MULTI-RANGE
ANALOG TIMER
S1DXM-A/M
RoHS compliance
Features
• Multiple functions built in
• Part No. consolidation
(The lineup consists of 64 easy-tochoose models.)
• Cadmium-free contacts used
• Economically priced
• Operation mode and time range
switches are on front panel.
(Operation mode switch on S1DXM-M
series only.)
Time selectable
Mode selectable
Product types
S1DXM-A multi-range timer
No MODE switch, Operation mode (fixed): Power ON-delay
Operating voltage
12V DC
24V DC
24V AC *Note
100 to 120V AC
200 to 220V AC
220 to 240V AC *Note
Time range
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
Timed-out 2 Form C
Part No.
S1DXM-A2C10M-DC12V
S1DXM-A2C30M-DC12V
S1DXM-A2C60M-DC12V
S1DXM-A2C10H-DC12V
S1DXM-A2C10M-DC24V
S1DXM-A2C30M-DC24V
S1DXM-A2C60M-DC24V
S1DXM-A2C10H-DC24V
S1DXM-A2C10M-AC24V
S1DXM-A2C30M-AC24V
S1DXM-A2C60M-AC24V
S1DXM-A2C10H-AC24V
S1DXM-A2C10M-AC120V
S1DXM-A2C30M-AC120V
S1DXM-A2C60M-AC120V
S1DXM-A2C10H-AC120V
S1DXM-A2C10M-AC220V
S1DXM-A2C30M-AC220V
S1DXM-A2C60M-AC220V
S1DXM-A2C10H-AC220V
S1DXM-A2C10M-AC240V
S1DXM-A2C30M-AC240V
S1DXM-A2C60M-AC240V
S1DXM-A2C10H-AC240V
Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details.
A socket line holding clip (ADX28005) is not included with the product. Please purchase separately.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Timed-out 4 Form C
Part No.
S1DXM-A4C10M-DC12V
S1DXM-A4C30M-DC12V
S1DXM-A4C60M-DC12V
S1DXM-A4C10H-DC12V
S1DXM-A4C10M-DC24V
S1DXM-A4C30M-DC24V
S1DXM-A4C60M-DC24V
S1DXM-A4C10H-DC24V
S1DXM-A4C10M-AC24V
S1DXM-A4C30M-AC24V
S1DXM-A4C60M-AC24V
S1DXM-A4C10H-AC24V
S1DXM-A4C10M-AC120V
S1DXM-A4C30M-AC120V
S1DXM-A4C60M-AC120V
S1DXM-A4C10H-AC120V
S1DXM-A4C10M-AC220V
S1DXM-A4C30M-AC220V
S1DXM-A4C60M-AC220V
S1DXM-A4C10H-AC220V
S1DXM-A4C10M-AC240V
S1DXM-A4C30M-AC240V
S1DXM-A4C60M-AC240V
S1DXM-A4C10H-AC240V
IP40
Timers
S1DXM-A/M
S1DXM-A/M
S1DXM-M multi-range timer
With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker OFF start, Power Flicker ON start, Power One-shot
Timers
Operating voltage
12V DC
24V DC
24V AC *Note
100 to 120V AC
200 to 220V AC
220 to 240V AC *Note
Time range
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
0.05 s to 10 min
0.2 s to 30 min
0.5 s to 60 min
0.05 min to 10 hr
Timed-out 2 Form C
Part No.
S1DXM-M2C10M-DC12V
S1DXM-M2C30M-DC12V
S1DXM-M2C60M-DC12V
S1DXM-M2C10H-DC12V
S1DXM-M2C10M-DC24V
S1DXM-M2C30M-DC24V
S1DXM-M2C60M-DC24V
S1DXM-M2C10H-DC24V
S1DXM-M2C10M-AC24V
S1DXM-M2C30M-AC24V
S1DXM-M2C60M-AC24V
S1DXM-M2C10H-AC24V
S1DXM-M2C10M-AC120V
S1DXM-M2C30M-AC120V
S1DXM-M2C60M-AC120V
S1DXM-M2C10H-AC120V
S1DXM-M2C10M-AC220V
S1DXM-M2C30M-AC220V
S1DXM-M2C60M-AC220V
S1DXM-M2C10H-AC220V
S1DXM-M2C10M-AC240V
S1DXM-M2C30M-AC240V
S1DXM-M2C60M-AC240V
S1DXM-M2C10H-AC240V
Timed-out 4 Form C
Part No.
S1DXM-M4C10M-DC12V
S1DXM-M4C30M-DC12V
S1DXM-M4C60M-DC12V
S1DXM-M4C10H-DC12V
S1DXM-M4C10M-DC24V
S1DXM-M4C30M-DC24V
S1DXM-M4C60M-DC24V
S1DXM-M4C10H-DC24V
S1DXM-M4C10M-AC24V
S1DXM-M4C30M-AC24V
S1DXM-M4C60M-AC24V
S1DXM-M4C10H-AC24V
S1DXM-M4C10M-AC120V
S1DXM-M4C30M-AC120V
S1DXM-M4C60M-AC120V
S1DXM-M4C10H-AC120V
S1DXM-M4C10M-AC220V
S1DXM-M4C30M-AC220V
S1DXM-M4C60M-AC220V
S1DXM-M4C10H-AC220V
S1DXM-M4C10M-AC240V
S1DXM-M4C30M-AC240V
S1DXM-M4C60M-AC240V
S1DXM-M4C10H-AC240V
Note: 48 V DC, 100 to 110 V DC, 24 V AC and 220 to 240 V AC types are made to order. Please inquire for details.
A socket line holding clip (ADX28005) is not included with the product. Please purchase separately.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
S1DXM-A/M
Specifications
Item
Rated operating voltage
Rated frequency
Rated power
consumption
Rating
Specifications
100 to 120VAC
200 to 220VAC
220 to 240VAC
12VDC
24VDC
50/60Hz common
—
Max. 3 VA
Max. 3 VA
Max. 3 VA
Max. 3 VA
Max. 2 W
Max. 2 W
(at 24 VAC)
(at 100 VAC)
(at 200 VAC)
(at 220 VAC)
(at 12 VDC)
(at 24 VDC)
Approx. 3mA
Approx. 3mA
Approx. 3mA
Approx. 3mA
Approx. 5mA
Approx. 3mA
Approx. 80mA
Approx. 20mA
Approx. 13mA
Approx. 13mA
Approx. 70mA
Approx. 40mA
Timed -out 2 Form C: 7A 250V AC (resistive load)
Timed -out 4 Form C: 5A 250V AC (resistive load)
S1DXM-A
Power on delay operation fixed
(Power display: ON/green; Operation display (when output is on): UP/orange)
S1DXM-M
4 switchable operations: Power ON-delay/Power Flicker OFF start/Power Flicker ON start/Power One-shot
(Power display: ON/green; Operation display (when output is on): UP/orange)
During time delay
After time delay
Rated control capacity
Operation mode
Time
accuracy*1
Contact
Life
Mechanical
Operating time fluctuation &
Power off time change error
Voltage error
Temperature error
Setting error
Contact arrangement
Contact resistance (Initial value)
Within ±1%, (power off time change at the range of 0.1 s to 1 h), 1 s range: Max. ±1% and 10 ms*2
Within ±1% (at the operating voltage changes between –20 to +10%), 1 s range: Max. ±1% and 10 ms*2
Within ±5% (at 20°C 68°F ambient temp. at the range of –10 to +50°C +14 to +122°F)
Within ±10%, 1 s range: Max. ±10% and 20 ms
Timed-out 2 Form C, Timed-out 4 Form C
Max. 100mΩ (at 1A, 6V DC)
Timed-out 2 Form C type: Silver alloy, Au plating
Contact material
Timed-out 4 Form C type: Silver alloy, Au plating
Mechanical (constant)
Min. 107
Electrical (constant)
2×105 (at rated control capacity)
Functional
10 to 55Hz: 1 cycle/min single amplitude of 0.25mm (10min on 3 axes)
Vibration
resistance
Destructive
10 to 55Hz: 1 cycle/min single amplitude of 0.375mm (1h on 3 axes)
Functional
Min. 98m/s2 (4 times on 3 axes)
Shock
resistance
Destructive
Min. 980m/s2 (5 times on 3 axes)
Allowable operating voltage range 19.2 to 26.4 V DC
80 to 132 V AC
160 to 242 V AC
176 to 264 V AC
9.6 to 13.2 V DC 19.2 to 26.4 V DC
Reset time
Max. 0.1s
Insulation resistance (Initial value)
Electrical
Breakdown voltage (Initial value)
Operating
conditions
Temperature rise
Ambient temperature
Ambient humidity
Air pressure
Ripple factor
Mass (Weight)
Protective construction
Between live and dead metal parts, between input and output, between contact sets, between contacts
Min. 100 MΩ (at 500 V DC megger)
Between live and dead metal parts: 2,000 Vrms for 1 min
Between input and output: 2,000 Vrms for 1 min
Between contact sets: 2,000 Vrms for 1 min
Between contacts: 1,000 Vrms for 1 min
Max. 70°C 158°F
–10 to 50°C +14 to 122°F
30 to 85% RH (non-condensing)
860 to 1060 hPa
DC type only, transmission wave rectification (ripple factor: approx. 48%)*3
Approx. 45 g
IEC standard: IP40 (IP50 when using ADX18008 protective cover)
Notes: *1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20°C 68°F, and power off time 1 second.
*2. Power one-shot 1 s range: +2% and 10 ms
*3. When using with a transmission wave rectification, vibration resistance and shock resistance properties worsen compared to when using a stabilized power supply.
Time range setting
Type
S1DXM-A
S1DXM-M
Time scale
10M type
30M type
60M type
10H type
10M type
30M type
60M type
10H type
X1
X10
X1
X10
Time unit
s
s
s
m
s
s
s
m
m
m
m
h
m
m
m
h
Min. scale
0.05
0.2
0.5
0.05
0.05
0.2
0.5
0.05
Max. scale
1
3
6
1
1
3
6
1
0.05 to 1s
0.2 to 3s
0.5 to 6s
0.05 to 1m
0.05 to 1s
0.2 to 3s
0.5 to 6s
0.05 to 1m
Note: The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h).
Example: When dial reads 1, time scale is X1 and time units is seconds, then it is 1 second.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Setting range
0.5 to 10s
0.05 to 1m
2 to 30s
0.2 to 3m
5 to 60s
0.5 to 6m
0.5 to 10m
0.05 to 1h
0.5 to 10s
0.05 to 1m
2 to 30s
0.2 to 3m
5 to 60s
0.5 to 6m
0.5 to 10m
0.05 to 1h
0.5 to 10m
2 to 30m
5 to 60m
0.5 to 10h
0.5 to 10m
2 to 30m
5 to 60m
0.5 to 10h
Timers
24VAC
S1DXM-A/M
Operation mode and Time range setting
Timers
Operation mode
Operation mode switch
Time range switch
ON
1
Power ON-delay
s
(m)
m
(h)
X1
X10
2
ON
1
The time setting can be switched among 4
ranges each for 4 types for an interval between
0.05 seconds and 10 hours.
Power Flicker OFF start
2
Notes: 1. The product is factory shipped with all settings on the OFF side (left).
2. Do not operate the switches with a sharp-edged object such as a knife
blade.
3. The power must be turned off when setting the time range or operation
mode. Operating the switches with the power on is a cause of breakdown
and malfunction.
4. Use a force of under 5 N to operate the DIP switches when setting the time
range and operation mode.
ON
1
Power Flicker ON start
2
ON
1
Power One-shot
2
Operation mode
S1DXM-A multi-range timer
Power ON-delay operation
• When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off.
Time chart
Power supply
Timed-out contact (NO)
ON
OFF
ON
T
OFF
T: Setting time
UP (operation) LED
(orange)
ON (power) LED
(green)
S1DXM-M multi-range timer
Power ON-delay operation
Power Flicker OFF start operation
[MODE] switch 1: OFF, switch 2: OFF
• When power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.
[MODE] switch 1: OFF, switch 2: ON
• When the power is turned on, the output contacts repeatedly operate at
the set time. The output contact begins from the off state.
Time chart
Time chart
Power supply
Timed-out contact (NO)
ON
Power supply
OFF
ON
T
Timed-out contact (NO)
OFF
T: Setting time
UP (operation) LED
ON
OFF
ON
T
T
OFF
ON (power) LED
T
T
t
t
很抱歉,暂时无法提供与“ADX18002”相匹配的价格&库存,您可以联系我们找货