\SHVQDSDFWLRQVZLWFKHV  4) The perpendicular operating speed exceeds the allowable operating speed.  6ZLWFKLQJEHWZHHQGLႇHUHQWSROHV  8VHLQHQYLURQPHQWVQRWLQWKHSUHVFULEHGWHPSHUDWXUHRUKXPLGLW\ range. OT (1) When the switch is not pressed The object to press the lever should not be in contact with the lever. For this purpose, the object should be at a distance from the switch father than the maximum FP (Free Position) value. )30D[ 230D[370D[  PP0D[ 7KHREMHFWVKRXOGEHDWDGLVWDQFHRIPPRUPRUH from the mounting hole.  'HSUHVVHGSRVLWLRQ 7KHSOXQJHUOHYHUVKRXOGEHSUHVVHGGRZQWRRUPRUHRI OT (Over Travel). Therefore, the depressed position should be calculated based on the minimum value of OP (Operating 3RVLWLRQ DQGWKHDQGRIWKH27YDOXH 230LQRI27  PP 230LQRI27  PP The plunger/lever should be pressed down to the position of WRPPIURPWKHPRXQWLQJKROH Storage precautions To prevent discoloration due to sulfurization of the terminals (silverSODWHG VWRUHWKHVZLWFKHVLQDSRO\HWK\OHQHEDJRURWKHUVXLWDEOH airtight container. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 23 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) Usage, storage, and transport conditions (except turquoise switches) During usage, storage, or transportation, avoid locations subject to GLUHFWVXQOLJKWDQGPDLQWDLQQRUPDOWHPSHUDWXUHKXPLGLW\DQG pressure conditions. 7KHDOORZDEOHVSHFL¿FDWLRQVIRUHQYLURQPHQWVVXLWDEOHIRUXVDJH storage, and transportation are given below.  7HPSHUDWXUH7KHDOORZDEOHWHPSHUDWXUHUDQJHGLႇHUVIRUHDFK VZLWFKVRUHIHUWRWKHVZLWFK¶VLQGLYLGXDOVSHFL¿FDWLRQV,Q DGGLWLRQZKHQWUDQVSRUWLQJRUVWRULQJVZLWFKHVZKLOHWKH\DUH WXEHSDFNDJHGWKHUHDUHFDVHVZKHQWKHWHPSHUDWXUHPD\GLႇHU from the allowable range. In this situation, be sure to consult the LQGLYLGXDOVSHFL¿FDWLRQV  +XPLGLW\7KHDOORZDEOHWHPSHUDWXUHUDQJHGLႇHUVIRUHDFK VZLWFKVRUHIHUWRWKHVZLWFK¶VLQGLYLGXDOVSHFL¿FDWLRQV  3UHVVXUHWRN3D 7KHKXPLGLW\UDQJHYDULHVZLWKWKHWHPSHUDWXUH8VHZLWKLQWKH range indicated in the graph below. Humidity (% RH) 85 Allowable range Avoid icing when used at temperatures lower than 0°C Avoid condensation when used at temperatures higher than 0°C We reserve the right to modify without notice the materials, internal components, and other parts to improve product quality. Handling precautions :KHQKDQGOLQJWKHVZLWFKHVEHFDUHIXOQRWWRGURSWKHPRQWKHÀRRU VLQFHWKLVPD\GDPDJHWKHP * Select contact sulfurization (clipping) prevention products (FS and Au-clad double OD\HUFRQWDFWV IRUXVHZLWKH[WUHPHO\VPDOOORDGVRUDQHQYLURQPHQWUHVLVWDQW Turquoise switch. Others 1) Failure modes of switches include short-circuiting, opencircuiting and temperature rises. If this switch is to be used in equipment ZKHUHVDIHW\LVDSULPHFRQVLGHUDWLRQH[DPLQHWKHSRVVLEOH HႇHFWVRIWKHVHIDLOXUHVRQWKHHTXLSPHQWFRQFHUQHGDQGHQVXUH VDIHW\E\SURYLGLQJSURWHFWLRQFLUFXLWVRUSURWHFWLRQGHYLFHV,Q WHUPVRIWKHV\VWHPVLQYROYHGPDNHSURYLVLRQIRUUHGXQGDQF\LQ WKHGHVLJQDQGWDNHVWHSVWRDFKLHYHVDIHW\GHVLJQ  7KHDPELHQWRSHUDWLQJWHPSHUDWXUH DQGKXPLGLW\ UDQJHTXRWHG is the range in which the switch can be operated on a continuous EDVLVLWGRHVQRWPHDQWKDWXVLQJWKHVZLWFKZLWKLQWKHUDWLQJ JXDUDQWHHVWKHGXUDELOLW\SHUIRUPDQFHDQGHQYLURQPHQW withstanding performance of the switch. For details on the SHUIRUPDQFHJXDUDQWHHFKHFNWKHVSHFL¿FDWLRQVRIHDFKSURGXFW concerned. 5 -40 0 85 Ambient temperature (℃) (The allowable temperature depends on the switch.) Condensation will occur inside the switch if there is a sudden change in ambient temperature when used in an atmosphere of KLJKWHPSHUDWXUHDQGKLJKKXPLGLW\7KLVLVSDUWLFXODUO\OLNHO\WR KDSSHQZKHQEHLQJWUDQVSRUWHGE\VKLSVRSOHDVHEHFDUHIXORI the atmosphere when shipping. Condensation is the phenomenon ZKHUHE\VWHDPFRQGHQVHVWRFDXVHZDWHUGURSOHWVWKDWDGKHUHWR WKHVZLWFKZKHQDQDWPRVSKHUHRIKLJKWHPSHUDWXUHDQGKXPLGLW\ UDSLGO\FKDQJHVIURPDKLJKWRORZWHPSHUDWXUHRUZKHQWKH VZLWFKLVTXLFNO\PRYHGIURPDORZKXPLGLW\ORFDWLRQWRRQHRIKLJK WHPSHUDWXUHDQGKXPLGLW\ Please be careful because condensation can cause adverse FRQGLWLRQVVXFKDVGHWHULRUDWLRQRILQVXODWLRQFRLOFXWRႇDQGUXVW &RQGHQVDWLRQRURWKHUPRLVWXUHPD\IUHH]HRQWKHVZLWFKZKHQthe WHPSHUDWXUHVLVORZHUWKDQƒ&ƒ)7KLVFDXVHVSUREOHPVVXFKDV sticking of movable parts or operational time lags. The plastic becomes brittle if the switch is exposed to a low WHPSHUDWXUHORZKXPLGLW\HQYLURQPHQWIRUORQJSHULRGVRIWLPH Storage for extended periods of time (including transportation SHULRGV DWKLJKWHPSHUDWXUHVRUKLJKKXPLGLW\OHYHOVRULQ DWPRVSKHUHVZLWKRUJDQLFJDVHVRUVXO¿GHJDVHVPD\FDXVHD VXO¿GH¿OPRUR[LGH¿OPWRIRUPRQWKHVXUIDFHVRIWKHFRQWDFWVDQG RULWPD\LQWHUIHUHZLWKWKHIXQFWLRQV&KHFNRXWWKHDWPRVSKHUHLQ which the units are to be stored and transported. ,QWHUPVRIWKHSDFNLQJIRUPDWXVHGPDNHHYHU\HႇRUWWRNHHSthe HႇHFWVRIPRLVWXUHRUJDQLFJDVHVDQGVXO¿GHJDVHVWRWKHDEVROXWH minimum. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 24 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 Technical Terminology & Cautions for Use (Detection Switches) Shape Pretravel (PT) Overtravel (OT) Operating Force (OF) Vibration Shock Features Pin plunger Small Small Large Outstanding $SSURSULDWHIRUOLQHDUVKRUWVWURNHDFWLRQ3LQSOXQJHUDFWVGLUHFWO\ on snap action mechanism, enabling high-precision positioning. Amount of movement after operation is smallest among all of the actuators, however, so reliable stopper is required. Hinge lever Large Medium Small Possible Little force required for operation. Appropriate for use with low-speed cams and dogs; has large stroke. /HYHUDYDLODEOHLQYDULRXVVKDSHVWR¿WRSHUDWLQJXQLW Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi-circle, enabling use as a VLPSOHUROOHUW\SH Leaf lever Large Large Small Excellent 3OD\LQOHYHULVXVHGWRDVVXUHPD[LPXPVWURNH&RQVWUXFWLRQ provides for space where lever is attached, for outstanding resistance to freezing. Hinge roller lever Large Medium Small Possible This is a hinge lever with a roller, and can be used with highspeed cams and dogs. The force required for pin plunger action is lighter than that of the lever, and the stroke is longer. &ODVVL¿FDWLRQ Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 25 ー Panasonic Industry Co., Ltd. 2022 AECTB36E 202204 ■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ©Panasonic Industry Co., Ltd. 2023 Specifications are subject to change without notice. モユヤヵャビユチチチビパビピパヒ 2023.1
ABS1114509 价格&库存

很抱歉,暂时无法提供与“ABS1114509”相匹配的价格&库存,您可以联系我们找货

免费人工找货