CV (ACV)
AUTOMOTIVE
LOW PROFILE
MICRO-ISO RELAY
Micro ISO
1 Form C type
Micro ISO
1 Form A type
RoHS compliant
CV RELAYS (ACV)
FEATURES
TYPICAL APPLICATIONS
• Low profile:
22.5 mm(L)×15 mm(W)×15.7 mm(H)
.886 inch(L)×.591 inch(W)×.618 inch(H)
• Low temperature rise
Terminal temperature has been reduced
compared with using our conventional
product
• Low sound pressure level
Noise level has been reduced
approx.10dB compared with using our
conventional product.
• Wide line-up
Micro ISO terminal types and resistor
inside type.
• Plastic sealed type
Plastically sealed for automatic cleaning.
• Compact and high-capacity 20A load
switching
N.O.: 20A 14V DC, N.C.: 10A 14V DC
(Max. carrying current: at 85°C 185°F)
• Headlights
• Magnetic clutches
• Radiator fans
• Blowers
• Fog lamps
• Tail lights
• Heaters
• Defoggers
• Horns
• Condenser fans, etc.
ORDERING INFORMATION
ACV
Contact arrangement
1: 1 Form C
3: 1 Form A
Mounting classification
1: Micro ISO plug-in type
Protective element
0: None (Standard type)
2: With resistor inside
Coil voltage, DC
12: 12 V
TYPES
Contact arrangement
1 Form A
1 Form C
Coil voltage
Protective construction
12 V DC
Sealed type
Mounting classification
Micro ISO plug-in type
Micro ISO plug-in type
Part No.
ACV31012
ACV11012
Note: Please use “ACV∗∗212” to order built-in resistor type. (Asterisks “ ∗ ” should be filled in from ORDERING INFORMATION.)
Standard packing; Carton: 50 pcs.; Case: 200 pcs.
RATING
1. Coil data
Nominal coil
voltage
Pick-up voltage*
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Usable voltage range
(at 85°C 185°F)
12V DC
Max. 7.0 V DC
(Initial)
Min. 0.6 V DC
(Initial)
67 mA,
84 mA (with resistor)
180Ω,
142.3Ω (with resistor)
0.8 W,
1.0 W (with resistor)
10 to 16V DC
Note: * Other pick-up voltage types are also available. Please contact us for details.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB230E 201203-T1
CV (ACV)
2. Specifications
Characteristics
Item
Arrangement
Contact resistance (Initial)
Contact
Specifications
1 Form A
1 Form C
Typ 3mΩ (By voltage drop 6V DC 1A)
N.O.: Max. 0.2 V (By voltage drop 14 V DC 20 A)
N.O.: Max. 0.2 V (By voltage drop 14 V DC 20 A)
N.C.: Max. 0.5 V (By voltage drop 14 V DC 10 A)
Ag alloy (Cadmium free)
N.O.: 20 A 14V DC
N.O.: 20 A 14V DC, N.C.: 10 A 14V DC
Contact voltage drop (after electrical life test)
Contact material
Nominal switching capacity (resistive load)
Max. carrying current
(at 85°C 185°F, continuous)
Rating
N.O.: 20 A 14V DC
N.C.: 10 A 14V DC
0.8 W, 1.0 W (built-in resistor type)
1 A 12V DC
Min. 20 MΩ (at 500V DC)
N.O.: 20 A 14V DC
Nominal operating power
Min. switching capacity (resistive load)*1
Insulation resistance (Initial)
Between open contacts
Between contacts and coil
Operate time (at nominal voltage)
(at 20°C 68°F)
Release time (at nominal voltage)
(at 20°C 68°F)
500 Vrms for 1 min. (Detection current: 10mA)
500 Vrms for 1 min. (Detection current: 10mA)
Breakdown
voltage (Initial)
Electrical
characteristics
Mechanical
characteristics
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
Expected life
Mechanical
Electrical (at nominal switching capacity)
Conditions
Conditions for operation, transport and
storage*2
Max. 10ms (excluding contact bounce time) (Initial)
Max. 10ms (excluding contact bounce time) (Initial)
Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms)
10 Hz to 100 Hz, Min. 44.1 m/s2 {4.5G} (Detection time: 10µs)
10 Hz to 500 Hz, Min. 44.1 m/s2 {4.5G}, Time of vibration for each direction; X, Y, Z direction: 4 hours
Min. 106 (at 120 cpm)
5
Min. 10 (operating frequency: 2s ON, 2s OFF)
Ambient temperature: –40°C to +85°C –40°F to +185°F*3,
Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature),
air pressure: 86 to 106kPa
Approx. 15 g .53 oz
Mass
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Please refer to “Usage ambient
condition” in CAUTIONS FOR USE OF AUTOMOTIVE RELAYS.
*3. Please inquire if you will be using the relay in a high temperature atmosphere.
* Regarding solder, this product is not MIL (Military Standard) compliant. Please evaluate solder mounting by the actual equipment before using.
REFERENCE DATA
1. Coil temperature rise (20A)
2. Distribution of pick-up and drop-out voltage
3. Distribution of operate and release time
Point measured: Inside the coil
Contact carrying current: 20A
Coil applied voltage: 13.5V
Sample: ACV11012, 100pcs
Sample: ACV11012, 100pcs.
60
150
Pick-up voltage
Drop-out voltage
90
Operate time
Release time
80
120
90
50
Quantity, n
20A
Quantity, n
Temperature rise, °C
100
70
180
40
30
60
70
60
50
40
30
20
20
30
10
0
0
55
65
75
85
Ambient temperature, °C
10
0 1 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5
Voltage, V
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0
Operate and release time, ms
4. Ambient temperature and operating voltage
range
Coil applied voltage, VDC
30
25
20
Operation range
15
10
5
0
–40 –20
Pick-up voltage
(Cold start)
0
20 40 60 80 85 100 120
Ambient temperature, °C
ASCTB230E 201203-T1
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
CV (ACV)
5-(1). Electrical life test (Resistive load)
Change of pick-up and drop-out voltage
Sample: ACV11012, 3pcs.
Load: Resistive load (NC switching) 10A
Switching frequency: ON 1s, OFF 1s
Ambient temperature: Room temperature
Change of contact resistance
30
Circuit
13.5VDC
Pick-up voltage
6
Max.
X
Min.
5
4
3
Drop-out voltage
Max.
X
Min.
2
Contact resistance, mΩ
Pick-up and drop-out voltage, V
7
20
15
Max.
10
X
Min.
5
1
0
25
0
5
No. of operations, × 104
0
10
0
5
No. of operations, × 104
10
Load current waveform
Down: Load 5A
current
200ms
waveform
5-(2). Electrical life test (Lamp load)
Change of pick-up and drop-out voltage
Sample: ACV31212, 3pcs.
Load: 55Wx4, inrush: 90A/steady: 20A,
lamp actual load
Switching frequency: ON 1s, OFF 14s
Ambient temperature: Room temperature
30
Pick-up and drop-out voltage, V
7
Circuit
Pick-up voltage
6
5
55W
55W
55W
55W
Max.
X
Min.
4
3
Drop-out voltage
2
Max.
X
Min.
1
13.5VDC
Change of contact resistance
0
0
10
No. of operations, × 104
20
Contact resistance, mΩ
Up: Coil 10V
voltage
waveform 200ms
25
20
15
10
Max.
X
Min.
5
0
0
10
No. of operations, × 104
20
Load current waveform
Inrush current: 90A, steady current: 20A
Up: Coil 10V
voltage
waveform 200ms
Down: Load 20A
current
200ms
waveform
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB230E 201203-T1
CV (ACV)
5-(3). Electrical life test (Motor load)
Change of pick-up and drop-out voltage
Sample: ACV31212, 3pcs.
Load: inrush: 80A/steady: 18A,
radiator fan actual load (motor free)
Switching frequency: ON 2s, OFF 6s
Ambient temperature: Room temperature
Change of contact resistance
30
Circuit
M
Pick-up voltage
6
5
Max.
X
Min.
Contact resistance, mΩ
Pick-up and drop-out voltage, V
7
4
3
Drop-out voltage
2
M
Max.
X
Min.
1
25
20
15
10
Max.
X
Min.
5
13.5VDC
0
0
15
No. of operations, × 104
0
30
0
15
No. of operations, × 104
30
Load current waveform
Inrush current: 80A, steady current: 18A
Up: Coil 10V
voltage
waveform 500ms
Down: Load 20A
current
500ms
waveform
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. Micro ISO plug-in type
External dimensions
CAD Data
Schematic (Bottom view)
1 Form A
2
15.7
.618
5
1
11
.433
4.8
.189
0.8
.031
22.5
.886
6
8
.236 .315
*A
6.3
.248
15
.591
Including resistor type also available
0.8
.031
1 Form C
2
3.25
.128
9
.354
Sealed by epoxy resin
3
5
3
4
Dimension:
Max. 1mm .039 inch:
1 to 3mm .039 to .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
1
Including resistor type also available
Note: Intervals between terminals is measured at A surface level.
For Cautions for Use, see Relay Technical Information.
ASCTB230E 201203-T1
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/