ADW1105HLW

ADW1105HLW

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    RELAYGENPURPOSESPST16A5V

  • 数据手册
  • 价格&库存
ADW1105HLW 数据手册
1 Form A 8A/16A, Small Polarized Power Relays (latching type) New Low profile type (Inrush type) DW RELAYS (ADW1) FEATURES TYPICAL APPLICATIONS 1. Low profile type available (h = 15.8 mm .622 inch) 2. Inrush type available (TV-8 UL/C-UL approved) 3. IEC60335-1* compliant type available (PTI 325V VDE approved) 4. Reflow possible (pin-in-paste) 5. Certified by UL/C-UL, VDE 1. Lighting control equipment 2. Smart meters 3. Industrial equipment 4. Security equipment 5. Home appliances 6. Various power supplies * Common safety standard for major electrical appliance Reflow compatible type (Standard type) IEC60335-1 compliant type (Standard & Inrush type) RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION ADW 1 W Contact arrangement 1: 1 Form A Operating function 1: 1 coil latching type 2: 2 coil latching type Nominal coil voltage (DC) 03: 3V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V Contact capacity Nil: Standard type (8A) H: Inrush type (16A, Inrush current 100A) Type classification Nil: Reflow compatible type L: Low profile type T: IEC60335-1 compliant type Notes: 1. “L” and “T” type are non-compliant reflow soldering. 2. Low profile type is available (inrush type only). 3. The suffix “W” on the part number is only displayed on the inner and outer packaging. It is not displayed on the relay. –1– ASCTB8E 201603-T DW (ADW1) TYPES 1. Standard type (8A) (Reflow compatible type) Contact arrangement Nominal coil voltage 1 Form A 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC Part No. 1 coil latching type ADW1103W ADW1105W ADW1106W ADW1109W ADW1112W ADW1124W 2 coil latching type ADW1203W ADW1205W ADW1206W ADW1209W ADW1212W ADW1224W Standard packing: Carton: 100 pcs.; Case: 500 pcs. Note: Carton packing is standard. Tube packing type is also available. Please consult us for details. 2. Standard type (8A) (IEC60335-1 compliant type) Contact arrangement Nominal coil voltage 1 Form A 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC Part No. 1 coil latching type ADW1103TW ADW1105TW ADW1106TW ADW1109TW ADW1112TW ADW1124TW 2 coil latching type ADW1203TW ADW1205TW ADW1206TW ADW1209TW ADW1212TW ADW1224TW Standard packing: Carton: 100 pcs.; Case: 500 pcs. Note: Carton packing is standard. Tube packing type is also available. Please consult us for details. 3. Inrush type (16A, Inrush current 100A · IEC60335-1 compliant type)*1, *2 Contact arrangement Nominal coil voltage 1 Form A 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC Part No. 1 coil latching type ADW1103HTW ADW1105HTW ADW1106HTW ADW1109HTW ADW1112HTW ADW1124HTW 2 coil latching type ADW1203HTW ADW1205HTW ADW1206HTW ADW1209HTW ADW1212HTW ADW1224HTW Standard packing: 100 pcs.; Case: 500 pcs. Notes: *1. Carton packing is standard. Tube packing type is also available. Please contact us for details. *2. Please contact us for the reflow compatible type of inrush type (16A, Inrush current 100A · IEC60335-1 compliant type). 4. Inrush type (16A, Inrush current 100A · Low profile type) Contact arrangement Nominal coil voltage 1 Form A 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC Part No. 1 coil latching type ADW1103HLW ADW1105HLW ADW1106HLW ADW1109HLW ADW1112HLW ADW1124HLW 2 coil latching type ADW1203HLW ADW1205HLW ADW1206HLW ADW1209HLW ADW1212HLW ADW1224HLW Standard packing: 100 pcs.; Case: 500 pcs. –2– ASCTB8E 201603-T DW (ADW1) RATING 1. Coil data 1) 1 coil latching type Nominal coil voltage Set voltage (at 20°C 68°F) 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC *80%V or less of nominal voltage (Initial) Reset voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) *80%V or less of nominal voltage (Initial) 66.7mA 40.0mA 33.3mA 22.2mA 16.7mA 8.3mA 45Ω 125Ω 180Ω 405Ω 720Ω 2,880Ω 200mW 110%V of nominal voltage Reset voltage (at 20°C 68°F) Nominal operating current [±10%] (at 20°C 68°F) Set coil Reset coil Coil resistance [±10%] (at 20°C 68°F) Nominal operating power 2) 2 coil latching type Nominal coil voltage Set voltage (at 20°C 68°F) 3V DC 5V DC 6V DC 9V DC 12V DC 24V DC *80%V or less of nominal voltage (Initial) *80%V or less of nominal voltage (Initial) 133.3mA 80.0mA 66.7mA 44.4mA 33.3mA 16.7mA 133.3mA 80.0mA 66.7mA 44.4mA 33.3mA 16.7mA Set coil Reset coil Set coil Reset coil 22.5Ω 62.5Ω 90 Ω 202.5Ω 360 Ω 1,440 Ω 22.5Ω 62.5Ω 90 Ω 202.5Ω 360 Ω 1,440 Ω 400mW 400mW Max. applied voltage (at 20°C 68°F) 110%V of nominal voltage *Square, pulse drive 2. Specifications Characteristics Contact Rating Electrical characteristics Mechanical characteristics Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Breakdown voltage Between open contacts (Initial) Between contact and coil Surge breakdown voltage*2 (Between contact and coil) Set time (at 20°C 68°F) (Initial) Reset time (at 20°C 68°F) (Initial) Functional Shock resistance Destructive Functional Vibration resistance Destructive Mechanical Resistive load Expected life Electrical Inrush current Conditions Unit weight Conditions for operation, transport and storage*3 *4 Specifications Standard type Inrush type 1 Form A Max. 100 mΩ (By voltage drop 6 V DC 1A) AgSnO2 type 8A 250V AC 16A 277V AC 2,000VA 4,432VA 250V AC 277V AC 8A AC 16A AC 200mW (1 coil latching type), 400mW (2 coil latching type) 100mA 5 V DC Min. 1,000MΩ (at 500V DC, Measurement at same location as “Breakdown voltage” section) 1,000 Vrms for 1min. (Detection current: 10mA) 5,000 Vrms for 1min. (Detection current: 10mA) 12,000 V (Initial) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time) 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs) 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms) 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10μs) 10 to 55 Hz at double amplitude of 3 mm Min. 106 (at 180 times/min.) Min. 5 × 104 (at 8A 250V AC, at 20 times/min.) Min. 2 × 104 (at 16A 277V AC, ON:OFF = 1s:5s) Min. 105 (at 5A 250V AC, at 20 times/min.) Min. 5 × 104 (at 8A 250V AC, at 20 times/min.) (IEC60335-1 type only) Min. 2.5 × 104 [Inrush 100A 600W (120V AC) — Tungsten] Cycle rate ON:OFF = 1s:59s Temperature: –40°C to +85°C –40°F to +185°F (8A or less), Temperature: –40°C to +85°C –40°F to +185°F –40°C to +70°C –40°F to +158°F Humidity: 5 to 85% R.H. (Not freezing and (Over 8A to 16A) condensing at low temperature) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 8 g .28 oz (Low profile type: Approx. 7.5 g .26 oz) Notes: *1. Minimum switching load is a guide to the lower current limit of switching under the micro-load. This parameter is changed by the condition, such as switching times, environment condition, and expected reliability. Therefore, Panasonic Corporation cannot assure the reliability. When the relay is used lower than minimum switching load, reliability is attrition. Please use the relay over minimum switching load. *2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. Allowable range when in original packaging is –40°C to +70°C –40°F to +158°F. –3– ASCTB8E 201603-T DW (ADW1) REFERENCE DATA ■ Standard type and Inrush type ■ Standard type 1. Max. switching capacity (AC resistive load) 1. Set time (1 coil latching type) 2. Reset time (1 coil latching type) Tested sample: ADW1106, 15 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA 10 8 7.0 7.0 6.0 6.0 5.0 4.0 Max. 3.0 5.0 4.0 Max. 3.0 Min. Min. Standard type 1 1 Reset time, ms Inrush type Set time, ms Contact current, A 100 Tested sample: ADW1106, 15 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA 10 100 250 Contact voltage, V 2.0 2.0 1.0 1.0 0.0 70 1000 80 90 100 110 120 Coil applied voltage, %V 0.0 70 130 80 90 100 110 120 Coil applied voltage, %V 130 ■ Inrush type Tested sample: ADW1106, 6pcs Ambient temperature: –40°C to +85°C –40°F to +185°F 1. Set time (1 coil latching type) 20 Reset voltage Ave. Ave. 10 0 20 40 60 80 100 Set time, ms Change rate to nominal voltage, %V 30 Set voltage -10 7.0 6.0 6.0 5.0 4.0 3.0 Max. Min. 5.0 4.0 3.0 Max. Min. 2.0 2.0 1.0 1.0 -30 0.0 70 80 90 100 110 120 130 140 150 160 Coil applied voltage, %V 0.0 70 80 90 100 110 120 130 140 150 160 Coil applied voltage, %V 4. Reset time (2 coil latching type) Tested sample: ADW1212HL, 30 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA 5. Ambient temperature characteristics Tested sample: ADW1212HL, 30 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA 7.0 7.0 6.0 6.0 Reset time, ms Set time, ms 7.0 -20 3. Set time (2 coil latching type) 5.0 4.0 3.0 2.0 Tested sample: ADW1112HL, 30 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA Max. Min. Tested sample: ADW1105HL, 6pcs Ambient temperature: –40°C to +85°C –40°F to +185°F 30 Change rate to nominal voltage, %V Ambient temperature, °C -60 -40 -20 2. Reset time (1 coil latching type) Tested sample: ADW1112HL, 30 pcs Ambient temperature: 28°C 82.4°F Contact load: 5V DC, 10mA Reset time, ms 3. Ambient temperature characteristics 5.0 Ambient temperature, °C -60 -40 -20 4.0 20 Reset voltage 10 Set voltage 0 20 40 3.0 Max. Min. 2.0 60 80 100 -10 1.0 1.0 -20 0.0 70 80 90 100 110 120 130 140 150 160 Coil applied voltage, %V 0.0 70 80 90 100 110 120 130 140 150 160 Coil applied voltage, %V -30 –4– Ave. Ave. ASCTB8E 201603-T DW (ADW1) DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. Standard height type External dimensions CAD Data PC board pattern (Bottom view) 24.00 .945 17.50 .689 4 or 5-1.20 dia. hole 4 or 5-.047 dia. hole 3.50 .138 7.50 .295 2 coil latching type only 10.00 .394 Tolerance: ±0.1 ±.004 2 coil latching type only 0.70 .028 18.80 .740 Schematic (Bottom view) 1 coil latching type −1 2 coil latching type −1 3 3 +7 0.40 dia. .016 dia. 1.50 .059 0.80 .031 17.50 .689 0.80 .031 0.20 .008 3.20 .126 3.50 .138 0.27 .011 7.50 .295 +6 −6 5 (Reset condition) 5 (Reset condition) General tolerance: ±0.3 ±.012 2. Low profile type External dimensions CAD Data PC board pattern (Bottom view) 24.00 .945 17.50 .689 4 or 5-1.20 dia. hole 4 or 5-.047 dia. hole 3.50 .138 7.50 .295 2 coil latching type only 10.00 .394 Tolerance: ±0.1 ±.004 0.25 .010 Schematic (Bottom view) 15.80 +0.20 −0.30 .622 +.008 −.012 2 coil latching type only 1 coil latching type −1 0.40 dia. .016 dia. 1.50 .059 0.80 .031 17.50 .689 0.80 .031 3.50 .138 3.20 .126 7.50 .295 3 +7 +6 General tolerance: ±0.3 ±.012 −1 3 0.27 .011 0.20 .008 2 coil latching type 5 (Reset condition) −6 5 (Reset condition) SAFETY STANDARDS Item Standard type (8A) File No. E43149 E43149 Inrush type (16A) UL/C-UL (Recognized) Contact rating 8A 250V AC R 85°C 185°F 5×104 5A 30V DC R 85°C 185°F 5×104 16A 277V AC R 60°C 140°F 5×104 8A 250V AC R 85°C 185°F 5×104 5A 30V DC R 85°C 185°F 5×104 1200W Standard ballast 277V AC 50°C 122°F 6×103 1200W Tungsten, 240V AC 50°C 122°F 6×103 600W Tungsten, 120V AC 50°C 122°F 2.5×104 File No. 40032254 40032254 VDE (Recognized) TV rating (UL/C-UL) Contact rating File No. Contact rating 8A 250V AC (cosφ =1.0) 85°C 185°F 5×104 — — 5A 30V DC (0ms) 85°C 185°F 5×104 4 16A 277V AC (cosφ =1.0) 70°C 158°F 5×10 E43149 TV-8 rating 240V AC 8A 250V AC (cosφ =1.0) 85°C 185°F 5×104 40°C 104°F 2.5×104 5A 30V DC (0ms) 85°C 185°F 5×104 5A 347V AC R 85°C 185°F (UL standards only) 5×104 Notes: 1. CSA standards: Certified by C-UL 2. CQC standard: Application pending, Please contact us. –5– ASCTB8E 201603-T DW (ADW1) NOTES 1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES”. 2. Solder and cleaning conditions 1) Flow solder mounting conditions Please obey the following conditions when soldering automatically. (1) Preheating: within 120°C 248°F (solder surface terminal portion) and within 120 seconds (2) Soldering iron: 260°C±5°C 500°F±41°F (solder temperature) and within 6 seconds (soldering time) *Furthermore, because the type of PC board used and other factors may influence the relays, test that the relays function properly on the actual PC board on which they are mounted. 2) Reflow solder mounting (Pin-inPaste mounting) conditions 3. Max. applied voltage It is not allowed to apply the continuous maximum voltage to the coil. In order to obtain the specified performance, please apply nominal coil voltage. 4. Set/reset pulse time of latching type relay Regarding the set/reset pulse time of the latching type relay, it is recommended to apply nominal coil voltage for minimum 30ms pulse across the coil to secure the sure operation considering the ambient temperature and condition change through service life. T3 T2 T1 t1 t2 T1 = 150 to 180°C 302 to 356°F T2 = 230°C 446°F or more T3 = 250°C 482°F or less t 1 = 60 to 120 seconds t 2 = within 30 seconds • Cautions to observe when mounting temperature increases in the relay are greatly dependent on the way different parts are located a PC board and the heating method of the reflow device. Therefore, please conduct testing on the actual device beforehand after making sure the parts soldered on the relay terminals and the top of the relay case are within the temperature conditions given above. 3) Since this is not a sealed type relay, do not clean it as is. Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay. –6– ASCTB8E 201603-T DW (ADW1) –7– ASCTB8E 201603-T DW (ADW1) –8– ASCTB8E 201603-T
ADW1105HLW 价格&库存

很抱歉,暂时无法提供与“ADW1105HLW”相匹配的价格&库存,您可以联系我们找货

免费人工找货