0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
AFP7EXPC01

AFP7EXPC01

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    CABLEASSEMBLYEXTENSION3.28'

  • 数据手册
  • 价格&库存
AFP7EXPC01 数据手册
NEW Programmable Controller FP7 SERIES Conforming to EMC Directive FP7 series analog input unit with high-speed processing of multiple channels now added! High speed, easy collection and processing of analog signals Not only equipped for high-speed processing, the FP7 is also easy to operate and to configure. NEW Analog input unit high-speed and multi-channel type AFP7AD8 High-speed conversion 25 µs/channel Averaging processing Number of times, time, moving Digital processing Scale conversion setting / offset setting / gain setting Setting Software tool for easy operation High-speed sampling that doesn’t depend on CPU unit scanning. Sampling and data collection in the analog unit! Use the AFP7AD8 for measurement applications because with the fixed cycle, analog signal can be held in the buffer. Dependent on scan of CPU High-speed and high-accuracy type also available. The scan gets delayed when the CPU slows down due to other processes and sampling becomes sporadic. For details, please see the back cover. Occurrence of failure Sampling in the analog unit AFP7DA4H AFP7AD4H Accurate sampling possible with fixed cycle. Accurate sampling! Expansion unit capable of bus expansion and distributed installation Connect a maximum of 3 blocks and a total of 64 units Three blocks can be expanded on one CPU unit. Distributed installation achieved while maintaining high-speed bus transmission. Expansion master unit Total CPU unit 64 units Previous Maximum of 16 units for each unit ・・・・・・・・・ Expansion cable Max. 3 blocks NEW NEW End unit (included) Expansion master unit Expansion slave unit AFP7EXPM AFP7EXPS 2014.10 panasonic.net/id/pidsx/global Expansion slave units Max. 16 units ・・・・・・・・・ Max. 16 units ・・・・・・・・・ Max. 16 units ・・・・・・・・・ *If required, a power supply unit can be connected on the left side of the expansion unit. Pr o g r a mma b l e c o n tr o lle r FP7 SERIES SPECIFICATIONS Analog input unit (high-speed and multi-channel type) AFP7AD8 8 channels -10 to 10 V DC (resolution: 1/62,500) 0 to 10 V DC (resolution: 1/31,250) 0 to 5 V DC (resolution: 1/31,250) 1 to 5 V DC (resolution: 1/25,000) (Note) 0 to 20 mA (resolution: 1/31,250) 4 to 20 mA (resolution: 1/25,000) (Note) Part No. Number of channels Voltage Input range (resolution) Current Conversion speed Voltage / current Insulation method Rated input voltage / rated input current Input impedance Trigger input Operating voltage range Min. ON voltage / Min. ON current section Max. OFF voltage / Max. OFF current Response OFF→ON time ON→OFF Input points per common Current consumption Net weight 25 μs/channel ±0.1 % F.S. or less (at 25 °C 77 °F) ±0.3 % F.S. or less (at 0 to 55 °C 32 to 131 °F) Overall accuracy Input impedance Part No. Buffer function Voltage input / Current input 1 MΩ approx. / 250 Ω -15 to 15 V DC voltage input -2 to 30 mA current input Max. input range Between input terminals and internal circuit Between analog input and trigger input terminal Conversion execution / non-execution channel setting Input range change method Number of times Averaging Time duration Moving Digital processing Scale conversion setting Offset setting Gain setting Insulation method Photocoupler and isolated DC / DC converter Part No. Block Unit Distance between Transmission blocks distance Total extension Number of expansion Selectable per channel Setting range: 2 to 60,000 times Time setting range: 1 to 1,500 ms Setting range: 2 to 2,000 times Any value within ±30,000 Any value within ±3,000 Any value within 9,000 to 11,000 Possible to make settings on a channel-byMax. and min. value holding channel basis Possible to make settings on a channel-byComparison of upper and lower limit values channel basis (hysteresis) When less than 2.8 mA (only when current Broken wire detection input range 4 to 20 mA is set.) Analog device lineup Analog input and output units Product name FP7 analog input unit (high-speed and multi-channel type) FP7 analog input unit (high-speed and high-accuracy type) FP7 analog output unit (high-speed and high-accuracy type) 24 V DC / 12 mA approx. (at 24 V DC) 2 kΩ approx. 21.6 to 26.4 V DC 19.2 V / 3.5 mA 5 V / 1.5 mA 0.1 ms or less 0.1 ms or less 1 point/common 85 mA or less 130 g approx. Functions for the expansion unit Selectable per channel unit Note: The full scale (F.S.) on the accuracy of an analog voltage input range from +1 to +5 V and that of an analog current input range from +4 to +20 mA are 0 to +5 V and 0 to +20 mA, respectively. AFP7AD8 3 trigger types: Soft trigger, external trigger and input level Photocoupler Current consumption (Note 2) Max. allowable current Expansion bus connector Net weight Accessories AFP7EXPM AFP7EXPS Max. 3 blocks (total 4 blocks) Max. 48 units (total 64 units) Length of expansion cable (0.5 m 1.640 ft, 1 m 3.281 ft, 3 m 9.843 ft and 10 m 32.808 ft) Max. 30 m 98.425 ft (Expansion cable × 3 expansions) (Note 1) 120 mA or less 100 mA or less 3.0 A (at 24 V DC – power supply terminal) MIL 40 pins MIL 40 pins × 2 200 g approx. 120 g approx. (including end unit) Power supply cable (Part No.: AFPG805) – End unit (Part No.: AFP7END) Notes: 1) Can support a maximum of 100 m 328.084 ft length between blocks. Please inquire with us for details. 2) Differs depending on power supply voltage and number of expansion units. Specifications Number of channels Voltage / current, conversion rate: 25 μs/channel, resolution: max. 16 bits, accuracy: ±0.1 % F.S. or 8 channels less (at 25 °C 77 °F) Voltage / current, conversion rate: 25 μs/channel, resolution: max. 16 bits, accuracy: ±0.05 % F.S. or 4 channels less (at 25 °C 77 °F) / insulation between channels Voltage / current, conversion rate: 25 μs/channel, resolution: max. 16 bits, accuracy: ±0.1 % F.S. or 4 channels less (at 25 °C 77 °F) / insulation between channels Part No. AFP7AD8 AFP7AD4H AFP7DA4H Temperature input units Product name FP7 Thermocouple multiple analog input unit FP7 Resistance temperature detector input unit Specifications Number of channels Thermocouple (K, J, T, N, R, S, B, E, PLII and WRe5-26), Voltage / current, conversion rate: 5 ms/channel, 8 channels resolution: max. 16 bits, accuracy: ±0.1 % F.S. or less (at 25 °C 77 °F), insulation between channels Resistance temperature detector (Pt100, JPt100 and Pt1000), conversion rate: 25 ms/channel, 8 channels accuracy: ±0.1 % F.S. or less (at 25 °C 77 °F), insulation between channels Part No. AFP7TC8 AFP7RTD8 Add-on cassettes Product name FP7 function cassettes Specifications Analog input, 2 channels, voltage / current Analog input and output, input: 2 channels, output: 1 channel Thermocouple input, 2 channels, K / J Part No. AFP7FCAD2 AFP7FCA21 AFP7FCTC2 Expansion unit lineup Expansion units Product name FP7 expansion master unit FP7 expansion slave unit Expansion cables Specifications Expansion of up to 3 slave units possible Up to 16 units can be connected to 1 slave unit. Length: 0.5 m 1.640 ft Length: 1 m 3.281 ft Length: 3 m 9.843 ft Length: 10 m 32.808 ft Part No. AFP7EXPM AFP7EXPS AFP7EXPCR5 AFP7EXPC01 AFP7EXPC03 AFP7EXPC10 New functions Supports the following functions from Ver. 2.4 of Control FPWIN GR7. • Mnemonic ladder 2014.10 • Simulation • Data editor panasonic.net/id/pidsx/global Panasonic Industrial Devices SUNX Co., Ltd. Global Sales Department No. LCE-FP7V2ANALOG-7 October, 2014 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan ■Telephone: +81-568-33-7861 ■Facsimile: +81-568-33-8591 All Rights Reserved ©Panasonic Industrial Devices SUNX Co., Ltd. 2014
AFP7EXPC01 价格&库存

很抱歉,暂时无法提供与“AFP7EXPC01”相匹配的价格&库存,您可以联系我们找货

免费人工找货
AFP7EXPC01
  •  国内价格 香港价格
  • 1+1038.485771+128.82368
  • 10+944.0851410+117.11333

库存:1